Thinklogical Velocitydvi-3, Velocitydvi-33, Velocitydvi-6, Velocitydvi-63 Product Manual

Digital Video Extension System
Velocitydvi-3, Velocitydvi-33
Velocitydvi-6, Velocitydvi-63
Single-Link and Dual-Link Fiber Extension Systems
Thinklogical, LLC®
100 Washington Street
Milford, Connecticut 06460 U.S.A.
Telephone: 1-203-647-8700
www.thinklogical.com
Copyright Notice
Copyright © 2013. All rights reserved. Printed in the U.S.A.
Thinklogical, LLC®
100 Washington Street Milford, Connecticut 06460 U.S .A. Telephone 1-203-647-8700
All trademarks and service marks are the property of their respective owners.
Subject: VelocityDVI-3, VelocityDVI-6, VelocityDVI-33 and VelocityDVI-63 Extender Product Manual Revision:
G (May, 2013)
Page
1
Table of Contents
1.
I
NTRODUCTION ....................................................................................................... 3
1.1. C
ONTENTS
1.2. P
RODUCT OVERVIEW
1.3. T
HE VELOCITY
1.4. L
ASER INFORMATION
2.
S
YSTEM FEATURES ................................................................................................... 9
2.1. G
ENERAL SYSTEM FEATURES
2.2. B
ASIC OPERATION
2.3. S
INGLE FIBER OPERATION, SYSTEM
2.4. D
UAL FIBER OPERATION, SYSTEM
2.5. F
IBER OPERATION, SYSTEM
2.6. T
ECHNICAL SPECIFICATIONS (SYSTEMS
2.7. V
ELOCITY UNBALANCED AUDIO SPECIFICATIONS
3.
I
NSTALLING THE
3.1. AC P
3.2. T
HE VELOCITY
3.2. 1. T
4.
DDC
4.1. D
EFAULT
4.1.1. R
EMOTE DYNAMIC MODE
4.1.2. R
4.1.3. P
4.1.4. L
4.2. L
OAD DEFAULT
4.2.1. DDC LED
5.
R
EGULATORY AND SAFETY COMPLIANCE ................................................................. 34
5.1. S
AFETY REQUIREMENTS
5.1.1. S
5.1.1.1. C
5.2. R
EGULATORY COMPLIANCE
5.2.1. N
5.2.2. A
5.2.3. E
5.2.3.1. D
5.2.3.2. S
5.2.4. S
5.2.5. P
6.
H
OW TO CONTACT US .............................................................................................. 36
6.1. C
USTOMER SUPPORT
6.1.1. W
6.1.2. E
6.1.3. T
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
................................................................................................................. 3
.................................................................................................... 3
DVI-3
AND -6 EXTENDER MODELS
................................................................... 5
..................................................................................................... 9
............................................................................................ 9
....................................................................................................... 10
-3 ............................................................................... 10
-3 ................................................................................. 10
-6 ........................................................................................ .10
-3, -6, -33
AND
-63) .................................................. 11
.................................................................. 12
DVI E
OWER
................................................................................................................. 13
DVI-3, -6, -33, -63 C
ABLE OF VELOCITY
XTENDERS............................................................................ 12
HASSIS CONFIGURATIONS
DVI C
HASSIS DIMENSIONS
............................................................... 30
................................................. 14
(DISPLAY DATA CHANNEL
DDC M
ODES
)
AND
EDID
(E
XTENDED DISPLAY IDENTIFICATION DATA
)
................... 31
................................................................................................. 31
....................................................................................... …..31
EMOTE STATIC MODE
ASS-THRU MODE
OCAL STATIC MODE
EDID T
S AND MODE BUTTON OPERATION
........................................................................................... 31
................................................................................................. 31
............................................................................................... 31
ABLE
............................................................................................ 32
.................................................................... 33
................................................................................................ 34
YMBOLS FOUND ON OUR PRODUCTS
LASS 1 LASER LABELING
................................................................................... 34
.......................................................................... 34
............................................................................................ 34
ORTH AMERICA
USTRALIA & NEW ZEALAND
UROPEAN UNION
ECLARATION OF CONFORMITY
TANDARDS COMPLIANCE
UPPLEMENTARY INFORMATION
RODUCT SERIAL NUMBER
