DB9F Adapter (ADP-000025-R) and DB9M Adapter (ADP-000019-R)4
•
CD Product Manual
1 For VelocityDVI-3, Qty = 1 each. For VelocityDVI-33, Qty = 3 each
2 For VelocityDVI-6, Qty = 1 each. For VelocityDVI-63, Qty = 3 each
3
With A/V+ and A/N+ models
4
With A/V+ models only
1.2. Product Overview
MRTS Technology 6.25 Gbps. allows for Full Frame Rate Transmission of uncompressed DVI.
Powered by Thinklogical’s® cutting edge, patent-pending MRTS (Multi Rate Transmission System)
Technology, our DVI Extension Systems transport every frame of a DVI video stream seamlessly with no
compression or dropped frames. In addition, all high speed peripherals function with no latency.
Incorporating standard SFP+ transceivers, the system uses multi-mode fiber optic cable to
placement of a digital monitor or projector up to 1000 meters (3280 feet) away from the controlling
computer without loss of resolution. Thinklogical® also offers optics that
cables to allow
the placement of video devices up to 10, 40 or 80 km (6.2/24.8/49.7 miles) away from
use single-mode fiber optic
the controlling computer without loss of resolution. Installation is plug-and-play and no adjustments
are necessary.
Each VEL-3 (single-link) and VEL-6 (dual-link) system consists of one transmitter per chassis
and one receiver per chassis. The rack-mountable VEL-33 system (single-link) and the rackmountable VEL-63 system (dual-link) each feature three transmitters per chassis and three
receivers per chassis.
All models support Data Display Channel (DDC), with a variety of modes to
meet each unique requirement. All models are connected by fiber optic cable(s), the count of which
varies depending upon the DDC mode to provide communications to and from the transmitter. The
transmitter unit connects to the CPU with supplied DVI-D cables (and audio, serial & network cables
in A/V+ and A/N+ models). The receiver unit provides an interface to the monitor(s) (and audio, serial
& network devices in A/V+ and A/N+ models).
Each Transmitter (TX) features a video input and local video output which can be used for DDC
modification and for displaying video at the source. The TX also has fiber connectors used for
transferring video and data to the Receiver. (For an
Automatic Fail-Over option
, see
on page 47 for more details.) Status LEDS and DDC Mode buttons are provided for system
configuration.
Each Receiver (RX) features two video outputs. DVI to DisplayDDC is the primary output and DVI to Display is an auxiliary output. The RX has fiber connectors used for transferring data to the TX and
for receiving video and data from the TX. Status LEDS and DDC Mode buttons are provided for
system configuration.
permit the
Appendix D,
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
VOP-S05 VELOCITY 3 AV+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM,
VOP-S11 VELOCITY 3 AV+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM,
VELOCITY 3 optics option for TX or RX, SINGLEMODE, DUAL FIBERS, 10KM
VELOCITY 6 optics option for TX or RX, SINGLE MODE, 3 FIBERS, 10KM
VELOCITY 3 DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SINGLE MODE, SC/APC
VELOCITY 3 DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT, DDC,
SINGLE MODE, SC/APC
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI OUTPUT,
DDC, SINGLE MODE, SC/APC
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI OUTPUT,
DDC, SINGLE MODE, SC/APC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, LC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, LC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, SC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, SC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, ST
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, ST
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, LC
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, LC
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, SC
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, SC
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, ST
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, ST
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, SC/APC
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, SC/APC
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, NEUTRIK LC
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, NEUTRIK LC
SC/APC
NEUTRIK LC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
6
VEL-AV0M03-NKTXVELOCITY 3
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI MODE, TX, NEUTRIK
VOP-M04VELOCITY 3 AV+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M, or 350M
or 1000M, LC or NEUTIK LC
VOP-M01VELOCITY 3 AV+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M or 350M or
1000M, SC or ST
VEL-AN0S03-SCRX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, SC/APC
VEL-AN0S03-SCTX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, SC/APC
VEL-AN0S03-NKRX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, NEUTRIK LC
VEL-AN0S03-NKTX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, NEUTRIK LC
VOP-S05VELOCITY 3 A/N+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM,
SC/APC
VOP-S11VELOCITY 3 A/N+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM,
NEUTRIK LC
VEL-AN0M03-LCRXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
VEL-AN0M03-LCTXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
VEL-AN0M03-SCRXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
VEL-AN0M03-SCTXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
VEL-AN0M03-STRXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
VEL-AN0M03-STTXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
VEL-AN0M03-NKRXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
VEL-AN0M03-NKTXVELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, NEUTRIK
VOP-M04VELOCITY 3 A/N+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M, or 350M
or 1000M, LC or NEUTIK LC
VOP-M01VELOCITY 3 A/N+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M or 350M
or 1000M, SC or ST
VEL-000M06-LCRX
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI OUTPUT,
DDC, MULTI-MODE, RX, LC
VEL-000M06-LCTX
VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-MODE,
TX, LC
VEL-000M06-SCRX
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI OUTPUT,
DDC, MULTI-MODE, RX, SC
VEL-000M06-SCTX
VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-MODE,
TX, SC
VEL-000M06-STRX
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI OUTPUT,
DDC, MULTI-MODE, RX, ST
VEL-000M06-STTX
VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-MODE,
TX, ST
VEL-000M63-LCRX
3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI
OUTPUT, DDC, MULTI-MODE, RX, LC
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
7
VEL-000M63-LCTX
3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-
MODE, TX, LC
VEL-000M63-SCRX
3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI
OUTPUT, DDC, MULTI-MODE, RX, SC
VEL-000M63-SCTX
