Toner Cable LaserPlus User Manual

LaserPlus
1 GHz High Density Compact CATV Optical Transmission System
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
The three (3) rack-unit LaserPlus chassis accepts up to fifteen “mix­and-match” applications modules and single or dual redundant inde­pendent power supplies (AC or DC), minimizing headend space requirements. This fully-integrated, cost effective package utilizes many of the very latest RF and optical design techniques to provide superior system performance to beyond 1,000 MHz, while dramatically reducing component size and minimizing system powering requirements, and the costs normally associated with them.
The LaserPlus transmission platform is the perfect companion to opti­cal receiver/node products in the Olson Technology, Inc. MetroNode Model OTMN-II and PremiseNode Model OTPN-x product families, but is also designed to operate seamlessly with optical transmitters, receivers and nodes from most leading manufacturers.
LaserPlus System
Features
• Compact: Space-Efficient 3RU footprint means that up to 13 chassis can be installed in a standard 70" rack
• High Density: Up to 15 applications modules per 3RU 19" EIA chassis; 195 modules per 70" rack
• Scalable: Full lineup of application modules opti­mizes virtually any CATV system architecture, from traditional 4:1 “blast-and-split” HFC configurations to newer topologies with 1:1 forward path segmentation
• High Performance Fwd 1310nm Transmitters: 3dBm to 15dBm outputs @ 1310nm; 195 per 70" rack
• Triple Return Receivers: Up to 45 fully independent 1310/1550nm receivers per chassis; 585 per 70" rack
• Other Modules: 1550nm Fwd FTTP Tx; CWDM/DWDM R-Tx; DWDM QAM Tx; Block Down Converter
• Return Path Segmentation: via 2:1 or 4:1 (5-42/65 MHz) block downconverters; Field-proven since 1999
• Remote Monitoring and Control: Optional network management interface supports SNMP via Ethernet port
• Local Status Monitoring: Rear chassis DB-25 con­nector outputs individual module summary alarms via contact closures, and LEDs on each module indicate general operating status & key operating parameters
• Convenient Test Points: Optical and RF test points are located on the front panel of each module
• Powering Redundancy: Fully independent, universal 90-264VAC and/or ±48VDC power supplies
• Power Efficiency: < 150 Watts per fully-loaded chas­sis; Runs cooler, reduced power costs & longer life
• Thermal Efficiency: Four hot-swappable fans in chas­sis plenum creates more airflow than module-based fans
• Integrated Fiber Management Tray: Inside the chas­sis, above and in front of the application modules
• Plug-in, Modular Front-Access Design & Hot-Swap Module Capability: Easy replacement & configuration
• Very Cost-Effective
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
The Olson LaserPlus LP-OLAT Advanced LBand Transmitter offers a feature-rich, versatile system in a compact rack-mount package. The Advanced L-Band Transmitter has been engineered to meet today's high performance standards for LBand transport with an extreme bandwidth range that will also allow the system to handle the next generation of satellite signals. The Advanced L-Band system is ideal for a wide variety of communications applications, including L-Band satellite antenna remoting, trunking radio, telemetry tracking, and time and frequency reference distribution. The extended frequency range to 4GHz allows this system to accommodate additional transponders coinciding with common European satellite communication applications.
The enhanced bandwidth to 4GHz is also unique in that it facilitates stacked LNB applications to accom­modate additional transponders containing enhanced DBS programming services (e.g., HDTV, local channels, etc.) over single-mode fiber for DBS television distribution in campus, fiber-to-the-pre-mise (FTTx), and multiple dwelling unit (MDU) environments. The transmitter is offered with 75 Ohm imped­ance using “F” RF connectors or 50 Ohms with SMA RF connectors. Optical connector op-tions include SC/APC and FC/APC. Built-in test points, LED indicators and alarms allow the receiver to be easily set up and maintained.
The LP-OLAT Transmitter is housed in a machined Aluminum enclosure that fits the standard LaserPlus chassis allowing up to 14 or 15 modules in a 3RU space. (The exact number is determined by the num­ber of power supplies in the chassis, single or dual).
