INSTALLATION INSTRUCTIONS
MODEL X2R
OWNER'S INSTRUCTIONS, DO NOT DESTROY
Copyright © 2014, Tjernlund Products, Inc. All rights reserved. P/N 8504202
THIS DEVICE MUST BE INSTALLED BY A
QUALIFIED PERSON.
READ INSTRUCTIONS CAREFULLY PRIOR TO
INSTALLATION AND OPERATION OF THE XCHANGER.
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547 Visit our web site • www.tjernlund.com
Page 2
1
TABLE OF CONTENTS
Descriptions and Specifications.......................................................................................................................................1
Installation Restrictions....................................................................................................................................................1
Cautions .......................................................................................................................................................................1-2
Recommended Methods and Patterns of Operation....................................................................................................2-3
Recommended Installation and Termination Locations................................................................................................3-4
X
CHANGER
TM
Installation..............................................................................................................................................4-6
Maintenance ....................................................................................................................................................................6
How to Obtain Service & Warranty ..............................................................................................................................6-7
Replacement Parts & Accessories ..................................................................................................................................7
X
CHANGER
TM
is a trademark of Tjernlund Products, Inc.
Tjernlund Products welcomes your comments and questions. Call us at (651) 426-2993, (800) 255-4208, Fax (651) 426-9547, email us at fanmail@tjfans.com or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.
DESCRIPTION
The XCHANGERTMmodel X2R is a dual fan mechanical ventilator capable of exhausting inside air, providing fresh outside air or provid­ing a balanced air exchange. The fans can be independently switched on or off or be easily reversed to provide fresh outside air or exhaust inside air. The X
CHANGER
TM
can be operated by a standard plug-in timer or Tjernlund’s optional DH2P dehumidistat control which operates the fan(s) based on the relative humidity sensed inside the home. The DH2P control includes an “On” setting that will operate the fan(s) continuously or it can be turned “Off” so the fan(s) do not operate during undesirable seasons.Tjernlund’s optional SCP speed control kit is also available to vary speed of fans if desired. See accessories on page 7.
X2R SPECIFICATIONS
GENERAL INFORMATION
Each XCHANGERTMis electrically factory line tested before shipment. After opening carton, Inspect thoroughly for hidden damage.
INSTALLATION RESTRICTIONS
WARNING: Improper installation, adjustment, alterations, service or maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information consult a qualified installer, service agency or the equipment supplier.
WARNING: Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
WARNING: Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed
combustion. Carbon monoxide poisoning may result. Use the DT2-6 6” duct take-off kit so exhaust can be removed from outside the mechanical room if necessary.
Observe proper location of hood as described on page 3. The X
CHANGER
TM
must only be installed with the hood on an exterior wall.
Do not discharge intake air onto water pipes or other equipment which may be affected by temperature extremes.
CAUTIONS
WARNING: Failure to install, maintain and/or operate the XCHANGERTMin accordance with manufacturer’s instructions may result in
conditions that can produce bodily injury and property damage.
MODEL X2R XCHANGER
Rough-in Wall Opening Dimensions:
13 1/4” x 6 1/2” Oval opening - utilize included template
8061034
FLEXIBLE TUBING
NOMINAL 6" DIAMETER
BY INSTALLER
1 FAN 2 FANS
Voltage 120 120
Watts 20
40
Amps 0.3
0.6
CFM 90
180
Page 3
2
Disconnect power supply to fans and/or accessory controls when reversing fan direction or servicing the XCHANGERTM. Failure to do so may result in personal injury and/or equipment damage.
Make certain the power source is adequate for the X
CHANGER
TM
requirements. Do not add the XCHANGERTMto a circuit where the
total electrical load is unknown.
TJERNLUND OPTIONAL DH2P DEHUMIDISTAT CONTROL MODULE OPERATION
The DH2P control module includes an adjustable dehumidistat control which activates the fan(s) if the relative humidity rises above the selected set-point. It is generally recommended to maintain a Relative Humidity (RH) below 60% to inhibit mold growth. The dehumidistat can be turned fully clockwise to the ‘on’ position for con­stant fan(s) operation or it can be turned fully counter-clockwise to ‘off’ during seasons or times when it is not desired for the X
CHANGER
TM
fan(s) to run. Each fan can be independently turned on/off by its fan switch on control
module.