3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-
MODE, TX, SC
VEL-000M63-STRX
3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI
OUTPUT, DDC, MULTI-MODE, RX, ST
VEL-000M63-STTX
3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-
MODE, TX, ST
VEL-AV0S06-SCRX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI
OUTPUT, DDC, SERIAL, AUDIO, SINGLE MODE, RX, SC/APC
VEL-AV0S06-SCTX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI
PORT, DDC, SERIAL, AUDIO, SINGLE MODE, TX, SC/APC
VEL-AV0S06-NKRX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI
OUTPUT, DDC, SERIAL, AUDIO, SINGLE MODE, RX, NEUTRIK LC
VEL-AV0S06-NKTX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI
PORT, DDC, SERIAL, AUDIO, SINGLE MODE, TX, NEUTRIK LC
VOP-S08 VELOCITY 6 AV+ optics option for TX or RX, SINGLE MODE, 3 FIBERS, 10KM, SC/APC
VOP-S12 VELOCITY 6 AV+ optics option for TX or RX, SINGLE MODE, 3 FIBERS, 10KM, NEURTIK
LC/APC
VEL-AV0M06-LCRXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
VEL-AV0M06-LCTXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
VEL-AV0M06-SCRXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
VEL-AV0M06-SCTXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
VEL-AV0M06-STRXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
VEL-AV0M06-STTXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
VEL-AV0M06-NKRXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
VEL-AV0M06-NKTXVELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, NEUTRIK
VOP-M05VELOCITY 6 AV+ optics option for TX or RX, MULTIMODE, 3 FIBERS, 50M, or 350M or
1000M, LC or NEUTRIK LC
VOP-M02VELOCITY 6 AV+ optics option for TX or RX, MULTIMODE, 3 FIBERS, 50M or 350M or
1000M, SC or ST
VEL-AN0S06-SCRX
VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI
VOP-S08 VELOCITY 6 A/N+ optics option for TX or RX, SINGLE-MODE, 3 FIBERS, 10KM, SC/APC
VOP-S12 VELOCITY 6 A/N+ optics option for TX or RX, SINGLE-MODE, 3 FIBERS, 10KM, NEURTIK
LC/APC
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
8
VEL-AN0M06-LCRXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
VEL-AN0M06-LCTXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
VEL-AN0M06-SCRXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
VEL-AN0M06-SCTXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
VEL-AN0M06-STRXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
VEL-AN0M06-STTXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
VEL-AN0M06-NKRXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
VEL-AN0M06-NKTXVELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, NEUTRIK
VOP-M05VELOCITY 6 A/N+ optics option for TX or RX, MULTI-MODE, 3 FIBERS, 50M, or 350M or
1000M, LC or NEUTRIK LC
VOP-M02VELOCITY 6 A/N+ optics option for TX or RX, MULTI-MODE, 3 FIBERS, 50M or 350M or
1000M, SC or ST
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
9
1.4. Laser Information
The DVI Extender models
Velocity-3, -6, -33
2. System Features
and
-63
are designed and identified as
Class 1 LASER products.
2.1. General System Features
Thinklogical’s VelocityDVI Extender Systems® are designed for high resolution video extension
applications, such as remote projection centers, theaters and assembly halls, and for secure
computer installations. The ability to remotely locate the CPU away from the monitor allows more control
of your computer environment. It is now possible to position your monitor or projector in any setting from
office to lecture hall to boardroom while keeping the computer secure in a remote, controlled location.
Each DVI Extender system includes the following features:
•
Supports one Single-Link (System-3) or one Dual-Link (System-6) video signal.
•
Supports three Single-Link (System-33) or three Dual-Link (System-63) video signals.
•
DDC2B compliant
•
Extends DVI up to 1000 meters (3280 feet) using OM4 multi-mode fiber
•
Signal transmission via fiber optic cable; no RF interference
•
Flawless image quality with no frame dropping
•
Class 1 laser product
•
Simple plug and play
•
Small form factor
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
10
2.2. Basic operation
The system transmits video and data information from the Transmitter to the Receiver through fiber L1. The
data return path from the Receiver to the Transmitter is fiber L2.
VelocityDVI Extender Overview
2.3 Single Fiber operation, System-3
The unit will operate with a single fiber from the TX to the RX. In this mode of operation the TX can
transmit video and status LED information to the RX. The RX cannot send any information to the TX. In
this mode the RX buttons are inoperative. Also, DDC information can only be gathered from the TX local
port or the Thinklogical default EDID table.
2.4 Dual Fiber Operation, System-3
In this mode video information is transmitted from the TX to the RX over fiber L1. Fiber L2 is used as a
data return path from the RX to the TX. Providing a back channel from the RX to the TX allows the RX to
modify DDC configuration via the Acquire and Select buttons and allows the RX to send DDC information
to the TX. DDC information exchange allows the PC to gather information about the connected monitor to
determine the display properties.
System-6 operates in Dual-fiber or Triple-fiber operation. In dual-fiber operation, fibers L1 and L3 are used
to transmit data and video from the TX to the RX and in three-fiber mode, fiber L2 transmits data from the
RX back to the TX.
2.5 Fiber Operation, System-6
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
11
2. 6 Technical Specifications (Systems-3, -6, -33 and -63)
6 watts per unit (Vel-3, Vel-6)
20 watts per unit (Vel-33, Vel-63)
With AV+ models only:
DB9M to RJ45 (ADP-000019-R)
DB9F to RJ45 (ADP-000025-R)
CBL000009-002MR Single-link DVI-D Male to Male, 2 meters
1 each, Vel-3 3 each, Vel-33
CBL000023-002MR Dual-link DVI-D Male to Male, 2 meters
1 each, Vel-6 3 each, Vel-63
Compliance Approvals for US, Canada, and European Union
Warranty
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
12 months from date of shipment.
Extended warranties available at time of purchase.
2 0 1 3
Page
12
2.7 Velocity Unbalanced Audio Specifications
3. Installing DVI Extenders
All physical connections to these products use industry-standard connectors.
It is recommended that you securely mount each VelocityDVI chassis before installing the
cabling and power sources.
Appendix A: Installation Overview on pages 39-44
Appendix B: DVI Extender Mounting on page 45
Appendix C: RJ-45 Adapter Pin-outs on page 46
Please refer to the following appendices at the back of this manual:
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
13
3 . 1 AC Power
Two wall pack AC/DC adapters (PWR-000022-R) are included with the VelocityDVI-3 and VelocityDVI-6
models. The AC wall pack has a universal power rating of 100-240VAC, 50-60Hz and also has
interchangeable wall plug adapters for various international AC power receptacles (below).
