Thinklogical Remote Power Distribution 12 User Manual

®
High Reliability, Rack-Space Saving
Power Distribution Unit
with Twelve +5VDC Outputs
Thinklogical, LLC®
100 Washington Street
Milford, Connecticut 06460 U.S.A.
Telephone: 1-203-647-8700
Fax: 1-203-783-9949
Copyright Notice
Copyright Notice
Copyright NoticeCopyright Notice
Copyright © 2014. All rights reserved. Printed in the U.S.A.
Thinklogical, LLC® 100 Washington Street Milford, Connecticut 06460 U.S.A. Telephone: 1-203-647-8700
All trademarks and service marks are property of their respective owners.
Subject: Power Distribution Unit-12 (PDU12) Product Manual Release: Initial Release, May, 2014
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 2
Table of Contents
PREFACE 4
About Thinklogical 4 Note and Warning Symbols 5
1.0. INTRODUCTION 5
1.1. Product Overview 5
2.0. SYSTEM FEATURES 7
2.1. General System Features 7
2.2. Supplied Cords and Cables 7
2.3. Dry Contact Alarm 8
3.0. PDU-12 TECHNICAL SPECIFICATIONS 9
4.0. REGULATORY & SAFETY COMPLIANCE 10
4.1. Safety Requirements 10 Symbols Found on the Product 10 Regulatory Compliance 10 North America 10 Australia & New Zealand 10 European Union 10 Standards with which Our Products Comply 10
4.2. Supplementary Information 11 Product Serial Number 11 Connection to the Product 11
5.0. HOW TO CONTACT US 11
5.1. Customer Support 11 Website 12 Email 12 Telephone 12 Fax 13
5.2. Product Support 13
5.2.1. Warranty 13
5.2.2. Return Authorization 13 Our Address 13
APPENDIX: PDU-12 Quick Start Guide 14
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 3
PREFACE
About Thinklogical
Thinklogical is the leading manufacturer and provider of fiber optic KVM, video, audio, and peripheral extension and switching solutions used in video-rich, big-data computing environments.
Thinklogical offers the only fiber optic KVM matrix switches and routers in the world that are accredited to The Common Criteria, EAL4 and TEMPEST.
Governments, entertainment, scientific and industrial customers worldwide rely on Thinklogical’s products and solutions for security, high performance, continuous operation and ease of integration. Thinklogical products are designed and manufactured in the USA and are certified to the ISO 9001-2008 standard.
Thinklogical is headquartered in Milford, Connecticut and is privately held by Riverside Partners, LLC, Boston, MA (http://www.riversidepartners.com). For more information about Thinklogical products and services, please visit www.thinklogical.com.
Follow Thinklogical on LinkedIn at http://www.linkedin.com/company/thinklogical and on Facebook at http://www.facebook.com/ThinklogicalUSA
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 4
Note and Warning Symbols
Throughout this manual you will notice certain symbols that bring your attention to important information. These are Notes and Warnings. Examples are shown below.
Note: Important Notes appear in blue text preceded by a yellow exclamation point symbol, as shown here.
A note is meant to call the reader’s attention to helpful information at a point in the text that is relevant to the subject being discussed.
Warning! All Warnings appear in red text, followed by blue text, and
preceded by a red stop sign, as shown here.
A warning is meant to call the reader’s attention to critical information at a point in the text that is relevant to the subject being discussed.
1.0. Introduction
PDU-12 Power Distribution Unit (Part Number PDU-000012)
H: 1.72” (43.69 mm) x D: 10.52” (267.08mm) x W: 17.49” (444.29 mm)
1.1. Product Overview
The PDU-12 is a one rack-unit device that provides twelve +5 volt outputs via the rear panel. Each unit contains two redundant, hot swappable AC-DC power supplies that are capable of load sharing. These supplies plug into the rear of the chassis and have removable AC line cords.
