8
In case of emergencies use troubleshooting methods, listed in Table 2.
If it is impossible to remedy problems by the listed methods, contact the
manufacturer’s service center.
11. TROUBLESHOOTING
10. TRANSPORTATION AND STORAGE
1. When transporting, any possible impacts and movements of the
package inside a vehicle must be avoided.
2. Handling symbols on the unit’s package must be strictly observed when
transporting and storing it.
3.
Temperature
requirements*
Humidity
requirements*
Transportation and
storage
-30°C to +50°C
15% to 85%
(no condensate)
We are researching new technologies and constantly improving the quality
of our products. Specifications, design and scope of delivery may be
changed without any prior notice.
* Products must be stored in dry, ventilated storages at the temperature not lower than -30°C.
Tabla
Problem Possible cause Remedy
Poor atomizing (insufficient capacity)
The unit is operating in the minimized
mode (low atomizing frequency)
There is no problem. If you need
to switch to the intensive mode of
operation, press button «Set» and
select the necessary steam outflow
intensity.
The atomizer is clogged Clean the atomizer.
Temperature of water in the tank
is too low
Set maximum capacity. The
humidifier’s capacity will go up after
a while.
No atomizing
The power cord is poorly connected
to the outlet
Connect the power cord into the
outlet carefully
The humidifier’s life is 2 years. At the end of life, the humidifier must be
disposed in accordance with regulations, rules and method, effective in
the disposal area.
12. UTILIZATIONE
Problem Possible cause Remedy
No atomizing
The red water level indicator is on
(water in the tank is completely
used up)
Add water into the tank
There is white deposit on objects
around the humidifier (salts,
separating out from water)
Lime deposits have formed on the
membrane
Clean the humidifier’s membrane with
a special brush
Properties of the water softening filter
have deteriorated
Replace the water softening filter.
The water used contains large
amounts of calcium and magnesium
Use softened water from a domestic
filter
Difference between the current
humidity level and hygrometer
readings is too big
Dirt has accumulated inside the
air vent
Clean the air vent.
Humidity may vary even in one room
depending on the unit’s location and
temperature
The unit operates in places with
environmental exposure, for example,
it is located by a window
Install the unit in places with no
environmental exposure
Steam has an unpleasant odor
Stale water is used
Clean the unit according to the
cleaning and maintenance instructions
and fill the tank with fresh water
Remains of stale water or waste have
accumulated in the unit’s case or
the atomizer
Condensate is formed on the
upper part of the humidifier and
on surrounding objects, when it is
operating.
1. High humidification intensity is set.
2. High room humidity and
temperature.
Lower the humidification intensity with
the help of the Set button.
Water appears next to the humidifier,
when it is operating.
1. High humidification intensity is set.
2. The water tank is loosely installed
on the unit’s base and there is a gap
between them.
3. Lime deposits have formed on the
membrane and in grooves for water
(in the unit’s base).
1. Lower the humidification intensity
with the help of the Set button.
2. Turn on the unit and make sure the
water tank is installed correctly and
without any gaps with respect to the
unit’s base.
3. Clean the unit according to
the cleaning and maintenance
instructions.
Water appears next to the humidifier,
when it is not operating.
The water tank is not leak proof.
Contact the manufacturer’s authorized
service center.