................................................................................................... 34
.................................................................................... 35
.................................................................................................. 35
........................................................................... 35
.................................................................................. 35
................................................................................. 35
....................................................................................... 36
..................................................................................................... 36
EBSITE
............................................................................................................... 36
MAIL
................................................................................................................... 36
ELEPHONE
............................................................................................................ 37
2 0 1 3
Page
2
6.1.4. FAX ...................................................................................................................... 37
6.2. P
RODUCT SUPPORT
6.2.1. W
6.2.2. R
ARRANTY
ETURN MERCHANDISE AUTHORIZATION
....................................................................................................... 37
............................................................................................................ 37
....................................................................... 38
A
PPENDIX A: INSTALLATION OVERVIEW ............................................................................ 39
A.1 VEL-3 ........................................................................................................................ 39
A.2 VEL-3 A/V+ ................................................................................................................ 40
A.3 VEL-6 ........................................................................................................................ 41
A.4 VEL-6 A/V+ ................................................................................................................ 42
A.5 VEL-33 ...................................................................................................................... 43
A.6 VEL-63 ...................................................................................................................... 44
A
PPENDIX B:
A
PPENDIX C:
A
PPENDIX D: AUTOMATIC FAIL-OVER OPTION ................................................................. 47
DVI E RJ45 A
XTENDER MOUNTING ......................................................................... 45
DAPTER PIN-OUTS ........................................................................... 46
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
3
1. Introduction
1.1. Contents
Upon receiving your
Thinklogical VelocityDVI Extension System®
you should find the following
items:
DVI Extender Transmitter
DVI Extender Receiver
DVI-D Male to Male Cable, 2 Meter (CBL-000009-002MR)1
DVI-D Male to Male Dual-Link Cable, 2 Meters (CBL-000023-002MR)2
Universal AC Power Adapters (PWR-000022-R) – Quantity 2 (Vel-3, -6)
AC Power Cord (PWR-000006-R) – Quantity 2 (Vel-33, -63)
CAT5 Cable Assembly (CBL000001-002MR)3
3.5mm Audio Cable, M-M – Quantity 2 (CBL000016-006FR)3
DB9F Adapter (ADP-000025-R) and DB9M Adapter (ADP-000019-R)4
CD Product Manual
1 For VelocityDVI-3, Qty = 1 each. For VelocityDVI-33, Qty = 3 each
2 For VelocityDVI-6, Qty = 1 each. For VelocityDVI-63, Qty = 3 each
3
With A/V+ and A/N+ models
4
With A/V+ models only
1.2. Product Overview
MRTS Technology 6.25 Gbps. allows for Full Frame Rate Transmission of uncompressed DVI.
Powered by Thinklogical’s® cutting edge, patent-pending MRTS (Multi Rate Transmission System) Technology, our DVI Extension Systems transport every frame of a DVI video stream seamlessly with no compression or dropped frames. In addition, all high speed peripherals function with no latency. Incorporating standard SFP+ transceivers, the system uses multi-mode fiber optic cable to placement of a digital monitor or projector up to 1000 meters (3280 feet) away from the controlling computer without loss of resolution. Thinklogical® also offers optics that cables to allow
the placement of video devices up to 10, 40 or 80 km (6.2/24.8/49.7 miles) away from
use single-mode fiber optic
the controlling computer without loss of resolution. Installation is plug-and-play and no adjustments are necessary.
Each VEL-3 (single-link) and VEL-6 (dual-link) system consists of one transmitter per chassis and one receiver per chassis. The rack-mountable VEL-33 system (single-link) and the rack­mountable VEL-63 system (dual-link) each feature three transmitters per chassis and three receivers per chassis.