+5VDC
Continuous Short Circuit Protection
Over Voltage Protection
Conductive EMI Meets CISPR/FCC Class B high efficiency, 75% Typical
International Receptacle Adapters
International Receptacle Adapters for the PWR-000022-R +5VDC Power Supply
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
14
3.2 The VelocityDVI-3, -6, -33 and -63 Chassis Configurations
The models depicted on pages 14-30 provide an overview of the various dimensions,
connectors and features available on Thinklogical’s VelocityDVI-3 and -6 chassis. The
VelocityDVI-33 and -63 back panels are shown on page 30.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
15
TRANSMITTER
_
POWER
5 VDC
RECEIVER
_
POWER
5 VDC
VelocityDVI-3 with Neutrik
®
OpticalCon DUO Connector
+
STATUS
L1 L2
+
STATUS
L2 L1
DDC MODE
ACQUIRE
LCL REM
SELECT
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI to Local Display
DDC
DVI from CPU
DVI to DisplayDVI to Display DDC
Velocity
dvi
Digital Video Extension System – 3
with Neutrik Connector
®
Transmitter
L1◄ Video/Data
Neutrik Connector
L2 ► Data
Powered by
MRTS Technology
7.00"
(177.80mm)
Physical dimensions are the same for both the Transmitter and Receiver chassis.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
16
TRANSMITTER
RECEIVER
POWER
VDC
5
POWER
5 VDC
VelocityDVI-3 A/V+
1.10"
(27.94mm)
_
+
STATUS
L1
L2
ACQUIRE
SELECT
1.10"
(27.94mm)
_
+
STATUS
L2
L1
ACQUIRE
LCL REM
SELECT
DVI to Local Display
DDC MODE
LCL REM
DDC MODE
DVI to Display DDC
DVI from CPU
DVI to Display
SERIAL
SERIAL
MIC
LINE
IN
OUT
MIC
LINE
OUT
IN
7.50" (190.50mm)
6.50" (165.10mm)
Velocity
Digital Video Extension System – 3 A/V+
dvi
Transmitter
DVI from CPUDVI to Local Display
L1 ◄ Video/Data
L2 ► Data
Powered by
MRTS Technology
7.00"
(177.80mm)
Physical dimensions are the same for both the Transmitter and Receiver chassis.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
17
VelocityDVI-3 A/V+ with Neutrik®
TRANSMITTER
RECEIVER
POWER
5 VDC
POWER
5VDC
OpticalCon DUO Connector
(50.80mm)
2.0"
_
+
STATUS
L1 L2
(50.80mm)
_
+
STATUS
L2 L1
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI to Local Display
DVI from CPU
SERIAL
MIC
OUT
LINE
IN
2.0"
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI to Display DDC
DVI to Display
SERIAL
MIC
LINE
OUT
IN
7.50" (190.50mm)
6.50" (165.10mm)
Velocity
Digital Video Extension System – 3 A/V+
with Neutrik Connector
®
dvi
Transmitter
Video/Data ◄ L1
Neutrik Connector
Data ► L2
Powered by
MRTS Technology
7.00"
(177.80mm)
Physical dimensions are the same for both the Transmitter and Receiver chassis.
DVI from CPUDVI to Local Display
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
18
Power
5VDC
Status
VelocityDVI-3 A/N+ Transmitter (Audio Network)
Network
10
FOL
TX
RX
LNK/ACT
+
Velocity
Digital Video Extension System – 3A/N+
Transmitter
Powered by
MRTS Technology
dvi
100
FD
COL
In
Line
Mic
Out
DVI from CPUDVI to Local Display
DVI from CPU
Transmitter
L1 ◄ Video/Data
L2 ► Data
7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
DVI to Local Display
Select
Acquire
DDC Mode
REMLCL
Transmitter
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
19
Power
5VDC
Status
FOL
TX
RX
LNK/ACT
+
VelocityDVI-3 A/N+ Receiver (Audio Network)
Network
10
FD
COL
Mic In
Out
Line
DVI to Display
DVI to DIsplay
Velocity
Digital Video Extension System – 3A/N+
Receiver
Powered by
MRTS Technology
dvi
100
Receiver
L2 ◄ Data
L1 ► Video/Data
7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
DVI to Display DDC
DVI to Display DDC
Select
Acquire
DDC Mode
REMLCL
Receiver
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
20
Power
5VDC
Status
FOL
TX
RX
LNK/ACT
+
VelocityDVI-3 A/N+ Transmitter with
Neutrik® OpticalCon DUO Connector
Network
10
FD
Velocitydvi
Digital Video Extension System – 3A/N+
with Neutrik Connector
Powered by
MRTS Technology
®
Transmitter
100
COL
In
Line
Mic
Out
DVI from CPUDVI to Local Display
DVI from CPU
Transmitter
L1 ◄ Video/Data
®
Neutrik Connector
L2 ► Data
7.00" (177.80mm) L x 7.49" (190.25mm) W x 2.00" (50.80mm) H
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
DVI to Local Display
Select
Acquire
REMLCL
DDC Mode
Transmitter
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
21
Network
10
FD
100
COL
In
Mic
Out
Line
DVI to Display
DVI to Display
Receiver
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
DDC
DVI to Display
Acquire
DDC Mode
DVI to Display DDC
Select
REMLCL
Receiver
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
22
VelocityDVI-6
(27.94mm)
1.10"
(27.94mm)
1.10"
TRANSMITTER
POWER
5V DC
RECEIVER
RECEIVER
POWER
5VDC
5.50" (139.70mm)
4.50" (114.30mm)
_
+
STATUS
L1
_
+
STATUS
L3
L2
L3
L2
L1
DDC MODE
ACQUIRE
LCL REM
SELECT
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI to Local
Display
DVI to Display DDC
DVI from CPU
DVI to Display
DVI from CPUDVI to Local Display
Velocity
dvi
Digital Video Extension System – 6
Dual-Link DVI
Lower ConnectorsUpper Connector
L1
L3
◄
◄
Video
L2 ► DataVideo/Data
Transmitter
Powered by
MRTS Technology
7.75"
(196.85mm)
Physical dimensions are the same for both the Transmitter and Receiver chassis.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
23
VelocityDVI-6 with Neutrik®
2.44" (61.98mm)
TRANSMITTER
_
POWER
5 VDC
2.44" (61.98mm)
RECEIVER
_
POWER
5 VDC
OpticalCon QUAD Connector
+
STATUS
+
STATUS
DDC MODE
ACQUIRE
LCL REM
SELECT
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI to Local Display
DDC
L2
L1
L3
L3
DVI from CPU
L2
L1
DVI to DisplayDVI to Display DDC
5.375" (136.65mm)
4.375" (111.13mm)
Video ► L3
Neutrik Connector
Data ◄ L2 Video/Data ► L1
Velocity
dvi
Digital Video Extension System – 6
with Neutrik Connector
®
Dual-Link DVI Transmitter
Powered by
MRTS Technology
7.00"
(177.80mm)
Physical dimensions are the same for both the Transmitter and Receiver chassis.
