Toner Cable ISOBAR AC Protection User Manual

ISOBAR
Premium Surge Suppressors
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
ISOBAR®AC Protection
Isolated filter banks (an exclusive feature of the
Isobar) eliminates interference between equip­ment plugged into the Isobar.
• Ultimate Lifetime Insurance®covers the Isobar and connected equipment from surge related damage, including direct lightning strikes!
• “Cascade circuitry” allows you to choose increased noise protections levels for your most sensitive equipment (computers, disk drives, scan­ners, PBX’s and key systems) and less for other devices (monitors, lights, TVs and VCRs)
• Isobar’s multiple component circuitry includes MOVs, VHF disk capacitors, toroidal chokes and high frequency capacitors to provide you with pre­mium surge suppression and RFI/EMI line noise filtering
• Provides surge suppression up to 13,000 amps
• Protection in all 3 AC modes; hot to neutral, hot to ground and neutral to ground
• Rugged all-metal housing provides additional shielding of ambient RFI/EMI interference
• Ideal for protecting sensitive equipment including computers, network nodes, fileservers, phone systems and point-of-sale terminals
AC AND COAX ISOBAR
®
For Tvs, VCRs and Cable Installations
• Premium protection from spikes that travel through AC and coaxi­al lines
• 2 outlet, direct plug-in with coaxial “F” con­nectors
• Provides instantaneous surge suppression up to 13,000 amp spikes
• Sine wave tracking follows the AC wave form, providing increased surge absorption and
DIRECT PLUG-IN ISOBAR
®
For Copiers and Phone Systems
• Suppresses up to 13,000 amp spikes
• 2 outlet, direct plug-in
• Superior RFI/EMI noise filtering
Models Available:
ISOBLOK is our lowest cost direct plug-in model
ULTRABLOK 428 has diagnostic circuitry and sine wave tracking
ULTRACOPY features diagnostic circuitry, 20 amp plug and receptacles
Model: ULTRACOAX Model: ISOBLOK 2-0
Specifications Subject To Change Without Notice Rev 07-12 ©Toner Cable Equipment, Inc.
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
ISOBAR
Premium Surge Suppressors
Original ISOBARS
ISOBAR 2-6 2 1 Yes 280 6' 2 1¼2 x 5 1¼2 x 3 1¼2 2 isolation, cascade circuitry G $10,000 ISOBAR 4 4 2 Yes 420 6' 2 1¼2 x 6 1¼2 x 3 1¼2 2 isolation, cascade circuitry G $10,000 ISOBAR 6 6 3 Yes 490 6' 2 1¼2 x 8 1¼2 x 3 1¼2 2.5 isolation, cascade circuitry G $10,000 ISOBAR 8 8 4 Yes 560 12' 2 1¼2 x 9 1¼2 x 3 1¼2 3 isolation, cascade circuitry G $10,000 ISOBAR 8RM 8 4 Yes 280 12' 2 1¼2 x 9 1¼2 x 3 1¼2 3.5 includes remote control w/ 9' cord G $10,000 ISOTEL 4 4 2 Yes 420 6' 2 1¼2 x 6 1¼2 x 3 1¼2 2 fax/modem protection, RJ11 A,B,E,G $10,000
ISOBARS ULTRAS
ISOBAR 4 ULTRA 4 2 Yes 490 6' 2 1¼2 x 6 x 3 1¼2 2 diagnostics,isolation, cascade circuitry C,G $25,000 ISOBAR 6 ULTRA 6 3 Yes 560 6' 2 1¼2 x 7 1¼4 x 3 1¼2 2.5 diagnostics,isolation, cascade circuitry C,G $25,000 ISOBAR 8 ULTRA 8 4 Yes 630 12' 2 1¼2 x 8
7/
8
x 3 1¼2 3 diagnostics,isolation, cascade circuitry C,G $25,000 ISOTEL 6 ULTRA 6 3 Yes 560 6' 2 1¼2 x 7 1¼4 x 3 1¼2 2.5 diagnostics, fax modem protection, RJ11 A,B,C,E,G $25,000 ISOTEL 8 ULTRA 8 4 Yes 630 12' 2 1¼2 x 8 7¼8 x 3 1¼2 3 diagnostics, fax modem protection, RJ11 A,B,C,E,G $25,000
Under Monitor ISOBARS
CCI6 6 1 Yes 420 9' 2 x 13 1¼2 x 12 1¼2 6 low profile console style G $10,000 CCI6PLUS 6 1 Yes 420 9' 2 x 13 1¼2 x 12 1¼2 6 console style, fax/modem protection, RJ11 A,B,E,G $10,000 CCI/230 5 1 Yes 600 6' 2 x 13 1¼2 x 12 1¼2 6 console style, 220 volt applications F,G $10,000
ISOBARS for Special Applications
ISOMASTER 4 2 Yes 350 6' 2 1¼2 x 8 3¼4 x 3 1¼2 2.5 load sensing (master/slave circuitry) G $10,000 IBR12
(Rack-mount) 12 2 Yes 320 12' 1
3
¼4 x 19 x 4 4.5 rack-mount model (19'' wide) G $10,000
ISOBAR 4/220 4 2 Yes 600 6' 3
1
¼2 x 6 x 2 1¼2 2 220 volt applications G $10,000
EUROBAR (220 volt) 4 2 Yes 600 6' 3
1
¼2 x 7 x 2 1¼2 1.5 IEC-320 receptacles/220 volt applications F,G $10,000
Direct Plug-in ISOBARS
ULTRABLOK 428 2 1 No 280 4 x 2 1¼2 x 2 1¼2 1 diagnostics, sine wave tracking C $10,000 ULTRACOAX 2 1 No 280 4 x 2
1
¼2 x 2 1¼2 1 diagnostics, coax protection C,J $10,000 ULTRAFAX 2 1 No 280 4 x 2 1¼2 x 2 1¼2 1 diagnostics, fax/modem protection A,C,E $10,000 ULTRACOPY 2 1 No 280 4 x 2
1
¼2 x 2 1¼2 1 diagnostics, 20 amp capacity C,D $10,000 ISOFAX 2 1 No 280 5
1
¼4 x 2 1¼2 x 2 1¼4 .5 2 datalines, fax/modem protection, RJ45 A,E,H $10,000
ISOBLOK 2-0 2 1 No 280 4 x 2 1¼2 x 2 1¼2 .5 mounting tab for secure connection $10,000
Model
No. of
Receptacles
No. of
Isolated
Filter
Banks
Resettable
Circuit
Breaker
AC
Energy
Absorption
(Joules)
AC
Cord
Length
Dimensions
H x W x D
(inches)
Weight
(lbs.)
Special Features Additional
Specifications*
ULTIMATE Insurance
Limit
*Additional Specifications (A) Dataline specs: Clamping Voltage: 235 V peak ± 10%
Response Time: 5 nanoseconds Peak Transient Input Voltage: 6 Kv, 10
microseconds (B) Input/Output: RJ11 modular jack (protects 1 dataline) (C) Diagnostic indicators show improper outlet wiring,
damage to protection circuitry and loss of AC power (D) NEMA 5-20 plug and receptacle (E) All fax/modem products come with 12' dataline cord (F) IEC-320 receptacles
(G) Includes On/Off switch (H) Input/Output: RJ45 modular jack (protects 2 datalines) (J) Coaxial circuit specifications:
Clamping Level: ±27 volts Rated Energy dissipation: 7 joules Peak Pulse Power Dissipation: 1500 watts Insertion Loss:<3db
1449 Surge suppression (330 volt let-through) 497A Dataline protection 1283 Line noise filtering