LaserPlus LP-OLAT Advanced L-Band Transmitter
Min Typ Max Units
Operating Wavelength 1310 nm Operating Wavelength 1550 nm
Operating Wavelength (CWDM) 1290 1610 nm Operating Wavelength (DWDM) 22 46 ITU ch
Tx Output Power (DFB) +5 dBm
3 mW
Tx Output Power
(DFB, CWDM) +4 dBm
2.5 mW
Tx Output Power (DFB, DWDM) +9 dBm
8 mW Tx Return Loss >55 dB Optical Connector SC/APC (Standard) Optical Connector FC/APC (Optional)
Optical Characteristics (with SM 9/125μm Fiber)
Min Typ Max Units
Frequency (non-DWDM Models) 10 4,000 MHz Amplitude Flatness Any 500MHz / ±1.5 dB
Any 40MHz / ±0.35 dB Return Loss 10 dB Output Impedance
(Standard) 75 Ohms
Output Impedance (Optional) 50 Ohms Link Gain -50 +30 dB Noise Figure
(See manual) 10 45 dB
Tx Input IP3 -10 +15 dBm Tx Input P 1dB -12.5 +12.5 dBm Tx Input/Rx Output VSWR 1.9:1 Tx Total RF Input Power -25 0 dBm Hi/Lo Gain Switch 0 +10 dB
Hexadecimal Rotary Gain Switch 0 +15 dB
RF and System Characteristics
Min Typ Max Units
Tx Weight 14.1 oz
0.40 kg
Transmitter Dimensions 4.5H x 1.125W x 8.75D in
114H x 29W x 222D
Physical Characteristics
NOTES:
1) The RFgain will change 2dB for each 1dB of optical loss.
2) The transmitter P
1dB
and also IP3 varies dB per dB as the
gain is changed. See the manual for detailed data.
3) Noise figure is a complex variable that is influenced by the Tx and Rx attenuator settings as well as the optical loss. See the manual for detailed data.
4) The Hi/Lo Gain switch on the front panel changes the gain by +10dB. The hexadecimal rotary switch on the front panel changes the gain in 1dB steps. The “0” setting on the rotary switch is the lowest gain (0dB). The “F” setting on the rotary switch is the highest gain (+15dB).
Specifications
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
The Olson LaserPlus LP-OLAR Advanced LBand Receiver offers a feature-rich, versatile system in a compact rack-mount package. The Advanced L-Band Receiver has been engineered to meet today's high performance standards for L-Band transport with an extreme bandwidth range that will also allow the sys­tem to handle the next generation of satellite signals. The Advanced L-Band system is ideal for a wide variety of communications applications, including L-Band satellite antenna remoting, trunking radio, telemetry tracking, and time and frequency reference distribution. The extended frequency range to 4GHz allows this system to accommodate additional transponders coinciding with common European satellite communication applications.
The enhanced bandwidth to 4GHz is also unique in that it facilitates stacked LNB applications to accom­modate additional transponders containing enhanced DBS programming services (e.g., HDTV, local channels, etc.) over single-mode fiber for DBS television distribution in campus, fiber-to-the-premise (FTTx), and multiple dwelling unit (MDU) environments. The receiver is offered with 75 Ohm impedance using “F” connectors or 50 Ohms with SMA connectors. Optical connector options include SC/APC and FC/APC.
The standard PIN-detector receiver offers high sensitivity for a maximum optical link budget. An optional APD detector increases optical sensitivity by 7dB. Built-in test points, LED indicators and alarms allow the receiver to be easily set up and maintained.
The LP-OLAR Receiver is housed in a machined Aluminum enclosure that fits the standard chassis allow­ing up to 14 or 15 modules in a 3RU space. (The exact number is determined by the number of power supplies in the chassis, single or dual).
LaserPlus LP-OLAR Advanced L-Band Receiver
Min Typ Max Units
Operating Wavelength 1290 1610 nm Optical Input Power
(PIN) -15 +3 dBm
Optical Input Power
(APD) -22 -3 dBm
Optical Return Loss >55 dB Optical Loss Budget (PIN) 7 25 dB Optical Loss Budget (APD) 13 32 dB Optical Connector SC/APC (Standard) Optical Connector FC/APC (Optional)
Optical Characteristics (with SM 9/125μm Fiber)
Min Typ Max Units
Frequency 10 4,000 MHz Amplitude Flatness Any 500MHz / ±1.5 dB
Any 40MHz / ±0.35 dB Return Loss 10 dB Output Impedance
(Standard) 75 Ohms
Output Impedance (Optional) 50 Ohms Link Gain -50 +30 dB Noise Figure
(See manual) 10 45 dB
Rx Input IP3 +12 dBm Tx Input P 1dB -2 dBm Hi/Lo Gain Switch 0 +10 dB
Hexadecimal Rotary Gain Switch 0 +15 dB
RF and System Characteristics
Min Typ Max Units
Rx Weight 14.1 oz
0.40 kg
Receiver Dimensions 4.5H x 1.125W x 8.75D in
114H x 29W x 222D
Physical Characteristics
NOTES:
1) The RF gain changes 2dB for each 1dB of optical loss.
