Thermador VCI29CS/01, VCI21CS/02, VCI21CS/01 Installation Guide

Thewma_ow + Ao A=.=,c=.3co.-
Table of Contents
Safety .......................................................... 1
Installation ...................................................... 2
Before You Begin .................................................................... 2
Installation Procedure ................................................................. 5
Service ......................................................... 6
Before Calling Service ................................................................. 6
Questions?
1-800-735-4328
5551 McFadden Ave.
Huntington Beach, CA 92649
We look forward to hearing from you!
Safety
Safety
__ READ AND SAVE THESE INSTRUCTIONS
Important Safety Instructions
Appliance Handling Safety
Safety Codes and Standards
IMPORTANT SAFETY INSTRUCTIONS
WARNING: If the information in this manual is not followed exactly, fire or shock may result causing property damage or personal injury. WARNING: Do not repair or replace any part of the appliance unless specifi- cally recommended in the manuals. Improper installation, service or mainte- nance can cause injury or property damage. Refer to this manual for guidance. All other servicing should be done by a qualified technician.
Unit is heavy and requires at least two people or proper equipment to move.
Hidden surfaces may have sharp edges. Use caution when reaching behind or under appliance.
This appliance complies with one or more of the following Standards:
1) UL 858, The Standard for the Safety of Household Electric Ranges
2) UL 923, The Standard for the Safety of Microwave Cooking Appliances
3) UL 507, The Standard for the Safety of Electric Fans
4) ANSI Z21.1-2000, The American National Standard for Household Cook-
ing Gas Appliances
5) CAN/CSA-C22.2 No. 113-M1984 Fans and Ventilators
6) CAN/CSA-C22.2 No. 61-M89 Household Cooking Ranges
It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.
Electric Safety
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of electric shock.
Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.
For appliances equipped with a cord and plug, do not cut or remove the ground prong. It must be plugged into a matching grounding type receptacle to avoid electrical shock. If there is any doubt as to whether the wall recepta- cle is properly grounded, the customer should have it checked by a qualified
electrician.
If required by the National Electrical Code (or Canadian Electrical Code), this appliance must be installed on a separate branch circuit.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
Installer - show the owner the location of the circuit breaker or fuse. Mark itfor easy reference.
English 1
,_ Safety
Before installing, turn power OFF at the service panel. Lock service panel to prevent power from being turned ON accidentally.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. Ifyou have
questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Be sure your appliance is properly installed and grounded by a qualified tech- nician. Installation, electrical connections and grounding must comply with all applicable codes.
Ventilation Safety
Related Equipment Safety
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire- rated construction.
b) Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori-
ties.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
Remove all tape and packaging before using the appliance. Destroy the pack- aging after unpacking the appliance. Never allow children to play with packag- ing material.
Never modify or alter the construction of the appliance. For example, do not remove leveling legs, panels, wire covers or anti-tip brackets/screws.
CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
WARNING: To reduce the risk of fire, use only metal ductwork.
Installation
Before You Begin
Tools and Parts Needed
Parts Included
English 2
1. Custom Ventilation Hood and Chimney Assembly
2. Ductwork as necessary (style varies)
3. Duct Tape
4. Phillips Head Screwdriver
1. Filters(2)
2. Halogen bulbs (2, installed)
3. Screws, Flat Phillips 3.5 x 15 cm (4) Note: You may use Flat Phillips 6 x 5/8 in. screws as a substitute.
Installation
4. OneWayDamper
Ifpartsaremissingordamaged,callthenumberorwritetotheaddresslisted insidethefrontcover.
General Information
Overall Dimensions
The ventilation unit is designed for installation inside a custom-built hood and chimney assembly. It is for ducting to the outside; It cannot be used in conjunction
with a recirculation unit.
Installation height above cooktop is the user's preference. The lower the hood above the cooktop, the more efficient the capturing of cooking odors, grease, and smoke. This hood has been approved for installations as low as 30" (760 mm) and as high as 36" (900 mm) above the cooktop. The lower height may be inconve- nient for tall people and large cooking vessels.