DVI from CPUDVI to Local Display
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
24
TRANSMITTER
RECEIVER
POWER
VDC
5
POWER
5 VDC
VelocityDVI-6 A/V+
1.10"
(27.94mm)
_
+
STATUS
L1
L2
L3
ACQUIRE
LCL REM
SELECT
1.10"
(27.94mm)
_
+
STATUS
L3
L2
L1
ACQUIRE
LCL REM
SELECT
DVI to Local Display
DDC MODE
DVI to Display DDC
DDC MODE
DVI from CPU
DVI to Display
SERIAL
SERIAL
MIC
OUT
MIC
LINE
IN
LINE
OUT
IN
7.50" (190.50mm)
6.50" (165.10mm)
Lower Connector
L1 ◄ Video/Data
L3 ◄ Video
Velocity
Digital Video Extension System – 6 A/V+
Dual-Link DVI
Upper Connector
L2 ► Data
dvi
Transmitter
DVI from CPUDVI to Local Display
Powered by
MRTS Technology
7.75"
(196.85mm)
Physical dimensions are the same for both the Transmitter and Receiver chassis.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
25
VelocityDVI-6 A/V+ with Neutrik®
TRANSMITTER
RECEIVER
POWER
5 VDC
POWER
5VDC
OpticalCon QUAD Connector
(61.98mm)
2.44"
_
+
STATUS
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI to Local Display
(61.98mm)
2.44"
_
+
STATUS
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI to Display DDC
L2
L1 L3
DVI from CPU
L3
DVI to Display
MIC
LINE
IN
OUT
SERIAL
L2
L1
MIC
LINE
OUT
SERIAL
IN
7.50" (190.50mm)
6.50" (165.10mm)
Velocity
Digital Video Extension System – 6 A/V+
with Neutrik Connector
®
dvi
Dual-Link DVITransmitter
Video ► L3
DVI from CPUDVI to Local Display
Neutrik Connector
Data ◄ L2 Video/Data ► L1
Powered by
MRTS Technology
7.00"
(177.80mm)
Physical dimensions are the same for both the Transmitter and Receiver chassis.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
26
Power
5VDC
Status
FOL
TX
RX
LNK/ACT
+
VelocityDVI-6 A/N+ Transmitter
Network
10
FD
COL
In
Line
Mic
Out
DVI
DVI to
DVI from CPUDVI to Local Display
from CPU
Local Display
Velocity
Digital Video Extension System – 6A/N+
Dual-Link DVITransmitter
Powered by
MRTS Technology
dvi
100
Transmitter
Lower ConnectorLower Connector
L1 ◄ Video/Data
L3 ◄ Video
L2 ► Data
7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
Select
Acquire
DDC Mode
REMLCL
Transmitter
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
27
Power
5VDC
Status
FOL
TX
RX
LNK/ACT
+
VelocityDVI-6 A/N+ Receiver
Network
10
FD
COL
In
Mic
Out
Line
DVI to DisplayDVI to Display DDC
DVI to Display
Velocity
Digital Video Extension System – 6A/N+
Dual-Link DVIReceiver
Powered by
MRTS Technology
dvi
100
Receiver
Lower ConnectorUpper Connector
L3 ► Video
L1 ► Video/Data
L2 ◄ Data
7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
DVI to Display DDC
Select
Acquire
DDC Mode
REMLCL
Receiver
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
28
Network
10
FD
100
COL
In
Line
Mic
Out
DVI from CPUDVI to Local Display
DVI from CPU
Transmitter
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
DVI to Local Display
Select
Acquire
REMLCL
DDC Mode
Transmitter
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
29
Power
5VDC
Status
FOL
TX
RX
LNK/ACT
+
Velocity-6 A/N+ Receiver with
Neutrik® QUAD OpticalCon Connector
Network
10
FD
Velocity
Digital Video Extension System – 6A/N+
with Neutrik Connector
Dual-Link DVIReceiver
Powered by
MRTS Technology
®
dvi
100
COL
Mic In
Out
Line
DVI to DisplayDVI to Display DDC
DVI to Display
Receiver
L3 ► Video
®
Neutrik Connector
L1 ► Video/Data
L2 ◄ Data
7.75" (196.85mm) L x 7.49" (190.25mm) W x 2.00" (50.80mm) H
Front Panel Network Status LEDS:
FOL is ON when Fiber Optic Link is OK.
TX is ON when data is transferring from TX to RX.
RX is ON when data is transferring from RX to TX.
LNK/ACT is ON when link is established. Flashes
when actively transferring data.
DVI to Display DDC
Select
Acquire
REMLCL
DDC Mode
Receiver
Rear Panel Network Status LEDS:
10/100:
When lit, speed of link is 100 Mb/sec.
When off, speed of link is 10 Mb/sec.
FD/COL:
When lit, indicates operation in Full Duplex.
When off, indicates operation in Half Duplex.
When blinking, indicates Collision.
