Topcon WT100 User Manual

0 (0)
INSTRUCTION MANUAL WIRELESS TERMINAL
WT-100
• Thank you for purchasing the TOPCON WT-100 Wireless terminal.
• Please read this operator's manual carefully before using this product.
• The specifications and general appearance of the instrument, and the content of this manual are subject to change without notice.
• Some of the diagrams shown in this manual may be simplified for easier understanding.
PRECAUTIONS FOR SAFE OPERATION
For the safe use of the product and prevention of injury to operators and other persons as well as prevention of property damage, items which should be observed are indicated by an exclamation point within a triangle used with WARNING and CAUTION statements in this instruction manual.
The definitions of the indications are listed below. Be sure you understand them before reading the manual's main text.
Definition of Indication
C WARNING
C CAUTION
Definition of Indication
This symbol indicates items for which caution (hazard warnings inclusive) is
J
urged. Specific details are printed in or near the symbol.
This symbol indicates items which are prohibited. Specific details are printed in
D
or near the symbol.
This symbol indicates items which must always be performed. Specific details
I
are printed in or near the symbol.
PRECAUTIONS
General
C WARNING
Do not use the unit in areas exposed to high amounts of dust or ash, in areas where there is inadequate ventilation, or near combustible materials. An explo-
D
sion could occur.
Do not perform disassembly or rebuilding. Fire, electric shock, or burns could
G
result.
Power Supply
C WARNING
Do not short circuit. Heat or ignition could result.
D
Do not place articles such as clothing on the battery charger while charging bat-
D
teries. Sparks could be induced, leading to fire.
Do not use voltage other than the specified power supply voltage. Fire or electri-
D
cal shock could result.
Do not use batteries other than those designated. An explosion could occur, or
D
abnormal heat generated, leading to fire.
Do not use damaged power cords, plugs or loose outlets. Fire or electric shock
D
could result.
Use only the specified battery charger to recharge batteries. Other chargers may be of different voltage rating or polarity, causing sparking which could lead to fire
E
or burns.
Do not use the battery or charger for any other equipment or purpose. Fire or
D
burns caused by ignition could result.
Do not heat or throw batteries into fire. An explosion could occur, resulting in
H
injury.
Ignoring this indication and making an operation error could possibly result in death or serious injury to the operator.
Ignoring this indication and making an operation error could possibly result in minor injury or property damage.
To prevent shorting of the battery in storage, apply insulating tape or equivalent to
E
the terminals. Otherwise shorting could occur, resulting in fire or burns.
Do not use batteries or the battery charger if wet. Resultant shorting could lead to
D
fire or burns.
Do not connect or disconnect power supply plugs with wet hands. Electric shock
D
could result.
C CAUTION
Do not touch liquid leaking from batteries. Harmful chemicals could cause burns
F
or blisters.
Wireless technology
C WARNING
Do not use within the vicinity of hospitals. Malfunction of medical equipment could
D
result.
Use the instrument at a distance of at least 22 cm from anyone with a cardiac pacemaker. Otherwise, the pacemaker may be adversely affected by the electro-
E
magnetic waves produced and cease to operate as normal.
Do not use onboard aircraft. The aircraft instrumentation may malfunction as a
D
result.
Do not use within the vicinity of automatic doors, fire alarms and other devices with automatic controls as the electromagnetic waves produced may adversely
D
affect operation resulting in an accident.
Precautions
• Confirm battery remaining level before operating.
• Do not leave the instrument under strong sunlight for a long time. It may cause the instrument to malfunction.
• When transporting the instrument, provide some protection to minimize the risk of shocks. Heavy shocks may cause the measurement to be faulty.
• The instrument can not be submerged underwater. WT-100 is designed based on the International Standard IP54, therefore it is protected from the normal rainfall.
• Remove the battery from the instrument when you would not use it for long period. If this instrument with the battery set in it is stored, the electrolyte may leak to cause a trouble.
• Always clean the instrument after use. If the instrument becomes wet from rain, dry moisture. To clean the instrument, dust off well and then wipe clean with a soft cloth.
• To remove the dust on the surface of the parts made by plastic, never use thinner or benzine. Use a clean cloth moistened with neutral detergent.
• This product is for professional use only! The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to understand the user and safety instructions, before operating, inspecting or adjusting.
• Wear the required protectors (safety shoes, helmet, etc.) when operating.
EXCEPTIONS FROM RESPONSIBILITY
• The user of this product is expected to follow all operating instructions and make periodic checks (hardware only) of the product's performance.
• The manufacturer, or its representatives, assumes no responsibility for results of faulty or intentional usage or misuse including any direct, indirect, consequential damage, or loss of profits.