STANDARD PLUG-IN TIMER OPERATION
A standard adjustable timer can also be utilized for timed operation of the XCHANGERTMfan(s). Plug timer into standard outlet and plug XCHANGERTMfans into wall timer.
TJERNLUND OPTIONAL SCP SPEED CONTROL OPERATION
Tjernlund’s optional SCP speed control can be used to vary the speed of the XCHANGERTMfans. Plug SCP speed control into stan­dard outlet and plug XCHANGERTMfans into SCP speed control.
RECOMMENDED PATTERNS OF OPERATION
If using the optional DH2P dehumidistat control, the X2R fans can be cycled automatically based on the relative humidity level of the house or it can be operated based on recommendations below. It is generally recommended to maintain a Relative Humidity (RH) below 60% to inhibit mold growth.
A standard plug-in wall timer can be programmed based on the lifestyle or needs of the occupants. For example, a family with smok­ers may want to cycle the X
CHANGER
TM
more frequently than a family of non-smokers.
Another timed method may be to cycle the X
CHANGER
TM
during peak usage of exhaust fans, such as bathroom, kitchen, laundry or
utility. Outdoor air should be brought in at these peak times to help balance out pressure inside the house.
The X
CHANGER
TM
can be cycled on and off at regular intervals to periodically provide fresh air to the home, exhaust stale air or have one fan bring air in and the other fan exhaust air for a balanced air exchange. It can also be ran like an economizer to bring outside air in during evening time when it is cooler outside.
HYPOTHETICAL XCHANGER OPERATION BASED ON LIFESTYLE
The example below shows a possible way in which cycling times of the XCHANGERTMmay be determined based on household occupant lifestyles.
6:00 A.M. to 9:00 A.M. = Outside fresh air should be brought into the house to compensate for morning routines. Bathing, cooking, laundry and other activities such as smoking necessitate that outside fresh air to be brought in. Depressurization of the house at these times is common with many exhaust fans running at one time.
9:00 A.M. to 4:00 P.M. = House is normally vacant with occupants at work or school. Cycle X
CHANGER
TM
on and off for 15 minute
intervals per hour to assure fresh air is supplied to the house.
4:00 P.M. to 8:00 P.M. = Outside fresh air should be brought into the house to compensate for evening routines. Bathing, cooking, laundry and other activities such as smoking necessitate that outside fresh air to be brought in. Depressurization of the house at these times is common with many exhaust fans running at one time.
8:00 P.M. to 6:00 A.M. = All members of the household are usually present. Outside fresh air is needed to dilute occupant generated carbon dioxide during sleeping. Cycle X
CHANGER
TM
on and off for 15 minute intervals, with occasional 30 minute intervals to assure
fresh air is supplied to house.
Page 4
XCHANGER OPERATION BASED ON AIR CHANGES PER HOUR
This method of operation can be used to supplement or provide for guaranteed air change rates. Table 1 shows the constant Cubic Feet Per Minute (CFM) of air necessary to produce the desired Air Change Per Hour rate (ACH), assuming natural infiltration of out­side air at a rate of .10 ACH. Square footage is determined by calculating the finished living space of the house. Garages and crawl space should not be included. The constant CFM figures shown assume that the living space has standard 8 foot ceilings.
1. Determine square footage of house living space on left hand column.
2. Pick desired air change rate from top row.
3. Locate intersection of these points to determine constant CFM that should be obtained to meet desired ACH.
The X
CHANGER
TM
will provide 180 CFM with both fans and 90 CFM with one fan operating. Where the CFM delivery of the XCHANG-
ER
TM
exceeds that listed in Table 1, a standard plug-in timer can be set so the XCHANGERTMis cycled to obtain the
desired ACH or Tjernlund’s optional SCP speed control may be used.