On the RJ45 Connector:
Green LED = Link
Yellow LED (blinking) = Activity
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
30
Velocitydvi-33 and -63 Transmitter and Receiver Back Panels
Velocitydvi-33 Transmitter Receiver
Velocitydvi-63 Transmitter Receiver
3.2.1. Table of VelocityDVI Chassis Dimensions
VelocityDVI Model DIMENSIONS (inches) DIMENSIONS (metric)
VEL-3 5.375"W x 7.0"D x 1.1"H 136.65mm x 177.80mm x 27.94mm
VEL-3 with Neutrik® 5.375"W x 7.0"D x 2.0"H 136.65mm x 177.80mm x 50.80mm
VEL-3 AV+ 7.5"W x 7.0"D x 1.1"H 190.50mm x 177.80mm x 27.94mm
VEL-3 AV+ w/ Neutrik® 7.5"W x 7.0"D x 2.0"H 190.50mm x 177.80mm x 50.80mm
VEL-3 AN+ 7.5"W x 7.0"D x 1.1"H 190.50mm x 254.00mm x 27.94mm
VEL-3 AN+ w/ Neutrik® 7.5"W x 7.0"D x 2.0"H 190.50mm x 177.80mm x 50.80mm
VEL-6 5.5"W x 7.75"D x 1.1"H 139.65mm x 196.85mm x 27.94mm
VEL-6 with Neutrik® 5.375"W x 7.0"D x 2.44"H 136.65mm x 177.80mm x 61.98mm
VEL-6 AV+ 7.5"W x 7.75"D x 1.1"H 190.50mm x 196.85mm x 27.94mm
VEL-6 AV+ w/ Neutrik® 7.5"W x 7.0"D x 2.44"H 190.50mm x 177.80mm x 61.98mm
VEL-6 AN+ 7.5”W x 7.75” D x 1.1”H 190.50mm x 196.85mm x 27.94mm
VEL-6 AN+ w/ Neutrik® 7.5”W x 7.75” D x 2.0”H 190.50mm x 196.85mm x 50.80mm
VEL-33 (rack-mount) 19.0"W x 10.0"D x 1.72"H 482.60mm x 254.00mm x 43.69mm
VEL-63 (rack-mount) 19.0"W x 7.84"D x 1.72"H 482.60mm x 199.14mm x 43.69mm
Refer to Paragraph 1.3 beginning on page 5 for the complete line of VelocityDVI-3 & -6 Extenders.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
31
4. DDC and EDID
DDC (Display Data Channel) is a VESA standard transport medium between a CPU’s graphics adapter
and monitor. The DDC is used to pass EDID (Extended Display Identification Data), which is stored in
the monitor and describes its characteristics (vendor name, serial number, frequency range, etc.). With
this information the CPU and video card can determine what resolutions the monitor is capable of.
The DDC bus can be unidirectional or bidirectional. A bidirectional bus supports content protection
(HDCP) and display calibration software. (High-bandwidth Digital Content Protection is a specification
used to encrypt and protect digital video and audio signals transmitted between two HDCP-enabled
devices.)
NOTE: Most DVI-D graphics adapters will not boot if a valid EDID table is not received at
power up.
4.1. Default DDC Modes
4.1.1. Remote Dynamic Mode
System-3:
The unit acts as a direct connection between the RX and TX. In this mode DDC data is read at the RX
and sent to the TX. Once verified at the TX the information is written into a PROM on the TX and
provided to the CPU video card. The RX will not send DDC data to the TX unless a different display is
connected to the RX.
Advantages:Allows CPU video card to boot when there is no fiber connection to the RX.
Limitations:No communication link from the CPU to the display. Prevents the use of HDCP or monitor
configuration /color tuning.
2 fibers required, System-6: 3 fibers required
NOTE: When switching between DDC modes (except Pass-Thru), you will need to press the
Remote Static Mode is a subset of Dynamic Mode in that once a transfer from the RX to the TX is
completed successfully no other transfer will be made unless specifically requested by using the
ACQUIRE Button. The DDC data stored in the TX PROM will not change regardless of display changes.
Advantages:Allows the user to acquire and use an EDID table regardless of changes in connection at
the RX.
Limitations: No communication link from the CPU to the display. Prevents the use of HDCP or monitor
configuration/color tuning. May not produce video if a display with lower resolution capability is
subsequently connected.
The units act as a direct connection between the TX and RX. This mode allows the CPU to communicate
directly with the monitor.
Advantages:Allows monitor color tuning and HDCP.
Limitations:If a monitor is not connected to the RX most video cards will not boot.
4.1.4 Local Static Mode
Sys-3: 1fiber required, Sys-6: 2 fibers required
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
32
Local Static mode operates in the same manner as Remote Static mode except that the EDID table
is read from a monitor plugged into the local port of the TX. Once the
ACQUIRE
button is pressed
the TX will begin reading the DDC from the locally connected monitor until a valid EDID table is read.
The table will then be stored on the TX and presented to the CPU.
Advantages:
The TX does not need to be connected to the video card or RX.
The EDID table can be loaded before the TX is installed.
Limitations: No communication link from the CPU to the display. This prevents the use of HDCP or
monitor configuration /color tuning and may result in loss of remote video if a display with lower resolution
capability is connected to the RX.
4.2
Load Default EDID Table
Holding the ACQUIRE and SELECT buttons for 5
seconds will reload the default DDC table into the
TX, and switch the DDC mode to Remote Static.
The TX Status LED will turn Orange while the
default table is loaded and then change to Green.
Advantages:
Sends a valid EDID table to the
CPU in order for the graphics adapter to boot.
Limitations:
Default EDID table may not support
required resolutions.
Feature
Remote
Dynamic
Remote Static Pass-Thru Local Static Load Default
Supports
HDCP
Supports
monitor
calibration
Monitor on RX
side required
to boot video
EDID table
loaded from
Rx
EDID table
loaded from
Tx
EDID table
stored in nonvolatile
memory
Fibers
required
System-3
No No Yes No No
No No Yes No No
No No Yes No No
Yes Yes Yes No No
No No No Yes No
Yes Yes No Yes Yes
2
2 initially, then
L1 only
2 1 1
Fibers
required
System-6
3
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
3 initially, then
L1 and L3
only
EDID Capability Summary
3 2 2
2 0 1 3
Page
33
4.2.1 DDC LEDs and Mode Button Operation
•Acquire Button
The upper button is the Acquire Button. This button is used to initiate DDC collection. This button works
with all modes except Pass-Thru.
•Select Button
The lower button is used to select the DDC Mode of operation. The modes will cycle through Remote
Dynamic, Remote Static, PassThru and Local Static.
•Both Buttons Held 5 seconds
Holding both buttons for 5 seconds will reload the default DDC table into the TX and switch to Remote
Static mode.
•Local and Remote LED Mode Indication
LCLREMDDC MODEDESCRIPTION
REMOTE
OFF
ORANGE
GREEN
GREEN
GREEN
GREEN
GREEN
ORANGE
DYNAMIC
REMOTE
STATIC
PASS-
THRU
LOCAL
STATIC
EDID READ FROM REMOTE DISPLAY
AND UPDATED EACH TIME REMOTE
DISPLAY CHANGES.
EDID READ FROM REMOTE DISPLAY
WHEN ACQUIRE BUTTON IS PRESSED.
ACTS AS A DIRECT CONNECTION
BETWEEN CPU AND DISPLAY. NO
EMULATION IS PERFORMED.
EDID READ FROM LOCAL DISPLAY
WHEN ACQUIRE BUTTON IS PRESSED.
• TX Status LED
The status LED indicates the connection status of the TX Extender.
Green = Fiber L2 is connected and a good link is established.
