Specifications
Supply voltage 220 –240V 50Hz
Power consumption 6VA Lamps off
Lighting load Incandescent /tungsten halogen
3000W Maximum (1500W each zone)
SUITABLE FOR FLUORESCENT LIGHTING AND LOW ENERGY BULBS
UP TO 500W MAXIMUM IN EACH ZONE
Light-on-time Adjustable from 5 seconds to 5 minutes.
Timing interval starts from last detection.
Light level Adjustable from 5 lux to 100 lux using zone
1 detector.
Detection coverage 2 independent zones of detection with up to 4 Wall
Sensor Detectors (SL099) each zone. Detector range
up to 15 metres at an ambient temperature of 20°C
and 180° coverage in the horizontal plane.
Protection rating Wall Sensor Detector (SLO99) – IP54
Operating rating -20°C to +50°C
Conforms to directives: 73/23/EEC and 89/336/EEC
5 Year Guarantee
We shall repair or at our option replace this product if it becomes defective
within 5 years of the date of purchase, provided that you return it to us with
proof of purchase. A product becomes defective where it fails due to fault in
the material or workmanship, but not where the failure is caused by an
accident, misuse or neglect. This guarantee does not effect your rights under
statute or common law.
Points to Remember
• Installation should be carried out by a competent DIY person. If in doubt
consult a qualified electrician.
• The electricity supply must be disconnected whist carrying out the
installation.
• An earth connection must be made for safety.
• The Multi Sensor Switch is for internal siting only. Wall Sensor Detectors
are mounted externally.
• Use the 2 strips of insulating sleeve (supplied) to insulate the 2 core low
voltage cable run inside the Multi Sensor Switch.
• Wall Sensor Detectors should be mounted at a height of 2
.
5 metres. At this
height the detector can be adjusted within minimum and maximum
settings. Refer to adjust detection range setting.
• Set light level/time on controls as shown under section heading.
• In normal use a built-in light sensor prevents daylight operation unless
light adjuster is set to day and night operation.
• False alarms may occur (see siting).
• The Sensor detector is more sensitive to movement across the detector
rather than directly towards or away from it.
• To help distinguish in what zone an intrusion has occurred:
ZONE 1 buzzer sounds a continuous bleep – bleeeeeep ZONE 2 buzzer
sounds a fast Intermittent bleep –bleepbleepbleepbleep
Walk Testing
Before commencing the walk test turn the Light level adjuster on the Multi
Sensor Switch to the day and night setting and both zone 1 and 2 light
on time adjusters to the minimum light on time setting.
Switch on the mains electricity supply to the Multi Sensor Switch and wait 20
seconds for the switch to stablilise.
Starting at a distance greater than 15 meters from the Wall Sensor Detector
walk across the front of the unit gradually
moving closer. Note the position where
detection occurs. The light will remain on for
approximately 3 seconds. Continue this
pattern to establish the full extent of coverage.
Reset the light level and light on time controls
on the controlling switch. Commissioning is
now complete.