Thermeau TH-200 User Manual

0 (0)

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP

Owner’s Manual

PRINTED IN CANADA

Thermeau TH-200 User Manual

Table of contents

Introduction

3

General Safety Instructions

5

Thermeau Models’ Specifications

7

Installation Instructions

 

Location

8

Water piping

9

Electrical

10

Bonding

11

Bonding and plumbing step-by-step instructions

11

Electrical Connections

12

Electrical Diagrams

13

Service Analyzer Control

14

Electronic Temp. Controls

14

Initial Startup

17

Meaning of Display Codes

18

Troubleshooting

19

Requesting Assistance or Service

21

Maintenance

22

Winterizing

22

Pool Heat Pump Warranty

23

2

Owner’s manual

 

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP

Thank you for buying

an THERMEAU pool heat pump.

The THERMEAU pool heat pump is a self-contained unit designed specifically for pool heating. Each component has been selected with care to achieve a high-quality product in an effort to exceed all industry standards.

All THERMEAU pool heat pumps have a Scroll compressor, an electronic board with service analyzer, a titanium heat exchanger tube warranted for 10 years against corrosion. All components are of superior quality, which presents you with an effective, state-of-the-art technology heat pump.

In general, compared to other types of pool heaters, such as gas or oilfired, the THERMEAU pool heat pump has a lower heating capacity on a BTU/hr basis. Therefore, it needs to operate for a longer time to accomplish the desired results. Occasionally, it may be necessary to run the heat pump for up to 24 hours per day. However, this should not be of concern to the owner because the heater is designed to operate continuously. What’s more, despite continuous operation, it will still heat the pool far more economically than other types of heaters.

Owner’s manual

3

 

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP

Please read carefully

Whenever you call to request service for your heater, you must know your complete model and serial numbers. You can find this information on the name plate located on the right side of your heater.

Please also record the purchase date of your device and your dealer’s name, address, and telephone number.

Model Number_____________________________________________________

Serial Number______________________________________________________

Purchase Date_ ____________________________________________________

Dealer Name_______________________________________________________

Dealer Address_____________________________________________________

Dealer Phone_ _____________________________________________________

Keep this book and the sales slip together in a safe place for future reference.

Service can now be obtained by calling these phone numbers.

CANADA AND USA: 1 418 661-2222

4

Owner’s manual

 

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP

General Safety Instructions

We care for our customers

We have provided important safety messages in this manual and on your heater. Always read and obey all safety messages.

IMPORTANT

?The IMPORTANT sign calls attention to a note that provides important information or information essential to the completion of a task.

CAUTION

The CAUTION sign denotes a hazard. It calls attention to an operating

!procedure, practice, or the like, which, if not correctly performed or adhered to, could result in material damage, particularly to the product, up to the destruction of part or all of the product.

WARNING

The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury or injury to a third party. These signs are rare, but are extremely important.

Owner’s manual

5

 

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP

CAUTION

All electrical connections must be done by a qualified electrician and according to the local electrical codes. Always cut off the unit’s main

!power whenever the access panel is open or removed. Always install the machine outdoors (unless otherwise approved by the manufacturer), while respecting the minimal clearances needed for proper operation and heating.

CAUTION

!Proper pool chemistry is vital to the life of your heater. Pay particular attention to the total alkalinity and TDS. It is highly recommended that you have your pool chemistry checked often by an independent pool store.

Water quality standards that must be strictly observed

Description

Normal Range

Verification

 

 

 

pH level

7.2 to 7.8

Once/week

 

 

 

Chlorine concentration

1.0 to 3.0 ppm

Once/2-3 days

 

 

 

Total alkalinity

80 to 100 ppm

Once/2-3 weeks

 

 

 

Total dissolved solids (TDS)

Below 1600 ppm (fresh water)

Once/month

 

 

 

 

Below 3000 ppm (salt water)

Once/month

 

 

 

Calcium hardness

200 to 300 ppm

Once/month

 

 

 

6

Owner’s manual

 

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP

A robust and reliable product line

ModEl

TH-150

TH-150-3

TH-200

TH-200-3

TH-200-3A

Btu 80 water /

 

 

 

 

 

80 air /

142,000 – 6

150,000 – 6.2

185,000 – 5.6

200,000 – 6.1

200,000 – 6.1

80 % humidity*

 

 

 

 

 

Btu 80 water /

 

 

 

 

 

80 air /

132,000 – 5.9

142,000 – 6

175,000 – 5.5

185,000 – 5.9

185,000 – 5.9

63 % humidity** - COP

 

 

 

 

 

Btu 80 water /

 

 

 

 

 

50 air /

90,000 – 4

95,000 – 4.1

116,000 – 4

128,000 – 4.3

128,000 – 4.3

63 % humidity** - COP

 

 

 

 

 

Compressor ( HP )

7

7.5

2x5

10

10

Compressor type

Scroll

Scroll

Scroll

Scroll

Scroll

Heat exchanger

Titanium / PVC

Titanium / PVC

Titanium / PVC

Titanium / PVC

Titanium / PVC

Heating range

Up to

Up to

Up to

Up to

Up to

(°F / °C)

104°F / 40°C

104°F / 40°C

104°F / 40°C

104°F / 40°C

104°F / 40°C

Voltage Hz/Ph

208-240 60/1

208-240 60/3

208-240 60/1

208-240 60/3

575-600 60/3

Required breaker

60

40

60

60

30

Minimum circuit ampacity

42.5

36.9

47

44

16.8

(MCA)

 

 

 

 

 

Plumbing connections

2’’

2’’

2’’

2’’

2’’

Water Flow (GPM)

60 to 125

60 to 125

60 to 125

60 to 125

60 to 125

 

H: 40

H: 40

H: 48

H: 48

H: 48

Dimensions in inches

W: 33

W: 33

W: 33

W: 33

W: 33

 

D: 39

D: 39

D: 39

D: 39

D: 39

Hot Gas Defrost

Yes

Yes

Yes

Yes

Yes

Weight (lb)

304

305

445

375

375

 

 

 

 

 

 

* Tests performed without taking into account the AHRI 1160 standard. ** Tests performed with the AHRI 1160 standard.

Owner’s manual

7

 

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP

Installation Instructions

Location

The placement of the pool heater is very important in keeping installation costs to a minimum while providing for maximum efficiency of operation, as well as allowing adequate access for service and maintenance.

The THERMEAU pool heat pump is designed for outdoor installation and should not be installed in a fully enclosed area, such as a shed, garage, etc., unless ventilation is provided to ensure adequate air exchange for proper operation. Recirculation of cold discharged air back into the evaporator coil will greatly reduce unit heating capacity and efficiency.

The unit should be located as close as practical to the existing pool pump and filter to minimize water piping. However, do not forget to provide a 18” clearance at the very least all around your heat pump.

Mount the unit on a sturdy base, preferably a concrete slab or a set of blocks. The size of the base should not be less than 40” x 40” (100 cm x 100 cm).

? IMPORTANT

All THERMEAU pool heat pump models feature patented, ultrasilent ventilation systems. Air is pulled through the evaporator coil and discharged through the top grille. A minimum clearance of 48 inches should be allowed above the unit for unrestricted air discharge. The unit must not be installed under a porch. Any side of the unit should be located at least 24 inches from a wall or from any other obstruction for unrestricted air intake and service access.

Fig. 1

8

Owner’s manual

 

CHAuFFE-PIsCINE COMMERCIAL POOl HEAT PumP