Orange = Local Static Mode selected and no fiber link from RX to TX (L2 is not connected), or both
buttons are held down and the unit is waiting to reload the default DDC table.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
34
Red Flashing = No Fiber Link from RX to TX (Not available in Local Static mode).
For VEL-6 models, there is no LED indication for Fiber L3. In single-link mode, video is not affected if L3
is not connected. In dual-link mode, there will be no video if L3 is not connected.
• RX Status LED
The status LED indicates the connection status of the RX Extender.
Green = Good Link and DVI monitor connected to primary port (port on left looking at DVI connectors).
Orange = No DVI monitor connected to primary port.
Red Flashing = No Fiber Link from TX to RX (L1 is not connected).
•Power LED
When lit, the Green LED near the power jack indicates that +5VDC power is applied to the unit.
•Grounding Stud
A grounding stud located below the power jack allows the unit to be hard-wired to electrical ground if
required.
5. Regulatory and Safety Compliance
5.1.
Markings and labels on our products follow industry-standard conventions. Regulatory markings
found on our products comply with all domestic and many international requirements.
Symbols Found on Our Products
5.1.1. Class 1 Laser Labeling
The DVI Extender
products.
models VEL-3, -6, -33 and -63
are designed and identified as Class 1 LASER
5.2. Regulatory Compliance
Thinklogical VelocityDVI Extender products are designed and made in the USA. VelocityDVI Extender
products have been tested by a nationally recognized testing laboratory and found to be
compliant with the following standards (both domestic USA and many international locations).
5.2.1. North America
These products comply with the following standards:
Safety
•
ANSI/UL60950-1: 1st Edition (2003)
•
CAN/CSA C22.2 No. 60950-1-03
Laser Safety
•
CDRH 21 CFR 1040.10
•
Class 1 Laser Product: VEL-3, VEL-6, VEL-33, VEL-63
•
Accession Number TBD
Electromagnetic Interference
•
FCC CFR47, Part 15, Class A
•
Industry Canada ICES-003 Issue 2, Revision 1
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
35
5.2.2. Australia & New Zealand
This is a Class A product. In a domestic environment this product may cause radio interference, in
which case the user may be required to take corrective measures.
5.2.3. European Union
5.2.3.1. Declaration of Conformity
Product name
VelocityDVI Digital Video Extension System-3, VelocityDVI Digital Video Extension System-6,
VelocityDVI Digital Video Extension System-33, VelocityDVI Digital Video Extension System-63
These products comply with the requirements of Low Voltage Directive 72/23/EEC and EMC Directive
89/336/EEC.
5.2.3.2. Standards Compliance
Safety
•
CENELEC EN 60950-1, 1st Edition (2001)
Laser Safety
•
IEC60825:2001 Parts 1 and 2
•
Class 1 Laser Product
Electromagnetic Emissions
•
EN55022: 1994 (IEC/CSPIR22:1993)
•
EN61000-3-2/A1 4:2000
•
EN61000-3-3:1994
Electromagnetic Immunity
•
EN55024:1998 Information Technology Equipment-Immunity Characteristics
•
EN61000-4-2:1995 Electro-Static Discharge Test
•
EN61000-4-3:1996 Radiated Immunity Field Test
•
EN61000-4-4:1995 Electrical Fast Transient Test
•
EN61000-4-5:1995 Power Supply Surge Test
•
EN61000-4-6:1996 Conducted Immunity Test
•
EN61000-4-8:1993 Magnetic Field Test
•
EN61000-4-11:1994 Voltage Dips & Interrupts Test
5.2.4. Supplementary Information
The following statements may be appropriate for certain geographical regions but might
not apply to your location.
NOTE: This equipment has been tested and found to comply with the limits for a Class 1
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment uses, generates and can
radiate radio frequency energy and if not installed and used in accordance with the
instruction manual may cause harmful interference to radio communications, in which
case the user may be required to correct the interference.
NOTE: This Class 1 digital apparatus complies with Canadian ICES-003 and has been
verified as compliant within the Class A limits of the FCC Radio Frequency Device
Rules (FCC Title 47, Part 15, Subpart B Class A), measured to CISPR 22: 1993 limits
and methods of measurement of Radio Disturbance Characteristics of Information
Technology Equipment.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
36
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numerique de la classe A respecte toutes les exigencies du Reglement sur le material
brouilleur du Canada.
NOTE: The user may notice degraded audio performance in the presence of electro-
magnetic fields.
5.2.5. Product Serial Number
Thinklogical® products have a unique serial number printed on an adhesive label that is fixed to
the bottom of the chassis. The serial number includes a date-code. The format for the date-code
is 2 digits for the week, 2 digits for the year, plus two or three digits for a unique unit number.
This serial number is also found on the original shipping carton.
6. How to Contact Us
6.1. Customer Support
Thinklogical® is an engineering company and you will receive any information you require directly
from our most knowledgeable engineers. We believe that the first lines of support are the design
engineers that developed each particular product. Therefore, your questions will be handled
promptly by our in-house engineers who are most familiar with your products.
Thank you for choosing Thinklogical® products for your application.
To contact us, please use the following telephone numbers and internet-based methods:
Website
Check out our website for current product offerings, support information and general information about all
of the products we offer.
Our internet website offers product information on all current systems, including technical specification
sheets and installation guides (for viewing online or for download), product diagrams showing physical
connections and other information you might need.
Internet: www.thinklogical.com
Note: Most online documents are stored as Adobe Acrobat “PDF” files. If you do not have
the Adobe Acrobat reader needed to view PDF files, visit www.adobe.com for a download.
Email
Thinklogical® is staffed Monday through Friday from 8:30am to 5:00pm, Eastern Time Zone. We will do
our best to respond to your email inquiries promptly. Please use one of the following email addresses:
info@thinklogical.com – Information on Thinklogical® and our products.
sales@thinklogical.com – Sales Department - orders, questions or issues.
support@thinklogical.com – Product support, technical issues or questions, product
repairs and request for Return Authorization.
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
37
Telephone
Please contact our expert sales staff in Milford, CT at 1-203-647-8700 or if in the continental US, you may
use our toll-free number 1-800-291-3211. We are here Monday through Friday from 8:30am to 5:00pm,
Eastern Time Zone. Ask for a representative’s direct dial phone number when you call.
