is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.
1
SAFETY SYMBOLS
These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
CAUTIONWARNING
accompanying the appliance.
Using any part other than genuine Toastmaster factory supplied parts relieves the
manufacturer of all liability.
Toastmaster reserves the right to change specications and product design
without notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change
without notice. While Toastmaster exercises good faith efforts to provide
information that is accurate, we are not responsible for errors or omissions
in information provided or conclusions reached as a result of using the
specications. By using the information provided, the user assumes all risks in
connection with such use.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance.
Please record the model number, serial number, voltage and purchase date in the area below and have it
ready when you call to ensure a faster service.
ModelHeight x Width x DepthGrid AreaControlsNAT / LP
TMLC24
TMLC36
TMLC48
TMRC24
TMRC36
TMRC48
48cm x 61cm x 65.4cm3097 sq. cmLP: 70,000 BTU/HR67.7 kg74.5 kg
48cm x 91.4cm x 65.4cm4645 sq. cmLP: 105,000 BTU/HR107.3 kg116.4 kg
48cm x 122cm x 65.4cm6194 sq. cmLP: 140,000 BTU/HR146.8 kg158.2 kg
48cm x 61cm x 65.4cm3097 sq. cmLP: 70,000 BTU/HR63.5 kg70.3 kg
48cm x 91.4cm x 65.4cm4645 sq. cmLP: 105,000 BTU/HR100 kg109 kg
48cm x 122cm x 65.4cm6194 sq. cmLP: 140,000 BTU/HR136 kg147.7 kg
19” (48.26)
B
15.5” x 24” x 29”480 sq. in
15.5” x 36” x 29”720 sq. in
15.5” x 48” x 29”960 sq. in
15.5” x 24” x 29”480 sq. in
15.5” x 36” x 29”720 sq. in
15.5” x 48” x 29”960 sq. in
1 7/8 (4.66)
2
3
4
2
3
4
NAT: 80,000 BTU/HR149 lbs164 lbs
NAT: 120,000 BTU/HR236 lbs256 lbs
NAT: 160,000 BTU/HR323 lbs348 lbs
NAT: 80,000 BTU/HR140 lbs155 lbs
NAT: 120,000 BTU/HR220 lbs240 lbs
NAT: 160,000 BTU/HR300 lbs325 lbs
3/4 MPT INLET
4 (10.16)
(+1 (2.54))
IL1875
Weight
InstalledShipped
2M-Z12963: Gas Radiant & Lava Rock Charbroilers TMRC & TMLC
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.
3
CAUTION
GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations.
The Toastmaster series gas charbroiler is equipped for the type of gas indicated on the nameplate
mounted on the front panel. All units are shipped from the factory for use with natural gas. The unit
can easily be converted for use with propane gas: see propane gas.
-IMPORTANT-
INSTALL IN NON-COMBUSTIBLE LOCATIONS ONLY! Clearance from non-combustible
construction must be 6" from back and sides.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE
"ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND
REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2
PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, injury or death. Read the installation, operating
and maintenance instructions thoroughly before installing or servicing the
equipment.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance. Keep the appliance area clear and free from combustibles.
For your protection, we recommend a qualied installing agency install this appliance.
They should be familiar with gas installations and your local gas requirements. In any
case, your gas company should be called to approve the nal installation. In addition,
there should be posted, in a prominent location, detailed instructions to be followed in the
event the operator smells gas. Obtain the instructions from the local gas supplier.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2
PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 PSIG.
EXHAUST CANOPY
Open hearth broilers inherently create a good deal of heat and smoke and should be installed under
an efcient exhaust hood with ame proof lters. A vertical distance of not less than 48" shall be
provided between the top of the appliance and lters or any other combustible material. Exhaust
installation must conform to local codes.
AIR SUPPLY
Provisions for adequate air supply must be provided.
LEVELING UNIT
This charbroiler is supplied with 4 feet which must be screwed into the body. Level unit by adjusting
the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other units.
2M-Z12963: Gas Radiant & Lava Rock Charbroilers TMRC & TMLC
CAUTION
DO NOT INSTALL WITHOUT ATTACHING FEET - DO NOT REMOVE FEET.
4
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas sufcient to meet
the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be
checked to determine if it has adequate capacity. Joint compound shall be used sparingly and only on
the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases.
WARNING: Any loose foreign material, debris, or metal particles allowed to enter the gas lines
on this appliance will damage the valve and affect its operation. When installing this appliance,
all pipe and ttings must be free from all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each charbroiler. It should be connected to the
inlet pipe at the rear of the unit. The gas supply is then connected to it. It is shipped set for 6" water
column manifold pressure for use with natural gas. Allow 6" clearance from back of unit to wall for
servicing and installation.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of the
charbroiler.
CONNECTING GAS SUPPLY LINE
The gas inlet of the charbroiler is sealed at the factory to prevent entry of dirt. Do not remove this seal
until the actual connection is made to the gas supply line.
PROPANE GAS
This charbroiler is equipped with xed orice hoods and is shipped from the factory for use with
natural gas. To convert to propane gas, install the burner orice hoods, included with the unit, as
follows:
1. Remove grill, radiants and burners.
2. Remove the burner orice hoods and install the orice hoods supplied.
3. Replace the burners, radiants, and grill.
4. Set manifold pressure to (10) inch water column. A 1/8" pipe plug on the burner manifold can
be removed for attaching a pressure gauge. Remove the slotted, or hex-threaded plug from the
pressure regulator. Invert the plug and re-install. The letters "LP" should now be visible on the
plug. The regulator is now set for 10" (25.4 cm) water column. Attach the conversion label, supplied
with the unit, close to the nameplate.
CAUTION
2M-Z12963: Gas Radiant & Lava Rock Charbroilers TMRC & TMLC
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable for the
purpose shall be used in locating gas leakage.
Matches, candle ame or other sources of ignition shall not be used for this
purpose.
5
PILOT LIGHTING INSTRUCTIONS
The charbroiler is equipped with standing pilots, and should be lit immediately after the gas is turned on.
1. Turn off main valve to unit.
2. Turn off all knobs and pilot valves and wait 5 minutes to clear gas.
3. Turn on main valve and light all pilots. The best access to the pilot is obtained from the bottom
with the grease drawer removed.
4. Adjust pilot light ames as small as possible, but high enough to light burner immediately when
burner valve is turned on high.
5. Turn burner knobs to desired setting.
6. To turn burners off, turn knobs off.
SHUTTING DOWN INSTRUCTIONS
Turn the burner valve knobs to the off position to turn burners off.
BURNER IGNITION AND ADJUSTMENT
1. To ignite burners turn burner valve knob to "HI" position.
2. Slowly decrease openings of air shutters on burners to give a soft blue ame having
luminous tips, then slowly increase openings to a point where the yellow tips disappear
and a hard blue ame is obtained.
PLACING LAVA ROCK ON GRATES
(FOR TMLC SERIES)
Open the lava rock bags and place rock evenly on grates. Do not cover the grates with more than two
layers of lava rock. DO NOT PUT MORE THAN 5 LBS. OF ROCK PER BURNER!
BURNER OPERATION
Each burner is controlled by an individual high-low, on-off valve. An innite number of broiling
temperatures may be obtained by turning the burner valve knob to any position between high and
low. It is possible through this arrangement to have a high heat or searing section, while having a low
heat nishing or holding section. For the searing operation, set the valves for the section at a position
of "HI" or close to it. For holding or nishing, set the valves closer to the "LOW" position on the dial.
You select the heat pattern you like, and set the valves accordingly.