TGVL01Single Gang 2-Way Switch [SP] 10AX (Fluorescent rated)
TGVL02Twin Gang 2-Way Switch [SP] 10AX (Fluorescent rated)
TGVL03Single Gang Bell Push Switch [SP] 10AX (Fluorescent rated)
TGVL05Single Gang Switch [DP] 20AX (Fluorescent rated)
TGV101N Single Gang Socket Switched 13A
TGV201N Twin Gang Socket Switched 13A
TGV104NP Single Gang RCD Fused Spur 13A
TGV204NP Twin Gang RCD Socket Switched 13A
(Passive/Latching)
1
TGV205NP Twin Gang RCD Socket Switched 13A
(Active/Non-Latching)
TGV103N Single Gang Switched Fused Spur 13A –
with Neon
1. General Information
These instructions should be read carefully and retained for further
reference and maintenance.
All Weathersafe Vision products need to be fitted with waterproof
cable and conduit entries to maintain their IP rating once installed.
2. Safety
• Before installation or maintenance, ensure the mains supply to
the switch, socket, spur or bell push unit is switched off and the
circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used
for the installation of this IP66 rated switch, socket, spur or bell
push unit and install in accordance with the current IEE wiring
and Building Regulations.
• Check that the total load on the circuit including when this
switch, socket, spur or bell push unit is fitted does not exceed the
rating of the circuit cable, fuse or circuit breaker.
• Electricity can be dangerous; the use of an RCD should not be
regarded as a substitute for basic electrical safety precautions.
• Always test the RCD before use. If the test procedure is not
completed satisfactory or an appliance continues to trip the RCD
seek professional advice and switch off the appliance.
• To clean, use a clean dry cloth only. Do NOT use any liquid cleaners.
• During use warming of the enclosure is normal.
Wiring tests – Important (TGV104NP, TGV204NP & TGV205NP)
• Remove this product from the circuit if carrying out tests (as
2
described in the IEE Wiring Regulations) for earth loop impedance,
prospective short circuit current and insulation resistance.
• Use the enclosed warning label to ensure this is carried out.
3. Technical Specifications
General
• Voltage: 230V AC 50Hz
• IP Rating: IP66
• All products in the range comply with the low voltage directive
2014/35/EU and where relevant the EMC directive 2014/30/EU
and ROHS directive 2011/65/EU & 2015/863.
• CE Compliant
Switches (TGVL01, TGVL02, TGVL03, TGVL05)
• Backlit neon (illuminates switch for dark areas)
• Rocker Switch Rating: 13Amp (3kW) 10AX
• Operating temperature range: -5° to 55°C
• Complies with: BS EN 60669
Sockets (TGV101N & TGV201N)
• Individual power ‘ON’ Neon Indicators
• Lockable cover facility
• Operating temperature range: -5° to 55°C
• Complies with: BS1363
RCD’S (TGV104NP, TGV204NP, TGV205NP)
• Lockable cover facility
• Rated trip current: 30mA
• RCD Type: Double pole, suitable for
3
2 and 3 wire applications
• Breaking capacity: 250A (Earth leakage)
• Through fault withstand: 1500A
• Trip Speed: Less than 40msec at 150mA
residual current
1. IMPORTANT Switch off the electricity at the fuse box by removing
the relevant fuse or switching off the circuit breaker before
proceeding with the installation.
2. Remove the black coloured rocker switch from the faceplate
pivot support joints using a suitable flat ended screwdriver.
Using a Philips screwdriver, separate the faceplate from the back
box by removing the four tapped screws located in each corner.
See figure 1.
Backlit neon
45
Face plate pivot
support joints
3. Using the back plate as a template mark the position for the
holes. Note the back plate must be mounted in the correct
orientation, following the ‘TOP’ marking inside the back plate.
If the mounting position desired is uneven use a sheet of
marine ply as a base plate and fit the back box.
4. Drill the wall using a 4mm Ø drill bit making sure not to infringe
or compromise any gas, water pipes or cables. Insert the rawl
plugs into the holes.
5. The drain feature must be drilled out using a 5mm drill if the top
or side entry conduit is used. Opening this drain hole will reduce
the IP rating of the product. Remember – open out the lower
drain feature only.
Tapped screws
Figure 1
This applies to the
following models:
TGVL01, TGVL02,
TGVL03 & TGVL05