Telephone Product Support: Contact Product Support in Milford, Connecticut at 1-203-647-8700. The
support lines are manned Monday through Friday, 8:30am to 5:00pm, Eastern Time Zone.
International Sales: Please contact our US sales staff in Milford, CT at 1-203-647-8700. We are here
Monday through Friday, 8:30am to 5:00pm, Eastern Time Zone (same as New York City). If leaving a
voice message, please provide a preferred time to call back so we may reach you at your convenience.
Our switchboard attendant will direct your call during regular business hours. We have an automated
attendant answering our main telephone switchboard after regular business hours and holidays. You can
leave voice messages for individuals at any time. Our Sales Representatives have direct numbers to
facilitate your next call to us.
Fax
Our company facsimile number is 1-203-783-9949. Please indicate the nature of the fax on your cover
sheet and provide return contact information.
6.2. Product Support
Thinklogical’s® support personnel are available Monday through Friday from 8:30am to 5:00pm, Eastern
Time Zone. If your application might require assistance at some time outside of our normal business
hours, please contact us beforehand and we will do our best to make arrangements to help you with your
Thinklogical® products.
Warranty
Thinklogical® warrants this product against defects in materials and workmanship for a period of one year
from the date of delivery. Thinklogical® and its suppliers disclaim any and all other warranties.
Note: Thinklogical® Inc. products carry a one year warranty, with longer term available at time
of purchase on most products. Please refer to your product invoice for your products
Warranty Terms & Conditions.
Defect remedy shall be, repair or replacement of the product, provided that the defective product is
returned to the authorized dealer within a year from the date of delivery.
If you wish to return your device, contact the Thinklogical® authorized dealer where you purchased the
device, or if you purchased directly, call Thinklogical at 1-800-291-3211 (USA).
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
38
Return Authorization
If you have any issue with any Thinklogical product, have product questions or need technical assistance
with your Thinklogical system, please contact Customer Support at 1-800-291-3211 (USA only) or 1-203-647-8700 and let us help.
If you must return a product to Thinklogical® directly, Customer Support will ask you to describe the
problem and will issue you a Return Merchandise Authorization number (RMA#). Pack the device in its
original box, if possible, and return it with the RMA# on the box.
Note: Do not return a product to Thinklogical® without an approved Return Material
Authorization Number.
Return address for products with Return Material Authorization:
Thinklogical, LLC®
Attn: RMA#
100 Washington Street
Milford, CT 06460 USA
PH: 1-800-291-3211 (USA only)
1-203-647-8700
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
39
Appendix A: Installation Overview
A.1. VEL-3
Velocitydvi
Digital Video Extender-3 Installation Overview
STEP 4: Connect the supplied AC Power
Adapter (PWR-000022-R) to the Tx and
plug it into a standard AC source.
STEP 5: Connect the video source
(CPU) to the Tx with a DVI-D M-M
Cable. An optional local display can also
be connected using a DVI-D M-M Cable.
STEP 2: Connect the supplied AC Power
Adapter (PWR-000022-R) to the Rx and
plug it into a standard AC source.
1
Power Supply
(PWR-000022-R)
L1
L2
Transmitter VEL-000M03-LCTX
STEP 1: Connect multi-mode fiber optic cables
(up to 1000 meters) between the Rx and Tx units.
L1: Data Tx to Rx & Video
L2: Data Rx to Tx
Power Supply
(PWR-000022-R)
4
2
CPU
5
Local
Monitor
L2
L1
Receiver VEL-000M03-LCRX
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
DVI OUT
3
Primary DDC Port
STEP 3: Connect the DVI to Display DDC
port to a video monitor (or projector or other
viewing device) with a DVI-D M-M Cable. A
second device can be installed at the DVI to Display port using a similar cable. Turn on the
DVI video devices.
2 0 1 3
DVI OUT
DDC
Page
40
A.2. VEL- 3 A/V+
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
41
A.3. VEL-6
Velocitydvi
Digital Video Extender-6 Dual-Link Installation Overview
STEP 4: Connect the supplied AC Power
Power Supply
(PWR-000022-R)
4
Adapter (PWR-000022-R) to the Tx and
plug it into a standard AC source.
5
L1
L2 L3
STEP 5: Connect the video source
1
Transmitter VEL-000M06-LCTX
STEP 1: Connect multi-mode fiber optic cables
(up to 1000 meters) between the Rx and Tx units.
L1: Data Tx to Rx & Video Primary
L2: Data Rx to Tx
L3: Video Secondary
Power Supply
(PWR-000022-R)
2
STEP 2: Connect the supplied AC Power
Adapter (PWR-000022-R) to the Rx and
plug it into a standard AC source.
(CPU) to the Tx with a DVI-D M-M
Cable. An optional local display can also
be connected using a DVI-D M-M Cable.
CPU
Local
Monitor
Dual-Link
DVI OUT
L3 L2
L1
Receiver VEL-000M06-LCRX
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
3
Primary DDC Port
STEP 3: Connect the DVI to Display DDC
port to a video monitor (or projector or other
viewing device) with a DVI-D M-M Cable. A
second device can be installed at the DVI to Display port using a similar cable. Turn on the
DVI video devices.
2 0 1 3
Dual-Link
DVI OUT
DDC
Page
42
A.4. VEL-6 A/V+
Velocitydvi
Digital Video Extender-6AV+ Installation Overview
STEP 4: Connect the supplied AC Power
Power Supply
(PWR-000022-R)
L1
4
Adapter (PWR-000022-R) to the Tx and
plug it into a standard AC source.
5
CPU
RJ45 to
DB9
Local
Monitor
1
L2 L3
Transmitter VEL-AV0M06-LCTX
STEP 1: Connect multi-mode fiber optic cables
(up to 1000 meters) between the Rx and Tx units.
L1: Data Tx to Rx & Video Primary
L2: Data Rx to Tx
L3: Video Secondary
Power Supply
(PWR-000022-R)
L3 L2
2
STEP 5: Connect the video source (CPU) to
the Tx with a DVI-D M-M Cable. An optional
local display can also be connected using a
DVI-D M-M Cable. Connect the Audio IN
and OUT and Serial sources to the Tx with
standard copper cables
STEP 2: Connect the supplied
AC Power Adapter (PWR000022-R) to the Rx and plug it
into a standard AC source.
