Tmi S-CFD-108-3-2S User Manual

Page 1
A Stainless Steel Air Curtain for Every Budget
A Stainless Steel Air Curtain for Every Budget
Managing Environments™
Revolutionary
Air Curtain with
AERODYNAMIC
Compression
Chamber
Generating
Air Movement
Page 2
Contents
age
P
1 . . . . . . . . . . . . Cover
2 . . . . . . . . . . . . Table of Contents
3 . . . . . . . . . . . . Making a Save-T Air Curtain
3 . . . . . . . . . . . . How a Save-T Air Curtain Works
4 . . . . . . . . . . . . When to Use a Save-T Air Curtain
4 . . . . . . . . . . . . Application Selection Guide
4 . . . . . . . . . . . . Choosing Your Model
5 . . . . . . . . . . . . Matching Your Doorway Opening
Save-T Air Curtain
with a
6 . . . . . . . . . . . . A Guide to Energy Saving –
Return on Investment
6 . . . . . . . . . . . . Activation Devices
7 . . . . . . . . . . . . Mounting Options
8 & 9 . . . . . . . . . S-ICM – In-Ceiling Mount Series
10 & 11 . . . . . . . S-AP – Air-Pro Series
12 & 13 . . . . . . . S-CFD – Commercial Front Door Series
14 & 15 . . . . . . . S-IBD – Insect Back Door Series
16 & 17 . . . . . . . S-LP – Low Profile Series
18 & 19 . . . . . . . S-LI – Light Industrial Series
20 & 21 . . . . . . . S-MI – Medium Industrial Series
22 & 23 . . . . . . . S-HD – Heavy Duty Industrial Series
24 & 25 . . . . . . . S-XHD – Extra Heavy Industrial Series
26 & 27 . . . . . . . Optional Equipment and Accessories
28 . . . . . . . . . . . Other TMI Products
2
Page 3
Making a Save-T Air Curtain
TMI, LLC utilizes the highest quality materials to produce its
Air Curtains. The system is constructed of 100% steel com-
ponents. The intake grill, side panels and top & bottom pan-
ls are produced of stainless steel. The fans and fan bas-
e
kets are SG-grade galvanized steel. The unit is assembled
with stainless steel hex screws so the intake grill can be
easily and quickly removed for fast, easy maintenance and
cleaning.
How a Save-T Air Curtain Works
The Save-T Air Curtain is mounted above a doorway
opening, just above the header. Ambient air is drawn
D
E
C
B
A
through the front intake grill (A) and into the fan baskets
(B). The blower wheel (C), forces the air into an air
chamber (D) and the air is forced downward through the
discharge nozzle (E). An invisible “wall of air” is created
that serves as the barrier preventing conditioned air
from leaving the building and blocking outside air from
entering, even when there is no primary door in place.
Top Plate
Fan Baskets & Motor
on Mounting Plate
Air
Chamber
Side
Panel
Bottom
Panel
Bottom
Rail
Side
Panel
Top Rail
Intake
Grill
Revolutionary
tain with
r
r Cu
i
A
ODYNAMIC
AER
Compression Chamber
Generating
“COANDA EFFECT”
Air Movement
Key features:
• Air Chamber design utilizes the Coanda effect to create
a more uniform air flow to maximize efficiency and reduce noise levels
• Aesthetically pleasing design
Heaters (see Optional Equipment & Accessories,
pgs. 26 & 27) can be added to the units so that a
comfortable environment can be maintained for
customers while creating a better, more productive
work area for personnel during the winter months.
Heated units further increase energy savings by
lowering heating and cooling costs.
3
Page 4
When to use a
COLD & WIND
CONTROL
BUG & DUST
CONTROL
HEAT & HUMIDITY
CONTROL
Save-T Air Curtain
Air Curtains reduce energy costs while increasing employee and customer comfort. The high veloc-
ty air screen created by the Air Curtain stops
i outside wind, while circulating the warm air that naturally rises toward the ceiling. During the win­ter months, Air Curtains stop exterior cold drafts from entering through open doorways and pre­vent heated air from escaping. During the sum­mer months, Air Curtains keep warm, humid air outside and prevent the loss of conditioned air.
During the cold months, the Air Curtains save on energy costs by drawing warm air from the ceiling area.
Air Curtains are capable of stopping flying insects from entering through open doorways. Dust and odors can be blocked as well.
When summer heat and humidity become a problem, Air Curtains create an invisi­ble shield that holds the hot, humid air outside.
Matching Your Application with a Save-T Air Curtain
If your application is . . . . . . . . . . . . . . . . then you should use these Save-T Air Curtain models
Climate and Environment Control
Insect and Wind Control
Drive-Thru Windows and Concession Stands
Office and Employee Entrances
Interoffice and Commercial Separation
Hospital Entrances and Hallways
Retail and Customer Entrances
Restaurant and Food Service Entrances
Restaurant and Food Service Back Doors
Hotel, Resort, and Casino Entrances
Hotel, Resort, and Casino Back Doors
Loading Docks
Internal Warehouse Openings
Shipping and Receiving Doors
Auto Body and Open Bays
Paint Booths
Walk-In Coolers and Freezers
Railcar Openings
Commercial
In-Ceiling
Mount Air-Pro Profile Door Door
Low Front Back Light Duty Duty Heavy
Insect
Medium
Industrial Industrial Industrial Industrial
Heavy Extra
S-ICM S-AP S-LP S-CFD S-IBD S-LI S-MI S-HD S-XHD
XXXX XXXX
X X X X X
X X
XXXX
X XX XXXX XXXX XXXX
X
XXXX
X
X
XX X XXXX X
XX X
XXXXX XXXXXX X
X
XX
If you do not see your application please call 1-800-888-9750
Choosing Your Model
To select the correct
1. Type of application (See above chart) Height and width of door
2. Amount of direct external wind exposure in m.p.h.
3.
The entire width of the door
The height of the opening and wind exposure velocity can be handled by controlling the amount of air flow from the unit. Any deficiencies in pressure balance must be remedied by adjusting the source of the imbalance. Note: Approximately 80% of the air flow stays inside the facility Questions about your application? Call TMI, LLC at 1-800-888-9750.
4
Save-T Air Curtain for your application, the following factors should be determined:
4.Pressure balance inside building
way opening
way must be covered by the Air Curtain.
Heating option requirement
5.
, while 20% flows outside.
External
Wind
M.P.H.
