Toro 2010, 2011, 2020, 2021 User Manual

Introduction
The Field Interface Unit (FIU) provides the communications hardware link between the SiteProTMcentral computer, the SitePro compatible field satellite controllers and the SitePro Central Decoder System components. The FIU is available in four configu­rations to provide various combinations of wireline and radio communication paths. An auxiliary port is provided on all FIU models for switch-type sensor input.
The FIU enclosure is designed for installation in a climate-controlled environment, next to or near the central computer, with a maximum separation distance of 50' (15.2 m). Power for the FIU is provided by a 100–240 V a.c./12 V d.c. 50/60 Hz power supply adaptable to both domestic and international plug receptacles. A lighted On/Off rocker switch located on the front of the FIU controls power to the unit and is circuit-protected with a 1.5 amp fast-blow fuse. An array of indicator lights on the front panel is provided for visual confirmation of system communication activity.
The following instructions cover installation of the Field Interface Unit (FIU), Surge Protection Unit (SPU), Duplex Modular Wall Plate, optional Radio-Link components and optional SitePro Central Decoder System (CDS) components. For Network CDS system installation, additional detailed installation information is provided with the Network CDS Decoder Interface Unit (DIU).
IMPORTANT: For your safety and equipment protection, please comply with all Caution and Warning statements within this document. It is the responsibility of the installer to comply with all NEC and/or local electrical codes that apply to the installation of this equipment. Please refer to page 16 for FCC and CISPR 22 information.
Note:
Some cabling and hardware components are provided for installation of the FIU, Surge Protection Unit (SPU) and duplex modular wall plate. All other materials; i.e., wire, conduit, grounding conductors, communication cable, radio(s) and related radio hardware must be purchased separately.
The diagrams on pages 1–5 depict the various FIU model system configurations. See
Figures 1 and 5 for model 2010
(Figure 1 - Satellite, Figure 5 - CDS), FIgure 2 for model 2020, Figure 3 for model 2011 and Figure 4 for model 2021.
SiteProTMField Interface Unit, Models 2010, 2020, 2011 and 2021 Installation Instructions
Figure 1 - Model 2010 (one wireline port)
1 - Field Interface Unit 2 - 12 V d.c. Power Jack 3 - Power Adapter 4 - Central Computer 5 - COM Port 1 6 - DB-9/DB-9 Serial Cable 7 - Channel 1 (in) 8 - COM Line 1 (out) 9 - RJ11 Modular Cable
10 - Duplex Modular Wall Plate
11 - Shielded Interface Cable 12 - Surge Protection Unit 13 - Communication Cable 14 - Satellite Controller 15 - Communication Cable - COM Path 1
(out to satellites) 16 - Auxiliary Port (optional for sensors) 17 - 1.5A Fuse
50' (15.2 m) max.
14
131612
15
13
10
9
11
7 8
1
+12V DC
4
17
2
5
6
CH 1
CH 2
CH 3
16
AUX
3
Figure 2 - Model 2020 (two wireline ports)
1 - Central Computer 2 - Field Interface Unit 3 - COM Port 1 4 - COM Port 2 5 - DB-9/DB-9 Serial Cable 6 - Power Adapter 7 - Auxiliary Port (optional for sensors) 8 - Channel 2 (in)
9 - Channel 1 (in) 10 - 12 V d.c. Power Jack 11 - 1.5A Fuse 12 - COM Line 1 (out) 13 - COM Line 2 (out)
14 - RJ11 Modular Cable - COM Path 2 15 - RJ11 Modular Cable - COM Path 1 16 - Duplex Modular Wall Plate 17 - Shielded Interface Cable 18 - Surge Protection Unit 19 - Communication Cable - COM Path 1 20 - Satellite Controller - COM Path 1 21 - Communication Cable - COM Path 1 (out to satellites) 22 - Communication Cable - COM Path 2 23 - Satellite Controller - COM Path 2 24 - Communication Cable - COM Path 2 (out to satellites)
2
50' (15.2 m) max.
24
22
23
21
20
19
18
17
14
16
15
12
13
11
5
10
9
5
8
7
6
12
3
4
3
1 - Central Computer 2 - Field Interface Unit 3 - COM Port 1 4 - COM Port 2 5 - DB-9/DB-9 Serial Cable 6 - Power Adapter 7 - Auxiliary Port (optional for sensors) 8 - Channel 3 (in)
9 - Channel 1 (in) 10 - 12 V d.c. Power Jack 11 - 1.5A Fuse 12 - COM Line 1 13 - RJ11 Modular Cable
14 - Duplex Modular Wall Plate 15 - Shielded Interface Cable - COM Path 1 16 - Surge Protection Unit 17 - Communication Cable - COM Path 1 18 - Satellite Controller - COM Path 1 19 - Communication Cable - COM Path 1 (out to satellites) 20 - COM Line 3 (out) 21 - Radio Adapter Cable Assembly 22 - Radio Power Supply Cable 23 - Motorola 2-Way Communication Radio 24 - External Radio Antennas 25 - Radio-Link Equipped Satellite Controller - COM Path 3 26 - Communication Cable - COM Path 3 (out to satellites)
Figure 3 - Model 2011 (one wireline port and one radio port) Note: See page 9 for Radio-Link installation procedures.
