Step 1
Mark the positions to drill the 4 holes on
the bottom plate of the unit.
Step 2
Drill holes to mount the mounting base.
Step 3
Install mounting base to the floor using
anchor screws.
Step 4
Install the unit onto the mounting base
using pop rivets.
Commissioning (Balancing)
The balancing port is positioned on
the side behind the decor strip. The Kfactor of the unit is stated on the Kfactor label mounted on one of the
side of the balancing port. The kfactor can also be found on our
website in the relevant k-factor guide.
See Figure 5
FIGURE 5
2.0
DVCP Duct Cover Parts
Installation Manual
DVCP Duct Cover Installation
DV5-9-13
2.1
Installation Manual
DVCP Duct Cover Installation
Step 1
Mount the duct cover bottom on the top of
the unit.
Duct Cover Bottom
DV5-9-13
Step 2
Mount the duct cover support assembly
on the top of the unit. Align the holes on
the flange of the duct cover bottom and
the duct cover support assembly and cut
the support according to the ceiling height
keeping 2” distance between the ceiling
and the top of the duct covert support
assembly. Align the duct cover top with
the three holes on the support assembly
and rivet the duct cover top with the duct
cover support assembly in 2 places.
DUCT COVER TOP
DUCT COVER
SUPPORTER
2.2
Installation Manual
DVCP Duct Cover Installation
DV5-9-13
Step 3
Install the duct onto the unit. Install the
second duct cover top to the duct
cover support assembly enclosing the
duct. Assemble both the duct cover top
together using pop rivets.
Step 4
Assemble all four duct cover support
assemblies to the duct cover bottom
using pop rivets.
2.3
Installation Manual
DVCP Duct Cover Installation
DV5-9-13
Step 5
Align the top edge of the duct cover
support assembly with the top face of the
extension and install the extension
assembly onto the duct cover support
assembly using screws. (Décor strip of the
unit should align with the décor strip of the
duct cover assembly)
Step 6
Place the duct cover on the top of the unit
and assemble it to the duct cover support
assembly using screws. Snap the décor strips
into the springs of the duct cover support
assemblies.
2.4
Installation Manual
DVVC Installation
DV5-9-13
Step 1
Drill the holes on the bottom plate of
the unit and the mounting base. Install
the mounting base into place using
screws.
Step 2
Install wall brackets to the wall using
screws and slide the bottom of the unit
into the angle wall brackets.
Step 3
Install wall bracket to the wall to hold the
top of the unit using screws.
Commissioning (Balancing)
The balancing port is positioned on the
side behind the decor strip. The K-factor of
the unit is stated on the K-factor label
mounted on one of the side of the
balancing port. The k-factor can also be
found on our website in the relevant kfactor guide. See Figure 5
FIGURE 4
3.0
DVVC Duct Cover Parts
Installation Manual
DVVC Installation
DV5-9-13
3.1
Installation Manual
DVVC Duct Cover Installation
DV5-9-13
Step 1
Cut the brackets according to the
ceiling height keeping 0-2” distance
between the ceiling and top of the
bracket.
Step 2
Using spacers align the brackets to the end of
the unit keeping 0.67” distance from the end
face of the unit. Screw the left and right
brackets to the wall.
3.2
Installation Manual
DVVC Duct Cover Installation
DV5-9-13
Step 3
Install the duct onto the unit. Align the
top edge of the brackets with the top
face of the extension and install the
extension assembly onto the brackets
using screws.
Step 4
Place the duct cover assembly on the top of
the unit and assemble it to the brackets using
screws. Snap the décor strips into the springs
of the extension and duct cover assemblies.
3.3
Installation Manual
DVHC Installation
DV5-9-13
Step 1
Drill the holes on the bottom plate of
the unit and the mounting base. Install
the mounting base into place using
screws.
Step 3
Install wall bracket to the wall to hold
the top of the unit using screws.
Step 2
Install wall bracket to the wall using
screws and slide the bottom of the unit
into the angle wall bracket.
Commissioning (Balancing)
The balancing port is positioned on the
side behind the decor strip. The Kfactor of the unit is stated on the Kfactor label mounted on one of the side
of the balancing port. The k-factor can
also be found on our website in the
relevant k-factor guide. See Figure 4
FIGURE 4
4.0
DVHC Duct Cover Parts
Installation Manual
DVHC Duct Cover Installation
DV5-9-13
4.1
Installation Manual
DVHC Duct Cover Installation
DV5-9-13
Step 1
Cut the brackets according to the ceiling
height keeping 0-2” distance between the
ceiling and top of the bracket.
