Timberk THU UL 24 E WB User Manual [ru]

Instruction manual
Руководство по эксплуатации
Outlook of devices, aslo colour scores can be revised without any special advance notices.
Производитель вправе менять внешний вид прибора и цветовую гамму при­бора без специального уведомления.
Электрический увлажнитель воздуха
Модели/Models:
Electric
THU UL 24 E (WB)
Цвет/Color: (WB) - белый с чёрным /
white with black
Руководство по эксплуатации включает в себя гарантий­ный талон
CONTENTS
1. Important information
2. Safety rules
3. Specication
4. Description of the unit
5. Scope of delivery
6. Appliance operation
7. Operation of the device
8. Cleaning and maintenance
9. Troubleshooting
2 3 4 4 4 5 5 6 7
Dear customer!
We thank you for your happy choice! You’ve bought an air humidier TIMBERK. It will serve you for a long time. Please, read this manual carefully before operating the device!
Humidier is used to raised relative humidity level up, improving microclimate. It helps to eliminate problems connected with low air humidity.
1. IMPORTANT INFORMATION
The manufacturer reserves the right to make changes in the design, scope of delivery or product manufacturing process in order to improve its properties without any prior notice of the customer. The text and digital designations in this instruction manual may contain misprints.
If after reading the instruction manual you still have question as to the operation and use of the unit, contact the seller or the specialized service
center for clarication. The product has a tag specifying all necessary
technical data and other useful information about the unit. Use this unit only for the purpose, listed in this manual.
The humidier is intended to humidify room air. Comfortable conditions are provided at relative air humidity of 40 to 60%. Insufcient air humidity results in dehumidication of mucous membranes which in its turn is the cause of
decrease in immunity, head ache, cracking of lips, “sandpaper” in the eyes, also enables development of infection and causes respiratory illnesses, fatigue, increased eye fatigue and worsening of attention concentration, and has negative effect on pets and indoor plants, and causes increased dust generation and electrostatic charging of synthetic fabrics.
2
www.timberk.com • electric humidier
2. SAFETY RULES
Prior to using the humidi er please read this instruction manual carefully
and keep it for future reference. When using the unit, you need to follow a number of precautions. Improper
operation as a result of ignoring precautions may harm health of the
user and other people, as well as damage their property. The humidi er is intended to operate in living quarters provided speci ed operation conditions are observed. Inappropriate operation of the humidi er may cause situation, dangerous for people’s lives and health.
The electrical unit must be supervised when in operation, especially if there are children nearby. The unit is not intended for use by people (including children) with reduced physical, sensory or mental capabilities, or lacking experience and knowledge, unless they have been given supervision or instruction as to the use of the unit by an individual responsible for their
safety. Children should be supervised to ensure they do not play with the
unit.
Do not use the unit for purposes not speci ed by this instruction manual. The humidi er must not be used if its power cord or plug is damaged, as
well as if the humidi er is inoperable, damaged upon falling down or due to other circumstances. The humidi er must be used only fully assembled.
To avoid being burned do not touch the humidi er’s membrane when it is operating. The membrane gets very heated due to high membrane’s
oscillation frequency.
NOTE:
High-frequency oscillations of the ultrasonic humidifi er membrane are noiseless and safe for
people and pets.
To avoid electric shock, a damaged power supply unit must be replaced
only in authorized service centers by quali ed specialists. To avoid electric
shock, do not place the power cord next to heating appliances and
 ammable or combustible substances. To avoid injuries and property damage do not try to repair the humidi er
by yourself. To repair the humidi er contact the manufacturer’s authorized
service center.
Take the power cord out from an electric outlet in the following cases: prior
to water discharge and  lling of the tank; prior to cleaning and technical maintenance; prior to assembly/disassembly of humidi er’s elements; prior to relocating the humidi er.
Install the humidi er on an even dry surface. Steam, coming out from the humidi er, can damage surfaces it comes into contact with. Do not install the humidi er on the  oor, as well as in close vicinity to heating appliances,
walls, furniture and other things. The manufacturer and the seller are not responsible for damages, incurred
due to improper location of the humidi er. The humidi er should be installed on some sort of an elevation, for example,
on a table, stand, etc. at the distance of not less than 60 cm from the  oor
and not less than 10 cm from the wall.
It is forbidden to pour water into the humidi er through the atomizer. Do not immerse the humidi er into water or other  uids. Do not install the humidi er in the aisle or other places, where it can be
pushed, tipped over, etc.
If you do not use the humidi er, disconnect it from the power line.
Do not lay the power cord under a carpet or other things. Place the
humidi er so that you couldn’t touch the power cord. Do not use the humidi er in damp rooms. Excessive room humidity may
cause water condensation on windows and furniture. If this is the case,
turn off the humidi er. Do not let foreign objects get into the humidi er. Do not obstruct the humidi er’s air intake and atomizer by foreign objects. Do not sit, stand and put heavy objects on the humidi er. To avoid damaging the humidi er, do not add essential oils, preservation
agents, fragrances and other foreign admixtures into the water used for
humidi cation. The manufacturer and the seller are not responsible for damage of the humidi er incurred as a result of failure to comply with this
requirement.
