THERMEAU S65, TH80, S100, TH65, TH100 Owner's Manual

...
OWNER’S Manual
PRINTED IN CANADA
2
OWNER’S MANUAL
Introduction 3
General Safety Instructions 5
Thermeau Models’ Specifications 7
Location 9
Water piping 10
Multiple Heat Pump Connections 11
Electrical 12
Bonding 12
Bonding and plumbing step-by-step instructions 12
Electrical Connections 13
Electrical Diagrams 14
Service Analyzer Control 15
Electronic Temp. Controls 16
Initial Startup 18
Meaning of Display Codes 19
Troubleshooting 20
Requesting Assistance or Service 22
Maintenance 22
Winterizing 22
Pool Heat Pump Warranty 23
Table of contents
3
OWNER’S MANUAL
Thank you for buying an THERMEAU pool heat pump.
The THERMEAU pool heat pump is a self-contained unit designed specifically for pool heating. Each component has been selected with care to achieve a high-quality product in an effort to exceed all industry standards.
All THERMEAU pool heat pumps have a Scroll
compressor, an electronic board with service analyzer, a titanium heat exchanger tube warranted for 10 years against corrosion. All components are of superior quality, which presents you with an effective, state-of-the-art technology heat pump.
In general, compared to other types of pool heaters, such as gas or oil­fired, the THERMEAU pool heat pump has a lower heating capacity on a BTU/hr basis. Therefore, it needs to operate for a longer time to accomplish the desired results. Occasionally, it may be necessary to run the heat pump for up to 24 hours per day. However, this should not be of concern to the owner because the heater is designed to operate continuously. What’s more, despite continuous operation, it will still heat the pool far more economically than other types of heaters.
4
OWNER’S MANUAL
Service can now be obtained by calling these phone numbers.
CANADA: 1 855 661-9330 USA: 1 855 385-6480
Please read carefully
Whenever you call to request service for your heater, you must know your complete model and serial numbers. You can find this information on the name plate located on the right side of your heater.
Please also record the purchase date of your device and your dealer’s name, address, and telephone number.
Model Number ____________________________________________________
Serial Number _____________________________________________________
Purchase Date ____________________________________________________
Dealer Name ______________________________________________________
Dealer Address ____________________________________________________
Dealer Phone _____________________________________________________
Keep this book and the sales slip together in a safe place for future reference.
5
OWNER’S MANUAL
General Safety Instructions
We care for our customers
We have provided important safety messages in this manual and on your heater. Always read and obey all safety messages.
IMPORTANT
The IMPORTANT sign calls attention to a note that provides important information or information essential to the completion of a task.
CAUTION
The CAUTION sign denotes a hazard. It calls attention to an operating procedure, practice, or the like, which, if not correctly performed or adhered to, could result in material damage, particularly to the product, up to the destruction of part or all of the product.
WARNING
The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury or injury to a third party. These signs are rare, but are extremely important.
?
!
6
OWNER’S MANUAL
CAUTION
All electrical connections must be done by a qualified electrician and according to the local electrical codes. Always cut off the unit’s main power whenever the access panel is open or removed. Always install the machine outdoors (unless otherwise approved by the manufacturer), while respecting the minimal clearances needed for proper operation and heating.
!
CAUTION
Proper pool chemistry is vital to the life of your heater. Pay particular attention to the total alkalinity and TDS. It is highly recommended that you have your pool chemistry checked often by an independent pool store.
!
Water quality standards that must be strictly observed
Description Normal Range Verification
pH level 7.2 to 7.8 Once/week
Chlorine concentration 1.0 to 3.0 ppm Once/2-3 days
Total alkalinity 80 to 100 ppm Once/2-3 weeks
Total dissolved solids (TDS) Below 1600 ppm (fresh water) Once/month
Below 3000 ppm (salt water) Once/month
Calcium hardness 200 to 300 ppm Once/month
7
OWNER’S MANUAL
A robust and reliable product line
Residential
OPERATING
SPEcIfIcATIONS
S65 / TH65 S80 / TH80 S100 / TH100 S125 / TH125 S140 / TH140
Volts 230 230 230 230 230
Hertz 60 60 60 60 60
Phase 1 1 1 1 1
Compressor amps 12.4 A 14.3 A 21.2 A 24.3 A 27.3 A
Fan motor max.
load amps
2,4 A 2,4 A 2,4 A 2,4 A 2,4 A
Fan motor HP 1/3 1/3 1/3 1/3 1/3
Fan motor speed 825RPM 825RPM 825RPM 825RPM 825RPM
Minimum circuit
ampacity
30 A 30 A 40 A 40 A 50 A
Maximum fuse 40 A 50 A 60 A 60 A 70 A
Refrigerant R-410A R-410A R-410A R-410A R-410A
Optimal water flow
rate (GPM)
30 35 40 55 60
Max. water flow
rate (GPM)
100 100 100 100 100
Max. water
temperature
104F 104F 104F 104F 104F
Dimensions (in.) H:34 L:33 D:39 H:34 L:33 D:39 H:34 L:33 D:39 H:34 L:33 D:39 H:34 L:33 D:39
8
OWNER’S MANUAL
A robust and reliable product line
Commercial
MOdEl TH-200 TH-200-3 TH-200-3A
Compressor ( HP ) 2x5 10 10
Compressor type Scroll Scroll Scroll
Heat exchanger Titanium / PVC Titanium / PVC Titanium / PVC
Heating range (°F / °C)
Up to
104°F / 40°C
Up to
104°F / 40°C
Up to
104°F / 40°C
Voltage Hz/Ph 208-240 60/1 208-240 60/3 575-600 60/3
Required breaker 60 60 30
Minimum circuit ampacity (MCA)
47 44 16.8
Plumbing connections 2’’ 2’’ 2’’
Water Flow (GPM) 60 to 125 60 to 125 60 to 125
Dimensions in inches
H: 48 W: 33 D: 39
H: 48 W: 33 D: 39
H: 48 W: 33 D: 39
Hot Gas Defrost Ye s Ye s Ye s
Weight (lb) 445 375 375
Loading...