Step 2
Using spacers align the brackets to the
end of the unit keeping 0.67” distance
from the end face of the unit. Screw the
left and right brackets to the wall.
4.2
Installation Manual
DVHC Duct Cover Installation
DV5-9-13
Step 3
Install the duct onto the unit. Align the
top edge of the brackets with the top
face of the extension and install the
extension assembly onto the brackets
using screws.
Step 4
Place the duct cover assembly on the top
of the unit and assemble it to the brackets
using screws. Snap the décor strips into
the springs of the extension and duct
cover assemblies.
4.3
Installation Manual
DVBC Installation
DV5-9-13
Step 1
Drill the holes on the bottom plate of
the unit and the mounting base. Install
the mounting base into place using
screws.
Step 3
Install wall bracket to the wall to hold the
top of the unit using screws.
Step 2
Install wall bracket to the wall using
screws and slide the bottom of the unit
into the angle wall bracket.
Commissioning (Balancing)
The balancing port is positioned on the
side behind the decor strip. The K-factor
of the unit is stated on the K-factor label
mounted on one of the side of the
balancing port. The k-factor can also be
found on our website in the relevant kfactor guide. See Figure 4
FIGURE 4
5.0
DVBC Duct Cover Parts
(For Size 12-36)
Installation Manual
DVBC Duct Cover Installation
DV5-9-13
5.1
Installation Manual
DVBC Duct Cover Installation
DV5-9-13
Step 1
Cut the brackets according to the ceiling
height keeping 0-2” distance between the
ceiling and top of the bracket.
Step 2
Using spacers align the brackets to the
end of the unit keeping 0.67” distance
from the end face of the unit. Screw the
left and right brackets to the wall.
Step 3
Install the duct onto the unit. Align the top
edge of the brackets with the top face of
the extension and install the extension
assembly onto the brackets using screws.
5.2
Installation Manual
DVBC Duct Cover Installation
DV5-9-13
Step 4
Mount the mounting fixture assembly
on the top of the unit.
Step 5
Slide the duct cover in-between the
mounting strip and the aluminum strip and
assemble it to the brackets using screws.
Snap the décor strips into the springs of
the extension and duct cover assemblies.
5.3
Installation Manual
DVRI Installation
Step 1
Drill the holes and install the mounting
base into place using screws.
DV5-9-13
Step 2
In Wall Mounting - Install the four Angle
brackets on the top of the unit using
screws. (You may need to cut the angle
strips to match the overall dimensions of
the unit.) Install the unit into the wooden
frame and screw to the sides. Install angle
strips from the sides to the front of the unit
using screws.
6.0
Installation Manual
DVRI Installation
DV5-9-13
Step 3
Floor Mounting - Using Angle Strips
screw the unit to the wall from the top
and the sides. (You may need to cut
the angle strips to match the overall
dimensions of the unit.)
Step 4
Mounting against the wall - Using Angle
Strips screw the unit against the wall from
the top and the bottom. (You may need to
cut the angle strips to match the overall
dimensions of the unit.)
6.1
Installation Manual
DVRI Installation
Commissioning (Balancing)
Uninstall the front cover for maintenance. For Size < 10 the
balancing port is positioned on the side of the unit behind
the white plug and For Size > 12 the balancing port is
positioned in the center behind the decor strip. The K-factor
of the unit is stated on K-factor label mounted on long
bracket behind the front cover for Size < 10 and on one of
the side of the balancing port for Size > 12. The k-factor
can also be found on our website in the relevant k-factor
guide. See Figure 4
DV5-9-13
FIGURE 4
6.2
Installation Manual
DVIR Installation
DV5-9-13
Step 1
Screw the Plenum-Inlet Assembly into
place through the sides. (Note: PlenumInlet Assembly is mounted before the wall
board is fixed)
Step 2
Install the Mounting frame-Distributor
assembly to the wall board using screws.
Step 3
Install front cover onto the Mounting
frame-Distributor assembly.
Commissioning (Balancing)
Uninstall the front cover for
commissioning. The balancing port is
positioned on the lower edge of the unit.
The K-factor of the unit is stated on Kfactor label placed on one of the side of
the Plenum box. The k-factor can also be
found on our website in the relevant kfactor guide. See Figure 4
FIGURE 2
FIGURE 4
7.0
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.