Timeguard SLB2300, SLW2300 Installation Instructions

2300W PIR Light Controller
Model: SLB2300 – Black
Model: SLW2300 – White
I n s t allat ion & O perating Instructions
1
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
• Before installation or maintenance, ensure the mains supply to the PIR sensor is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this PIR sensor and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this PIR sensor is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This PIR is of Class l construction and should be earthed
• Motion Detection Range: Up to 12m at 2.5m mounting height
• Detection Angle: 180°
• Maximum Switching Load: 250W LED, 1000W Halogen, Compact Fluorescent 400W Fluorescent tube w/o PF correction 500W
• Not suitable for use with Discharge Lighting
• Time ON Adjustment: 5 seconds to 18 minutes
• Dusk Level Adjustment: Day & Night or Night time only operation
• Operating Temperature: -20°C to +40°C
• IP55 Rated suitable for restricted external applications
• CE Compliant
2
4. Introduction
The SLB/W2300 utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the attached lighting load will illuminate for a user-determined period of time. An integral daylight sensor ensures all day or night-only operation.