All models support Data Display Channel (DDC), with a variety of modes to meet each unique requirement. All models are connected by fiber optic cable(s), the count of which varies depending upon the DDC mode to provide communications to and from the transmitter. The transmitter unit connects to the CPU with supplied DVI-D cables (and audio, serial & network cables in A/V+ and A/N+ models). The receiver unit provides an interface to the monitor(s) (and audio, serial & network devices in A/V+ and A/N+ models).
Each Transmitter (TX) features a video input and local video output which can be used for DDC modification and for displaying video at the source. The TX also has fiber connectors used for transferring video and data to the Receiver. (For an
Automatic Fail-Over option
, see on page 47 for more details.) Status LEDS and DDC Mode buttons are provided for system configuration.
Each Receiver (RX) features two video outputs. DVI to Display DDC is the primary output and DVI to Display is an auxiliary output. The RX has fiber connectors used for transferring data to the TX and for receiving video and data from the TX. Status LEDS and DDC Mode buttons are provided for system configuration.
permit the
Appendix D,
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
4
The Future of Access and Control
Velocity
dvi
Digital Video Extender-3
The Future of Access and Control
Transmitter: VEL-000M03-LCTX Receiver: VEL-000M03-LCRX
The Future of Access and Control
Velocity
dvi
Digital Video Extender-6
The Future of Access and Control
Transmitter: VEL-000M06-LCTX Receiver: VEL-000M06-LCRX
Velocitydvi Digital Video Extender-33 VEL-000M33-LCTX/RX
®
STATUSSTATUS STATUS
Velocity
Digital Video Extension System Transmitter
Powered by
MRTS Technology
dvi
- 33
Velocitydvi Digital Video Extender-63 VEL-000M63-LCTX/RX
®
STATUSSTATUS STATUS
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
Velocity
Digital Video Extension System
Transmitter
Powered by
MRTS Technology
dvi
- 63
2 0 1 3
Page
5
1.3. The VelocityDVI-3 and -6 Extender Models
VEL-000S03-SCRX VEL-000S03-SCTX
VOP-S05 VEL-000S06-SCRX VEL-000S06-SCTX
VOP-S08 VEL-000M03-LCRX
VEL-000M03-LCTX VEL-000M03-SCRX VEL-000M03-SCTX VEL-000M03-STRX VEL-000M03-STTX
VEL-000M33-LCRX VEL-000M33-LCTX VEL-000M33-SCRX VEL-000M33-SCTX VEL-000M33-STRX VEL-000M33-STTX
VEL-AV0S03-SCRX VEL-AV0S03-SCTX VEL-AV0S03-NKRX VEL-AV0S03-NKTX
VOP-S05 VELOCITY 3 AV+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM, VOP-S11 VELOCITY 3 AV+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM,
VEL-AV0M03-LCRX VELOCITY 3 VEL-AV0M03-LCTX VELOCITY 3 VEL-AV0M03-SCRX VELOCITY 3 VEL-AV0M03-SCTX VELOCITY 3 VEL-AV0M03-STRX VELOCITY 3 VEL-AV0M03-STTX VELOCITY 3 VEL-AV0M03-NKRX VELOCITY 3
VELOCITY 3 optics option for TX or RX, SINGLEMODE, DUAL FIBERS, 10KM
VELOCITY 6 optics option for TX or RX, SINGLE MODE, 3 FIBERS, 10KM
VELOCITY 3 DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SINGLE MODE, SC/APC
VELOCITY 3 DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT, DDC,
SINGLE MODE, SC/APC
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI OUTPUT,
DDC, SINGLE MODE, SC/APC
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI OUTPUT,
DDC, SINGLE MODE, SC/APC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, LC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, LC
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, SC VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, SC VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, ST
VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, ST
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, LC
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, LC
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, SC 3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, SC 3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, RX, ST
3-in-1 VELOCITY 3, SINGLE LINK DVI, DDC, MULTIMODE, TX, ST
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, SC/APC
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, SC/APC
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, NEUTRIK LC
VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, NEUTRIK LC