Width
+ or -
Pressure
Balance
Height
Page 5
R
ecommended Maximum Height for Flying Insect Control
R
ecommended Maximum Height for Flying Insect Control
Recommended Maximum Height for Flying Insect Control
Recommended Maximum Height for Flying Insect Control
Recommended Maximum Height for
Flying Insect Control
Recommended Maximum Height for
Flying Insect Control
Recommended for Flying Insect Control
Recommended for Flying Insect Control
Recommended Maximum Height for
Flying Insect Control
Recommended Maximum Height for
Flying Insect Control
Matching Your Doorway Opening with a Save-T Air Curtain
XTRA HEAVY DUTY SERIES
E
evolutionary
R Air Curtain with AERODYNAMIC
Compression Chamber
Generating
“COANDA EFFECT”
Air Movement
S-XHD
See
Pages 24-25
TMI, LLC offers the largest selection of Save-T Air Curtains in the industry. Air Curtains can satisfy nearly every application requirement. The chart below shows
aximum doorway heights and widths
m
or each of our units.
f
HEAVY DUTY SERIES
S-HD
See
Pages 22-23
MEDIUM INDUSTRIAL SERIES
DOOR
CK
A
INSECT
B
S-IBD
See
Pages 14-15
S-MI
See
Pages 20-21
SERIES
COMMERCIAL
ONT DOOR
FR
Pages 12-13
LIGHT INDUSTRIAL SERIES
S-LI
See
Pages 18-19
SERIES
IN-CEILING MOUNT SERIES
S-CFD
See
S-ICM
See
ges 8-9
a
P
LOW PROFILE
COMMERCIAL
S-LP
See
Pages 16-17
AIR-PRO SERIES
SERIES
S-AP
See
Pages
10-11
5
Page 6
Activation DevicesLet Us Do the Math!
AAIIRR CCUURRTTAAIIN
JJUUSSTTIIFFIICCAATTIIOONN AANNAALLYYSSIIS
N
S
Please allow TMI’s engineering department to provide state-of-the-art, computer-generated energy saving calculations. Cost savings will be stated in years of payback and can be calculated for both heated buildings or air conditioned applications. The following information is required:
Heating Example
Door height Feet 10 Door width Feet 10 Avg. outside temp. ˚F 32 Avg. inside temp. ˚F 65 Avg. wind speed @ door MPH 10 Open time/day HRS/Day 5 Days of operation/week Days 5 Length of season Weeks 26 Cost of heat $/MMBTU 4.25 Cost of electricity $/KW HR .07
Air Conditioning
In addition to the above data, the following
factors must also be provided:
1. Outside relative humidity in %
2. Inside relative humidity in %
In order to regulate the operation of the Air Curtain, we offer a number of activation devices. These allow
he unit to be inactive until the door needs to be
t
pened, at which time the unit can be automatically
o turned on. Or, if the curtain has a heating element, a thermostat can control the amount of heat needed, depending on the season.
WALL
SWITCH
PLUNGER/ROLLER
SWITCH
VARIABLE
SPEED ON/OFF SWITCH
FAN/HEAT
SWITCH
Example output:
With no air curtain:
Heat lost: 1,585,898 BTU/ HR Cost of heat lost: $ 4,381.04/Season
The air curtain will save a minimum of 70% of the heat from being lost:
Heat saved: 1,110,128 BTU/ HR
Cost of heat saved: $ 3,066.73/Season
Cost of air curtain operation: $ 101.83/Season
The installed cost of the air curtain is: $ 3,570.00
The resulting payback period will be: 1.2 years
lutionary
vo
e
R
Air Curtain with
ODYNAMIC
AER
Compression Chamber
Generating
FECT”
DA EF
“COAN
Air Movement
REMOTE MOUNT
THERMOSTAT
DISCONNECT
SWITCH
MAGNETIC REED
SWITCH
HIGH/LOW/OFF
SWITCH
MOTION SENSOR
6
Page 7
Mounting Options
How the Air Curtain is mounted depends on your doorway opening and what equipment or obstructions are in the way. If none of the methods
hown below suit your application, please call us at 1-800-888-9750.
s
ur engineers will provide solutions to your mounting problems.
O
NEW
Standard
Wall
Mount
Ceiling Mount
with
Threaded Rods*
Mounting Plate
(Optional)
ote: A Mounting Plate is
N standard equipment with the Air-Pro Unit and is the only method of mounting.
Extension Bars
(Optional)
with Threaded Rods*
on Standard
Roll-Up Door
Wall
Mounting
Brackets
Vertical
Mounting
for
Low Ceilings
or No Space
Above
Header
Optional
Side Baffles:
Clear flexible PVC material
mounted on
ded
stud
strip door
hardware
Extension Plates
with Threaded Rods*
on Standard
Overhead Door
Threaded Rods provided by others.
*
Wall Mounting
Brackets with
Threaded Rods*
on Standard
Roll-Up Door
TANDEM MOUNTING
If your doorway opening is wider than the desired model allows, two units can be mounted side-by-side to create a protective wall of air
IMPORTANT: We recommend that any mounting should be performed by a professional or certified contractor
to assure the unit is tightly secured and complies with all safety codes
.
7
Page 8
IN-CEILING MOUNT SERIES – S-ICM
For environmental control and personnel comfort
for ceilings up to 10’ high.
APPLICATIONS
Office Entrances
Vestibules
Retail and Commercial Entrances
Hospital Entrances
Restaurant and Food Service
Entrances
Hotels, Casinos, Resort
Entrances
Schools
Service and Customer
Entrances
Revolutionary
r Cu
i
A
AER
Compression Chamber
Generating
“COANDA EFFECT”
i
A
OD
r Mo
n wi
i
ta
r
YNAMIC
emen
v
th
t
SIZES
36''
42''
48''
60''
72''
84''
96''
108''
FEATURES
1/2 horsepower, 2-speed motors
One-piece construction
Unit is concealed in the ceiling, flush with ceiling panels
Hinged service panel for cleaning and service
Aesthetically pleasing white or stainless steel finish blends
with traditional drop ceilings (optional custom colors available) Includes filters for improved air quality
Exceptionally low noise levels (51 dBA low speed)
No additional duct work or nozzle extension required
Electric, hot water, or steam heat optional
Single-phase or three-phase power
Two-year parts warranty for unheated units
(18 months for heated units)
IN-CEILING MOUNT SERIES – S-ICM
MODEL S-ICM-36-1-2S S-ICM-48-1-2S S-ICM-60-1-2S
Nozzle Width (in.)
