Timberk THU UL 17 W User Manual [ru]

Instruction manual
Руководство по эксплуатации
Outlook of devices, aslo colour scores can be revised without any special advance notices.
Производитель вправе менять внешний вид прибора и цветовую гамму при­бора без специального уведомления.
Электрический увлажнитель воздуха
Модели/Models:
THU UL 17 (W) THU UL 17 (BL)
Цвет/Color: (W) - белый / white
(BL) -черный / black
Руководство по эксплуатации включает в себя гарантий­ный талон
CONTENTS
1. Important information
2. Safety rules
3. Specification
4. Description of the unit
5. Scope of delivery
6. Filling of tank with water
7. Operation of the unit
8. Water softening filter cartridge
9. Cleaning and maintenance
10. Transportation and storage
11. Troubleshooting
12. Utilizatione
2 3 4 4 5 5 6 6 7 8 8 8
Dear customer!
We thank you for your happy choice! You’ve bought an air humidifier TIMBERK. It will serve you for a long time. Please, read this manual carefully before operating the device!
Humidifier is used to raised relative humidity level up, improving microclimate. It helps to eliminate problems connected with low air humidity.
1. IMPORTANT INFORMATION
The manufacturer reserves the right to make changes in the design, scope of delivery or product manufacturing process in order to improve its properties without any prior notice of the customer. The text and digital designations in this instruction manual may contain misprints.
If after reading the instruction manual you still have question as to the operation and use of the unit, contact the seller or the specialized service center for clarification. The product has a tag specifying all necessary technical data and other useful information about the unit.
Use this unit only for the purpose, listed in this manual. The humidifier is intended to humidify room air. Comfortable conditions are
provided at relative air humidity of 40 to 60%. Insufficient air humidity results in dehumidification of mucous membranes which in its turn is the cause of decrease in immunity, head ache, cracking of lips, “sandpaper” in the eyes, also enables development of infection and causes respiratory illnesses, fatigue, increased eye fatigue and worsening of attention concentration, and has negative effect on pets and indoor plants, and causes increased dust generation and electrostatic charging of synthetic fabrics.
2
www.timberk.com • electric humidifier
2. SAFETY RULES
Prior to using the humidifier please read this instruction manual carefully and keep it for future reference.
When using the unit, you need to follow a number of precautions. Improper operation as a result of ignoring precautions may harm health of the user and other people, as well as damage their property. The humidifier is intended to operate in living quarters provided specified operation conditions are observed. Inappropriate operation of the humidifier may cause situation, dangerous for people’s lives and health.
The electrical unit must be supervised when in operation, especially if there are children nearby. The unit is not intended for use by people (including children) with reduced physical, sensory or mental capabilities, or lacking experience and knowledge, unless they have been given supervision or instruction as to the use of the unit by an individual responsible for their safety. Children should be supervised to ensure they do not play with the unit.
Do not use the unit for purposes not specified by this instruction manual. The humidifier must not be used if its power cord or plug is damaged, as
well as if the humidifier is inoperable, damaged upon falling down or due to other circumstances. The humidifier must be used only fully assembled.
To avoid being burned do not touch the humidifier’s membrane when it is operating. The membrane gets very heated due to high membrane’s oscillation frequency.
NOTE:
High-frequency oscillations of the ultrasonic humidifier membrane are noiseless and safe for people and pets.
To avoid electric shock, a damaged power supply unit must be replaced only in authorized service centers by qualified specialists. To avoid electric shock, do not place the power cord next to heating appliances and flammable or combustible substances.
To avoid injuries and property damage do not try to repair the humidifier by yourself. To repair the humidifier contact the manufacturer’s authorized
service center. Take the power cord out from an electric outlet in the following cases: prior
to water discharge and filling of the tank; prior to cleaning and technical maintenance; prior to assembly/disassembly of humidifier’s elements; prior to relocating the humidifier.
Install the humidifier on an even dry surface. Steam, coming out from the humidifier, can damage surfaces it comes into contact with. Do not install the humidifier on the floor, as well as in close vicinity to heating appliances, walls, furniture and other things.
The manufacturer and the seller are not responsible for damages, incurred due to improper location of the humidifier.
The humidifier should be installed on some sort of an elevation, for example, on a table, stand, etc. at the distance of not less than 60 cm from the floor and not less than 10 cm from the wall.
It is forbidden to pour water into the humidifier through the atomizer. Do not immerse the humidifier into water or other fluids. Do not install the humidifier in the aisle or other places, where it can be
pushed, tipped over, etc. If you do not use the humidifier, disconnect it from the power line. Do not lay the power cord under a carpet or other things. Place the
humidifier so that you couldn’t touch the power cord. Do not use the humidifier in damp rooms. Excessive room humidity may
cause water condensation on windows and furniture. If this is the case, turn off the humidifier.