When disconnecting the humidi er from the power line, do not pull the
power cord and do not touch it with wet hands. Make sure to take this information into consideration.
www.timberk.com • electric humidifi er
3
3. SPECIFICATIONS
Table 1
Specifications
Humidification capacity ml/h 280
Power supply V/Hz 220-240~/50
Water tank L 3
Rated power consumption W 20
Rated current A 0,1
Protection class rating - IP20
Electrical protection class rating - Class II
Device dimensions mm 200x200x268
Net weight kg 1,3
The manufacturer reserves the right to change component parts of the product for various delivery batches without any prior notice (including components to
be poured/lled in), not affecting the main technical parameters of the product
or improving them, as well as not violating quality standards and statutory
regulations, adopted within the country of manufacture/transit/sales, by such
changes. This can cause changes in the weight and overall dimensions of the product,
but not more than by +\- 5-20% (subject to variation for different types of the product).
Unit of
measurement
THU UL 24 E (WB)
4. DESCRIPTION OF THE UNIT
Fig.1
1. The atomizer
2. Carrying handle
3. Water tank
4. Body
5. Aroma
6. Cover with water tank valve
7. Control panel
8. Ventilation opening
9. The ultrasonic membrane
10. Float
4
www.timberk.com • electric humidier
6. FILLING THE TANK WITH WATER
1
5
2
HUMID
TIMER
%RH
2
4
8
1
6
4
1. Remove the tank from the stand and remove the top cover from it.
2. Pour water in the reservoir no higher than the maximum water level scale «MAX».
3. Install the top tank cover and install it on the stand.
4. Check that the tank on the stand is installed securely, then connect the
plug of the power cord to an electrical outlet.
7
8
3
Fig.2
1. Power ON / OFF button
2. Timer button
3. LED light button
4. Mist intensity button: low, medium, high
5. Indicator of absence of water
6. Indication of the current humidity
7. Indication of steam output intensity
8. Timer indicators (TIMER): switch off the device after 1h, 2h, 4h, 8h
5. SCOPE OF DELIVERY
1. Air humidier – 1 pc.
2. Instruction manual and warranty card - 1 pc.
3. Package – 1 pc.
4. Brush-1 pc.
7. OPERATION OF THE DEVICE
Switching the device on
Set the device strictly vertically on a at, dry surface, then connect the device to the electrical network, previously lling the reservoir with water the ON/OFF blue indicator on the dispaly will light up Press the «ON / OFF»
button, the device will automatically start to work, the button illumination will light and the display of the steam output and the current humidity value will appear on the display. The appliance will turn on, the operation
indicator will light up on the control panel and steam will ow from the
sprayer. At the very beginning of this operation, the level of spraying can be unstable, which is caused by the temperature difference and water quality. It will take a short time for this process to stabilize.
Steam output intensity adjustment
To change the intensity of the steam output, press the «Mist intensity» button several times, the intensity of the steam output will vary: high, medium, low, and accordingly the intensity of the steam output will be
displayed by the indicators on the panel. Comfortable conditions are
achieved with a relative humidity of 40 to 60%. You can determine the favorable humidity level for you by your own sensations, or you can use a special hygrometer (not supplied) for this purpose, which measures the relative humidity level.
www.timberk.com • electric humidier
5
Timer to turn off the device
To set the timer to turn off the device, press the «timer» button On the control panel several times, while the set timer time before the
device is turned off will be re ected on the display.
Night mode
In this mode, the brightness of the display is automatically reduced. To activate «SLEEP» mode, press and hold the LED light button on the control panel for 3 second sand the display will go out. To turn off this mode, «Press the LED light» button on the control panel again, while the «SLEEP» mode will turn off.
The humidi er is equipped with color illumination
When you turn on the backlight, the different colors will change in turn. To turn on the color light, press color light, press the LED light button. To
turn off the color light, press the button again on/off button amend to LED
light button.
Automatic shut-off in the absence of water
If the water level in the tank drops below the minimum allowable value, the ultrasonic membrane of the device will automatically turn off and a red indicator will light up on the control panel with 3 buzzing sound.
Aromatization
The device is equipped with an aroma capsule. When you add aromatic oil to it, air is aromatized. Aromatic oil is not included in the scope of supply.
Switching off the device
To turn off the device, press the «ON / OFF» button and unplug the
appliance from the mains.
8. CLEANING AND MAINTENANCE
Before cleaning the device make sure that the plug is disconnected from the wall outlet. Otherwise, it may result in electric shock. Before cleaning, wait until the cooling water in the ground, so as not to burn your hands. Spend device cleaning once or twice a week. To clean the outer surface of the unit with a damp soft cloth. To avoid electric shock, do not scratch or damage the device while cleaning elements. Do not use when cleaning the device thinner, benzene, dimethyl benzene, stiff brush, talcum powder and other materials, except water. Wipe any remaining water inside the base with a damp, soft cloth. To remove the remaining water in the small details, you can use a soft brush, then wipe it again with a soft cloth. In the formation of dirt on the membrane, clean it with a soft brushes. Use a soft brush to erase the remnants of water on the surface of the device, and then wipe it again with a soft cloth. Rinse water tank and a clean water dispenser. After removal of the residual water from the surface of the sprayer, wipe it
with a soft cloth. Clean the outside surface with a damp, soft cloth.
