Toro 212 User Manual

ON
GreenKeeper 212 Features:
• Easily Expandable Up To 12 Stations With 2-Station Plug-In Modules
• 3 Watering Programs With:
- Calendar, Interval and Odd/ Even Days
- 1 Min. to 4 Hrs. Zone Run Time
- 4 Start Times Per Program
• Battery Back-Up
• Automatic Pump Start
• Seasonal Run Time Adjust
• Rain Delay
• Rain Sensor Ready
• Remote Control Ready
• Snap-In Wire Connectors
Automatic Sprinkler System Controller
User’s Guide
MANUAL
PROGRAMS
B
R
START
NEXT
OFF
Introduction and Set Up
GreenKeeper 212 Components......................2-5
Sprinkler System Basics....................................6
Watering Program Basics..................................7
Watering Program Details ..............................8-9
Planning Your Watering Schedule...................10
Filling Out The Watering Schedule Form ...10-11
Watering Schedule Form..............................12
Programming Before Installation .....................13
Installing The Battery.......................................13
Selecting Optional Features ............................14
24-Hour Clock Mode.....................................14
15-Second Run Delay ..................................14
Odd/Even Watering Days..............................14
About The Controller Memory..........................14
Resetting The Controller Memory....................15
To Reset The Permanent Memory................15
To Clear The Memory ..................................15
Programming The Controller
Setting The Current Time And Day or Date.....16
Setting The Watering Day Schedule ..........17-19
Setting A Calendar Schedule........................17
Setting An Interval Schedule.........................18
Setting An Odd or Even Schedule................19
Turning Off A Program .................................19
Setting Program Start Times ...........................20
Setting Station Run Times...............................21
Installation
Mounting The Controller..................................22
Connecting The Valves....................................23
Connecting A Pump Start Relay......................24
Connecting The Transformer...........................24
Connecting A Toro Rain Switch.......................25
Controller Operation
Automatic Operation.....................................26
Manual Operations ........................................27
Starting Programs Or Stations Manually.......27
Watering Control Features............................28
To Pause Watering.....................................28
To Resume Watering..................................28
To Cancel Watering....................................28
To Skip Zones.............................................28
To Adjust The Station Run TIme ................29
Turning Off The GreenKeeper 212..................29
Using The Rain Delay Feature ........................29
Using The Season Adjust Feature...................30
Service and Specifications
Replacing The Fuse.........................................31
Adding A Station Module.................................32
Troubleshooting...............................................32
Specifications...................................................33
Warranty Information.......................................33
Electromagnetic Compatibility .........................34
Table of Contents
1
Controller Components
GreenKeeper 212 Introduction and Set Up
2
1
2
3
BATTERY
GreenKeeper 212 Components
The following are brief descriptions of the controller com­ponents and display elements. Each of these items will be explained in further detail within the appropriate pro­gramming, operating and installation sections of this guide.
1 - LCD Display
A - “Start Time” symbol – Alarm clock is displayed
when setting the program start times.
B - Program start time identification numbers 1–4. C - Main display of various time values and prompts. D - Program A, B and C identifiers. E - “Watering On” symbol – Water droplet indicates a
watering station is running. Droplet flashes if water­ing is paused.
F - “Watering Off” symbol – Water droplet with slash
indicates all watering activity is Off.
G -“Power Off” symbol – Displayed when 24 V a.c. is
disconnected and controller is on battery power only.
H - “Low Battery Voltage” symbol – Indicates low bat-
tery voltage (when transformer is disconnected).
I - Watering Station identification numbers. J - “Percent” symbol – Indicates the Season Adjust
feature is in use.
K - Day of the week identifiers. L - “Run Time” symbol – Hourglass is displayed when
setting the watering station run times.
2 - Control Buttons
+/
ON button – Increases the time display, scrolls for-
ward through the program information and selects watering days.
–/
OFF button – Decreases the time display, scrolls
backward through the program information and removes watering days.
NEXT button – Advances to the next portion of pro-
gram information. Resumes watering if paused. Advances through stations manually when watering.
MANUAL START button – Selects and starts manual
watering operations.
3 - Control Dial – Selects all controller programming
and operation controls (except Manual Start).
Control Dial Positions
RUN – The normal dial position for all automatic
and manual operations.
CURRENT TIME/DAY – Enables the clock time
and day to be set.
WATERING DAYS – Enables the watering day
schedules to be set and reviewed.
