Thorens TEM 3200 User Manual [de]

0 (0)
TEM 3200
User Manual Bedienungsanleitung
© 2006 Thorens Export Company Ltd, all rights reserved.
Under the copyright laws, this manual may not be copied, in whole or in part, without the consent of Thorens.
The Thorens logo is a trademark of Thorens Holding Ltd. Use for commercial purposes without the prior consent of Thorens may constitude trademark infringement.
Thorens is not responsible for printing or clerical errors.
© 2006 Thorens Export Company AG, alle Rechte vorbehalten.
Bedienungsanleitungen und Handbücher sind urhebrrechtlich geschützt. Das Kopieren, Vervielfältigen, Übersetzen oder Umsetzen in irgendein elektronisches Medium oder maschinell lesbare Form im Ganzen oder in Teilen ohne vorherige Genehmigung von Thorens ist nicht gestattet.
Thorens übernimmt keine Gewähr für die Richtigkeit des Inhalts dieser Bedienungsanleitung.
Thorens Export Company AG, Im Huebel 1, CH-4304 Giebenach, Switzerland Tel: +41 (0) 61 813 03 36, Fax: +41 (0) 61 813 03 39, E-Mail: info@thorens.com www.thorens.com
User Manual Bedienungsanleitung
English........................................................................4
Deutsch.....................................................................15
3
English
Congratulations on purchasing your Thorens TEM 3200!
Your TEM 3200 features the latest generation of power amplifier de sign. Conventional amplifiers are built with complementary transis­tors of different conductivity (n-type and p-type). Instead of that the Thorens TEM 3200 employs a perfect symmetrical circuitry which uses extremely powerful n-type MOSFETs only. Voltage amplification is done by six matched tubes in the input stage. Thereby the TEM 3200 unites the benefits of tube and transistor amplifiers in a perfect and utterly new way. It sounds like a tube with the power of a huge transistor amplifier.
The whole product is “Made in Germany”, which guarantees highest sonic quality combined with a long lifespan.
Please take a few minutes to read through this manual. It contains important information that will help you to avoid damages and to ensure proper wiring with the rest of your system.
Contents
Safety instructions.......................................................................... 5
Unpacking and installation.............................................................. 6
Connecting the TEM 3200.............................................................. 7
Operating.....................................................................................10
-
Maintenance................................................................................. 11
Specifications...............................................................................12
Trouble shooting............................................................................13
Customer support........................................................................14
4
Safety instructions
PLEASE READ THIS PAGE BEFORE OPERATING YOUR UNIT!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION: DANGER D’ELECTROCUTION. NE PAS OUVRIR.
CAUTION
To reduce risk of electric shock, do not remove the cover (or back). No user­serviceable parts inside.
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert you to the presence of uninsulated ‘dangerous voltage’ within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert you to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
FOR YOUR SAFETY: Units shipped to the U.S.A. and Canada are designed to operate on 115-120 V AC
only. Safety precaution with use of a polarized AC plug. However, some products may be
supplied with a non-polarized plug. CAUTION: TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS (POLARIZED) PLUG
WITH AN EXTENSION CORD RECEPTABLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
WARNING
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
This product was tested and complies with all the require ments for the CE Mark.
-
IMPORTANT: DISPOSAL OF WASTE EQUIPMENT BY USERS IN PRIVATE HOUSEHOLDS IN THE EUROPEAN UNION
This symbol on the product or on its packaging indicates that this product must not be disposed off with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
5
Unpacking and installation
Please unpack your Thorens Power Amplifier TEM 3200 carefully. We suggest that you save the cardboard and packing materials for later use.
The TEM 3200 is delivered in two packages, each containing one amplifier. Although both units show minor differences on the outside (different orientation of ventilation slots on top), there is no functional distinction inside: You may arrange them as you please.
Scope of supply: (each unit)
Please place your Thorens TEM 3200 on a firm, solid and level sur­face. It is important and vital to allow at least four inches of space behind and above the unit for adequate ventilation.
Do not obstruct the ventilation slots on the top (or on the bottom) of the unit or place objects directly over them.
Never expose the unit to either of the following conditions:
Locations near air ducts, radiators or other sources of heat or direct exposure to sunlight
Extremely cold locations
Locations subject to extensive dust, moisture, mechanical vibration, shock or poor ventilation
Locations very close to turntables to avoid hum pick-up
1 x Thorens TEM 3200 1 x Country-specific power cord 1 x Adapter for RCA
6
Connecting the TEM 3200
A
B
+
1 2 3 4
The TEM 3200 is a power amplifier designed to drive any passive HiFi­loudspeaker. To connect it to your HiFi-equipment you additionally need a preamplifier, such as the Thorens TEP 3800* to control inputs and volume.
For safe amplifier operation, please use only speakers with impedance of more than 2 ohms! We recommend speakers with impedance of more than 4 ohms.
Switch off all units before wiring. Disobeying may cause damage to the speakers.
Rear panel connectors
* available 2006
7
Audio input
As the electric circuit structure of the TEM 3200 is intrinsically sym metrical there is only a balanced input jack. Connect this jack to the BALANCED PRE-OUTPUT jacks of your pre-amplifier. Make sure that the plug sits tight in the jack and keep in mind the pin configura­tion: (see next page)
-
Connecting the TEM 3200
Pin configuration:
Do not use a cord with different configuration!
To unplug the balanced XLR cord from the input jack, push the tab above the jack and unplug it.
With the RCA adapter shipped with this unit you can also use unbal­anced RCA cords. The signal balancing is performed inside the TEM 3200 by an excellent signal transformer.
Speaker outputs
The TEM 3200 uses the outstanding loudspeaker terminals of WBT, Germany. These have been proven to provide perfect contact over many years in millions of sets.
Connect the positive input jack of your loudspeaker (usually marked red) with one of the red marked output jacks on the rear panel of the TEM 3200. You can choose either of them. Repeat these instructions for the negative jack.
You can insert the bare loudspeaker cable by loosening the knob, inserting the wire from the side and then tightening the knob again. You can do the same with spades at the ends of your cables or use banana plugs (they can simply be plugged in from the rear).
Pin 1: Ground Pin 2: Positive (non-inverted) signal Pin 3: Negative (inverted) signal
Always assure that the cables are fixed tightly and do not al low the wire to protrude and touch other terminals or wires!
This amplifier is floating at the output jacks.
Never ground
Do not connect active subwoofers to the speaker outputs and do never short-circuit the output jacks or the loudspeaker wires when connected. The unit will be damaged severely!
either one of the jacks.
8
-
Connecting the TEM 3200
The TEM 3200 offers the possibility of connecting the speakers in bi­wiring manner. Please ask your dealer about this issue and if bi-wiring holds benefits for your speakers.
AC power supply
Plug the power cord into the appropriate AC outlet on the wall or on a high-power extension cord. Do not plug it into the AC outlets of other equipment components or extension cords that can not endure the power consumption of the TEM 3200.
Do not pull out the power cord when the amplifier is switched on. The unit might be damaged.
Required line voltage
U.S.A. and Canada...........................................................115-120 V
Europe, Australia and Asia................................................220-240 V
Japan...................................................................................100 V
Power consumption
See Specifications or type plate at the rear of the unit.
To prevent electrical shock do not use extension cords, receptacles or other outlets unless the contacts can be fully inserted.
9
Loading...
+ 19 hidden pages