EXAMPLE
3000 square feet of living space
.2 ACH desired ventilation rate equals 40 CFM
X
CHANGER
TM
capacity of 90 CFM (with one fan running)
In this example the plug-in timer may be set so that the X
CHANGER
TM
operates for one half hour straight each hour or two fifteen
minute periods each hour.
RECOMMENDED INSTALLATION LOCATION
The XCHANGERTMmay be mounted anywhere in the house. Mount in a location where it is accessible for reversing fans seasonally or for maintenance.
WARNING: Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed
combustion. Carbon monoxide poisoning may result. Use the optional DT2-6 6” duct take-off kit so exhaust can be removed from outside the mechanical room if necessary.
It is required that the X
CHANGER
TM
be installed in a location where it will not be directed at the occupants. Do not discharge intake air
onto water pipes or other equipment which may be affected by temperature extremes.
Do not terminate adjacent to thermostat. Outside temperatures can disrupt normal thermostat operation.
Do not terminate within three feet from a barometric draft control or intake grille of a heating appliance.
XCHANGER HOOD TERMINATION CLEARANCES
Install XCHANGERTMin accordance with BOCA national Mechanical Codes M-306.1 and M-306.1.1 as follows, (See Diagram A).
M-306.1 LOCATION: Outside air exhaust and intake openings shall be located a minimum of 10 feet (3048mm) from lot lines or build­ings on the same lot. When openings front on a street or public way, the distance shall be measured to the centerline of the street or public way.
M-306.1.1 INTAKE OPENINGS: Outside air intake openings shall be located a minimum of 10 feet (3048mm) from any hazard or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks. When a source conta­minant is located within 10 feet (3048mm) of an intake opening, such opening shall be located a minimum of 2 feet (610mm) below the contaminant source.
IN ADDITION TO THESE CODES THE MANUFACTURER RECOMMENDS THAT:
• The X
CHANGER
TM
hood should be a minimum of 1 foot above grade or anticipated snow line.
• The X
CHANGER
TM
hood should be a minimum of 3 feet from an inside corner of the building.
3
TABLE 1
Page 5
4
INSTALLATION (TOOLS REQUIRED)
• Reciprocating saw • 5/16” nut runner or socket • Siding tools (dependent on exterior finish)
• Drill and 1/2” bit • Phillips screwdriver • Level
INSTALLATION
NOTE: Before cutting opening through wall, confirm XCHANGERTMhood termination clearances are met as noted on bottom of page 3.
1. A) Center X2R mounting template and tape to the rim joist between the floor joists/trusses X
CHANGER
TM
will be mounted through,
(See Diagram B).
B) If XCHANGERTMis not installed between floor joists or trusses, attach the template to the wall it will be exiting, ensuring
X
CHANGER
TM
will be level.
2. CAUTION: When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities. Using a 1/2” bit, drill pilot
holes noted on the template from inside through rim joist, wall board, siding, etc., keeping drill bit perpendicular to the wall. 1/2” bit must be long enough to penetrate through exterior.
3. Use a level to mark (4) holes drilled in step 2 and connect the holes on building exterior, (See Diagram C). Use provided X2R
oval template to align pilot holes and trace the remaining outline for opening. Use a saw to remove material between marks, (See Diagram D).
DIAGRAM B
DIAGRAM C
DIAGRAM D
CENTER AND LEVEL TEMPLATE BETWEEN JOISTS / TRUSSES OR PLACE ON WALL X2R XCHANGER WILL EXIT.
DRILL (4) 1/2” CORNER HOLES THROUGH WALL FROM INTERIOR AND CONNECT HOLES ON EXTERIOR WITH A LEVEL. ALIGN TEMPLATE WITH HOLES AND TRACE REMAINING LINES.
CUT OVAL TEMPLATE OPENING ALONG MARKED LINES.
DIAGRAM A
Page 6
4. Insert XCHANGERTMhood backing plate through exterior wall with collars on inside of house. IMPORTANT: Make sure backing plate bent flange is on top facing out, (See Diagram G). For vinyl or other types of lap siding, level backing plate and trace around edges. Trim siding back enough to install J channel or appropriate flashing, (See Diagram E).
