Timeguard STFL30PIRB, STFL50PIRB, STFL20PIRB, STFL10PIRB Installation Instructions

LED PIR Floodlight
Models: STFL10PIRB STFL20PIRB STFL30PIRB STFL50PIRB
1
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
It is recommended that a qualified electrician is consulted or used for the installation of this luminaire and install in accordance with the current IEE wiring and Building Regulations.
Check that the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
230V AC, 50Hz
These luminaires are of class I construction and must be earthed
• Energy Efficiency: Class A+
Colour Temperature: 4000K
IP65 Rated suitable for restricted external applications
Detection Angle: 110°
Detection Range: Up to 10 metres
Time On Adjustment: 3 seconds to 18 minutes
Dusk Level Adjustment: Day and Night or Night only operation
CE Approved
STFL10PIRB
10W LED Non replaceable lamp
Energy Usage: 10kWh/1000h
Lumen Output: 900lm
STFL20PIRB
20W LED Non replaceable lamp
Energy Usage: 20kWh/1000h
Lumen Output: 1800lm
STFL30PIRB
30W LED Non replaceable lamp
Energy Usage: 30kWh/1000h
Lumen Output: 2700lm
STFL50PIRB
50W LED Non replaceable lamp
Energy Usage: 50kWh/1000h
Lumen Output: 4500lm
4. Installation Advice
As the detector responds to changes in temperature, avoid the following situations:
Pointing the detector towards objects with highly reflective surfaces, such as pools of water or white-painted walls.
Mounting the detector near heat sources, such as heating vents, air conditioning units, lights etc.
Pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
Recommended installation height is 2.5m above ground, the maximum detection range about 10 m and at the angle of about 110°.
2m
2
2.5m
2m
up to 10m
110°
up to 10m
up to 6m
110°
Walk across
2m
110°
Walk towards
3
5. Installation Procedure
5.1 Mark the position of the mounting holes on the wall using the U bracket supplied as a template.
5.2 Drill the holes for the wall plugs ensuring not to infringe with any gas/water pipes or electrical cables that may be hidden below the surface.
5.3 Fix the U bracket to the wall using the correct screws for the wall plugs installed.
6. Connection Diagram
Connect the 3 core mains supply cable from the unit as follows:-LIVE (Brown or
Red) L
NEUTRAL (Blue or Black) N
EARTH (Green/Yellow)
E
4
brown
yellow & green
connect to main power
blue
brown blue yellow & green
7. Operation
Turn the power on to the isolating switch and test for correct operation.
L N E
8. Walk Test and Adjustment
The purpose of the Walk is used to test and adjust the detection coverage of the floodlight under auto mode.
Test Procedure
Adjust the Time knob to (fully anti-clockwise), and Lux knob is set to the ‘Sun’ setting.
Switch the power On.
Walk across the detection area, once to detector is triggered the lamp
will turn ON for 2 seconds.
Note walking direction when performing test.
5
3 sec 18 min
3
18
6
The detector head can be turned 90° left or right by hand, and can be tilted 70° downward.
Tilt upward 40°
Tilt downward 70°
Tilt upward 70°
Tilt downward 70°
Pan left 90°
Pan right 90°
7
Knob Settings
The floodlight has two adjustment knobs: Time and Lux at the bottom of the detector head.
Adjust the knobs carefully with flat blade screwdriver.
TIME knob setting
You can set the time knob from minutes, the floodlight will switch the lamp ON, for the time duration set after each detected movement.
Adjust the knob as desired.
3 seconds to about 18
LUX knob setting
When setting the Lux knob at ‘MOON’, the floodlight will only operate in the dark.
When setting the Lux knob at ‘SUN’, the floodlight will operate in any light level.
3 sec 18 min
3
18
9. Manual Override Mode
The light can be switched on for longer time periods by use of the Manual Override Mode. This can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker once (OFF/ON) within 2 seconds.
The unit will now illuminate continuously for 6 hours, then switched back into Auto Mode.
To switch the unit back into Auto Mode, switch the internal wall switch/circuit breaker once (OFF/ON) within 2 seconds. The unit will operate as set up after the walk test procedure.
8
within 2s
Activation
AutomodeDeactivation
6hr
or
within 2s
10. Troubleshooting Guide
9
Lamp stays ON all the time at night.
PIR keeps activating for no reason/ at random.
PIR sensor will not operate at all.
The PIR sensor will not operate at night.
The unit may be suffering from false activation. Cover the sensor lens completely with a thick cloth. This will prevent the sensor from ‘seeing’ anything. If the unit now switches off after the set time duration and does not re-activate, this indicates that the problem was caused by false activation.
You may not be allowing the unit time to complete its warm-up period. Stand well out of the detection range and wait (the warm-up period should never exceed 5 minutes).
Occasionally, winds may activate the sensor. Sometimes passages between buildings etc. can cause a ‘wind tunnel’ effect.
Ensure the unit is not positioned so as to allow detection of cars/people using public thoroughfares adjacent to your property.
Check that the power is switched ON at the circuit breaker/internal wall switch.
Turn OFF the power to the unit and check the wiring connections as per the diagram. Ensure no connections are loose.
The level of ambient light in the area may be too bright to allow operation at the current DUSK setting. During the hours of darkness, adjust the DUSK control slowly clockwise until the lamp illuminates. Refer to the previous section for more details.
Unit activates during the daytime.
The level of ambient light in the area may be too dark for the current DUSK setting. During daylight, adjust the DUSK control slightly anti-clockwise. When the lamp turns off, enter the detection area. If the PIR still activates, the setting is still too high. Repeat the above procedure until the PIR does not activate when you enter the detection area. Refer to the previous section for more details.
PIR coverage is poor/sporadic.
Detection range varies from day to day.
The floodlight will only activate
01
for a maximum of 15 seconds when in normal operating mode.
Unit may be poorly located. See previous section –
‘Selecting The Location’ and re-locate the unit.
PIR sensors are influences by climatic conditions. The colder the ambient temperature, the more effective the sensor will be.
The floodlight could be affected by its own light output. Tilt the PIR sensor further downwards and away from the floodlight. Once the floodlight has settled into the new time settings, re-angle the PIR sensor back to your desired position.
11
2 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material or manufacture within 2 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For year 2 or any difficulty in the first year, telephone the helpline on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent.
TG/IQ - V1