Important Safety Information • Read all safety information before
operating the equipment. Save these instructions.
This symbol indicates a hazardous situation,
which, if not not avoided could result in death or
serious injury.
To reduce the risks of fire or explosion, electrical
shock and the injury to persons, read and understand all instructions included in this manual. Be
familiar with the controls and proper usage of the
equipment.
HAZARD: INJECTION INJURY
A high pressure paint stream produced by this
equipment can pierce the skin and underlying
tissues, leading to serious injury and possible
amputation. See a physician immediately
DO NOT TREAT AN INJECTION INJURY AS A SIMPLE CUT!
Injection can lead to amputation. See a physician
immediately.
The maximum operating range of the sprayer is 3000 PSI / 20.6
MPa fluid pressure.
PREVENTION:
• NEVER aim the gun at any part of the body.
• Do not aim the gun at, or spray any person or animal.
• NEVER allow any part of the body to touch the fluid stream.
DO NOT allow body to touch a leak in the fluid hose.
• NEVER put your hand in front of the gun. Gloves will not
provide protection against an injection injury.
• ALWAYS lock the gun trigger, shut the pump off, and
release all pressure before servicing, cleaning the tip or
guard, changing tip, or leaving unattended. Pressure will
not be released by turning off the motor. The
PRIME/SPRAY valve or pressure bleed valve must be
turned to their appropriate positions to relieve system
pressure. Refer to the PRESSURE RELIEF
PROCEDURE described in this manual.
• ALWAYS keep the tip guard in place while spraying. The
tip guard provides some protection but is mainly a warning
device.
• ALWAYS remove the spray tip before flushing or cleaning
the system.
• Paint hose can develop leaks from wear, kinking and
abuse. A leak can inject material into the skin. Inspect
the hose before each use. Do not use hose to lift or pull
equipment.
• NEVER use a spray gun without a working trigger lock
and trigger guard in place.
• All accessories must be rated at or above 3000 PSI / 20.6
MPa. This includes spray tips, guns, extensions, and hose.
• Do not leave the unit energized or under pressure while
unattended. When the unit is not in use, turn off the unit
and relieve the pressure in accordance with the
PRESSURE RELIEF PROCEDURE described in this
manual.
• Verify that all connections are secure before operating the
unit. Unsecured parts may eject at great force or leak a
high pressure fluid stream causing severe injury.
• Always engage the trigger lock when not spraying. Verify
the trigger lock is functioning properly.
NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury. It is
important to treat the injury as soon as possible. DO
NOT delay treatment to research toxicity. Toxicity is a
concern with some coatings injected directly into the
blood stream. Consultation with a plastic surgeon or
reconstructive hand surgeon may be advisable.
.
HAZARD: HAZARDOUS VAPORS
Paints, solvents, insecticides, and other materials can
be harmful if inhaled or come in contact with the body
Vapors can cause severe nausea, fainting, or
poisoning.
PREVENTION:
• Use a respirator or mask if vapors can be
inhaled. Read all instructions supplied with the
mask to be sure it will provide the necessary
protection.
ear protective eyewear.
• W
• Wear protective clothing as required by coating
manufacturer.
HAZARD: EXPLOSION OR FIRE
Solvent and paint fumes can explode or ignite.
Property damage and/or severe injury can occur
PREVENTION:
• Provide extensive exhaust and fresh air introduction to
keep the air within the spray area free from accumulation
of flammable vapors. Solvent and paint fumes can
explode or ignite.
• Do not spray in a confined area.
• Avoid all ignition sources such as static electric
sparks, open flames, pilot lights, electrical
appliances, and hot objects. Connecting or disconnecting
power cords or working light switches can make sparks.
Paint or solvent flowing through the equipment is able to
result in static electricity.
• Do not smoke in spray area.
• Fire extinguisher must be present and in good working
order.
• Place pump at least 25 feet (7.62 meters) from the spray
object in a well ventilated area (add more hose if
necessary). Flammable vapors are often heavier than air.
Floor area must be extremely well ventilated. The pump
contains arcing parts that emit sparks and can ignite
vapors.
• The equipment and objects in and around the spray area
must be properly grounded to prevent static sparks.
• Keep area clean and free of paint or solvent containers,
rags and other flammable materials.
• Use only conductive or grounded high pressure fluid hose.
Gun must be grounded through hose connections.
• For electric units — power cord must be connected to a
grounded circuit.
• Always flush unit into a separate metal container, at low
pump pressure, with spray tip removed. Hold gun firmly
against side of container to ground container and prevent
static sparks.