Do not let foreign objects get into the humidifier. Do not obstruct the humidifier’s air intake and atomizer by foreign objects. Do not sit, stand and put heavy objects on the humidifier. To avoid damaging the humidifier, do not add essential oils, preservation
agents, fragrances and other foreign admixtures into the water used for humidification. The manufacturer and the seller are not responsible for damage of the humidifier incurred as a result of failure to comply with this requirement.
When disconnecting the humidifier from the power line, do not pull the power cord and do not touch it with wet hands.
Make sure to take this information into consideration.
www.timberk.com • electric humidifier
3
3. SPECIFICATIONS
Table 1
Specifications
Humidification capacity ml/h 400*
Power supply V/Hz 220~/50
Tank capacity l 4
Rated power consumption W 105
Rated current A 0.5
Protection rating - IPХ0
Electric protection category - ll
Dimensions of the unit mm 281x182x182
Net weight kg 1.47
Recommended floor area m
* This performance is specified at the mode of hot steam.
The manufacturer reserves the right to change component parts of the product for various delivery batches without any prior notice (including components to be poured/filled in), not affecting the main technical parameters of the product or improving them, as well as not violating quality standards and statutory regulations, adopted within the country of manufacture/transit/sales, by such changes.
This can cause changes in the weight and overall dimensions of the product, but not more than by +\- 5-20% (subject to variation for different types of the product).
Unit of
measurement
2
Value
20-25
4. DESCRIPTION OF THE UNIT
Fig.1
1. Water tank cap with atomizer
2. Water tank
3. Water level control window
4. Base
5. Air coal filter
6. Air filter grill
7. Control panel
8. Water softening filter cartridge
9. Carbon filter
10. Ion resin filter
1
2 3
9
8
10
4
7
5
6
4
www.timberk.com • electric humidifier
1 2 3
Fig. 2
1. Warm mist
2. Power
3. Speed
5. SCOPE OF DELIVERY
1. Air humidifier – 1 pc.
2.Manual and warranty card - 1 pc.
3. Package – 1 pc.
4. Water softening filter – 3 pc.
6. FILLING THE TANK WITH WATER
1. Remove the water tank cap with the atomizer and then the water tank itself from the unit.
2. Take the tank handle and pull upwards.
3. Turn over the tank and unscrew the tank cap with the valve and the filter counterclockwise.
4. Fill the tank with water.
5. Screw the tank cap with the valve and the filter clockwise. Make sure that the tank cap is tightly secured. Make sure than the rubber ring is installed on the tank cap.
Failure to take all of the above measures may result in air ingress in the water tank and, as a result, break-down.
6. Install the tank and the water tank cap with the atomizer back to the unit.
IMPORTANT!
To avoid electric shock, prior to disassembling the unit (removing the tank), disconnect the unit from the power line! Do not fill the tank with other liquids but tap water.
Different composition of liquids has harmful effect on internal parts and causes failures.
Do not fill the unit or the water tank with such additives as essential oils, fragrances, cleaning agents, chemical medical drugs, warm water (above 40°), etc.
Otherwise, the water tank and internal parts of the unit will be damaged and inoperable.
Do not fill water directly into the internal part of the unit or the atomizer.
Water inside the unit may cause failure of the unit. Do not hit or throw the water tank. It may get damaged
resulting in water leaks. Do not use the unit in case if the water tank is heavily hit.
Immediately contact the technical support service or the maintenance and repair station.
Every day fill the tank with fresh water and keep the unit clean.
www.timberk.com • electric humidifier
5
7.OPERATION OF THE UNIT
Connect the unit to the power line, having filled the tank with water first. Press the on/off button, (the unit will automatically start operating), and the
current air humidity will show up on the display. At the very beginning of operation, the atomizing level may appear
unstable, which is caused by the temperature difference and water quality. It takes some time for water to start turning into steam on the ultrasonic membrane. After 10-25 minutes the atomizing level will gradually stabilize.
To select the required room humidity, press the humidity level setting button (5). The unit will automatically adjust the steam outflow intensity to reach the humidity level you have set.
To adjust the humidity level manually, press button (2), the steam outflow intensity will change (low, medium, high). This action will be shown on the display by indicators.
The display show the set humidity level and the current humidity level after the user finishes setting up. The display show the actual room temperature.
By pressing the timer set button (4), you can set the time for the unit to switch off in 1 – 12 hours.
To activate air ionizing, press the corresponding button (3). The ionizer generates negative ions (anions) and refreshes the room air.
Anions reinforce the nervous and the blood-vascular system, improve lungs performance and provide effective protection against respiratory illnesses (such as asthma and pneumonia). Anions clean air from dust and smoke.
