Timberk TCH A3 1000, TCH A3 1500, TCH A3 2000 Instruction Manual

Outlook of devices, aslo colour scores can be revised without any special advance notices.
Производитель вправе менять внешний вид прибора и цветовую гамму при­бора без специального уведомления .
Instruction manual
Руководство по эксплуатации
Инфракрасный электрический обогреватель
Модели/Models:
TCH A3 1000 TCH A3 1500 TCH A3 2000
Electric ceiling heater (infrared heater)
www.timberk.com • electric ceiling heater
2
Dear customer!
Thank you for good choice and purchase of the Timberk infrared heater. It will serve long.
The Timberk electric infrared heater is designed for general, additional, or local heating of living and production premises of all types with ceiling height from 2.5 to 3.5 meters. The heater can be installed only on the ceiling or ceiling structural elements, or on a wall, where it can be connected to ~220 V, 50 Hz single-phase power supply. This heating appliance is efficient and economic in use thanks to minimum losses of electric power.
Please carefully read the Operation Manual before using the infrared heater. This Operation Manual contains the important information on your safety,
as well as some recommendations on proper use of the appliance and its maintenance.
Keep the Operation Manual along with the warranty certificate, sales receipt, and, if possible, cardboard package and packing material.
The purchased infrared may somewhat differ from one described in the Manual, but this does not affect the methods of use and operation.
During use of the infrared heater, it is necessary to observe some precautions. Improper operation with disregard of precautions may result in infliction of harm to health of the user and other people, as well as in infliction of damage to their property.
1. Read all instructions before using the heater.
2. Temperature of radiating boards during operation of the heater may reach 340 °C. To avoid burns, do not touch the appliance surface by hand and other body parts. It is also necessary to exclude the possibility of touching the heater radiating boards by a person (including accidental) via proper instructions and allocation of the heater in an inaccessible place.
3. The heater should be placed far from flammable and easily deformable objects.
4. The power cord and other objects should not contact hot surfaces of the heater.
5. Make sure that the heater body and its radiating boards get cold before demounting and placing the heater to the package for long storage.
6 During demounting of the heater or its movement, take special precautions to exclude hits of the appliance and its falling.
7. When the heater is not used for a long time, keep it in dry cool place in the factory cardboard package.
8. DO NOT COVER the heater. Do not dry clothes and any other fabrics/ materials on the appliance. This may lead to its overheating, breakdown, or infliction of a significant damage to you and/or your property.
IMPORTANT!
The important precautions and instructions contained in the manual do not include all possible modes and situations which can occur. It should be realized that common sense, care and accuracy are the factors which cannot be «inbuilt» in any device. These factors shall be taken into account by a person being interested in the proper operation of the device. The manufacturer is not liable if damage to the device or its separate parts is caused during transportation, due to incorrect installation, voltage fluctuations, and also if any part of the device was changed or modified
1. IMPORTANT INFORMATION
2. PRECAUTIONS
IMPORTANT!
The manufacturer considers this type of failure a non­guaranteed event.
9. The heater should be connected to the electric mains equipped with an automatic circuit breaker.
10. Never connect the heater to the electric mains, if its surface is moist (wet).
11. Never try to repair the heater yourself. This may inflict harm to your health and affect the warranty service of the appliance.
www.timberk.com • electric ceiling heater
3
3. WORKING PARAMETERS
12. It is prohibited to use the heater in rooms with explosive, dusty, or corrosive environment.
13. Exclude operation of the heater without grounding.
14. It is prohibited to switch on and use the heater with removed cover.
15. It is prohibited to install and use the heater in bathrooms, showers, or near swimming pools, where water jets and drops may directly get onto the appliance surface, when it is switched on.
16. It is prohibited to use the heater in dusty rooms and during redecoration.
17. It is prohibited to touch the heater radiating boards.
18. Use the heater only as described in this Manual. Any other use not recommended by the manufacturer may lead to fire, electric shock, or injuries of people.
19. Never clean the heater, when it is connected to the electric mains, and do not wipe the heater radiating boards with flammable liquids during its operation.
