Руководство по эксплуатации включает в себя гарантийный талон
CONTENTS
1. Important information
2. Safety rules
3. Specification
4. Description of the unit
5. Scope of delivery
6. Appliance operation
7. Cartridge filter
8. Cleaning and maintenance
9. Troubleshooting
2
3
4
4
5
5
6
7
7
Dear customer!
We thank you for your happy choice! You’ve bought an air
humidifier TIMBERK. It will serve you for a long time. Please,
read this manual carefully before operating the device!
Humidifier is used to raised relative humidity level up, improving
microclimate. It helps to eliminate problems connected with
low air humidity.
1. IMPORTANT INFORMATION
The manufacturer reserves the right to make changes in the design,
scope of delivery or product manufacturing process in order to improve
its properties without any prior notice of the customer. The text and digital
designations in this instruction manual may contain misprints.
If after reading the instruction manual you still have question as to the
operation and use of the unit, contact the seller or the specialized service
center for clarification. The product has a tag specifying all necessary
technical data and other useful information about the unit.
Use this unit only for the purpose, listed in this manual.
The humidifier is intended to humidify room air. Comfortable conditions are
provided at relative air humidity of 40 to 60%. Insufficient air humidity results
in dehumidification of mucous membranes which in its turn is the cause of
decrease in immunity, head ache, cracking of lips, “sandpaper” in the eyes,
also enables development of infection and causes respiratory illnesses,
fatigue, increased eye fatigue and worsening of attention concentration,
and has negative effect on pets and indoor plants, and causes increased
dust generation and electrostatic charging of synthetic fabrics.
2
www.timberk.com • electric humidifier
2. SAFETY RULES
Prior to using the humidifier please read this instruction manual carefully
and keep it for future reference.
When using the unit, you need to follow a number of precautions. Improper
operation as a result of ignoring precautions may harm health of the
user and other people, as well as damage their property. The humidifier
is intended to operate in living quarters provided specified operation
conditions are observed. Inappropriate operation of the humidifier may
cause situation, dangerous for people’s lives and health.
The electrical unit must be supervised when in operation, especially if there
are children nearby. The unit is not intended for use by people (including
children) with reduced physical, sensory or mental capabilities, or lacking
experience and knowledge, unless they have been given supervision or
instruction as to the use of the unit by an individual responsible for their
safety. Children should be supervised to ensure they do not play with the
unit.
Do not use the unit for purposes not specified by this instruction manual.
The humidifier must not be used if its power cord or plug is damaged, as
well as if the humidifier is inoperable, damaged upon falling down or due
to other circumstances. The humidifier must be used only fully assembled.
To avoid being burned do not touch the humidifier’s membrane when it
is operating. The membrane gets very heated due to high membrane’s
oscillation frequency.
NOTE:
High-frequency oscillations of the ultrasonic
humidifier membrane are noiseless and safe for
people and pets.
To avoid electric shock, a damaged power supply unit must be replaced
only in authorized service centers by qualified specialists. To avoid electric
shock, do not place the power cord next to heating appliances and
flammable or combustible substances.
To avoid injuries and property damage do not try to repair the humidifier
by yourself. To repair the humidifier contact the manufacturer’s authorized
service center.
Take the power cord out from an electric outlet in the following cases: prior
to water discharge and filling of the tank; prior to cleaning and technical
maintenance; prior to assembly/disassembly of humidifier’s elements; prior
to relocating the humidifier.
Install the humidifier on an even dry surface. Steam, coming out from the
humidifier, can damage surfaces it comes into contact with. Do not install
the humidifier on the floor, as well as in close vicinity to heating appliances,
walls, furniture and other things.
The manufacturer and the seller are not responsible for damages, incurred
due to improper location of the humidifier.
The humidifier should be installed on some sort of an elevation, for example,
on a table, stand, etc. at the distance of not less than 60 cm from the floor
and not less than 10 cm from the wall.
It is forbidden to pour water into the humidifier through the atomizer.
Do not immerse the humidifier into water or other fluids.
Do not install the humidifier in the aisle or other places, where it can be
pushed, tipped over, etc.
If you do not use the humidifier, disconnect it from the power line.
Do not lay the power cord under a carpet or other things. Place the
humidifier so that you couldn’t touch the power cord.
Do not use the humidifier in damp rooms. Excessive room humidity may
cause water condensation on windows and furniture. If this is the case,
turn off the humidifier.
Do not let foreign objects get into the humidifier.
Do not obstruct the humidifier’s air intake and atomizer by foreign objects.
Do not sit, stand and put heavy objects on the humidifier.
To avoid damaging the humidifier, do not add essential oils, preservation
agents, fragrances and other foreign admixtures into the water used for
humidification. The manufacturer and the seller are not responsible for
damage of the humidifier incurred as a result of failure to comply with this
requirement.
When disconnecting the humidifier from the power line, do not pull the
power cord and do not touch it with wet hands.