Number of Motors 1 1 1
Horse Power per Motor
Motor Speed(s)
Max. FPM at Nozzle
Max. CFM at Nozzle
Avg. FPM at Nozzle. 1615 1450 1215 1085 970 870
CFM at Nozzle 1035 990 1125 1015 1115 1005 Outlet Vel. Uniformity (%)
Shipping Wt. Unheated (lbs.)
Heater kW 10 10 10
emp. Rise
T
Amp Draw
Amp Draw*240/1/60
Amp Draw
Amp Draw*240/3/60 24 24 48
Amp Draw*480/3/60 12 12 24
Shipping Wt. Heated
208/1/60 48.1 48.1 48.1
*
208/3/60
*
36 48 60
1/2
High Low High Low High Low
1960
1350
1800
1240
95%
180 200 230
29/33
41.6
27.7
190 210 240
1/2 1/2
1960 1800 1960 1800
1795
1650
92%
29/33
41.6 41.6
27.7
1845
1700
91%
29/33
27.7
120''
More than one power supply may be required.
*
8
Page 9
E
FRONT
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
B
NOZZLE WIDTH
Standard Amps per
Motor Voltages Motor
110, 1ø, 60 hz 2.5 208, 1ø, 60 hz 1.4
230, 1ø, 60 hz 1.4
460, 1ø, 60 hz 0.7
575, 1ø, 60 hz 0.6
D
IDE
S
S-ICM DIMENSIONS CHART
Model A B C D E
36'' 39" 36" 37.5" 16.75" 20.25" 48'' 51" 48" 49 .5" 16.75" 20.25" 60'' 63" 60" 61.5" 16.75" 20.25" 72'' 75" 72" 73.5" 16.75" 20.25" 96'' 99" 96" 97.5" 16.75" 20.25" 108'' 111" 108" 109.5" 16.75" 20.25" 120'' 123" 120" 121.5" 16.75" 20.25"
NEW
DESIGN
BENEFITS
Immediate energy savings –
payback in as little as two years
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Stops outside drafts, flying insects and
airborne pollutants
Increased visibility – no physical barrier
in the opening
Optional heated units provide supplemental heat,
increasing employee comfort
S-ICM-72-2-2S S-ICM-84-2-2S S-ICM-96-2-2S S-ICM-108-3-2S S-ICM-120-3-2S
72 84 96 108 120
22233
1/2 1/2 1/2 1/2 1/2
High
1960
2695 2475 3145 2885 3595 3300 4045 3715 4495 4125
1615 1450 1385 1245 1215 1085 1615 1450 1465 1315
2225 1995 2155 1950 2235 2000 3335 2990 3325 2925
Low
1800
95% 93% 92% 92% 95%
350 370 380 525 540
20 20 20 30 30
29/33 29/33 29/33 29/33 29/33
N/A
N/A
55.4 55.4 55.4 83.1 83.1
48 48 48 72 72
24 24 24 36 36
360 380 395 535 560
High Low High Low High Low High Low
1960
1800
N/A N/A N/A N/A
N/A
1960 1800 1960 1800 1960 1800
N/A
N/A N/A
ACTIVATION DEVICES
OPTIONAL
WALL
SWITCH
FAN/HEAT
SWITCH
MAGNETIC REED
SWITCH
9
Page 10
AIR-PRO SERIES – S-AP
For interior mounting only with door heights up to 7'
NSF
CERTIFIED
®
APPLICATIONS
Bakeries
Breweries
Cafeterias
Restaurants
Supermarkets
Warehouses
• Hotels/ Motels
Cold Storage Facilities
Convenience Stores
Commercial Kitchens
Distribution Centers
Fast Food Restaurants
Food Processing Plants
Employee Entrances
SIZES
36''
42''
48''
60''
FEATURES
1
/3 horsepower motors
Housing, grill and nozzle are 304 series stainless steel
Aluminum blower wheels
Built-in high/low switch for 2-speed motors
Heavy-duty directional vane
Voltage: 120V, single-phase, plug-in unit
NSF certified up to 7' interior mounting height
One-year warranty on parts
Low noise levels (67 dBA)
Separate mounting plate for easy installation
BENEFITS
Substantially reduces energy costs
Blocks outside drafts, flying insects and airborne pollutants
Re-circulates warm air inside the building
Smaller units perfect for take-out service windows
72''
10
AIR-PRO SERIES – S-AP
MODEL
Nozzle Width (in.)
Diameter of Wheel (in.) 5.5 5.5 5.5 5.5 5.5
Voltage 110-120 110-120 110-120 110-120 110-120
Frequency (Hz) Net Weight. (lbs.) 43 47 62 75 86
No. of Motor(s) 1 1 1 1 2 Motor Speeds Capacity (kw) Maximum Air Speed (fpm) 3150 2560 3150 2560 3150 2560 3150 2560 3150 2560
olume (cfm) 1220 990 1360 1100 1860 1520 2330 1890 2440 1980
Air V Sound Level (dBA)
AP-2-36-1-SS AP-2-42-1-SS AP-2-48-1-SS AP-2-60-1-SS AP-4-72-2-SS
34.50
60
Low High Low High Low High Low High Low
High
.495
.500
67
69
38.50
60 60 60 60
.645
.650
69
71
46.25
.650 .645 .800 .795 1.00 0.99
73 71 75 73 75 73
58.00
69.50
Page 11
STANDARD
A
H
I
EQUIPMENT
D
B
Model A B C D E F G H I J
AP-2-36-1-SS 35.5'' 1.0'' 11.5 '' 22 '' 2'' 5.75'' 10'' 8.5'' 5''
AP-2-42-1-SS 39.5'' 1.0'' 11.5 '' 22 '' 2'' 5.75'' 10'' 8.5'' 5''
AP-2-48-1-SS 47.25'' 1.0'' 17 .0 '' 28'' 17 .5'' 2'' 5.75'' 10'' 8.5'' 5''
AP-2-60-1-SS 59'' 1.0'' 22.5'' 33.5'' 22.5'' 2'' 5.75'' 10'' 8.5'' 5''
AP-2-72-2-SS 69.5'' 1.5'' 22.0'' 46.0'' 22.0'' 2'' 5.75'' 10'' 8.5'' 5''
C
S-AP DIMENSIONS CHART
Stainless Steel
Intake Grill
E
Aluminum
Blower Wheels
B
G
F
Stainless Steel
Housing
J
All Air-Pro Air Curtains run on 120 volts and have single-phase motors, which means they plug into a regular grounded wall outlet for quick and easy installation.