IMPORTANT!
To avoid deformation or wear of working surfaces, resulting in decreased atomizing or other malfunctions, do not use metallic brushes, blades or talc powder to wipe the atomizer’s surface. The water tank may leak upon heavy impacts. In case of water leakage, immediately stop using the unit and contact a service center. To keep the unit dry, remove water after cleaning and make sure to dry the unit’s case. Make sure that there is no water left inside the unit’s case. Prior to a long break in using the unit, dry its surface and pack it into a plastic bag, then
put it into a box. Store the unit in a low-humidity room.
Storing the unit undried results in generation of mold
6
www.timberk.com • electric humidifi er
9. TROUBLESHOOTING
In case of emergency, please, use the troubleshooting methods shown in tables. If it is impossible to solve problems with these methods, apply to the service center.
Problem Possible cause Remedy
There is no problem. If you need to switch to the intensive mode of operation, turn the regulator handle all the way to the right.
Set maximum capacity. The humidifier’s capacity will go up after a while.
Connect the power cord into the outlet carefully
1. Clean the humidifier’s membrane with a special brush
2. Use filtered water
Clean the unit according to the cleaning and servicing instructions and fill the tank with fresh water
Lower the humidification intensity by turning the on/off and steam outflow intensity regulator counterclockwise.
1. Lower the humidification intensity by turning the on/off and steam outflow intensity regulator counterclockwise.
2. Clean the unit according to the cleaning and servicing instructions.
You need to contact an authorized service center
Poor atomizing (insufficient capacity)
No atomizing
There is white deposit on objects around the humidifier (salts, separating out from water)
Steam has an unpleasant odor
Condensate is formed on the upper part of the humidifier and on surrounding objects, when it is operating.
Water appears next to the humidifier, when it is operating.
Water appears next to the humidifier, when it is not operating
The unit is operating in the minimized mode (low atomizing frequency)
The atomizer is clogged Clean the atomizer.
Temperature of water in the tank is too low
The power cord is poorly connected to the outlet
1. Lime deposits have formed on the membrane
2. There is a lot of salts in the water used (calcium and magnesium)
Stale water is used
Remains of stale water or waste have accumulated in the unit’s case or the atomizer
1. High humidification intensity is set.
2. High room humidity and temperature.
1. High humidification intensity is set.
2. Lime deposits have formed on the membrane and in grooves for water (in the unit’s base).
Water tank is leaking
www.timberk.com • electric humidier
7
СОДЕРЖАНИЕ
1. Важная информация
2. Правила безопасности
3. Технические характеристики
4. Описание прибора
5. Комплектация
6. Наполнение резервуара водой
7. Эксплуатация прибора
8. Очистка и обслуживание
9. Поиск и устранение неисправностей
10. Гарантийный талон
Уважаемый покупатель!
8
9 10 10 11 11 11 12 13 15
Благодарим Вас за удачный выбор и приобритение увлаж­нителя воздуха ТIMBERK. Он прослужит Вам долго.
Увлажнитель воздуха повышает относительную влажность воздуха в помещении и нормализует микроклимат, помо­гая избежать пагубных явлений пониженной влажности.
Просим вас внимательно ознакомиться с руководством по эксплуатации перед тем, как вы начнете эксплуатацию из­делия!
1. ВАЖНАЯ ИНФОРМАЦИЯ
Производитель оставляет за собой право без предварительного уве­домления покупателя вносить изменения в конструкцию, комплекта­цию или технологию изготовления изделия с целью улучшения его свойств. В тексте и цифровых обозначениях данного руководства могут быть допущены опечатки.
Если после прочтения руководства у Вас останутся вопросы по рабо­те и эксплуатации прибора, обратитесь к продавцу или в специализи­рованный сервисный центр для получения разъяснений. На изделии присутствует этикетка, на которой указаны все необходимые техни­ческие данные и другая полезная информация о приборе.
Используйте прибор только по назначению, указанному в данном ру­ководстве.
Увлажнитель предназначен для увлажнения воздуха в помещении. Комфортные условия достигаются при относительной влажности воздуха от 40 до 60%. Недостаточная влажность воздуха приводит к высушиванию слизистых оболочек, что в свою очередь является причиной снижения иммунитета, головной боли, растрескивания губ, жжения в глазах, благоприятствует развитию инфекции и за­болеваниям дыхательных путей, вызывает утомление, приводит к повышенной усталости глаз и ухудшению концентрации внимания, отрицательно влияет на состояние домашних животных и комнатных растений, приводит к усилению пылеобразования, повышению элек­тростатического заряда синтетических тканей.
8
www.timberk.com • электрический увлажнитель воздуха
Loading...
+ 16 hidden pages