5. Place a bead of caulk on back side of hood backing plate or building sheathing before inserting backing plate, (See Diagram F).
6. Insert X
CHANGER
TM
hood backing plate through exterior wall. NOTE: It may be desirable to attach flex duct to collars and feed into house to make it easier to attach duct to collars if mounting through rim joist. IMPORTANT: Make sure that hood backing plate bent flange is on top facing out, level and secure to wall using (4) 1” sheetrock screws, (See Diagram G).
7. Install J channel or appropriate flashing around X
CHANGER
TM
hood backing plate. Do not cover up hood backing plate or
hood may not fit in J channel, (See Diagram H).
8. Hook X2R hood on backing plate top bent flange, and install (4) 1/4” x 3/8” self tapping screws in bottom of hood through flange clearance holes to screw hood into backing plate, (See Diagram I).
9. Apply a bead of caulk around hood and siding, (See Diagram J).
10. Mount X2R Fan Assembly below or between joists / trusses to a cross brace or to a wall stud in any orientation with
(3) 5/16” x 1 1/4” screws on left, right and center mounting feet, (See Diagram K).
11. Use 6” flex duct to connect X
CHANGER
TM
hood to fan assembly collars. Firmly secure duct to collars with included zip ties. Insulated flex should be used in cold climates to prevent condensation. Properly support duct to minimize sagging, bends and sharp turns that may restrict air flow, (See Diagram L).
5
DIAGRAM E
DIAGRAM F
LEVEL XCHANGER HOOD BACKING PLATE AND TRACE FLANGE. TRIM SIDING BACK SO BACK­ING PLATE CAN BE MOUNTED FLUSH TO EXTE­RIOR SHEATHING.
PLACE A BEAD OF CAULK ON XCHANGER HOOD BACKING PLATE FLANGE OR BUILDING SHEATH­ING BEFORE INSERTING BACKING PLATE.
DIAGRAM H
INSTALL J CHANNEL OR APPROPRIATE FLASHING AROUND XCHANGER HOOD BACKING PLATE.
DIAGRAM K
MOUNT X2R BELOW OR BETWEEN JOISTS / TRUSSES TO A CROSS BRACE OR ON A STUD WALL IN ANY ORIENTATION. USE (3) 5/16” X 1 1/4” SCREWS ON LEFT, RIGHT AND CEN­TER MOUNTING FEET.
DIAGRAM L
FIRMLY SECURE DUCT TO COLLARS WITH INCLUDED ZIP TIES. INSULATED FLEX SHOULD BE USED IN COLD CLIMATES TO PREVENT CONDENSATION. PROPERLY SUPPORT DUCT TO MINIMIZE SAGGING, BENDS AND SHARP TURNS THAT MAY RESTRICT AIR FLOW. NOTE: USE OPTIONAL DT2-6 KIT IF DUCTING ON DISCHARGE.
DIAGRAM J
APPLY A BEAD OF CAULK AROUND HOOD AND SIDING..
DIAGRAM G
LEVEL HOOD BACKING PLATE AND SECURE TO WALL USING (4) SCREWS. IMPORTANT: MAKE SURE BENT FLANGE IS ON TOP FACING OUT.
DIAGRAM I
HOOK X2R HOOD ON BACKING PLATE TOP FLANGE. INSTALL (4) 1/4” X 3/8” SELF TAP­PING SCREWS IN BOTTOM HOOD FLANGE CLEARANCE HOLES TO SCREW HOOD INTO BACKING PLATE.
BENT FLANGE MUST BE ON TOP AND FACE OUT
Page 7
6
12. WARNING: Unplug fans from wall outlet or accessory controls when changing fan direction to prevent damage or injury. Insert fans in desired direction for either exhaust or intake. See arrow on bottom of fan cartridge or side of fan shroud for air flow direc­tion. Once installed confirm the air is being exhausted or supplied depending upon application, (See Diagram M). NOTE: Use optional DT2-6 kit if ducting on discharge side.