• Follow the material and solvent manufacturer's warnings
and instructions. Know the contents of the paints and
solvents being sprayed. Read all Material Safety Data
Sheets (MSDS) and container labels provided with the
paints and solvents. Follow the paint and solvent
manufacturer’s safety instructions.
• Use extreme caution when using materials with a
flashpoint below 70ºF (21ºC). Flashpoint is the
temperature that a fluid can produce enough vapors to
ignite.
• Plastic can cause static sparks. Never hang plastic to
enclose a spray area. Do not use plastic drop cloths
when spraying flammable materials.
• Use lowest possible pressure to flush equipment.
Important Safety Information • Read all safety information before
operating the equipment. Save these instructions.
HAZARD: EXPLOSION HAZARD DUE TO
Will cause property damage or severe injury.
PREVENTION:
• Do not use materials containing bleach or chlorine.
• Do not use halogenated hydrocarbon solvents such as
• Contact your coating supplier about the compatibility of
HAZARD: GENERAL
Can cause severe injury or property damage.
•
• Follow all appropriate local, state, and national codes
• The United States Government Safety Standards have
• Use only manufacturer authorized parts. User assumes
• All hoses, fittings, and filter parts must be secured before
• Before each use, check all hoses for cuts, leaks, abrasion
• Do not kink or over-bend the hose. Airless hose can
• Do not expose the hose to temperatures or pressures in
• Do not spray outdoors on windy days.
• Wear clothing to keep paint off skin and hair.
• Do not operate or spray near children. Keep children
• Do not overreach or stand on an unstable support. Keep
• Use lowest possible pressure to flush equipment.
• Stay alert and watch what you are doing.
• Do not operate the unit when fatigued or under the
• For electric units — Always unplug cord from outlet before
• Do not use the hose as a strength member to pull or lift
• Do not lift by cart handle when loading or unloading.
INCOMPATIBLE MATERIALS
bleach, mildewcide, methylene chloride and 1,1,1 trichloroethane. They are not compatible with aluminum.
material with aluminum.
Read all instructions and safety precautions before
operating equipment.
governing ventilation, fire prevention, and operation.
been adopted under the Occupational Safety and Health
Act (OSHA). These standards, particularly part 1910 of
the General Standards and part 1926 of the Construction
Standards should be consulted.
all risks and liabilities when using parts that do not meet
the minimum specifications and safety requirements of the
pump manufacturer.
operating spray pump. Unsecured parts can eject at great
force or leak a high pressure fluid stream causing severe
injury.
or bulging of cover. Check for damage or movement of
couplings. Immediately replace the hose if any of these
conditions exist. Never repair a paint hose. Replace it
with another grounded high-pressure hose.
develop leaks from wear, kinking and abuse. A leak can
inject material into the skin.
excess of those specified by manufacturer.
away from the equipment at all times.
effective footing and balance at all times.
influence of drugs or alcohol.
working on equipment.
the equipment.
Grounding Instructions
This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product
is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
Improper installation of the grounding plug
can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not
connect the green grounding wire to either flat blade terminal.
The wire with insulation having a green outer surface with or
without yellow stripes is the grounding wire and must be
connected to the grounding pin.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if you
are in doubt as to whether the product is properly grounded.
Do not modify the plug provided. If the plug will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
IMPORTANT: Use only a 3-wire extension cord that has a
3-blade grounding plug and a 3-slot receptacle that will
accept the plug on the product. Make sure your extension
cord is in good condition. When using an extension cord,
be sure to use one heavy enough to carry the current your
product will draw
in line voltage resulting in loss of power and overheating.
A 12 gauge cord is recommended. If an extension cord is
to be used outdoors, it must be marked with the suffix WA after the cord type designation. For example, a
designation of SJTW-A would indicate that the cord would
be appropriate for outdoor use.
IMPORTANT: When the sprayer is used with a generator
or uncontrolled line voltage, the use of Titan’s “Line Surge
Protector” (P/N 800-935) is recommended.
. An undersized cord will cause a drop
Specifications
Gallons per minute (GPM)...............0.40 (1.5 LPM)
Maximum tip sizes ...........................0.019”
Maximum pressure ..........................3000 PSI (20.6 MPa)
Power...............................................3/4 HP DC motor
Weight..............................................34 lbs. (15.4 kg)
Maximum hose length......................300’ (91.4 m )
This airless sprayer is a precision power tool used for spraying
many types of materials. Read and follow this instruction
manual carefully for proper operating instructions,
maintenance, and safety information.