PROGRAM START TIME – Enables the program
start times to be set and reviewed.
STATION TIMES – Enables the station run time to
be set and reviewed. (continued)
3
Controller Components
3 - Control Dial Positions (continued)
SEASON ADJUST – Enables the run time of all
zones in a program to be simultaneously increased or decreased in 10% increments.
OFF – Shuts off and prevents all automatic and
manual watering activity.
RAIN DELAY – Enables all watering operations to
be delayed from 1 to 7 days.
4 - Program Select Switch – Three-position slide
switch used to select watering program A, B or C during the programming procedures and manual operation.
5 - 12 or 24-Hour Clock Selector Jumper – Removing
this jumper selects 24-hour (military time) clock mode. Jumper installed selects 12-hour clock mode.
6 - Run Delay Selector Jumper– Removing this
jumper selects a 15-second delay period before a station begins watering. Jumper installed provides a 2-second delay.
7 - Odd/Even Day Schedule Selector Jumper
Removing this jumper enables an Odd/Even water­ing day schedule to be selected.
8 - Fuse – 0.75 Amp, 250V Fast Blow fuse. 9 - Battery Charger Switch – Controls the battery
charging circuit. Switch positions provided for Alkaline and rechargeable batteries.
10 - Rain Sensor Control Switch – Controls the sensor
input circuit. Switch positions provided for sensor circuit On and Off.
11 - Sensor Connection Terminals – Snap-in connec-
tors for connection of an (optional) Toro Rain Switch.
12 - Common Connection Terminal – Snap-in wire
connector for the valve common wire.
13 - Pump/Master Valve Connection Terminal
Snap-in wire connector for a pump start relay or master valve.
14 - Transformer Connection Terminals – Snap-in
connectors for the plug-in transformer wires.
15 - Plug-In Station Control Module – Each control
module provides snap-in connectors for two station control valve power wires. Up to six modules can be installed.
16 - 9-Volt Battery – The battery maintains the con-
troller memory if the transformer power is discon­nected. Either Alkaline or rechargeable battery types can be installed.
17 Power Supply – A Plug-in transformer supplies
24 V a.c. power to the controller. (Domestic transformer version shown.)
18 - Remote Control Receiver Jack – Modular jack
provided for connection of the optional Toro Remote Control receiver cable. (Refer to the instructions provided with the remote control device for installation and operation details.)
4
5
3
Controller Components
4 5 6
7
18
8
BATTERY
9
10
11 12 13
14
15
16
17
The three main components of every automatic sprinkler system are the controller, station control valves and sprinklers.
The controller is the brain of the system, telling the control valves when and how long to supply water to the sprin­klers. The sprinklers direct and control the water applied to the lawn and plants.
Each valve controls a specific group of sprinklers called a watering station. The stations are generally laid out and installed according to the type of plant material to be watered, the location of the plant within the landscape and the maximum amount of water which can be sup­plied. Each valve is connected to a numbered terminal within the controller, identifying it as Station 1, Station 2, etc.
The controller operates the valves in order, one at a time. In other words, one station would water completely before another station would turn on. This is called a watering cycle. The information stored in the controller memory which determines when and how long the sta­tions will water is called a program.
The next section of this guide is very important. It explains what a program is and how the GreenKeeper 212 controls the operation of the sprinkler system.
Sprinkler System Basics
6
Valve 1 - Station 1 - Parkway Lawn - Fixed Spray Valve 2 - Station 2 - Front Lawn - Fixed Spray Valve 3 - Station 3 - Front Shrubs - Flood Bubbler Valve 4 - Station 4 - Back Lawn - Geared Rotor Valve 5 - Station 5 - Garden - Drip
Valve 1
Controller
Valve 2
House
Valve 3
Valve 4
Valve 5
ON
MANUAL
NEXT
START
PROGRAMS
B
CA
OFF
R
A watering program requires three basic instructions to operate automatically:
• What days to water –called watering days
• When to water – called a program start time
• How long to water – called station run time The following example illustrates how a typical watering
program could be set for the sprinkler system shown on the previous page.
Example: The program start time is set for 5:00
AM. Lawn
stations 1 and 2 each have a run time of 10 minutes and lawn station 4 is set to run for 20 minutes. Note that sta­tions 3 and 5 water shrubs and flowers and have been excluded from this program. (These stations will be set to operate on separate programs).