An Automatic Door Plunger Switch is supplied with every unit. This switch allows the air curtain to be instantly turned on when the door is opened.
Easy Adjustments
The Air-Pro Series Air Curtains are easy to operate. Each unit has a 2-speed motor with a built-in high/low rocker switch. There is also an adjustable directional vane that allows you to regulate the direction of the air flow
.
Stainless Steel
Mounting Plate
All models of our
Air-Pro
Air Curtains are listed in our
Quick Ship Stocking Program,
which means the item will ship
the same day the order is
placed
.
NSF
®
CERTIFIED
11
Page 12
COMMERCIAL FRONT DOOR SERIES – S-CFD
For environmental control up to 10’ high
Fast Food Take-Out Window
APPLICATIONS
Climate and Environmental Control
Office and Employee Entrances
Interoffice and Commercial Separation
Hospital Entrances and Hallways
Retail and Commercial Entrances
Restaurant and Food Service
Entrances
Hotel, Resort, and Casino
Entrances
utionary
l
vo
e
R
Air Curtain with
ODYNAMIC
AER
Compression Chamber
Generating
ECT”
F
DA EF
“COAN
Air Movement
SIZES
36''
42''
48''
60''
72''
84''
96''
108''
FEATURES
1/2 horsepower, 2-speed motors
Aluminized steel, one-piece construction
Unmatched air flow uniformity
Optional filters for improved air quality
Exceptionally low noise levels (53/51 dBA)
Electric, hot water, or steam heat optional
Single-phase or three-phase power
Two-year parts warranty for unheated units
(18 months for heated units)
COMMERCIAL FRONT DOOR SERIES – S-CFD
MODEL S-CFD-36-1-2S S-CFD-42-1-2S S-CFD-48-1-2S
Nozzle Width (in.)
Number of Motors 1 1 1
Horse Power per Motor
Motor Speed(s)
Max. FPM at Nozzle 1960 1800 1960 1800 1960 1800
Max. CFM at Nozzle 1350 1240 1575 1445 1795 1651
vg. FPM at Nozzle.
A
CFM at Nozzle 1035 990 1110 995 1125 1010 Outlet Vel. Uniformity (%)
Shipping Wt. Unheated (lbs.)
Heater kW 10 10 10
emp. Rise
T
Amp Draw
Amp Draw*240/1/60 41.6 41.6 41.6
Amp Draw*208/3/60 27.7 27.7 27.7
Amp Draw*240/3/60
Amp Draw*480/3/60 12 12 12
Shipping Wt. Heated 95 105 115
208/1/60
*
36 42 48
High
1/2
Low
48.1
1/2
High
1615 1450 1385 1245 1215 1085
Low High
95% 93% 92%
90 100 110
29/33
48.1
24 24 24
1/2
Low
29/33 29/33
48.1
120''
12
More than one power supply may be required.
*
Page 13
RONT
F
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
E
D
S-CFD DIMENSIONS CHART
Model A B C D E
36'' 37" 36" 36.0625" 15" 15.375" 42'' 43" 42" 42.0625" 15" 15.375" 48'' 49" 48" 48.0625" 15" 15.375" 60'' 61" 60" 60.0625" 15" 15.375" 72'' 73" 72" 72.0625" 15" 15.375" 84'' 85" 84" 84.0625" 15" 15.375"
96'' 97" 96" 96.0625" 15" 15.375" 108'' 109" 108" 108.0625" 15" 15.375" 120'' 119" 118" 120.0625" 15" 15.375"
B
NOZZLE WIDTH
Standard
Motor Voltages Motor
110, 1ø, 60 hz 2.5
208, 1ø, 60 hz 1.4
230, 1ø, 60 hz 1.4
460, 1ø, 60 hz 0.7
575, 1ø, 60 hz 0.6
Amps per
BENEFITS
Immediate energy savings – payback period
as little as two years
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Blocks outside drafts, flying insects and
airborne pollutants
Increased visibility – no physical barrier
in the opening
S-CFD-60-2-2S S-CFD-72-2-2S S-CFD-84-2-2S S-CFD-96-2-2S S-CFD-108-3-2S S-CFD-120-3-2S
60 72 84 96 108 118
222233
1/2
High Low High Low High Low High Low High Low High Low
1960 1800 1960 1800 1960 1800 1960 1800 1960 1800 1960 1800
2400
1455 1305 1615 1450 1385 1245 1215 1085 1615 1450 1465 1305
1665 1495 2220 1995 2155 1950 2235 2000 3335 2990 3325 2985
2320
95% 95% 93% 92% 92% 95%
145 170 190 200 250 275
15
29/33
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
41.6 55.4 55.4 55.4 83.1 83.1
36 48 48 48 72 72
18 24 24 24 36 36
150 180 200 210 265 290
1/2
2700 2475 3145 2885 3595 3300 4045 3710 4495 4125
20
29/33
1/2
20 20 30 30
29/33
1/2
29/33
1/2
29/33
29/33
13
Page 14
INSECT BACK DOOR SERIES – S-IBD
For insect control up to 10’ high
APPLICATIONS
Insect and Wind Control
Restaurant and Food Service
Back Doors
Hotel, Resort, and Casino Back Doors
Auto Body and Open Bays
Paint Booths
SIZES
36''
42''
48''
60''
72''
84''
96''
FEATURES
3/4 horsepower motors
Aluminized steel, one-piece construction
Optional filters for improved air quality
Unmatched air flow uniformity
Exceptionally low noise levels (63 dBA low speed)
Electric, hot water, steam heat, or indirect gas heat optional
Single-phase or three-phase power
Two-year parts warranty for unheated units
(18 months for heated units)
108''
120''
14
y
r
tiona
u
vol
e
R Air Curtain with AERODYNAMIC
Compression Chamber
Generating
ECT
F
DA EF
“COAN
Air Movement
INSECT BACK DOOR SERIES – S-IBD
MODEL
Nozzle Width (in.)
Number of Motors 1 1 1
Horse Power per Motor
Max. FPM at Nozzle
Max. CFM at Nozzle 2985 3485 3980
Avg. FPM at Nozzle. 3805 3265 2855
CFM at Nozzle 2615 2610 2635
el. Uniformity (%)
Outlet V
Shipping Wt. Unheated (lbs.)