2) The receiver P
1dB
and IP3 is almost constant over the full RF
gain range.
3) Noise figure is a complex variable that is influenced by the Tx and Rx attenuator settings as well as the optical loss. See the manual for detailed data.
4) The Hi/Lo Gain switch on the front panel changes the gain by +10dB. The hexadecimal rotary switch on the front panel changes the gain in 1dB steps. The “0” setting on the rotary switch is the lowest gain (0dB). The “F” setting on the rotary switch is the highest gain (+15dB).
5) Optical Loss Budget based on +10dBm transmitter launch power(DWDMDFBLaser).
Specifications
Specifications Subject To Change Without Notice Rev 06-11 ©Toner Cable Equipment, Inc.
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
LaserPlus
1 GHz High Density Compact CATV Optical Transmission System
The LaserPlus Model LP-CH-16 Chassis fits into a 19­inch EIA rack, and holds up to 15 interchangeable, hot­swappable, plug-in application modules. Each chassis requires one power supply & accepts a 2nd for hot redundant backup, & has provisions for both local monitoring & remote SNMP element management.
The chassis is very compact, occupying only 5.25” (3 RU) of rack space. Universal slots accept almost any “mix-and-match” combination of Olson Technology, Inc.
LaserPlus Model LP-x transmitter, receiver, EDFA, block downconverter, passive optical coupler or WDM application modules, to accommodate a limitless variety of service delivery architectures and provide flexibility and scalability in headend/hub design and zone arrangements.
It also includes an integrated internal fiber management tray. The connecting optical fiber(s) can enter the chassis from the front, or from fiber routing apertures located on either (or both) sides of the chassis. Once the fiber connection is made, the fiber cable can be secured in an integrated fiber management tray, located above the application modules. Drop slots are conveniently placed along the tray to assure minimum fiber clutter in front of the modules. The application modules slide into the chassis from the front of the rack, and all RF coaxial cables are connected at the rear.
A single AC or DC power supply module plugged into the primary power supply slot# 16 is sufficient to power a fully loaded LaserPlus chassis; two power supplies (in slots# 15 & 16) may be used to provide hot-redundant backup. For maximum fail­safe protection, an AC module can be used in combination with a DC module to provide simultaneous AC and DC powering to the LaserPlus chassis.
LaserPlus Chassis
ELECTRICAL, ENVIRONMENTAL & MECHANICAL PARAMETERS:
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .5.25” H x 19” W x 14.5” D (13.3 cm x 48.3 cm x 36.8 cm)
Weight (Empty) . . . . . . . . . . . . . . . . . . . . . . .10 lb (4.54 kg)
Operating Temperature Range . . . . . . . . . . .0°C to +50°C (+32°F to +122°F)
(Air temperature measured at air inlet of Model LP-CH-16 chassis)
Humidity Range . . . . . . . . . . . . . . . . . . . . . . .to 95% non-condensing
[Recommended for use only in non-condensing environments]
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Four fans plenum-mounted; user-replaceable (PN# 037-000405)
Module Slots . . . . . . . . . . . . . . . . . . . . . . . . .1-14=application modules; 15=apps or PS; 16=power supply
Powering . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.25VDC per module; 90-264 VAC or -48VDC; < 150 Watts
[Requires use of 1 or 2 Model LP-PS-x power supply module(s)]
CHASSIS INTERFACES:
Local Status Alarms Connector: . . . . . . . . . .DB-25
Electrical Interface: Relay Contact Closure: 100mA @ 25VDC
[Provides ground closures on alarm: PINS 1-15 = SLOTS 1-15;
PIN 17 = Cooling; PIN 24 = Summary; PIN 25 = GND]
SNMP Agent (Optional) Connector: . . . . . . .RJ-45
Electrical Interface: 10BaseT Ethernet [Requires Model LP-CH-SNMP-1 element managment agent]
Loading...