Thor DVB ASI Over IP Gateway User Manual

Bi-Directional Gateway
User’s manual
H-1ASI-IP-B
Catalog
1111
SAFETY INSTRUCTION ············································································································································· 1
2222
System structure and principle ····························································································································· 2
2.1
System structure ······································································································································ 2
2.2
Working principle ····································································································································· 2
3333
Specifications ···································································································································································· 3
3.1
ASI Interface············································································································································· 3
3.2
Network port ·············································································································································· 3
3.3
Power failure auto save ·························································································································· 4
3.4
Power ························································································································································ 4
3.5
Working environment ······························································································································ 4
3.6
Mechanics················································································································································· 4
3.7
Weight ······················································································································································· 5
4444
Equipment connection ··················································································································································· 5
4.1
Front panel and keybord ························································································································ 5
4.1.1
Front panel ······································································································································· 5
4.2
Front panel ··············································································································································· 5
4.3
Rear panel ················································································································································ 6
5555
Operations ········································································································································································· 6
5.1
Keybord ····················································································································································· 6
5.2
Menu ·························································································································································· 7
5.2.1
Lock status ······································································································································· 7
5.2.2
5.2.3
Main Menu········································································································································ 7 Basic parameters ···························································································································· 7
5.2.3.1
5.2.3.2
5.2.3.3
5.2.4
5.2.5
5.2.6
5.2.7
5.2.8
5.2.9
6666
SYSTEM FAILURE OR TROUBLE SHOOTING ······························································································ 12
6.1
6.2
6.2.1
6.2.2
6.2.3
Output ······································································································································· 8 Input ·········································································································································· 9
Local ········································································································································· 9 Network setting ······························································································································ 10 Save current settings ···················································································································· 10 Load settings·································································································································· 11 Version No. ····································································································································· 11 Language settingEnglish ······································································································ 11 Error info ········································································································································· 11
INDICATOR status ································································································································ 12
Trouble shooting ···································································································································· 12
POWER” INDICATOR OFF ········································································································· 12 “ERROR” ON (RED) ····················································································································· 12 AS1 and IP indicator ON ·············································································································· 12
7777
NMS Operation ···························································································································································· 13
1
1 SAFETY INSTRUCTION
11
Read manual carefully before use.
Do not open the case and touch internal components for safety and warranty
Pull out power plug in case of long time standby .Do not use faulty power plug or
power supply to avoid fire or electric shock.
Do not touch power supply with wet hands.
Handle with care when pulling out power plug, no touch with the wire.
No flammable or liquid allowed into device.
Do not install Encoder in hot area or strong sunshine or dusty place.
Shock-proof is a must.
Room with good ventilation is required.
Keep original packing material for future possible transportation.
1111
DATA
ASI OUT
CPU
LED Keybo
Network
LCD
ASI IN
2
2 System structure and principle
22
2.1
2.1 System structure
2.12.1
IP adaptor structure as below:
Data proce ss
2.2
2.2 Working principle
2.22.2
The H-1ASI-IP-B unit consists of an ASI input/output module, an Ethernet IP output/input module, and a CPU module. An ASI Transport Stream that is input into the ASI module is encapsulated by the CPU and output by the Ethernet module. The opposite process takes place at the receiving end.
.
.
. .
2222
3333
3
3 Specifications
33
3.1
3.1 ASI Interface
3.13.1
Input port 2 routs DVB ASI port
ConnectorBNC
Impedance75Ω
TS standardISO13818-1
Input effective bit ratemax 214Mbpseach route
TS packet format188/204bytesauto recognition
TS input mode CBR /BURST/VBR
3.2
3.2 Network port
3.23.2
There are two network ports on the H-1ASI-IP-B.
Data Port: The RJ-45 Port labeled “Data” is the transport port for the
encapsulated ASI stream. This port carries the primary IP address for the device, and is the only port that needs to be connected for the device to function. It is important to note that the Data port IP address does not support the “ping” function. It is also important to note that when making changes to the IP configurations either via front panel or NMS it is important to use the “Save Config” option on the top menu when on the front panel, or click the “Save Config” button in the software when using NMS.
Ethernet Port: This port is for network management via the Network
Management Software. It is not essential for this port to be connected for proper functioning of the device. However the Network Management Software is the most effective method for setting the devices IP address. If problems arise while attempting to set the device IP with the front panel please use the network management software.
Loading...