Operation
This equipment produces a fluid stream at
extremely high pressure. Read and understand
the warnings in the Safety Precautions section at
the front of this manual before operating this
equipment.
Setup
Perform the following procedure before plugging in the power
cord of an electric sprayer.
1. Ensure that the siphon tube and the return hose are
attached and secure.
2. Using a wrench, attach a minimum of 50’ x 1/4” nylon
airless spray hose to the outlet fitting on the sprayer.
Tighten securely.
3. Attach an airless spray gun to the spray hose. Using two
wrenches (one on the gun and one on the hose), tighten
securely.
NOTE: Do not attach the tip to the spray gun yet.
4. Make sure the pressure control knob is turned fully
5.
6. Fill the oil cup with one tablespoon of piston seal lubricant
IMPORTANT: Never operate unit for more than ten
seconds without fluid. Operating this unit without fluid
will cause unnecessary wear to the packings.
7. Make sure the electrical service is correct for the sprayer.
8.
IMPORTANT: Always use a minimum 12 gauge, three-wire
extension cord with a grounded plug. Never remove the
third prong or use an adapter
Preparing a New Sprayer
If this sprayer is new, it is shipped with test fluid in the fluid
section to prevent corrosion during shipment and storage.
This fluid must be thoroughly cleaned out of the system with
mineral spirits before you begin spraying.
IMPORTANT:
gun in the locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits
2.
3. Set the pressure to minimum by turning the pressure
4. Move the PRIME/SPRAY valve down to
5. Turn on the sprayer by moving the
6. Allow the sprayer to run for 15–30 seconds
7. Turn off the sprayer by moving the ON/OFF switch to the
Make sure all airless hoses and spray guns are
electrically grounded and rated at or above the
maximum operating pressure range of the airless
sprayer
counterclockwise to its minimum setting.
Make sure the ON/OFF switch is in its OFF position.
(Piston Lube).
Plug the power cord into a properly grounded outlet at
least 25’ from the spray area.
that has a flash point of 140ºF (60ºC) or above.
Place the return hose into a metal waste container.
control knob fully counterclockwise.
the PRIME position.
ON/OFF switch to the ON position.
to flush the test fluid out through the return hose and into
the waste container.
OFF position.
.
.
Always keep the trigger lock on the spray
Preparing to Paint
Trigger lock in
locked position.
Trigger lock in
locked position.
Before painting, it is important to make sure that the fluid in the
system is compatible with the paint that is going to be used.
NOTE: Incompatible fluids and paint may cause the
IMPORTANT: Always keep the trigger lock on the spray
gun in the locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure
4. Move the PRIME/SPRAY valve down to the
NOTE: Hold the return hose in the waste
5. Turn on the sprayer by moving the ON/OFF switch to the
6. Allow the sprayer to run for 15–30 seconds to flush the old
7. Turn off the sprayer by moving the ON/OFF switch to the
NOTE: Make sure that the spray gun does not have a
8. Move the PRIME/SPRAY valve up to the
9. Turn on the sprayer. Make sure the
10. Unlock the gun by turning the gun trigger lock to the
11. Trigger the gun into the metal waste container until the old
12.
13. Set down the gun and increase the
14. Check the entire system for leaks. If
15. Follow the “Pressure Relief Procedure” in this manual
valves to become stuck closed, which would
require disassembly and cleaning of the
sprayer’s fluid section.
solvent for the material being sprayed (refer to
recommendations of the material manufacturer).
example of the appropriate solvent is water for latex paint.
control knob fully counterclockwise.
PRIME position.
container when moving the
PRIME/SPRAY valve to PRIME in
case the sprayer is pressurized.
ON position.
solvent out through the return hose and into the metal
waste container.
OFF position.
tip or tip guard installed.
SPRAY position.
pressure is still set to minimum with the
pressure control knob turned fully counterclockwise.
unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure
to do so may lead to a static
electric discharge, which may
cause a fire.
solvent is gone and fresh solvent is coming out of the gun.
Lock the gun by turning the gun trigger
lock to the locked position.
pressure by turning the pressure control
knob slowly clockwise.
leaks occur, follow the “Pressure Relief
Procedure” in this manual before tightening any fittings or
hoses.
before changing from solvent to paint.
Be sure to follow the pressure relief procedure
when shutting down the sprayer for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
An
Painting
1. Place the siphon tube into a container of paint.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure
control knob fully counterclockwise.
4. Move the PRIME/SPRAY valve down to the
PRIME position.
5. Turn on the sprayer by moving the ON/OFF
switch to the ON position.