S-IBD-36-1
36
3/4 3/4 3/4
4345
95% 93% 92%
95
S-IBD-42-1
42
4345
100
Consult factory for electric heat
S-IBD-48-1
48
4345
110
Page 15
RONT
F
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
B
NOZZLE WIDTH
E
IDE
D
S
S-IBD DIMENSIONS CHART
Model A B C D E
36'' 37" 36" 36.0625" 15" 15.375" 42'' 43" 42" 42.0625" 15" 15.375" 48'' 49" 48" 48.0625" 15" 15.375" 60'' 61" 60" 60.0625" 15" 15.375" 72'' 73" 72" 72.0625" 15" 15.375" 84'' 85" 84" 84.0625" 15" 15.375"
96'' 97" 96" 96.0625" 15" 15.375" 108'' 109" 108" 108.0625" 15" 15.375" 120'' 119" 118" 120.0625" 15" 15.375"
Standard Amps per
BENEFITS
Motor Voltages Motor
110, 1ø, 60 hz 8.0
208, 1ø, 60 hz 3.6
230, 1ø, 60 hz 3.6
460, 1ø, 60 hz 2.0
575, 1ø, 60 hz 1.5
S-IBD-60-2
60
2
3/4 3/4 3/4 3/4 3/4 3/4
4345 4345 4345 4345 4345 4345
5200
3415 3800 3265 2855 3815 3270
3925 5235 5215 5235 7850 7845
95% 95% 93% 92% 95% 94%
155 175 195 210 260 285
S-IBD-72-2 S-IBD-84-2 S-IBD-96-2 S-IBD-108-3 S-IBD-120-3
72
2
5975
84
2
6965 7965 8965 9960
Immediate energy savings – payback period
as little as two years
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Stops outside drafts, flying insects,
and airborne pollutants
Increase visibility – no physical barrier in the opening
96
2
108 118
3
3
15
Page 16
LOW PROFILE COMMERCIAL SERIES – S-LP
For environmental control and personnel comfort up to 10’ high.
8.5''
Fast Food Take-Out Window
APPLICATIONS
Drive-Thru Windows
Concession Stands
Patios
Office and Employee
Entrances Interoffice and Commercial
Separation
Hospital Entrances and
Hallways
Retail and Commercial
Entrances
Restaurant and Food Service
Entrances
Restaurant Smoking Areas
Hotels, Casinos, Resort
Entrances
lutionary
vo
e
Walk-in Coolers
Paint Booths
Schools
R
Air Curtain with
AERODYNAMIC
Compression Chamber
Generating
DA EF
“COAN
Air Movement
FECT”
SIZES
30''
36''
48''
60''
72''
84''
96''
108''
FEATURES
1/5 horsepower, variable-speed motors
Stainless steel, one-piece construction
Low profile design – only 8.5” high
Unmatched air flow uniformity
Includes filters for improved air quality
Exceptionally low noise levels (53 dBA low speed)
Electric, hot water, or steam heat optional
Single-phase or three-phase power
Two-year parts warranty for unheated units
(18 months for heated units)
Includes threaded inserts for top mounting
OFILE COMMERCIAL
W PR
LO
MODEL S-LP-30-1-VS S-LP-36-1-VS S-LP-42-1-VS
Nozzle Width (in.)
Number of Motors 1 1 1
Horse Power per Motor 1/5 1/5 1/5
Max. FPM at Nozzle
vg. FPM at Nozzle.
A
CFM at Nozzle Outlet Vel. Uniformity (%)
Shipping Wt. Unheated (lbs.)
Heater kW 8 8 8
Temp. Rise 24 22 20
Amp Draw
Amp Draw*240/1/60 33.3 33.3 33.3
Amp Draw*208/3/60
Amp Draw
Amp Draw*480/3/60 9.6 9.6 9.6
Shipping Wt. Heated 50 60 70
208/1/60 38.5 38.5 38.5
*
240/3/60
*
29 35 41
3100
2100
925
92% 95% 95%
45
22.2
19.3
SERIES – S-LP
3100
2200
1215 1380
55 65
22.2 22.2
19.3
3100
2150
19.3
120''
16
More than one power supply may be required.
*
Page 17
FRONT
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
B
NOZZLE WIDTH
E
D
S-LP DIMENSIONS CHART
Model A B C D E
30'' 31" 29" 30" 8.5" 11.875" 36'' 37" 35" 36" 8.5" 11.875" 42'' 43" 41" 42" 8.5" 11.875" 48'' 49" 47" 48" 8.5" 11.875" 60'' 61" 59" 60" 8.5" 11.875" 72'' 73" 71" 72" 8.5" 11.875" 84'' 85" 83" 84" 8.5" 11.875"
96'' 97" 95" 96" 8.5" 11.875" 108'' 109" 107" 108" 8.5" 11.875" 120'' 121" 119" 120" 8.5" 11.875"
BENEFITS
Standard Amps per
Motor Voltages Motor
110, 1ø, 60 hz 4.4 208, 1ø, 60 hz 2.0
230, 1ø, 60 hz 2.0
460, 1ø, 60 hz 1.1
575, 1ø, 60 hz 0.9
Immediate energy savings – payback period
as little as two years
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Blocks outside drafts, flying insects and
airborne pollutants
Increased visibility – no physical barrier
in the opening
Heated units provide supplemental heat,
increasing employee comfort
S-LP-48-1-VS S-LP-60-1-VS S-LP-72-2-VS S-LP-84-2-VS S-LP-96-2-VS S-LP-108-2-VS S-LP-120-2-VS
47 59 71 83 95 107 119
1122222
1/5 1/5 1/5 1/5 1/5 1/5 1/5
3100 3100 3100 3100 3100 3100 3100
2100 1985 2200 2150 2100 2200 2175
1545 1820 2425 2760 3095 3640 3970
92%
70
16 16 16 24 32 32 32
33 29 22 29 33 29 27
N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
44.5 44.5 44.5 66.7 88.9 88.9 88.9
38.5
19.3 19.3 19.3 28.9 38.5 38.5 38.5
85 95 105 120 125 145 160
92% 95% 95% 95% 95% 95%
90
38.5
100
38.5
115 120 140 150
57.8
77.1
77.1
77.1
17
Page 18
LIGHT INDUSTRIAL SERIES – S-LI
For environmental control up to 12' high and insect control on industrial openings up to 10' high.
Note: One piece units
SIZES
36''
42''
48''
60''
72''
84''
for 14’ and 16’
wide openings
available.
For specifications consult factory.
