2300W PIR Light Controller
Model: SLB2300 – Black
Model: SLW2300 – White
1
1. General Information
2. Safety
• Before installation or maintenance, ensure the mains supply to the PIR sensor is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this PIR sensor and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this PIR sensor is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This PIR is of Class l construction and should be earthed
• Motion Detection Range: Up to 12m at 2.5m mounting height
• Detection Angle: 180°
• Maximum Switching Load: 2300W Halogen Lighting 500W Fluorescent Lighting 250W LED Lighting (PF>=0.9)
• Not suitable for use with Discharge Lighting
• Time ON Adjustment: 5 seconds to 15 minutes
• Dusk Level Adjustment: Day & Night or Night time only operation
• Operating Temperature: -20°C to +40°C
• IP55 Rated suitable for restricted external applications
• CE Compliant
2
4. Introduction
The SLB/W2300 utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the attached lighting load will illuminate for a user-determined period of time. An integral daylight sensor ensures all day or night-only operation.