6. Allow the sprayer to run until paint is
coming through the return hose into the metal waste
container.
7. Turn off the sprayer by moving the ON/OFF switch to the
OFF position.
8. Remove the return hose from the waste container and
place it in its operating position above the container of
paint.
9. Move the PRIME/SPRAY valve up to the
SPRAY position.
10. Turn on the sprayer.
11. Unlock the gun by turning the gun trigger
lock to the unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure
to do so may lead to a static
electric discharge, which may
cause a fire.
12. Trigger the gun into the metal waste container until all air
and solvent is flushed from the spray hose and paint is
flowing freely
13. Lock the gun by turning the gun trigger
lock to the locked position.
14. Turn off the sprayer.
15. Attach tip guard and tip to the gun as
instructed by the tip guard or tip manuals.
POSSIBLE INJECTION HAZARD.
Do not spray without the tip guard
in place. Never trigger the gun unless the tip is in
either the spray or the unclog position. Always
engage the gun trigger lock before removing,
replacing or cleaning tip.
16. Turn on the sprayer.
Increase the pressure by turning the pressure control
17.
knob slowly clockwise and test the spray pattern on a
piece of cardboard. Adjust the pressure control knob until
the spray from the gun is completely atomized. Try to
keep the pressure control knob at the lowest setting that
maintains good atomization.
NOTE: Turning the pressure up higher then needed to
atomize the paint will cause premature tip wear
and additional overspray.
Be sure to follow the pressure relief procedure
when shutting the unit down for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
1. Lock the gun by turning the gun trigger
lock to the locked position.
2.
Turn off the sprayer by moving the
ON/OFF switch to the OFF position.
3. Set the pressure to minimum by turning
the pressure control knob fully
counterclockwise.
4. Unlock the gun by turning the gun trigger
lock to the unlocked position.
5. Hold the metal part of the gun firmly to
the side of a metal container to ground
the gun and avoid a build up of static
electricity.
6. Trigger the gun to remove any
pressure that may still be in the hose.
7. Lock the gun by turning the gun trigger lock to the locked
position.
8. Move the PRIME/SPRAY valve down to the
PRIME position.
Spraying
Avoid arcing or holding the gun at an angle. This will result in
an uneven finish.
Proper lapping (overlap of spray pattern) is essential to an
even finish. Lap each stroke. If you are spraying horizontally,
aim at the bottom edge of the preceding stroke, so as to lap
the previous pattern by 50%.
POSSIBLE INJECTION HAZARD. Do not spray
without the tip guard in place. Never trigger the
gun unless the tip is in either the spray or the
unclog position. Always engage the gun trigger
lock before removing, replacing, or cleaning tip.
Spraying Technique
The following techniques, if followed, will assure professional
painting results.
Hold the gun perpendicular to the surface and always at equal
distance from the surface. Depending on the type of material,
surface, or desired spray pattern, the gun should be held at a
distance of 12 to 14 inches (30 to 35 cm).
Move the gun either across or up and down the surface at a
steady rate. Moving the gun at a consistent speed conserves
material and provides even coverage. The correct spraying
speed allows a full, wet coat of paint to be applied without runs
or sags.
Holding the gun closer to the surface deposits more paint on
the surface and produces a narrower spray pattern. Holding
the gun farther from the surface produces a thinner coat and
wider spray pattern. If runs, sags, or excessive paint occur,
change to a spray tip with a smaller orifice. If there is an
insufficient amount of paint on the surface or you desire to
spray faster, a larger orifice tip should be selected.
Maintain uniform spray stroke action. Spray alternately from
left to right and right to left. Begin movement of the gun before
the trigger is pulled.
For corners and edges, split the
center of the spray pattern on the
corner or edge and spray
vertically so that both adjoining
sections receive approximately
even amounts of paint.
When spraying with a shield, hold it firmly against the surface.
Angle the spray gun slightly away from the shield and toward
the surface. This will prevent paint from being forced
underneath.
Shrubs next to houses should be tied back and covered with a
canvas cloth. The cloth should be removed as soon as possible.
gun extensions are extremely helpful in these situations.
Nearby objects such as automobiles, outdoor furniture, etc.
should be moved or covered whenever in the vicinity of a
spray job. Be careful of any other surrounding objects that
could be damaged by overspray.
1. Be sure that the paint hose is free of kinks and clear of
objects with sharp cutting edges.
2. Turn the pressure control knob counterclockwise to its to
its lowest setting.
3. Turn the PRIME/SPRAY valve up to its SPRAY position.
4. Turn the pressure control knob clockwise to its highest
setting. The paint hose should stiffen as paint begins to
flow through it.