Make sure to take this information into consideration.
www.timberk.com • electric humidifier
3
3. SPECIFICATIONS
4. DESCRIPTION OF THE UNIT
Table 1
Specifications
Humidification capacity ml/h300
Power supply V/Hz220~/50
Water tankL3.7
Rated power consumption W25
Rated current A0.11
Protection class rating -IPX0
Electrical protection class rating-II
Device dimensions mm 232x247x505
Net weightkg3.1
* This performance is specified at the mode of hot steam.
Unit of
measurement
THU UL 28 (BL)
THU UL 28 (BW)
The manufacturer reserves the right to change component parts of the product
for various delivery batches without any prior notice (including components to
be poured/filled in), not affecting the main technical parameters of the product
or improving them, as well as not violating quality standards and statutory
regulations, adopted within the country of manufacture/transit/sales, by such
changes.
This can cause changes in the weight and overall dimensions of the product,
but not more than by +\- 5-20% (subject to variation for different types of the
product).
1
6
7
Fig.1
1. Device body
2. Water tank cap with
3. Water tank
4. Carrying handle
5. Power cord
6. Hidden touch area
7. Stand
8. Tank cover with valve
2
3
4
8
5
4
www.timberk.com • electric humidifier
1
2
1. Power on / off button
2, 5. The button for setting the required humidity level from 45 to 90%.
3, 4. The steam output intensity selection button: low, medium, high
6. Set timer button to turn off the device
7. Button for activating the humidity control function
8. Ionization function ON / OFF button
88
HUMID
%RM
Fig. 2
3
5
4
1. Power on / off button
2. On / Off button for air ionization function
3. Button for setting the timer to turn off the device
4. The button for setting the required humidity level from 45 to 90%.
5. Display
Remote control
1
3
6
8
2
4
5
7
Fig. 3
5. SCOPE OF DELIVERY
1. Air humidifier – 1 pc.
2. Instruction and warranty card - 1 pc.
3. Package – 1 pc.
4. Remote control – 1 pc.
5. Filter – 1 pc.
6.APPLIANCE OPERATION
Switching the device on
Place the case on the stand, fill the tank with water and install the device
strictly vertically on a flat dry surface, then connect the device to the mains
by inserting the plug of the power cord into the outlet, while the illumination
of the power button flashes on the control panel for 5 minutes.
Press the «ON / OFF» button, the device will automatically start to work,
the button illumination will light and the display of the steam output and the
current humidity value will appear on the display.
At the very beginning of the work, the level of spraying can be unstable,
due to the difference in temperature and water quality. It will take some time
for the water to vaporize on the ultrasonic membrane, and this process
has stabilized. After 10-25 minutes of operation, the spray level gradually
stabilizes.
Steam output intensity adjustment
To change the intensity of the steam output, press the «ON / OFF» button
several times, the intensity of the steam output will vary: low, medium, high,
and accordingly the intensity of the steam output will be displayed by the
indicators on the display.
www.timberk.com • electric humidifier
5
Comfortable conditions are achieved with a relative humidity of 40 to
60%. You can determine the favorable humidity level for you by your own
sensations, or you can use a special hygrometer (not supplied) for this
purpose, which measures the relative humidity level.
IMPORTANT!
If the device generates a large amount of condensate
on the top of the device and on objects near it, it is
necessary to reduce the intensity of the steam output.
Air ionization function
To activate or deactivate the air ionization function, press the ION button.
When the button is pressed, the negative ion generator turns on / off, the
ionization indicator on the control panel lights up / goes out.
The ionizer generates negatively charged ions (anions) and refreshes the
air in the room. Anions strengthen the nervous and circulatory system,
improve lung function and serve as effective protection against respiratory
diseases (such as asthma and pneumonia). Anions clean the air of dust
and smoke.
Humidity control function
When this function is activated, the device will automatically turn off when
the set humidity level is reached and automatically turn on when the
humidity level falls below the set humidity level.
To activate the humidity control function, press the «HUMIDITY» button. The
display shows the set humidity value. Continue to press the «HUMIDITY»
button to set the desired humidity level from 45% to 90%, in 5% increments
and select the desired humidity level. After setting, the set value flashes in
the display for 3 seconds, after which the value of the current humidity is
displayed. Select 90% and press the HUMIDITY button again to disable
this function.
Timer to turn off the device
To set the timer time to turn off the device, press the «TIMER» button
several times, and the set timer time until the device is switched off will
be reflected on the display from 1 to 12 hours, in steps of 1 hour. Within
3 seconds after setting, the set value will be memorized and will not be
displayed on the display. The device will switch off after the set time interval
has elapsed.
Turning off the instrument or setting the timer value [0] will cancel the timer
to turn off the device.
Automatic shut-off in the absence of water
If the water level in the tank drops below the minimum permissible
level, the ultrasonic membrane of the device will automatically shut off,
an audible signal will sound and the display will turn on and the water
absence indicator « « will flash. To continue the operation of the device it
is necessary to fill the reservoir with water according to item 6 «Filling the
reservoir with water», then connect the device to the electrical network.
