INSTALLATION INSTRUCTIONS
for "Flood-Seal"® Street Light Fuse Kits
SLK 22 M, SLK 22 M 10 CAB, SLK 102 M, SLK 1010 M, SLK 22-60 M,
SLK 1010-60 M, SLK 102-60 M, SDK 22 M, SDK 102 M, SDK 1010 M
CATALOG
NUMBER
AL/CU
WIRE
SIZE
RUN
TAP
SLK 22 M
SLK 22-60 M
SDK 22 M
#2 to #14 1/0 to #2 1/0 to #2
#2 to #14 #2 to #14
For Copper and Aluminum Conductors Rated for 600 volts
SLK Kits contain:
1 line-end assembly
1 load-end assembly
Note: Fuse not included. Catalog numbers with sufx -60 M
require a 60 Amp fuse.
SDK Kits include the above items plus a connecting link to
be used in place of a fuse.
CAUTION
Identify line- and load- side wires and match the
housing body parts before installing. All associated
wires and working area must be de-energized.
SLK 102 M
SLK 102-60 M
SDK 102 M
2 FSS 20 "Flood-Seal"
SLK 1010 M
SLK 1010-60 M
SDK 1010 M
1/0 to #2
®
Rockets
1 packet of Silicone Grease
WARNING
Danger of Electric Shock! Installation of this product
must be performed by trained installers in accordance
with all applicable local, state and national electrical
codes, installation standards and safety rules.
Strip the insulation from
4 5
the cable end baring
3/4” of conductor.
3/4”
Mate the rocket to the line-end assembly for a
6
watertight seal.
Insert line-end cable
into the line-end
assembly and torque
the set screw to 25
in-lbs.
Complete Steps 1 through 6 for both the Line End and
Load End housing.
Select the correct cut off
1
ring on line-end housing for
cable being used. Cut off
the end housing at the tip of
the arrow, leaving the
14 to 8 (S/L)
8 to 4 *(.24-.38)
4 to 10 *(.380-.540)
* DECIMAL RANGE
correct cable size showing.
Wipe the cable clean. Pencil the
2 3
end of cable insulation for ease
of installation. Apply silicone
grease to the end of the cable
and to the cut opening of the
line-end housing.
Insert cable until it
extends 2” to 3”
beyond the
housing.
2”-3”
Limited Warranty Applies. Refer to:
www.tnb.com/ecpwarranty for full warranty terms.
Thomas & Betts Corporation
Memphis, Tennessee
© 2012 Thomas & Betts. All Rights Reserved.
14 8
8 4
4 10
LINE
END
www.tnb.com
Insert the appropriate 13/32” (max. 600 Volt) cartridge
7
fuse in the load-end assembly. (DO NOT use glass
body fuse). Grease sealing area of load-end. DO NOT
grease sealing rings on line-end.
Grease this area of load-end
FUSE
Mate the line-end housings to make the electrical
8
connection.
LINE-END LOAD-END
0510060 A