• The manufacturer, or its representatives, assumes no responsibility for consequential damage, or loss of profits due to any natural disaster, (earthquake, storms, floods etc.), fire, accident, or an act of a third party and/ or usage under unusual conditions.
• The manufacturer, or its representatives, assumes no responsibility for any damage (change of data, loss of data, loss of profits, an interruption of business etc.) caused by use of the product or an unusable product.
• The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage different to that explained in the operator's manual.
• The manufacturer, or its representatives, assumes no responsibility for damage caused by incorrect operation, or action resulting from connecting to other products.
STANDARD PACKAGE COMPONENTS
• Wireless terminal WT-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 unit
• Battery BT-66Q. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 pc.
• Instruction manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 sheet
OPTIONAL ACCESSORIES
• Battery Charger BC-30D, AC/DC Converter AD-14, AC cable
• Tilt holder model-4
• Cable for connection to an external battery
NOMENCLATURE AND FUNCTIONS
Antenna for wireless LAN
Operation panel
Display
Product label: Serial number
Battery cover lug
Battery cover
Battery LOW LED
Name LED Function or status
Power switch Turns ON/OFF the power.
Battery Low LED ON
Wireless LED ON
System LED ON
Power LED ON
Power switch
The battery power is low. Replace it with
solid
the full-charged battery.
The wireless LAN function is valid.
solid
Flash Data are being sent/received.
OFF The wireless LAN is not valid.
This instrument (WT-100) is operating
solid
normally.
Flash Flashes when the system executes any
processing.
OFF This instrument does not operate
normally.
The power is ON.
solid
OFF The power is OFF.
Connector for external battery
(car battery etc.) (DC12 V)
Mounting hole (Small)
Mounting hole
INSTALLING AND REPLACING THE BATTERY
1. Push down the battery cover lug to remove the battery cover.
2. As illustrated, load the battery BT-66Q along the contact's direction.
3. Fit the lugs of the battery cover to the holes first. Then, push the battery cover lug until the cover is locked.
Battery cover lug
Lug
Contact
BT-66Q
$:
• Attach a ferrite clamp filter (ZCAT2035-0930 or equivalent) to the power cable when using an external battery. Always wind the cable through the clamp filter in a single loop.
Do not remove the ferrite clamp filter from the cable. Removal of the ferrite clamp filter may cause harmful interference and will void the user’s authority to operate this equipment.
BASIC OPERATION
1. Turn on the power. Press the power switch. Power LED lights. Make sure Wireless LED, System LED and Power LED light up on the front surface.
$:
• When the LED does not light or flash, check if the battery is securely inserted.
2. Wireless LAN connection
Connecting to Imaging Station IS series
CRefer to the description about setup of wireless LAN in the IS series
instruction manual.
Connecting to Data Collector FC-250
CRefer to the description about use of wireless LAN in the FC-250
instruction manual.
$:
The factory default setting of WT-100 is shown below.
• SSID1: WT-100-W6zzzz
• Encryption key: Not used.
• Encryption scheme: Not used.
• Wireless channel: Auto *"W6 zzzz" is the same as the serial number on the bottom of the instru-
ment.
Sometimes an error message indicating the communication error with DHCP server is displayed on the product connected to WT-100. In this case, net­work connection with WT-100 is normal.
INITIALIZATION
In the following cases, it is necessary to initialize WT-100.
• Can't connect even after checking how to connect or the setting of the product (IS series, FC-250, etc.) that should be connected to WT-100.
• When you change IP address of this instrument and forget the IP address.
• When you want to change the setting back.
G:
• All setting contents will be deleted upon initialization. So please write down any necessary information beforehand.
z When you want to carry out initialization, contact the Topcon head office or
your local Topcon dealer.
SPECIFICATIONS
Wireless function Communication range:
Approx. 300m (This is applied when IS2 is used. This can be changed depending on any obstacle between the communicating instruments or ambi­ent conditions.)
Support format:
IEEE802.11g, IEEE802.11b
Channel:
11 (1 - 11ch)
Band:
2.4GHz (2412 - 2462MHz)
Network speed:
IEEE802.11g: 54Mbps (Max.) IEEE802.11b: 11Mbps (Max.)
Transfer mode:
IEEE802.11g: Orthogonal Frequency Division Multiplexing (OFDM) IEEE802.11b: Direct sequence spread spectrum (DSSS)
Access mode:
Infrastructure mode
Security:
WEP (64/128bit) WPA-PSK (TKIP/AES) WPA2-PSK (TKIP/AES) Hidden SSID (Enable/Disable)
Software function LAN setup mode:
Fixed IP address (Manual setting) DHCP server (Enable/Disable)
Routing function:
Dynamic routing, Static routing