Specifications Subject To Change Without Notice Rev 02-12 ©Toner Cable Equipment, Inc.
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
SPECIFICATIONS Forward Path Return Path
Technology Power Doubling, GaAs, Hybrid Push Pull, Si-Bipolar
Frequency Range 54-1000 MHz (85-1000MHz optional) 5-42 MHz
Gain 38 dB (+/-1dB) 24 / -2dB switchable
Input Gain Control Plug-in, fixed value , 0 to 20dB in 2dB steps, 0 to 18dB variable
Second Stage Gain Control 0 to 10dB variable, mid stage Plug-in, fixed value , 0 to 20dB in 2dB steps
Input Slope Control Plug in, fixed value, 0 to 20dB in 2dB steps NA
Second Stage Slope Control 0 to 10dB variable, mid stage NA
Input / Output Return Loss 14 dB 14dB
Noise Figure 5 dB 6 dB
Channel Loading / Output Level NCTA 79ch,Flat Output / 47dBmV 4
Output Level 47dBmV 52 dBmV
Composite Triple Beat (CTB) -67 dBc -60 dBc
Composite Second Order (CSO) -71 dBc -60 dBc
Cross Modulation (XMOD) -63 dBc -58 dBc
Impedance 75 ohm 75 ohm
Hum Modulation -70 dBc -70 dBc
Input / Output Test Port Level -30 +/- 1dB
Operating Temperature Range -10C ……+55 degree C.
Input / Output Connections F type
Surge Withstand (IN/OUT) IEEEC62.41 Cat.A3(6kV,200A)
Power Requirement Wall Power Transformer, Input = 90-240VAC , 50-60Hz, 1A
Output = 24 +/-1VDC, 1.25A
Size (L x W x H) 19’’ x 8.5’’ x 1.75’’
Shipping Weight 6.75 lbs
HEA-37
Headend Amplifier