The rear panel features twelve DC Locking Power Jacks with a .100” diameter center pin. Each +5 volt output is capable of sourcing +5 volts ±.25volts at a maximum of 4 amps.
PDU-12 Power Distribution Unit, rear panel
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 5
The PDU-12 can provide +5 volt power to, but not limited to, the following Thinklogical products:
VelocityDVI Extension System-3, -3R, -3A/V+, -3R AV+
VelocityDVI Extension System-6, -6A/V
Camera Fiber-Link Series
USB 2.0 Fiber Optic Extender
SDI Xtreme 3G, 3G+
PDU12 Power Distribution Unit
Power Supply Switch:
Up to twelve
+5VDC Outputs
l = ON, O = OFF
USB 2.0 Fiber Optic Extender
SDIXtreme 3G+
Fiber Optic Extender
AC Source
Voltage IN
Camera Fiber-Link-3000
VelocityDVI Extension System-3A/V+
Typical PDU-12 +5VDC power application
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 6
2.0. System Features
2.1. General System Features
1 RU 19” rack mountable unit (19.03” [483.46 mm] wide with mounting brackets)
Sturdy housing allows desktop stacking of units. (Allow min. 2” between stacks.)
Two redundant, hot-swappable, load sharing power supply modules with internal
cooling fans*
Each output can source +5VDC +/-.25VDC at a maximum of 4 amps
Dry contact alarm for system monitoring
Front panel LEDs for fan/power status reporting
Twelve 6’ DC locking power connector cables included
Optional DC cable with one Mini XLR connector for the SDIXtreme 3G is also available
Fully compliant with US, Canadian and European Regulatory Agency requirements
*Although the unit can run with only one power supply during system de-bug or reconfiguration, it is recommended that both supplies be used for continuous operation.
2.2. Supplied Cords and Cables
AC line cords are also available in Euro (PWR-000005) and UK (PWR-000013) configurations as specified by the customer. For SDIXtreme applications, please order CBLA000051 +5VDC cable.
Domestic DC Power Cord, 6 Feet (PWR-000006-R) Qty. 2
+5VDC cable, 6 feet (CBLA000050) Qty. 12
+5VDC +5VDC
+5VDC cable, 6 feet (CBLA000051) Optional
+5VDC Mini XLR, +5VDC
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 7
2.3. Dry Contact Alarm
Dry Contact Alarm
The dry contact alarm is located on the unit’s rear panel. The relay is energized when there is an alarm condition, such as over temperature or power regulation.
The dry contact alarm is a Form C contact with the following ratings:
Nominal switching capacity: 1A, 30V DC Max. switching power: 30W DC
(Rear Panel)
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 8
3.0. PDU-12 Technical Specifications
PDU-12 DC Power Distribution Unit
2 AC/DC Power
Supply Voltage
Source Voltage +5 volts ±.25volts at a maximum of 4 amps.
Dimensions
Rear Panel
Connectors
Dry Contact Alarm
Front Panel LEDs
100 – 240 VAC at a frequency of 50 - 60Hz.
Height: 1.72” (43.69 mm) Depth: 10.52” (267.08 mm) Width: 17.49" (444.29 mm) Width (with mounting brackets): 19.03" (483.46 mm)
(Tolerance: ± .039"; 1 mm) 12 DC Locking Power Jacks (with .100 inch diameter center pin)
Dry Contact Alarm
1 Green/Red LED Reports:
Power Supply 1 Fan status Power Supply 1 Power status Power Supply 2 Fan status Power Supply 2 Power status +5 VDC output 1-12 Power status
1 green/red LED for Power Supply 1 fan status 1 green/red LED for Power Supply 1 power status 1 green/red LED for Power Supply 2 fan status 1 green/red LED for Power Supply 2 power status
12 green LEDs to indicate the status of each of the +5 VDC outputs.