93/4" 93/4"
:_ (248mm) _ (248mm) ..........
: (_ 6" (150mm)
T
15'
(38imm)
Figure 5: Overall Dimensions - 20 7/8" (53 cm) models
133/4" 133/4"
(348ram) _ (348mm) ..........
' (_ 6" (150ram)
............. i
' 13/8"(35_n 2 1/8"(55 mm)
135/8"
mm)
Figure6: Overall Dimensions - 28 3/4" (73 cm) models
English 3
Installation
Preparation
Electrical Requirements
Mounting Requirements
The unit requires a 120V AC, 60Hz. 15A branch circuit. For future service, install the outlet in an easily accessible location.
The unit must be mounted to the surrounding housing. See "General Information" on page 3 for suggestions for determining hood height.
For best results, install the unit as far up in the housing or hood as possible. This will improve the function of the appliance.
When calculating the load for the housing support system, be sure to include the weight of the ventilation unit. See "Ventilation Unit Weight" on page 4. for unit weight by model.
Table 1: Ventilation Unit Weight
21" (53 cm) 18 1/4 lbs. (8.3 kg) 29" (73 cm) 19 Ibs. (8.7 kg)
For proper performance, the housing must cover the entire cooking surface.
Build housing to correspond with Figure 7: Housing Cutout Dimensions - 20 718" (53 cm) models or Figure 8: Housing Cutout Dimensions - 28 314" (73 cm) mod- els.
English 4
Figure 7: Housing Cutout Dimensions - 20 7/8" (53 cm) models
Installation
Figure8:HousingCutoutDimensions-283/4"(73cm)models
Ducting Recommendations The unit is for ducting to the outside; it cannot be used in conjunction with a recir-
culation unit.
For the most efficient air flow exhaust, use a straight duct run or as few elbows as possible.
Do not use flex ducting. Always use metal ductwork with a diameter of 6" (150 mm).
COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to
minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close
as possible to where the ducting enters the heated portion of the house.
Always install a metal vent cover where the ductwork exits the house.
Make-Up Air: Local building codes may require the use of make-up air systems when using ducted ventilation systems greater than specified CFM of air move- ment. The specified CFM varies from locale to locale. Consult your HVAC profes- sional for specific requirements in your area.
Installation Procedure
Unpack Hood
Prepare ductwork
,_ WARNING: To avoid electrical shock hazard, before installing,
-- power from being switched on accidentally.
Pull hood from outer packaging. Remove and discard all packaging materials. Remove filter and set aside (See Use and Care manual for removal instructions).
Install one-way damper so that the flap opens up (snaps into place). Note: verify that the flap opens up (toward the ceiling) before continuing. If necessary, install thermal break and additional backdraft damper.
switch power off at the service panel and lock the panel to prevent the
English 5
Service
Install Housing
Connect to Ductwork
Connect Electric
Install the Unit
See "General Information" on page 3 for recommended installation height and "Mounting Requirements" on page 4 for information on mounting specifications. Install housing as directed by the manufacturer.
Connect ventilation unit to ductwork in house.
Plug electrical cord into grounded outlet. Before you plug in an electrical cord, be sure all controls are in the OFF position.
Press unit up into housing until plastic clips on front and rear snap into the hous- ing. Install 4 screws through tapholes into housing.
Final Steps
Test The Installation
Service
Before Calling
Service
Figure 9: Install the Unit
Install Filters. See Use and Care manual for detailed instructions.
Test the operation of the blower and the lights.
Note: Be sure to check for backdraft. With the blower on high, close the windows and doors to the area to ensure that fan does not cause back drafting in any outlet vent for another appliance.
See Use and Care Manual for troubleshooting information. Refer to the Warranty in the Use and Care Manual. Please be prepared with the information printed on your product data plate when calling.
Product Data Plate
English 6
The data plate shows the model and serial number. It is located under the filter.
Service
Keepyourinvoiceorescrowpapersforwarrantyvalidationifserviceisneeded.
DataPlate behindfilter
Figure 10: Data Plate Location