Please keep these
instructions carefully
RCD METAL FUSED
CONNECTION UNIT
●
Provides additional protection
against the dangers of
electrocution.
●
Eliminates the need for plug-in
circuit breakers.
●
Protects appliances from
Red Flag status
indicator shows
red for ‘
possible fire hazard.
●
Extra fast action - trips out
within 40 milliseconds at
150mA trip current.
●
Latching for continuous
operation after supply
interruption.
●
Disconnects both Live and
Type 4904 S
30mA 1An
Double Pole
Indicator below
Reset (R) Button
Black: OFF
ALWAYS TEST
BEFORE USE
Press Test (T)
button, red indicator
should disappear.
If not, do not use.
Press Reset (R)
after testing.
Neutral connections leaving
Earth connection intact.
●
Supplied with BS surface
mounted wall box (40mm deep).
●
Full instructions enclosed.
Supplied with BS
surface mounted wall
box (40mm deep)
ON’
Red: ON
Reset button
Strong Metal
Construction
Test button for
safety checks
Specifications
Operating Voltage: 230V AC 50Hz
Current Rating: 13A
Rated Trip Current: 30 mA
Trip Speed: BS7288 - 40ms
RCD Type: Double pole - latching.
Continues to Lost Neutral/pulsating
Protect With: DC earth fault.
Conforms to Directives: 73/23/EEC & 89/336/EEC
Conforms to BS: Relevant clauses of
Dimensions (mm): 85 (H) x 85 (W) x 49 (D)
Suitable for both 2 and 3
wire appliances.
BS1363 and BS7288
Helpline 020 8450 0515
Call now for a free range brochure on
For further information contact:
Timeguard Ltd., Victory Park, 400
Edgware Road, London NW2 6ND
Or visit our website www.timeguard.com
020 8452 1112
Model RCD16ML
Designed & Manufactured in the U.K.
67-501-02