Remote control (remote control)
With the remote control it is possible to control all functions of the device in
an effective range of 6 meters. The description of the buttons is shown in
figure 3. The remote control can be placed on the right side of the side in
the upper part of the device housing with the help of an integrated magnet.
Sound notification
When the appliance is switched on and off, and when the buttons are
pressed, a beep is emitted.
Switching off the device
To turn off the device, press and hold the «ON / OFF» button for 3 seconds
and unplug the appliance from the mains.
7. FILTER-CARTRIDGE FOR WATER SOFTENING
The kit includes 1 filter cartridge installed on the cover of the water tank with
a valve, with balls of mineral stone, which has strong absorbent properties.
The filter absorbs elements of heavy metals such as lead, chrome, mercury,
zinc, etc. Disinfects water and restores normal acidity (PH).
The service life of the filter is 4-6 months, depending on the quality of the
water used and the frequency of use of the device.
If a white coating appears on the objects around the humidifier when using
the humidifier, this may be due to the following reasons:
1. The water that is used contains a large amount of magnesium or calcium.
Use water that has been previously cleaned with a household water filter.
2. Remains of calcium and magnesium salts accumulated in the inside of
the device. It is necessary to clean the inside of the device.
3. Steam deposits on the surface of suspended dust in the air.
4. The properties of the water softening filter have deteriorated. It is
necessary to replace the filter to soften the water.
6
www.timberk.com • electric humidifier
8. CLEANING AND MAINTENANCE
Before cleaning the device make sure that the plug is disconnected from
the wall outlet. Otherwise, it may result in electric shock.
Before cleaning, wait until the cooling water in the ground, so as not to
burn your hands. Spend device cleaning once or twice a week.
To clean the outer surface of the unit with a damp soft cloth.
To avoid electric shock, do not scratch or damage the device while
cleaning elements.
Do not use when cleaning the device thinner, benzene, dimethyl benzene,
stiff brush, talcum powder and other materials, except water.
Wipe any remaining water inside the base with a damp, soft cloth.
To remove the remaining water in the small details, you can use a soft
brush, then wipe it again with a soft cloth.
In the formation of dirt on the membrane, clean it with a soft brushes. Use
a soft brush to erase the remnants of water on the surface of the device,
and then wipe it again with a soft cloth.
Rinse water tank and a clean water dispenser.
After removal of the residual water from the surface of the sprayer, wipe it
with a soft cloth. Clean the outside surface with a damp, soft cloth.
IMPORTANT!
To avoid deformation or wear of working surfaces,
resulting in decreased atomizing or other malfunctions,
do not use metallic brushes, blades or talc powder
to wipe the atomizer’s surface. The water tank may
leak upon heavy impacts. In case of water leakage,
immediately stop using the unit and contact a service
center. To keep the unit dry, remove water after cleaning
and make sure to dry the unit’s case. Make sure that
there is no water left inside the unit’s case. Prior to a
long break in using the unit, dry its surface and pack it
into a plastic bag, then put it into a box. Store the unit in
a low-humidity room. Storing the unit undried results in
generation of mold
9. TROUBLESHOOTING
In case of emergencies use troubleshooting methods, listed in Table 2.
If it is impossible to remedy problems by the listed methods, contact the
manufacturer’s service center.
Table 2
ProblemPossible causeRemedy
There is no problem. If you need to switch
to the intensive mode of operation, turn the
regulator handle all the way to the right.
Set maximum capacity. The humidifier’s
capacity will go up after a while.
Connect the power cord into the outlet
carefully
1. Clean the humidifier’s membrane with a
special brush
2. Use filtered water
Clean the unit according to the cleaning
and servicing instructions and fill the tank
with fresh water
Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
1. Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
2. Clean the unit according to the cleaning
and servicing instructions.
You need to contact an authorized service
center
Poor atomizing (insufficient
capacity)
No atomizing
There is white deposit on objects
around the humidifier (salts,
separating out from water)
Steam has an unpleasant odor
Condensate is formed on the
upper part of the humidifier and
on surrounding objects, when it is
operating.
Water appears next to the humidifier,
when it is operating.
Water appears next to the humidifier,
when it is not operating
The unit is operating in the minimized
mode (low atomizing frequency)
The atomizer is cloggedClean the atomizer.
Temperature of water in the tank is too low
The power cord is poorly connected
to the outlet
1. Lime deposits have formed on the
membrane
2. There is a lot of salts in the water used
(calcium and magnesium)
Stale water is used
Remains of stale water or waste have
accumulated in the unit’s case or the
atomizer
1. High humidification intensity is set.
2. High room humidity and temperature.
1. High humidification intensity is set.
2. Lime deposits have formed on the
membrane and in grooves for water (in
the unit’s base).
Water tank is leaking