PWR-000006-R AC 3-wire line cord, 6FT (2)
Electrical Cables
Operating Temp
and Humidity
Weight
Shipping Weight
Compliance Approvals for US, Canada, and European Union
Warranty 12 months from date of purchase. Extended warranties available.
CBLA000050 DC power cable w/ locking connectors, 6FT (12) CBLA000051 DC power cable w/ one mini XLR connector, one
locking connector, 6 FT (optional; supplied as required)
0° to 50°C (32° to 122 °F), 5% to 95% RH, non-conde nsing
7.5 lb (3.4 kg) 15 lb (6.8 kg)
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 9
4.0. Regulatory & Safety Compliance
4.1. Safety Requirements
Symbols found on the product
Markings and labels on the product follow industry-standard conventions. Regulatory markings found on the products comply with domestic and many international requirements.
Regulatory Compliance
Thinklogical’s® products are designed and made in the U.S.A. PDU Series products have been tested by a certified testing laboratory and found to be compliant with the following standards (both domestic USA and many international locations):
North America
Safety
ANSI/UL60950-1: 1st Edition (2003) CAN/CSA C22.2 No. 60950-1-03
Electromagnetic Interference
FCC CFR47, Part 15, Class A Industry Canada ICES-003 Issue 2, Revision 1
Australia & New Zealand
This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.
European Union Declaration of Conformity
Manufacturer’s Name & Address: Thinklogical, LLC®
100 Washington Street Milford, Connecticut 06460 USA
These products comply with the requirements of the Low Voltage Directive 72/23/EEC and the EMC Directive 89/336/EEC.
Standards with Which Our Products Comply
Safety
CENELEC EN 60950-1, 1st Edition (2001)
Electromagnetic Emissions
EN55022: 1994 (IEC/CSPIR22: 1993) EN61000-3-2/A14: 2000 EN61000-3-3: 1994
Electromagnetic Immunity
EN55024: 1998 Information Technology Equipment-Immunity Characteristics EN61000-4-2: 1995 Electro-Static Discharge Test EN61000-4-3: 1996 Radiated Immunity Field Test EN61000-4-4: 1995 Electrical Fast Transient Test EN61000-4-5: 1995 Power Supply Surge Test EN61000-4-6: 1996 Conducted Immunity Test EN61000-4-8: 1993 Magnetic Field Test EN61000-4-11: 1994 Voltage Dips & Interrupts Test
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 10
4.2. Supplementary Information
The following statements may be appropriate for certain geographical regions and might not apply to your location.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigencies du Règlement sur le matérial brouilleur du Canada.
Warning! This is a Class A product. In a domestic environment, this product may
cause radio interference, in which case the user may be required to take corrective
measures. Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications in which case the user may be required to take adequate corrective measures at their own expense.
Note: This Class A digital apparatus complies with Canadian ICES-003 and has been
verified as being compliant within the Class A limits of the FCC Radio Frequency Device Rules (FCC Title 47, Part 15, Subpart B CLASS A), measured to CISPR 22: 1993 limits and methods of measurement of Radio Disturbance Characteristics of Information Technology Equipment.
Note: magnetic fields
The user may notice degraded audio performance in the presence of electro-
.
Product Serial Number
Q-Series products have a unique serial number, which includes a date-code, printed on an adhesive label that is affixed to the unit. The format for the date-code is 2 digits for the week, 2 digits for the year, plus two to four digits for a unique unit number. For example, 0814125 indicates the unit was built on the 8th week of 2014, and is unit number 125.
Connection to the Product
Connections and installation hardware for our products use industry-standard devices and methods. All wiring connections to the customer equipment are designed to minimize proprietary or customized connectors and cabling. Power connections are made with regionally appropriate power cords and approved methods.
5.0. How to Contact Us
5.1. Customer Support
Thinklogical® is an engineering company and you will receive the information you require directly from our most knowledgeable engineers.
We believe that the first line of support comes from the design
engineers that developed each particular product.