20. For normal operation of the heater, the mains voltage should be sufficient and the mains specifications should strictly correspond to the technical parameters indicated on the appliance body. If necessary, clarify the specifications of your mains from the electricity supplier.
21. Install and operate the heater on the ceiling constructions and on the wall. At that, thermal resistance of the ceiling coating material should be at least 80
0
C.
22. It is prohibited to install the appliance in immediate proximity to an electric socket. This may result in its overheating causing an emergency situation.
23. The appliance is not designed for use by people (including children) with limited physical, sensory, or mental capabilities and having insufficient experience/knowledge, if they are not supervised and instructed on use of the device by a person responsible for their safety. It is necessary to watch that children do not play with the heater.
24. There can be sticked an advert stickers on the heating plates. It should be removed from the surface before first start of the device.
25. There is a warning sticker on the reverse side of the device. It is strongly do not recommended to remove it. You can do this, only if you want to attach the remote control block. (Remote Control Block is not included in the standard set of heater; you can buy it separately).
Operation principle
The infrared heater is an appliance with an open electric heating element that gives heat when heated in the environment by generating directional infrared radiation. Radiant energy absorbed by the surrounding surfaces and turning into thermal energy heats them . The temperature on the surface of objects may be different depending on their properties termoabsorbtsionnyh (numbers surface material) , the angle of incidence of infrared rays , the shape and surface area. Surface is also given to some of the heat the air, while heated air rising to the ceiling, gradually cools down, while at the head of a standing person on the air temperature is 1-2 ° C below the temperature of the floor.
Main features
1. Significant economic effect as compared to convectional heating, where heat is significantly consumed for heating of unused roof space (first, air is heated throughout the room volume, and then air heats objects and surfaces in the room).
2. Capability of local heating only for those areas in the room, where it is necessary, without heating of the whole room volume.
3. Low air temperature in the room at comfortable temperature on surfaces of objects, floor, and walls creates the freshness effect air is not dried up.
4. Low convection (thermal movement of air volumes) reduces amount of dust kicked up from the floor.
5. Absence of the burnt air effect contrary to heaters with high temperature of the work surface.
6. You can buy & install additionally the following: Block of Remote Control together with Remote Control Handheld. Remote Control Block can switch on/off the heater and also use timer settings. Using Remote Control, you will get more options than simple ceiling heater can provide like base function set.
Area of application
Infrared heaters are designed for general, additional, and local heating of industrial, production, utility, and similar rooms (flats, offices, trade enterprises, exercise rooms, educational institutions, public catering enterprises, storage facilities, hangars, agricultural facilities, etc.).
When these heaters are used in day-care services they can be used only for additional heating.
www.timberk.com • electric ceiling heater
4
Minimum distances from the heater to other surfaces according to Fig. 1 are given in Table 2.
Table 2
Minimum distances from heater to other surfaces
WARNING!
At long standing in the heated area, the distance from the heater radiating boards to a person or an animal at indoor air temperature below +11 °C should be at least
1.8 m.
IMPORTANT!
The manufacturer reserves the right to change the set-list of the device (including liquid and powder components) for different supplies without prior notice. The changes either in no way influence the basic technical parameters of the device or may improve them, and also not violate the legislation or quality standards of the countries of manufacture, transit and selling.
The changes in the set-list may result in changing of the weight and dimensions of the device, but not more than by +\- 5-20% (depending on the product category)
NOTE:
Heated area in the table is indicated for reference, since it depends both on the heater power, and on room type, ceiling height, wall/ ceiling materials, number and area of glazing, presence of doors, etc.
Fig.1
Technical specifications
Technical specifications of the TCH A3 infrared heater.
For more detailed description of technical parameters and specifications please refer to our website www.timberk.com or ask from the official dealers of TIMBERK.