13. The X
CHANGER
TM
comes with (2) air infiltration magnetic draft stops to block incoming air during seasons or periods when the XCHANGERTMis not in use if desired. Place magnet(s) over XCHANGERTMfan opening(s) when fan is not in use to block air infiltra­tion. Place magnet(s) on side of XCHANGERTMcabinet so they are not lost if not in use to block fan openings, (See Diagram N).
MAINTENANCE
The XCHANGERTMhood screen must be inspected every 3 to 6 months. Remove any foreign material such as leaves, lint, cottonwood or other items. Remove screen to clean if necessary, (See Diagram O).
HOW HOW TO OBTAIN SERVICE ASSISTANCE
HOW TO OBTAIN SERVICE
1. If you have any questions about your XCHANGERTMor if it requires adjustment, repair or routine maintenance, we suggest that you contact your installer, contractor or service agency.
2. If you require technical information contact Tjernlund Products, Inc. at 1-800-255-4208 or email us at fanmail@tjfans.com.
When contacting Tjernlund Products, Inc., please have the following information available:
1. Model number and date code of the X
CHANGER
TM
2. Name and address of installer and service agency
3. Date of original installation and dates any service work was performed
4. Details of the problem
LIMITED PARTS WARRANTY AND CLAIM PROCEDURE
Tjernlund Products, Inc. warrants the components of the XCHANGERTMfor one year from date of installation. This warranty covers defects in material and workmanship. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. This warranty DOES NOT cover the complete X
CHANGER
TM
if it is operative,
except for the defective part.
Tjernlund Products, Inc. will issue credit or provide a free part to replace one that becomes defective during the one year warranty period. All receipts should include the date code of the X
CHANGER
TM
to ensure that the defective component corresponds with the
complete unit. This will help prevent possible credit refusal.
1.) Follow troubleshooting guide to determine defective component. If unable to determine faulty component, contact your
Tjernlund distributor, Tjernlund Products Technical Customer Service Department at 1-800-255-4208 for troubleshooting assistance or email us at fanmail@tjfans.com.
2.) After the faulty component is determined, return it to your Tjernlund distributor for replacement. Please include X
CHANGER
TM
date code component was taken from. Credit or replacement will only be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund.
DIAGRAM O
INSERT HOOD SCREEN IN HOOD GUIDES.
DIAGRAM M
WARNING: UNPLUG FANS WHEN CHANGING DIRECTION. SEE ARROW ON BOTTOM OF FAN CARTRIDGE OR SIDE OF FAN SHROUD FOR AIR FLOW DIRECTION. NOTE: USE OPTIONAL DT2-6 KIT IF DUCTING ON DISCHARGE SIDE.
DIAGRAM N
PLACE MAGNETIC DRAFT STOPS OVER XCHANGER FAN OPEN­ING(S) WHEN FAN IS NOT IN USE TO BLOCK AIR INFILTRATION IF DESIRED. PLACE ON SIDE OF CABINET IF NOT IN USE SO THEY ARE NOT LOST.
Page 8
WHAT IS NOT COVERED
Product installed contrary to our installation instructions Product that has been altered, neglected or misused Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing the defective part
XCHANGER PARTS AND ACCESSORIES
REPLACEMENT PARTS
XCHANGERTMFan Assembly 950-8350 XCHANGERTMHood Screen 950-8352 XCHANGERTMHood with Screen 950-8353 X
CHANGER
TM
Magnetic Draft Stops (2) 950-8354
OPTIONAL ACCESSORIES
6” Duct Take-Off Kit DT2-6 6” Spring Return Back-Draft Damper BD-6 6” White Plastic Exhaust / Supply Grille G-6 DH2P Dehumidistat Control DH2P Plug-In Speed Control SCP Wireless 120v Outlet SWR
7
TJERNLUND LIMITED 1 YEAR WARRANTY
Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WAR­RANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WAR­RANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclu­sion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. Send all inquiries regard­ing warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 • Email fanmail@tjfans.com.