SC/APC NEUTRIK LC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
6
VEL-AV0M03-NKTX VELOCITY 3
A/V+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI MODE, TX, NEUTRIK
VOP-M04 VELOCITY 3 AV+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M, or 350M
or 1000M, LC or NEUTIK LC
VOP-M01 VELOCITY 3 AV+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M or 350M or
1000M, SC or ST
VEL-AN0S03-SCRX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, SC/APC
VEL-AN0S03-SCTX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, SC/APC
VEL-AN0S03-NKRX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE, RX, NEUTRIK LC
VEL-AN0S03-NKTX
VELOCITY 3 A/N+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT,
DDC, SERIAL, AUDIO, SINGLE MODE. TX, NEUTRIK LC
VOP-S05 VELOCITY 3 A/N+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM,
SC/APC
VOP-S11 VELOCITY 3 A/N+ optics option for TX or RX, SINGLE MODE, DUAL FIBER, 10KM,
NEUTRIK LC
VEL-AN0M03-LCRX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
VEL-AN0M03-LCTX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
VEL-AN0M03-SCRX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
VEL-AN0M03-SCTX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
VEL-AN0M03-STRX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
VEL-AN0M03-STTX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
VEL-AN0M03-NKRX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
VEL-AN0M03-NKTX VELOCITY 3
A/N+
DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, NEUTRIK
VOP-M04 VELOCITY 3 A/N+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M, or 350M
or 1000M, LC or NEUTIK LC
VOP-M01 VELOCITY 3 A/N+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M or 350M
or 1000M, SC or ST
VEL-000M06-LCRX
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI OUTPUT,
DDC, MULTI-MODE, RX, LC
VEL-000M06-LCTX
VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-MODE,
TX, LC
VEL-000M06-SCRX
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI OUTPUT,
DDC, MULTI-MODE, RX, SC
VEL-000M06-SCTX
VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-MODE,
TX, SC
VEL-000M06-STRX
VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI OUTPUT,
DDC, MULTI-MODE, RX, ST
VEL-000M06-STTX
VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-MODE,
TX, ST
VEL-000M63-LCRX
3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI
OUTPUT, DDC, MULTI-MODE, RX, LC
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
7
VEL-000M63-LCTX
3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-
MODE, TX, LC
VEL-000M63-SCRX
3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI
OUTPUT, DDC, MULTI-MODE, RX, SC
VEL-000M63-SCTX
3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-
MODE, TX, SC
VEL-000M63-STRX
3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI
OUTPUT, DDC, MULTI-MODE, RX, ST
VEL-000M63-STTX
3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI-
MODE, TX, ST
VEL-AV0S06-SCRX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI
OUTPUT, DDC, SERIAL, AUDIO, SINGLE MODE, RX, SC/APC
VEL-AV0S06-SCTX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI
PORT, DDC, SERIAL, AUDIO, SINGLE MODE, TX, SC/APC
VEL-AV0S06-NKRX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI
OUTPUT, DDC, SERIAL, AUDIO, SINGLE MODE, RX, NEUTRIK LC
VEL-AV0S06-NKTX
VELOCITY 6 A/V+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI
PORT, DDC, SERIAL, AUDIO, SINGLE MODE, TX, NEUTRIK LC
VOP-S08 VELOCITY 6 AV+ optics option for TX or RX, SINGLE MODE, 3 FIBERS, 10KM, SC/APC VOP-S12 VELOCITY 6 AV+ optics option for TX or RX, SINGLE MODE, 3 FIBERS, 10KM, NEURTIK
LC/APC
VEL-AV0M06-LCRX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
VEL-AV0M06-LCTX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
VEL-AV0M06-SCRX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
VEL-AV0M06-SCTX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
VEL-AV0M06-STRX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
VEL-AV0M06-STTX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
VEL-AV0M06-NKRX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
VEL-AV0M06-NKTX VELOCITY 6
A/V+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, NEUTRIK