Press the warm steam on/off button (6) to humidify by warm steam. When humidifying by warm steam, water heating is performed by means of the built-in heater. Water in the tank is heated and fed through the atomizer turning into warm steam. The unit’s efficiency improves thanks to the combined humidification (cold and warm steam).
NOTE!
It the warm steam function was activated when the unit was operating, then after the unit is switched off, the fan will keep on working for 5 minutes to cool down the heating element.
It will take about ten-twenty minutes to atomize warm steam (time required for water to be heating by the heater after it is switched on). The average warm steam temperature is 40°. Sometimes it is hard to feel the steam temperature due to the temperature difference and ambient humidity.
To deactivate the warm steam function, press button (6) again. To switch off the unit, press the on/off button.
NOTE!
Dear customer, When using the humidifier, you may come across
condensate generation on its upper part and objects next to it, including water accumulation, which is not a defect, but a feature of its operation. This feature may have several causes, listed in the table on page 14.
8. WATER SOFTENING FILTER CARTRIDGE
The unit’s scope of delivery includes 1 filter cartridge with balls out of mineral stone, installed on the water tank cap with the valve, 1 carbone filter (in set) and 1 ion resin filter (in set). Filter cartridge with balls out of mineral stone, which features strong absorbing properties. The filter absorbs elements of heavy metals such as lead, chrome, mercury, zinc, etc. It decontaminates water and restores normal pH level.
Filter’s life is 4-6 months, depending on the quality of water used and how often the unit is used.
If the white deposit appears on things around the humidifier when it is used, it may have the following causes:
1. Water used contains high amount of magnesium or calcium. You should use water that was preliminarily treated by a domestic water filter.
2. Residues of calcium and magnesium salts have accumulated inside the unit. You should clean inner parts of the unit.
3. Steam deposits suspended dust on a surface, contained in the air.
4. The water softening filter properties have deteriorated. You should replace the water softening filter.
6
www.timberk.com • electric humidifier
9. CLEANING AND MAINTENANCE
Prior to cleaning the unit make sure the power supply’s plug is disconnected from the outlet. Otherwise, it may cause electric shock.
Prior to cleaning wait until water, remaining in the unit’s case, completely cools down, to avoid getting burned.
Clean the unit once or twice a week.
9.1. Use a damp and soft fabric to wipe the unit’s external surface. To avoid electric shock do not scratch or damage elements of the unit
when cleaning. When cleaning, do not use solvents, benzene, xylene, scrub brush, talc
powder and other substances except for water.
9.2. Wipe off remains of water on the unit’s base using a damp and soft fabric.
To wipe of remains of water on small parts you can use a soft brush and then wipe them with a soft fabric again.
9.3. In case of dirt on the membrane, clean it with a brush.
9.4. Use a soft brush to wipe off remains of water on the surface of the atomizer’s nozzle, then wipe it with a soft fabric again.
9.5 Wash the water tank and the atomizer by clean water. Wash the cap with the valve carefully and lightly, otherwise it may cause water leaks through the cover.
After removing water from the atomizer’s surface clean it with a soft fabric. Clean the unit’s external surface with a damp and soft fabric.
9.6. Clean the air filter if:
- the air flow from the air outlet grill became weaker and the noise increased;
- the filter color has changed, which indicates that the filter is dirty.
IMPORTANT!
To avoid deformation or wear of working surfaces, resulting in decreased atomizing or other malfunctions, do not use metallic brushes, blades or talc powder to wipe the surface of the atomizer’s nozzle.
The water tank may leak upon heavy impacts. In case of water leakage, immediately stop using the unit
and contact a service center. To keep the unit dry, remove water after cleaning and
make sure to dry the unit’s case. Make sure that there is no water left inside the unit’s
case. Prior to a long break in using the unit, dry its surface and
pack it into a plastic bag, then put it into a box. Store the unit in a low-humidity room. Storing the unit undried results in generation of mold.
www.timberk.com • electric humidifier
7
10. TRANSPORTATION AND STORAGE
Problem Possible cause Remedy
1. When transporting, any possible impacts and movements of the package inside a vehicle must be avoided.
2. Handling symbols on the unit’s package must be strictly observed when transporting and storing it.
3.
Temperature requirements*
Humidity requirements*
Transportation and storage
-30°C to +50°C
15% to 85% (no condensate)
We are researching new technologies and constantly improving the quality of our products. Specifications, design and scope of delivery may be changed without any prior notice.
* Products must be stored in dry, ventilated storages at the temperature not lower than -30°C.
11. TROUBLESHOOTING
In case of emergencies use troubleshooting methods, listed in Table 2. If it is impossible to remedy problems by the listed methods, contact the manufacturer’s service center.