96''
108''
120''
132''
144''
APPLICATIONS
Loading Docks
Internal Warehouse Openings
Shipping and Receiving Doors
Distribution Centers
Food Processing
Meat Processing
Auto Body and
Open Bays
MODEL
Nozzle Width (in.)
Number of Motors
Horse Power per Motor
Motor Speed(s) High Low High Low High Low High Low High Low
Max. FPM at Nozzle 4345 2920 4345 2920 4345 2920 4345 2920 4345 2920
Max. CFM at Nozzle 2985 2005 3485 2345 3985 2680 4505 2875 5200 3350
Avg. FPM at Nozzle. 3805 2560 3260 2195 2855 1920 2285 1535 3415 2295
CFM at Nozzle Outlet Vel. Uniformity (%)
Shipping Wt. Unheated (lbs.)
Heater kW
emp. Rise
T
Amp Draw 208/1/60 48.1 48.1 48.1 48.1 N/A
Amp Draw 240/1/60 41.6 41.6 41.6 41.6 N/A
Amp Draw 208/3/60 27.7 27.7 27.7 27.7 41.6
Amp Draw 240/3/60 24 24 24 24 36
Amp Draw 480/3/60
Shipping Wt. Heated
Paint Booths
Car Washes
Walk-In Coolers
Conveyor Openings
FEATURES
3/4 horsepower dual-speed motors
Stainless steel, one-piece construction
Optional filters for improved air quality
Unmatched air flow uniformity
Exceptionally low noise levels (56 dBA low speed)
Electric, hot water, steam heat or indirect gas heat optional
Single-phase or three-phase power
Two-year parts warranty for unheated units
Revolutionary Air Curtain with AERODYNAMIC
Compression Chamber
Generating
“COANDA EFFECT”
Air Movement
(18 months for heated units)
LIGHT INDUSTRIAL SERIES – S-LI
S-LI-36-1-2S S-LI-42-1-2S S-LI-48-1-2S S-LI-60-1-2S S-LI-60-2-2S
36 42 48 60 60
1
3/4
2620
1760 2605 1745 2635 1770 2603 1755 3925 2640
95%
95 100 110 120 155
10 10 10 10 15
13/19
12
100
11 1 2
3/4
93%
13/19 13/19 13/19 13/19
12
105
3/4
92%
12
115
3/4 3/4
91%
12 18
125
94%
165
18
Heated units are for interior mounting only
Page 19
FRONT
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
E
D
S-LI DIMENSIONS CHART
Model A B C D E
36" 37" 36" 36.0625" 15" 15.375" 42" 43" 42" 42.0625" 15" 15.375" 48" 49" 48" 48.0625" 15" 15.375" 60" 61" 60" 60.0625" 15" 15.375" 72" 73" 72" 72.0625" 15" 15.375" 84" 85" 84" 84.0625" 15" 15.375"
96" 97" 96" 96.0625" 15" 15.375" 108" 109" 108" 108.0625" 15" 15.375" 120" 119" 118" 120.0625" 15" 15.375" 132" 134" 133" 133.0625" 15" 15.375" 144" 146" 145" 145.0625" 15" 15.375"
B
NOZZLE WIDTH
Motor Voltages in Amps /Motor
Voltage Amps/Motor Phase Hz
110 8.0
208/230 3.6
460 2.0 575 1.5
VELOCITY PROFILE
Model from Nozzle Velocity(fpm)
S-LI-96-2-2S 3’ 2304
S-LI-72-2-2S S-LI-84-2-2S S-LI-96-2-2S S-LI-108-3-2S S-LI-120-3-2S S-LI-132-3-2S S-LI-144-4-2S
72 84 96 108 118 133 145
2223334
3/4 3/4 3/4 3/4 3/4 3/4 3/4
High Low High Low High Low High Low High Low High Low High Low
4345 2920 4345 2920 4345 2920 4345 2920 4345 2920 4345 2920 4345 2920
5975
3800 2560 3265 2240 2855 1920 3810 2560 3270 2195 2880 1940 3810 2560
5235 3520 5215 3485 5235 3529 7850 5285 7840 5280 7815 5255 10470 7045
4020
95% 93% 92% 95% 94% 94% 95%
180 195 210 255 290 300 350
20 20 20 30 30 30 40
13/19
N/A
N/A N/A N/A N/A N/A N/A N/A
41.6
48
24 24 24 36 36 36 48
190 205 225 270 300 310 370
Distance Avg. Core
6’ 1679
10’ 1762
6970 4690 7975 5360 8965 6030 9960 6695 11175 7370 11955 8040
13/19
N/A
55.4 55.4 83.1 83.1 83.1 110.80
48
160
13/19
N/A
48
BENEFITS
Immediate energy savings – payback in
as little as two years
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Blocks outside drafts, flying insects
and airborne pollutants
Increased visibility – no physical barrier in the opening
Heated units provide supplemental heat,
increasing employee comfort
13/19
N/A
72 72 72 96
13/19
N/A
13/19 13/19
N/A
N/A
19
Page 20
MEDIUM INDUSTRIAL SERIES – S-MI
For environmental control up to 14’ high and insect control on industrial openings up to 12’ high.
Note: One piece units
SIZES
36''
48''
60''
72''
84''
96''
for 14’ and 16’
wide openings
available.
For specifications consult factory.
108''
120''
132''
144''
APPLICATIONS
Loading Docks
Internal Warehouse Openings
Shipping and Receiving Doors
Distribution Centers
Food Processing
Meat Processing
Auto Body and Open Bays
Paint Booths
Car Washes
alk-In Coolers
W
Industrial Ovens
Conveyor Openings
MODEL S-MI-36-1 S-MI-42-1 S-MI-48-1 S-MI-60-1 S-MI-60-2
Nozzle Width (in.)
Number of Motors 1 1 1 1 2
Horse Power per Motor
Max. FPM at Nozzle 5085 5085 5085 5085 5085
Max. CFM at Nozzle Avg.
FPM at Nozzle
CFM at Nozzle 3065 3065 3065 3065 5375 Outlet Vel. Uniformity (%)
Shipping Wt. Unheated (lbs.)