As shown in the watering program diagram, at 5:00
AM
the controller starts the program watering cycle. Station 1 sprinklers run for 10 minutes and shut off. Station 2 sprinklers turn on, run for 10 minutes and shut off. The controller skips station 3 and turns on station 4, which runs for 20 minutes and shuts off. Station 5 is skipped and the watering cycle ends at 5:40
AM.
As you can see from this example, only one program start time was needed to operate three different stations.
Because of variations in plant watering needs, the GreenKeeper 212 provides three separate programs. The programs, called A, B and C, are completely inde­pendent of one another – like having three timers in one housing.
Using more than one program for example, would enable lawn zones to be watered every day on program A, shrub zones to run on on Monday, Wednesday and Fri­day on program B and drip irrigation to soak the flower beds every three days on program C.
Although the GreenKeeper 212 offers the multiple pro­gram feature, you may want to have all zones on one program if it meets your needs. The other programs can remain turned off until you need to use them.
Watering Program Basics
7
12
Station 1
Program Starts - 5:00
AM
Program Ends- 5:40
AM
Station 2
Station 4
Watering Program Diagram
3
9
6
12
3
9
6
12
3
9
6
This section covers in detail each of the three parts of a watering program – watering days, program start times and station run times.
Selecting Watering Days
The GreenKeeper 212 provides four options for schedul­ing watering days: Calendar, Interval, Odd or Even and Off.
Calendar Schedule
A Calendar schedule enables you to select specific days of the week to water, for example, Monday, Wednesday and Friday. This is a seven-day schedule which starts on Sunday and ends on Saturday.
This illustration shows how a Calendar schedule would be displayed when the control dial is in the
WATERING DAYS position.
In this example, program A has watering days set for
MO
(Monday), WE (Wednesday) and
FR (Friday).
Interval Schedule
An Interval schedule enables you to set watering days without regard to the actual days of the week. For exam­ple, if you want to water every third day, you would select a 3-day Interval. Interval schedules range from 1-day (watering every day) to 7-day (watering every sev­enth day). Once you have selected an Interval schedule,
you can choose which day of the week will be the first day of the Interval. The number of days in the Interval deter­mines the available start days. For example, if you have selected a 3-day Interval and today is Sunday, you may choose to start the Interval today, Monday or Tuesday.
This illustration shows how an Interval schedule would be displayed. In this exam­ple, program B has a 3-day Interval schedule which will start on Monday.
Odd/Even Schedule
The Odd/Even schedule enables you to select odd even numbered days of the month as watering days.
This illustration shows how an Odd day schedule would be displayed.
Program Off
Selecting OFF suspends the operation of the program when it is not needed. Turning the program off does not alter or erase the watering day schedule of the program, it simply places the program on hold until it is needed.
This illustration shows how a program would be displayed if its watering day schedule is turned off. In this exam­ple, program C is off.
Watering Program Details
8
PGM A
SU MO TU WE TH FR SA
PGM A B C
1 2 3 4 5 6 7 8
SU MO TU WE TH FR SA
PGM A
Selecting Program Start Times
A program start time is the time of day you select to begin an automatic program watering cycle.
It is important to remember that a program only requires one start time to operate automatically.
When a program starts, each station assigned to a pro­gram will water in numerical order, one at a time for its set run time.
Sometimes it is necessary to run a watering program more than one time per day. For example, when growing a new lawn. The GreenKeeper 212 enables each pro­gram to have up to four separate start times per day.
Program start times are numbered 1 through 4. These numbers are shown at the top left of the display next to the start time symbol when the control dial is in the
PROGRAM START TIME position and indicate how
many start times are currently set for the program. This illustration shows how
a program start time is displayed. In this example, program A has one start time (start time number 1) set for 5:00
AM.
Setting The Station Run Time
A station run time is the length of time the station (con­trolled by the valve) will water during the program water­ing cycle. The run time for each station can be set from Off (no run time) to 4 hours, in one-minute increments.
A station is assigned to a program when it is given a run time. If the run time for a station is turned Off in a pro­gram, it will not operate during the program watering cycle. This is how the GreenKeeper 212 enables you to assign stations to different programs.
All stations assigned to the program are shown on the lower portion of the display when the control dial is in the
STATION TIMES position.
This illustration shows how a station run time is dis­played for a program. In this example, zones 1–6 are assigned to program A. Station 1 has a 10-minute run time and station 2 is set to run for 25 minutes.
The station run time being displayed is identified by the flashing station number.
9
Flashing