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 11
Therefore, your questions or issues will be handled promptly by our in-house engineers who are most familiar with your products.
Website
Check out our website for current product offerings, support information and general information about all of the products we offer.
Our internet website offers product information on all current systems, including technical specification sheets and installation guides (for viewing online or for download), product diagrams showing physical connections and other information you might need.
Internet: www.thinklogical.com
Note: Most online documents are stored as Adobe Acrobat “PDF” files. If you do not have
the Adobe Acrobat reader needed to view PDF files, visit www.adobe.com for a download.
Email
Thinklogical® is staffed Monday through Friday from 8:30am to 5:00pm, Eastern Time Zone. We will try to respond to your email inquiries promptly, use the following email addresses for your different needs:
info@thinklogical.com – Information on Thinklogical® and our products. sales@thinklogical.com – Sales Department - orders, questions or issues. support@thinklogical.com – Product support, technical issues or questions, product
repairs and request for Return Authorization.
Telephone
Product & Customer Support: 1-203-647-8700 US Commercial & Canada Sales: 1-203-647-8769
US Federal Government Sales: 1-203-647-8716 Toll Free in the Continental US: 1-800-291-3211 International Sales (Europe, Middle East, Africa): 1-203-647-8704
International Sales (Asia Pacific, Central & Latin America): 1-203-647-8734 Fax: 1-203-783-9949
Please contact our expert sales staff in Milford, CT. We are here Monday through Friday from 8:30am to 5:00pm, Eastern Time Zone. We’ll provide a representative’s direct dial phone number when you call.
If leaving a voice message, please provide a preferred time to call back so we may reach you at your convenience.
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 12
Our switchboard attendant will direct your call during regular business hours. We have an automated attendant answering our main telephone switchboard after regular business hours and holidays. You can leave voice messages for individuals at any time.
Fax
Our company facsimile number is 1-203-783-9949. Please indicate the nature of the fax on your cover sheet and provide return contact information.
5.2. Product Support
Thinklogical’s® support personnel are available Monday through Friday from 8:30am to 5:00pm, Eastern Time Zone. If your application requires assistance at some time outside of our normal business hours, please contact us beforehand and we will do our best to make arrangements to help you with your Thinklogical® products.
5.2.1. Warranty
Thinklogical, LLC® warrants this product against defects in materials and workmanship for a period of one year from the date of delivery. Thinklogical, LLC warranties.
Note: Thinklogical, LLC® products carry a one year warranty, with longer term available at
time of purchase on most products. Please refer to your product invoice for your products Warranty Terms & Conditions.
®
and its suppliers disclaim any and all other
Defect remedy shall be the repair or replacement of the product, provided that the defective product is returned to the authorized dealer within a year from the date of delivery.
If you wish to return your device, contact the Thinklogical, LLC® authorized dealer where you purchased the device, or if you purchased directly, call Thinklogical, LLC® at 1-800-291-3211 (USA).
5.2.2. Return Authorization
In the event you must return a product to Thinklogical® directly, please contact Customer Support at 1-800-291-3211 or 1-203-647-8700. Customer Support will ask you to describe the problem and will
issue you a Return Merchandise Authorization number (RMA#). Pack the device in its original box, if possible, and return it with the RMA# printed on the outside of the box.
Note: DO NOT return a product to Thinklogical® without a Return Material Authorization.
Our Address
If you have any product issues or questions or need technical assistance with your Thinklogical® system, please call us at 1-800-291-3211 (USA only) or 1-203-647-8700 and let us help. If you need to write us or return a product, please use the following address: Return address for products with Return Material Authorization:
Attn: RMA# 100 Washington Street Milford, CT 06460 USA
Thinklogical, LLC
®
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 13
Appendix: PDU-12 Quick Start Guide
P D U - 1 2 P r o d u c t M a n u a l ,
M a y , 2 0 1 4
Page 14
Loading...