FEATURES
1 horsepower motors
Stainless steel, one-piece construction
Exceptionally low noise levels (64 dBA)
Unmatched air flow uniformity
Electric, hot water, steam heat or indirect gas heat optional
Single-phase or three-phase power
Two-year parts warranty for unheated units
Air Curtain with
AERODYNAMIC
Compression Chamber
“COANDA EFFECT”
(18 months for heated units)
MEDIUM DUTY INDUSTRIAL SERIES – S-MI
36 42 48 60 60
1
3500 4075 4665 5275 6090
4450
95% 93% 92% 91% 94%
120 125 130 140 170
1
3815
1
3340
1
2675 3995
Revolutionary
Generating
Air Movement
1
20
Page 21
FRONT
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
B
NOZZLE WIDTH
E
D
S-MI DIMENSIONS CHART
Model A B C D E
36" 37" 36" 36.0625" 15" 15.375" 42" 43" 42" 42.0625" 15" 15.375" 48" 49" 48" 48.0625" 15" 15.375" 60" 61" 60" 60.0625" 15" 15.375" 72" 73" 72" 72.0625" 15" 15.375" 84" 85" 84" 84.0625" 15" 15.375"
96" 97" 96" 96.0625" 15" 15.375" 108" 109" 108" 108.0625" 15" 15.375" 120" 119" 118" 120.0625" 15" 15.375" 132" 134" 133" 133.0625" 15" 15.375" 144" 146" 145" 145.0625" 15" 15.375"
Motor Voltages in Amps /Motor
Voltage Amps/Motor Phase Hz
110 9.3
208/230 4.2
460 2.4 575 1.8
VELOCITY PROFILE
Model from Nozzle Velocity(fpm)
S-MI-48-1 3’ 4226
S-MI-72-2 S-MI-84-2 S-MI-96-2 S-MI-108-3 S-MI-120-3 S-MI-132-3 S-MI-144-4
72 84 96 108 118 133 145
22233 34
11111 11
5085 5085 5085 5085 5085 5085 5085
6990
4445 3825 3345 4460 3830 3375 4460
7165
95%
195 210 230 275 300 325 360
Distance Avg. Core
6’ 2988
10’ 2314
8160
7165 7165 10750 10750 10750 14335
93%
160
9325
92%
BENEFITS
Immediate energy savings – quick payback period
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Blocks outside drafts, flying insects
and airborne pollutants
Increased visibility – no physical barrier in the opening
10500
95% 94% 94% 95%
11675
13075
13990
21
Page 22
HEAVY DUTY INDUSTRIAL SERIES – S-HD
For environmental control up to 18' high and insect control
n industrial openings up to 14' high.
o
SIZES
48''
60''
72''
96''
108''
Revolutionary Air Curtain with AERODYNAMIC
Compression Chamber
Generating
“COANDA EFFECT”
Air Movement
120''
132''
144''
1
56''
168''
180''
APPLICATIONS
Loading Docks
Internal Warehouse Openings
Shipping and Receiving Doors
Auto Body and Open Bays
Paint Booths
utomotive Openings
A
MODEL S-HD-36-1 S-HD-48-1 S-HD-60-1 S-HD-72-2 S-HD-84-2
Nozzle Width (in.)
Number of Motors 1 1 1 2 2
Horse Power per Motor 3 3 3 3 3
Power Rating (kW)
Max. FPM at Nozzle
vg. Outlet V
A
CFM at Nozzle 3198 3205 3206 6396 6402 Outlet Vel. Uniformity (%)
Shipping Wt. Unheated (lbs.)
elocity FPM
FEATURES
3 horsepower totally enclosed air over motors
Stainless steel, one-piece construction
Exceptionally low noise levels (72 dBA)
Electric, hot water, steam heat or indirect gas heat optional
Three-phase power
Two-year parts warranty for unheated units
(18 months for heated units)
HEAVY DUTY INDUSTRIAL SERIES – S-HD
36 48 60 72 84
2.0 2.0 2.0 4.0 4.0
5750
4652
95% 92% 91% 95% 93%
95
5750
3496
109 122 174 192
5750 5750 5750
2798
4651 3991
22
Page 23
FRONT
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
B
NOZZLE WIDTH
Motor Voltages in Amps /Motor
Standard Voltages
S-HD HP 208 230 460 575 Phase Hz
3 7.8 7.4 3.7 3.1 3 60
E
D
S-HD DIMENSIONS CHART
Model A B C D E
36" 37" 36" 36.0625" 15" 15.375" 48" 49" 48" 48.0625" 15" 15.375" 60" 61" 60" 60.0625" 15" 15.375" 72" 73" 72" 72.0625" 15" 15.375" 84" 85" 84" 84.0625" 15" 15.375"
96" 97" 96" 96.0625" 15" 15.375" 108" 109" 108" 108.0625" 15" 15.375" 120" 119" 118" 120.0625" 15" 15.375" 132" 134" 133" 133.0625" 15" 15.375"
144" 146" 145" 145.0625" 15" 15.375" 156" 158" 157" 157.0625" 15" 15.375" 168" 170" 169" 169.0625" 15" 15.375"
VELOCITY PROFILE
Distance Avg. Core
Model f
S-HD
rom Nozzle Velocity(fpm)
3’ 4778 8’ 2926
12’ 2389
BENEFITS
Immediate energy savings – quick payback period
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Blocks outside drafts, flying insects and airborne pollutants
Increased visibility – no physical barrier in the opening
Heated units provide supplemental heat,
increasing employee comfort
S-HD-96-2 S-HD-108-3 S-HD-120-3 S-HD-132-3 S-HD-144-4 S-HD-156-4 S-HD-168-4
96 108 118 133 145 157 169
2
33333 33
4.0 6.0 6.0 6.0 8.0 8.0 8.0
5750
3496 4651 4259 3838 4651 4321 3991
6410
92%
208 250 279 285 353 366 384
3334 44
5750
9594
95%
5750
9598 9602 12792 12798 12804
94%
5750
94%
5750
95% 94% 93%
5750
5750
23
Page 24
EXTRA HEAVY DUTY INDUSTRIAL SERIES – S-XHD
For environmental control up to 22' high and insect control on industrial openings up to 20' high.
SIZES
48''
60''
72''
96''
108''
Revolutionary Air Curtain with AERODYNAMIC
Compression Chamber
Generating
“COANDA EFFECT”
Air Movement
120''
132''
144''
156''
168''
180''
1
92''
APPLICATIONS
Loading Docks
Internal Warehouse Openings
Shipping and Receiving Doors
Auto Body and Open Bays
aint Booths
P
Automotive Openings
EXTRA HEAVY DUTY INDUSTRIAL SERIES – S-XHD
MODEL S-XHD-48-1 S-XHD-60-1 S-XHD-72-1 S-XHD-96-2 S-XHD-108-2
Nozzle Width (in.)