Primary DDC Port
External RS-232 or RJ45 Device
3
RJ45 to
Dual-Link
DVI OUT
Dual-Link
DVI OUT
DDC
DB9
L1
Receiver VEL-AV0M06-LCRX
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
STEP 3: Connect the DVI to Display DDC
port to a video monitor (or projector or other
viewing device) with a DVI-D M-M Cable. A
second device can be installed at the DVI to Display port using a similar cable. Connect
the audio and serial devices with standard
copper cables. Turn all the devices ON.
2 0 1 3
A.5 VEL-33
Optical Fibers (up to 1000 meters)
available with ST-, SC- or LC-type
DVI-D cables, connect the
desired video output
devices to the Receiver
Unit’s DVI OUT receptacles.
For each of the three video
output pairs, DVI OUT 1 is
the DDC port.
STEP 2: Ensure that the Power Switch is
in the OFF (0) position. Connect the
supplied AC Power Cord (PWR-000006-R)
to the Receiver’s power receptacle, plug it
into a standard AC source and turn the
unit ON (1).
STEP 1: Connect the multi-
mode fiber optic cables
between the Tx and Rx
Units (up to 1000 meters).
Do not kink or pinch the
cables and be sure to keep
all bend radii to no less than
3 inches.
STEP 5: Using the
supplied DVI-D male to
male cables, connect
the desired video output
devices to the
Transmitter Unit’s DVI
OUT receptacles.
STEP 6: Using the
supplied DVI-D male to
male cables, connect the
video output sources to
the Transmitter Unit’s DVI
IN receptacles. Ensure
that all system functions
are operating properly.
CPU
1
CPU
2
CPU
3
STEP 4: Ensure that the
Power Switch is in the OFF
(0) position. Connect the
supplied AC Power Cord
(PWR-000006-R) to the
Transmitter’s power
receptacle, plug it into a
standard AC source and
turn the unit ON (1).
Digital Video Extension System - 33
MRTS Technology
Transmitter
Powered by
STATUSSTATUSSTATUS
Tx STATUS LEDs
GREEN: Fibers connected, good link
established.
ORANGE: Local Status Mode selected, no
fiber link from Rx to Tx, or both DDC Mode
buttons held down (waiting to reload
default DDC table).
RED flashing: No fiber link from Rx to Tx.
Rx STATUS LEDs
GREEN: DVI monitor has good link to primary DVI
OUT port (labeled DDC).
ORANGE: No DVI monitor connected to primary port
RED flashing: No fiber link from Tx to Rx.
TRANSMITTER
RECEIVE
R
QUICK START GUIDE
Digital Video Extension System -
33
The Primary Port on the Rx is used for DDC.
The Secondary Port carries video data only.
VELOCITY-33_Manual_Quick_Start_Re
v
_
C
USE ONLY WITH 250V FUSE
USE ONLY WITH 250V FUSE
1
2
1
2
1
2
1
2
3
6
5
4
1
2
3
Page
44
A.6 VEL-63
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
45
Appendix B: DVI Extender Mounting
Each VelocityDVI Extender-3 and -6 can be used as a desk top or wall-mounted device. Mounting
centers are provided with keyhole slots. Users may choose the most appropriate fasteners and anchors
to mount each unit according to the requirements of each application. VelocityDVI-33 and -63 chassis
can be desk-top (feet provided) or standard EIA 19” rack-mounted.
Note: Be sure to leave adequate clearance (3 inch minimum bend radius) for your
Fiber Cable.
3"
UNIT DIMENSIONS (inches) DIMENSIONS (metric)
Vel-3 5.375"W x 7.0"D x 1.1"H 136.65mm x 177.80mm x 27.94mm
Vel-3 with Neutrik® 5.375"W x 7.0"D x 2.0"H 136.65mm x 177.80mm x 50.80mm
Vel-3 AV+ 7.5"W x 7.0"D x 1.1"H 190.50mm x 177.80mm x 27.94mm
Vel-3 AV+ w/ Neutrik® 7.5"W x 7.0"D x 2.0"H 190.50mm x 177.80mm x 50.80mm
Vel-3 AN+ 7.5"W x 7.0"D x 1.1"H 190.50mm x 254.00mm x 27.94mm
Vel-3 AN+ w/ Neutrik® 7.5"W x 7.0"D x 2.0"H 190.50mm x 177.80mm x 50.80mm
Vel-6 5.5"W x 7.75"D x 1.1"H 139.65mm x 196.85mm x 27.94mm
Vel-6 with Neutrik® 5.375"W x 7.0"D x 2.44"H 136.65mm x 177.80mm x 61.98mm
Vel-6 AV+ 7.5"W x 7.75"D x 1.1"H 190.50mm x 196.85mm x 27.94mm
Vel-6 AV+ w/ Neutrik® 7.5"W x 7.0"D x 2.44"H 190.50mm x 177.80mm x 61.98mm
Vel-6 AN+ 7.5”W x 7.75” D x 1.1”H 190.50mm x 196.85mm x 27.94mm
Vel-6 AN+ w/ Neutrik® 7.5”W x 7.75” D x 2.0”H 190.50mm x 196.85mm x 50.80mm
Vel-33 (rack-mount) 19.0"W x 10.0"D x 1.72"H 482.60mm x 254.00mm x 43.69mm
Vel-63 (rack-mount) 19.0"W x 7.84"D x 1.72"H 482.60mm x 199.14mm x 43.69mm
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
46
Appendix C: RJ-45 Adapter Pin-outs
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
47
Appendix D: Automatic Fail-Over Option
For applications in need of an Automatic Fail-Over system, Thinklogical offers a solution to
meet this need. This option allows for two separate fiber paths and the ability to select which of
the two paths is the viable path. This feature is available on the transmitter unit only.
The transmitter contains all the same features as the standard Velocity products in addition to
offering a redundant fiber connector (L1’) for each standard fiber connector (L1). All other
features function as described previously in the manual.
Velocity 3 TX with Automatic Fail-Over
Fiber Connections
L1 and L1' are redundant outputs, outputting the same video and KMASS data.
L2 and L2' are redundant back-channel KMASS data inputs. There is an internal MUX which
selects L2 or L2' data. When the unit is powered on, it will select L2 first (if L2 is active).
Otherwise, it will select L2' (if L2' is active). It will only switch from L2 to L2' if L2 is inactive and
L2' is active. It will only switch from L2' to L2 if L2' is inactive and L2 is active.
Velocitydvi-3 Transmitter with Automatic Fail-Over
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.