VOP-M05 VELOCITY 6 AV+ optics option for TX or RX, MULTIMODE, 3 FIBERS, 50M, or 350M or
1000M, LC or NEUTRIK LC
VOP-M02 VELOCITY 6 AV+ optics option for TX or RX, MULTIMODE, 3 FIBERS, 50M or 350M or
1000M, SC or ST
VEL-AN0S06-SCRX
VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI
OUTPUT, DDC, SERIAL, AUDIO, SINGLE-MODE, RX, SC/APC
VEL-AN0S06-SCTX
VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI
PORT, DDC, SERIAL, AUDIO, SINGLE-MODE, TX, SC/APC
VEL-AN0S06-NKRX
VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DUAL DVI
OUTPUT, DDC, SERIAL, AUDIO, SINGLE-MODE, RX, NEUTRIK LC
VEL-AN0S06-NKTX
VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DUAL DVI
PORT, DDC, SERIAL, AUDIO, SINGLE-MODE, TX, NEUTRIK LC
VOP-S08 VELOCITY 6 A/N+ optics option for TX or RX, SINGLE-MODE, 3 FIBERS, 10KM, SC/APC VOP-S12 VELOCITY 6 A/N+ optics option for TX or RX, SINGLE-MODE, 3 FIBERS, 10KM, NEURTIK
LC/APC
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
8
VEL-AN0M06-LCRX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, LC
VEL-AN0M06-LCTX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, LC
VEL-AN0M06-SCRX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, SC
VEL-AN0M06-SCTX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, SC
VEL-AN0M06-STRX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, ST
VEL-AN0M06-STTX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, ST
VEL-AN0M06-NKRX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC,
SERIAL, AUDIO, MULTI-MODE, RX, NEUTRIK
VEL-AN0M06-NKTX VELOCITY 6
A/N+
DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,
SERIAL, AUDIO, MULTI-MODE, TX, NEUTRIK
VOP-M05 VELOCITY 6 A/N+ optics option for TX or RX, MULTI-MODE, 3 FIBERS, 50M, or 350M or
1000M, LC or NEUTRIK LC
VOP-M02 VELOCITY 6 A/N+ optics option for TX or RX, MULTI-MODE, 3 FIBERS, 50M or 350M or
1000M, SC or ST
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
9
1.4. Laser Information
The DVI Extender models
Velocity-3, -6, -33
2. System Features
and
-63
are designed and identified as
Class 1 LASER products.
2.1. General System Features
Thinklogical’s VelocityDVI Extender Systems® are designed for high resolution video extension applications, such as remote projection centers, theaters and assembly halls, and for secure computer installations. The ability to remotely locate the CPU away from the monitor allows more control of your computer environment. It is now possible to position your monitor or projector in any setting from office to lecture hall to boardroom while keeping the computer secure in a remote, controlled location.
Each DVI Extender system includes the following features:
Supports one Single-Link (System-3) or one Dual-Link (System-6) video signal.
Supports three Single-Link (System-33) or three Dual-Link (System-63) video signals.
DDC2B compliant
Extends DVI up to 1000 meters (3280 feet) using OM4 multi-mode fiber
Signal transmission via fiber optic cable; no RF interference
Flawless image quality with no frame dropping
Class 1 laser product
Simple plug and play
Small form factor
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
10
2.2. Basic operation
The system transmits video and data information from the Transmitter to the Receiver through fiber L1. The data return path from the Receiver to the Transmitter is fiber L2.
VelocityDVI Extender Overview
2.3 Single Fiber operation, System-3
The unit will operate with a single fiber from the TX to the RX. In this mode of operation the TX can transmit video and status LED information to the RX. The RX cannot send any information to the TX. In this mode the RX buttons are inoperative. Also, DDC information can only be gathered from the TX local port or the Thinklogical default EDID table.
2.4 Dual Fiber Operation, System-3
In this mode video information is transmitted from the TX to the RX over fiber L1. Fiber L2 is used as a data return path from the RX to the TX. Providing a back channel from the RX to the TX allows the RX to modify DDC configuration via the Acquire and Select buttons and allows the RX to send DDC information to the TX. DDC information exchange allows the PC to gather information about the connected monitor to determine the display properties.