Parameter
Meas.
units
Item
TCH A3 1000 TCH A3 1500 TCH A3 2000
Nominal power consumption
W 1000 1500 2000
Rated current
A 4,5 6,8 9,1
Rated voltage
V/Hz ~220/50 ~220/50 ~220/50
Water protection class
IP20 IP20 IP20
Electric protection class
Class I Class I Class I
Recommended installation
height
m 2,5 2,7 3,5
Weight
kg 2,0 2,9 3,6
Dimensions
mm
50x935x110 50x1360x110 50x1785x110
Dimensions, mm
Article number
TCH A3 1000 TCH A3 1500 TCH A3 2000
A 78 78 78
B 150 150 150
C 600 600 600
D 2500 2700 3500
E* 700 700 700
* At long standing in the heated area
www.timberk.com • electric ceiling heater
5
1. Heater body
2. Protective grille
3. Heating element
4. Cover
1. Infrared heater - 1 pc
2. Set of fasteners - 1 pc
3. Operation manual - 1 pc
4. Warranty certificate - 1 pc
4. INFRARED HEATER DESCRIPTION
5. DELIVERY SET
Fig.2
1. Open the factory package and carefully remove the heater from it.
2. Take the set of fasteners.
3. Select the heater installation place on the ceiling or ceiling structural elements with observation of minimum distances from objects and minimum distance from the floor.
4. Install the brackets at distance from each other, securing them using a chain or fasteners (fig. 3).
5. Suspend the heater on the brackets according to Fig. 3, first securing on edge, then another. Make sure that screws are tightened firmly.
Infrared heater mounting
6. INSTALLATION
NOTE:
To improve the product quality, the design and technical specifications of the infrared heater, as well as its delivery set can be modified by the manufacturer without preliminary notification.
WARNING!
Mounting of the infrared heater and its connection to the electric mains should be carried out only by qualified specialists according to the Electrical Installation Regulations and Power System Safety Standards.
Fig.3
1
2
4
3
www.timberk.com • electric ceiling heater
6
Connection to electric mains
1. The heater is designed for connection to the single-phase ~220 V, 50Hz electric mains equipped with a grounding loop.
2. Before connection, make sure that specifications of the electric mains at the connection point meet the parameters indicated on the appliance nameplate.
3. The heater should be connected to the electric mains using a cable with wire section at least 1.5 mm
2
. The electric mains should be equipped with
an automatic circuit breaker with rated current not less than 16A.
4. For connection of the heater to the electric mains, it is necessary to do the following:
remove the cover from the heater.
cut a hole in the rubber seal.
insert the electric cable to the heater.
tightly fix the bare ends of the electric cable in the junction block of the
heater with screws in strict correspondence with marking on the block.
reinstall the cover.
1. Before switching the heater, it is necessary to thoroughly wipe the surface of the radiating boards first with a soft rag moistened in alcohol and then with a dry rag in order to exclude appearance of burnt spots.
2. After switching and reaching the working mode, the appliance starts to radiate infrared beams and heat the surrounding objects/bodies.
3. To exclude unpleasant burnt odor, it is recommended to keep the heater clean preventing accumulation of dust on it.
1. During operation, it is necessary to periodically (once a year) check the electric cable contacts and terminal connectors for good tightening.
2. If the body becomes dirty, wipe off dust with a towelette. Radiating boards should be wiped in cold condition with alcohol.
7. OPERATION
8. MAINTENANCE
NOTE:
1. Depending on material and design of ceiling structural elements, the heater is secured onto appropriate fasteners chosen on basis of the strength condition. Strength of the ceiling or structural elements, to which the heater is secured, should be sufficient to endure 5-fold weight of the heater.
2. The heater can be installed on the wall and mounted on the height not less than 1.8 from the floor. Also it is obligatory to be installed an additional protection in order to avoid the contact with heating plates.
NOTE:
The instruction manual for remote control block is not included in the scope of delivery. Should be bought separately.
NOTE:
Discoloration of paint on the heater body wall directed to the ceiling during operation is not a defect. Changing of colour for heating plates is not defect.
WARNING!
After installation of the heater and before switching for the first time, it is necessary to wipe the radiating board with alcohol. After that, it is PROHIBITED to touch the radiating board.
WARNING!
Slight crackles may be heard during operation at the moment of heating or cooling, which disappear, when the heater reaches the working mode.
Loading...
+ 14 hidden pages