50' (15.2 m) max.
18
16
19
25
26
17
24
23
22
15
14
13
12
20
11
10
5
9
5
12
3
4
8
21
7
6
1 - Central Computer 2 - Field Interface Unit 3 - COM Port 1 4 - COM Port 2 5 - COM Port 3 6 - DB-9/DB-9 Serial Cable 7 - Power Adapter 8 - Auxiliary Port (optional for sensors)
9 - Channel 3 (in) 10 - Channel 2 (in) 11 - Channel 1 (in) 12 - 12 V d.c. 13 - 1.5A Fuse 14 - COM Line 3 (out) 15 - Radio Adapter Cable Assembly 16 - COM Line 2 (out) 17 - RJ11 Modular Cable - COM Path 2
18 - COM Line 1 (out) 19 - RJ11 Modular Cable - COM Path 1 20 - Duplex Modular Wall Plate 21 - Shielded Interface Cable 22 - Surge Protection Unit (SPU) 23 - Communication Cable - COM Path 1 24 - Satellite Controller - COM Path 1 25 - Communication Cable - COM Path 1 (out to satellites) 26 - Communication Cable - COM Path 2 27 - Satellite Controller - COM Path 2 28 - Communication Cable - COM Path 2 (out to satellites) 29 - Radio Power Supply Cable 30 - Motorola 2-Way Communication Radio 31 - External Radio Antenna 32 - Radio-Link Equipped Satellite Controller - COM Path 3 33 - Communication Cable - COM Path 3 (out to satellites)
4
Figure 4 - Model 2021 (two wireline ports and one radio port) Note: See page 9 for Radio-Link installation procedures.
50' (15.2 m) max.
28
26
27
25
32
24
23
31
30
22
21
17
20
16
15
14
19
18
13
12
6
11
10
9
6
8
7
12
3
6
4
5
33
29
Installing the Field Interface Unit,Wall Plate Assembly and Surge Protection Unit
1. Position the Field Interface Unit within 6' (1.8 m) of the PC.
Note: Maximum distance is 50' (15.2 m).
2. Using the serial cable(s) supplied, connect the PC to the FIU as illustrated in the appropriate configuration diagram
Figure 1–5.
3.
Note: The methods of cable connection will vary depending on the avail­ability of computer COM ports. DO NOT USE P0 FOR CONNECTION. P0 is recommended for an external modem.
4. With the power switch in the Off position, plug the power adapter into the FIU 12 V d.c. receptacle and the wall socket outlet using the appropriate AC power cord supplied. Leave the FIU power switch in the Off position until the installation has been completed.
5. To prevent the power wire from being accidentally pulled out, install the power wire through the strain relief and tighten securely as shown in
Figure 6. Note: Regulatory agencies specify that when connecting plug-in equip-
ment, the socket-outlet shall be located near the equipment and shall be easily accessible.
6. To facilitate installation of the modular wall plate, install a standard duplex junction box to the wall within 5' (1.5 m) of the FIU. The RJ11 modular cable(s) provided are 6' (1.8 m) in length.
(continued)
5
1 - Central Computer 2 - Field Interface Unit 3 - COM Port 1 4 - DB-9/DB-9 Serial Cable 5 - Power Adapter 6 - Auxiliary Port (optional for sensors) 7 - Channel 1 (in) 8 - 12 V d.c. Power Jack 9 - 1.5A Fuse
10 - COM Line 1 (out) 11 - RJ11 Modular Cable - COM Path 1 12 - Duplex Modular Wall Plate 13 - Shielded Interface Cable 14 - Surge Protection Unit (SPU) 15 - Decoder Interface Unit 16 - Communication Cable 17 - RJ45 Modular Wall Plate Assembly 18 - RJ45 Modular Cable Assembly
L1
Figure 6
Figure 5
- Model 2010 (one wireline port)
Note:
See page 12 for Network CDS installation procedures.
50' (15.2 m) max.
15
18
17
15
18
16
17
16
14
12
11
13
10
9
4
8
7
6
5
12
3
+12V DC
L1
+12V DC
Loading...