Number of Motors
Horse Power
Max. FPM at Nozzle 6770 6770 6770 6770 6770
vg. FPM at Nozzle
A
CFM at Nozzle 6495 7700 9535 13365 14185
el. Uniformity (%)
Outlet V
Shipping Wt. Unheated (lbs.)
FEATURES
5 horsepower totally enclosed air over motors
Stainless steel, one-piece construction
Exceptionally low noise levels (71 dBA)
Electric, hot water, steam heat or indirect gas heat optional
Three-phase power
Two-year parts warranty for unheated units
(18 months for heated units)
48 60 72 96 108
1
5
5665
92% 91% 95% 92% 95%
400
1122
5
4490
435 450 765 795
5
5285
55
4990
4745
24
Page 25
FRONT
A
OVERALL WIDTH
TOP
C
MOUNTING WIDTH
BOTTOM
B
NOZZLE WIDTH
Motor Voltages in Amps /Motor
Standard Voltages
S-XHD HP 208 230 460 575 Phase Hz
3 17.1 15.8 7.9 6.3 3 60
E
D
S-XHD DIMENSIONS CHART
Model A B C D E
48" 51" 48" 47" 21" 27.25" 60" 63" 60" 59" 21" 27.25" 72" 75" 72" 71" 21" 27.25"
96" 99.12" 96.12" 95.12" 21" 27.25" 108" 111.12" 108.12" 107.12" 21" 27.25" 120" 123.12" 120.12" 119.12" 21" 27.25" 132" 135.12" 132.12" 131.12" 21" 27.25" 144" 147.12" 144.14" 143.14" 21" 27.25" 156" 159.24" 156.24" 155.24" 21" 27.25" 168" 171.24" 168.24" 167.24" 21" 27.25" 180" 183.24" 180.24" 179.24" 21" 27.25"
192 " 195.24" 192.24" 191.24" 21" 27.25"
VELOCITY PROFILE
istance Avg. Core
odel from Nozzle Velocity (fpm)
M
S-XHD
D
4’ 3783 12’ 2184 18’ 1783
BENEFITS
Immediate energy savings – quick payback period
Prevents infiltration of cold or warm air, increasing
employee and customer comfort
Blocks outside drafts, flying insects and airborne pollutants
Increased visibility – no physical barrier in the opening
Heated units provide supplemental heat,
increasing employee comfort
S-XHD-120-2
120 132 144 144 156 168 180
2
55555 55
6770 6770 6770 6770 6770 6770 6770
4490 4490 4490 4820 4660 4490 4990
16225
94%
825 850 865 1155 1190 1220 1240
S-XHD-132-2
2
16605
94%
S-XHD-144-2
2
19745
95%
S-XHD-156-3
3
20865 23510 23695 24035
94%
S-XHD-168-3 S-XHD-180-3 S-XHD-192-3
3
93%
3
94%
3
93%
25
Page 26
Optional Equipment and Accessories
Control Panels
NEMA 4
otor control panels include
M the following components:
1. Transformer with fused primary
and secondary, providing
120 volts for control circuit
2. Three-phase contactor
3. Overload blocks for each motor
(3 phase motors only)
4. Terminal strip for easy field connection
5. Grounding lugs
6. Door mounted
on/off switch
(Optional)
6
1
2
3
To minimize field wiring, Save-T Air Curtains can be ordered with a pre-mounted control panel, located on either side of the housing. Due to space restrictions, remote-mounted control panels may be optional. Wires from each motor are run to a single junction box, elimi­nating the need for field motor wiring
Motor control panels substantially reduce field wiring. The control panels are recommended for all three­phase units. Fused disconnects can be included in the panel or supplied by others.
5
4
Heaters
Both industrial and commercial units can be ordered with either electric or hot water/steam heaters. In addition, industrial units are available with indirect gas-fired heaters. Heating coils warm the intake air to improve employee and customer comfort.
Electric
Hot Water
and
Steam
Indirect Gas-Fired
26
Page 27
Mounting Options
WALL MOUNTING PLATE
(Designed for S-AP, S-CFD, S-IBD,
S-LI, and S-MI Units)
This mounting method can be used when the base (large plate) can be securely attached to a wall made of wooden studs and dry wall material. The smaller bar is attached to the Air Curtain and lifted onto the base plate.
MOUNTING BARS
These “C” channel bars are used when obstructions interfere with normal wall mount­ing methods. (i.e. overhead door and roll-up door guide rails)
Filters
WALL BRACKETS
Wall brackets are required when a unit needs to be mounted away from the wall to clear obstacles or when the existing security door travels between the wall and the Air Curtain.
EXTENSION PLATES
Extension plates are recommended when the pre-drilled top mounting holes are too narrow for a ceiling suspension mount or wall bracket mount (not applicable for electric heated units).
VERTICAL
MOUNTING BRACES
These braces allow Air Curtains to be mounted vertically, creating a more efficient and effective air flow. This is common for refrigeration openings.
Nozzle Extensions
In environments where the intake air must be
clear of dust or grease, air filters should be used.
Our filters are made of aluminum mesh and are
washable with detergent and water
.
Nozzle extensions are typically used when the air
curtain is recessed above a ceiling. Each extension
is built with an adjustable vane that regulates the
direction of the air flow
.
27
Page 28
Mega-Pro Swinging Doors
otorized Accordion
M
Strip Doors
Service-Pro
Traffic Doors
Polar-Pro
Swinging Doors
Bulk Flexible PVC
ave-T Roll-Up Bug Screens
S
Strip Door Mounted on
Overhead Door Bracket
Every Application
Save-T Vinyl Roll-Up Doors
Flexible PVC Strip Doors
A Door for
and
Every Budget
Industrial Curtains and Enclosures
k Lights and F
Doc
railer Stands
T Dock Bumpers
Track Guards
d Posts
Bollar Machine Guards
Wheel Chocks
Dock Accessories
ns
a
M-Series Strip Door
28
RIP-A-STRIP
s
Read
Replacement Strips
y-to-Hang
on a Roll
TMI, LLC
Managing Environments™
5350 Campbells Run Road
Pittsburgh, PA 15205-9738
Bakery Rack Covers
800-888-9750
Tel: 412-787-9750
Fax: 412-787-3665
Web: www.tmi-pvc.com
E-Mail: customer-service@tmi-pvc.com
Copyright
Catalog Number AC-05-10
©
2010
Loading...