Tabla
Problem Possible cause Remedy
There is no problem. If you need to switch to the intensive mode of operation, press button «Set» and select the necessary steam outflow intensity.
Set maximum capacity. The humidifier’s capacity will go up after a while.
Connect the power cord into the outlet carefully
Poor atomizing (insufficient capacity)
No atomizing
The unit is operating in the minimized mode (low atomizing frequency)
The atomizer is clogged Clean the atomizer.
Temperature of water in the tank is too low
The power cord is poorly connected to the outlet
No atomizing
There is white deposit on objects around the humidifier (salts, separating out from water)
Difference between the current humidity level and hygrometer readings is too big
Steam has an unpleasant odor
Condensate is formed on the upper part of the humidifier and on surrounding objects, when it is operating.
Water appears next to the humidifier, when it is operating.
Water appears next to the humidifier, when it is not operating.
The red water level indicator is on (water in the tank is completely used up)
Lime deposits have formed on the membrane
Properties of the water softening filter have deteriorated
The water used contains large amounts of calcium and magnesium
Dirt has accumulated inside the air vent
The unit operates in places with environmental exposure, for example, it is located by a window
Stale water is used
Remains of stale water or waste have accumulated in the unit’s case or the atomizer
1. High humidification intensity is set.
2. High room humidity and temperature.
1. High humidification intensity is set.
2. The water tank is loosely installed on the unit’s base and there is a gap between them.
3. Lime deposits have formed on the membrane and in grooves for water (in the unit’s base).
The water tank is not leak proof.
Add water into the tank
Clean the humidifier’s membrane with a special brush
Replace the water softening filter.
Use softened water from a domestic filter
Clean the air vent. Humidity may vary even in one room depending on the unit’s location and temperature
Install the unit in places with no environmental exposure
Clean the unit according to the cleaning and maintenance instructions and fill the tank with fresh water
Lower the humidification intensity with the help of the Set button.
1. Lower the humidification intensity with the help of the Set button.
2. Turn on the unit and make sure the water tank is installed correctly and without any gaps with respect to the unit’s base.
3. Clean the unit according to the cleaning and maintenance instructions.
Contact the manufacturer’s authorized service center.
12. UTILIZATIONE
The humidifier’s life is 2 years. At the end of life, the humidifier must be disposed in accordance with regulations, rules and method, effective in the disposal area.
8
www.timberk.com • electric humidifier
СОДЕРЖАНИЕ
1. Важная информация
2. Правила безопасности
3. Технические характеристики
4. Описание прибора
5. Комплектация
6. Наполнение резервуара водой
7. Экплуатация прибора
8. Фильтр картридж для умягчения воды
9. Чистка и обслуживание прибора
10. Гарантийный талон
Уважаемый покупатель!
9 10 11 11 12 12 13 14 14 16
Благодарим Вас за удачный выбор и приобритение увлаж­нителя воздуха ТIMBERK. Он прослужит Вам долго.
Увлажнитель воздуха повышает относительную влажность воздуха в помещении и нормализует микроклимат, помогая избежать пагубных явлений пониженной влажности.
Просим вас внимательно ознакомиться с руководством по эксплуатации перед тем, как вы начнете эксплуатацию из­делия!
1. ВАЖНАЯ ИНФОРМАЦИЯ
Производитель оставляет за собой право без предварительного уве­домления покупателя вносить изменения в конструкцию, комплек­тацию или технологию изготовления изделия с целью улучшения его свойств. В тексте и цифровых обозначениях данного руководства могут быть допущены опечатки.
Если после прочтения руководства у Вас останутся вопросы по рабо­те и эксплуатации прибора, обратитесь к продавцу или в специализи­рованный сервисный центр для получения разъяснений. На изделии присутствует этикетка, на которой указаны все необходимые техниче­ские данные и другая полезная информация о приборе.
Используйте прибор только по назначению, указанному в данном ру­ководстве.
Увлажнитель предназначен для увлажнения воздуха в помещении. Комфортные условия достигаются при относительной влажности воздуха от 40 до 60%. Недостаточная влажность воздуха приводит к высушиванию слизистых оболочек, что в свою очередь является причиной снижения иммунитета, головной боли, растрескивания губ, жжения в глазах, благоприятствует развитию инфекции и заболева­ниям дыхательных путей, вызывает утомление, приводит к повышен­ной усталости глаз и ухудшению концентрации внимания, отрицатель­но влияет на состояние домашних животных и комнатных растений, приводит к усилению пылеобразования, повышению электростатиче­ского заряда синтетических тканей.
www.timberk.com • электрический увлажнитель воздуха
9
Loading...
+ 19 hidden pages