System-6 operates in Dual-fiber or Triple-fiber operation. In dual-fiber operation, fibers L1 and L3 are used to transmit data and video from the TX to the RX and in three-fiber mode, fiber L2 transmits data from the RX back to the TX.
2.5 Fiber Operation, System-6
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
11
2. 6 Technical Specifications (Systems-3, -6, -33 and -63)
Technical Specifications (Systems-3, -6, -33, -63)
Video Resolution
Panel Connections
Operating Temperature
and Humidity
Storage Temperature
Indicators
Weight
Dimensions
Vel-3:
Any single-link DVI resolution
Vel-6:
Any single-link or dual-link DVI resolution
Transmitter
Video DVI-D (2) Power 2.5 mm power connector Fiber Connections ST, SC, LC or Neutrik®
Receiver
Video DVI-D (2) Power 2.5 mm power connector Fiber Connections ST, SC, LC or Neutrik®
0-50 o C (32-122o F, 5-95% RH, non-condensing)
-20 to 70o C (-4 to 158o F)
LEDs on each DVI Extender unit:
Front: Rear:
Power, Connection Status
DDC Modes - Local, Remote
<1 lb. (0.45 kg) each (Vel-3, Vel-6) 4 lb. (1.81 kg) each (Vel-33, Vel-63)
See page 30.
Shipping Weight
Optical Cable
Optical Distance
Supply Voltage
Power Consumption
DC Adapter AC/DC adapter, universal input 90-264 VAC (supplied, Vel-3, -6)
DB9 to RJ45 Adapters
Copper Video Cables
4 lb. (1.81 kg) pair (Vel-3, Vel-6) 13 lb. (5.89 kg) pair (Vel-33, Vel-63)
Sys-3 = 2 fibers, Sys-33 = 6 fibers Sys-6 = 3 fibers, Sys-63 = 9 fibers (available, not supplied)
Up to 350 meters using 50/125um, type OM2 Up to 1000 meters using 50/125um, type OM4 Up to 10/40/80 kilometers using 9/125um (Optics available)
+5.0 VDC (Vel-3, Vel-6) 90-264 VAC (Vel-33, Vel-63)
6 watts per unit (Vel-3, Vel-6) 20 watts per unit (Vel-33, Vel-63)
With AV+ models only:
DB9M to RJ45 (ADP-000019-R) DB9F to RJ45 (ADP-000025-R)
CBL000009-002MR Single-link DVI-D Male to Male, 2 meters
1 each, Vel-3 3 each, Vel-33
CBL000023-002MR Dual-link DVI-D Male to Male, 2 meters
1 each, Vel-6 3 each, Vel-63
Compliance Approvals for US, Canada, and European Union
Warranty
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
12 months from date of shipment. Extended warranties available at time of purchase.
2 0 1 3
Page
12
2.7 Velocity Unbalanced Audio Specifications
3. Installing DVI Extenders
All physical connections to these products use industry-standard connectors.
It is recommended that you securely mount each VelocityDVI chassis before installing the cabling and power sources.
Appendix A: Installation Overview on pages 39-44 Appendix B: DVI Extender Mounting on page 45 Appendix C: RJ-45 Adapter Pin-outs on page 46
Please refer to the following appendices at the back of this manual:
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Page
13
3 . 1 AC Power
Two wall pack AC/DC adapters (PWR-000022-R) are included with the VelocityDVI-3 and VelocityDVI-6 models. The AC wall pack has a universal power rating of 100-240VAC, 50-60Hz and also has interchangeable wall plug adapters for various international AC power receptacles (below).
+5VDC
Continuous Short Circuit Protection
Over Voltage Protection
Conductive EMI Meets CISPR/FCC Class B high efficiency, 75% Typical
International Receptacle Adapters
International Receptacle Adapters for the PWR-000022-R +5VDC Power Supply
V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,
2 0 1 3
Loading...