5. Unlock the gun trigger lock.
6. Trigger the spray gun to bleed air out of the hose.
7. When paint reaches the spray tip, spray a test area to
check the spray pattern.
8. Use the lowest pressure setting
necessary to get a good spray
pattern. If the pressure is set too
high, the spray pattern will be too
light. If the pressure is set too
low, tailing will appear or the
paint will spatter out in gobs
rather than in a fine spray.
Cleanup
9. Turn off the sprayer by moving the ON/OFF
switch to the OFF position.
10. Move the PRIME/SPRAY valve up to its
SPRAY position.
11. Turn on the sprayer.
Ground the gun by holding it against
the edge of the metal container while
flushing. Failure to do so may lead
to a static electric discharge, which
may cause a fire.
12. Trigger the gun into the metal waste
container until the paint is flushed out of the hose and
solvent is coming out of the gun.
13.
Continue to trigger the spray gun into the waste container
until the solvent coming out of the gun is clean.
NOTE: For long-term or cold weather storage, pump
mineral spirits through the entire system.
For short-term storage when using latex paint,
pump water mixed with Titan Liquid Shield Plus
through the entire system (see the Accessories
section of this manual for part number).
Special cleanup instructions for use with
flammable solvents:
• Always flush spray gun preferably outside and at least one
hose length from spray pump.
•
If collecting flushed solvents in a one gallon metal
container, place it into an empty five gallon container, then
flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
IMPORTANT: The sprayer, hose, and gun should be
cleaned thoroughly after daily use. Failure to do so
permits material to build up, seriously affecting the
performance of the unit.
Always spray at minimum pressure with the gun
nozzle tip removed when using mineral spirits or
any other solvent to clean the sprayer, hose, or
gun. Static electricity buildup may result in a fire
or explosion in the presence of flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
2.
Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate
solvent (refer to recommendations of the material
manufacturer). An example of the appropriate solvent is
water for latex paint.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve down to its
PRIME position.
NOTE: Hold the return hose in the waste
6. Set the pressure to minimum by turning the pressure
7. Turn on the sprayer by moving the ON/OFF switch to the
8. Allow the solvent to circulate through the sprayer and
container when moving the
PRIME/SPRAY valve to PRIME in
case the sprayer is pressurized.
control knob fully counterclockwise.
ON position.
flush the paint out of the return hose into the metal waste
container.
14. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
15. Unplug the sprayer and store in a clean, dry area.
IMPORTANT: Do not store the unit under pressure.
Cleaning the Spray Tip
1. Flush the gun with solvent immediately after the work is
completed.
2. Oil the retractor pins to prevent them from seizing up.
Should the spray tip become clogged, reverse
the spray tip with the lever and pull the trigger.
Once the obstruction comes out of the spray
tip, release the trigger, reverse the spray tip
back to the spray pattern setting, and resume
spraying.
Do not attempt to clean the tip with your finger.
Do not use a needle or other sharp pointed
instrument to clean the tip. The hard tungsten
carbide is brittle and can be chipped.
The following tools are needed when repairing this sprayer:
1. Before repairing any part of the sprayer, read the
IMPORTANT: Never pull on a wire to disconnect it. Pulling
on a wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be
3. Make certain that the service area is well ventilated in
4. If you have any further questions concerning your TITAN
Replacing the Motor
1. Unplug the sprayer.
2. Loosen and remove the four motor cover screws.
3. Disconnect the black and red wires coming from the pump
4. Remove the capacitors from their mounting clip.
5. Loosen and remove the four motor mounting screws.
6. Pull the motor out of the pump housing.
NOTE: If the motor will not dislodge from the pump
7. With the motor removed, inspect the gears in the pump
8. Install the new motor into the pump housing.
NOTE: Rotate the motor fan manually until the
9. Secure the motor with the four motor mounting screws.
10. Using the double-sided tape and the tie wrap that came
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce
the risk of an injection injury, injury from moving
parts or electric shock. Always unplug the
sprayer before servicing!
sure that the problem is corrected. If the sprayer does not
operate properly
, review the repair procedure to determine if
everything was done correctly. Refer to the Troubleshooting
Charts to help identify other possible problems.
case solvents are used during cleaning. Always wear
protective eyewear while servicing. Additional protective
equipment may be required depending on the type of
cleaning solvent. Always contact the supplier of solvents
for recommendations.
Airless Sprayer, call TITAN:
Customer Service (U.S.) .......................1-800-526-5362