RFPLT1000P – FOR USE WITH 1000 CFM REMOTE
BLOWER VTR1030P AND 1300 CFM BLOWER VTR1330P
Page 5 of 12
03 / 18
Page 6
UCVP36RS
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
REMOTE OR INLINE BLOWER INSTALLATION CONTINUED
BLOWER DOWNDRAFT TRANSITIONS
CVTSIDE6
6" round transition allows
for left, right, or rear
venting. Use with inline
and remote blowers, and
ducting with 6" round duct
connections.
CVTSIDE8
8" round transition allows for
left, right, or rear venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
CVTFRONT6
6" front rough-in plate
allows for front venting.
Use with inline and remote
blowers, and ducting with
6" round duct connections.
CVTFRONT8
8" round front plate allows
for front downward venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
CVTSIDE10
10" round transition allows
for left, right, or rear venting.
Use with inline and remote
blowers, and ducting with
10" round duct connections.
CVDUCT2
Rectangular 2 ft. long x 1 7/8
in deep x 19 in wide duct.
CVDUCT2 transition required
to directly connect CVDUCT2
to sides or rear of downdraft
housing. Can be used as an
extension to exhaust through
a cabinet or wall, and can be
cut to modify length. For use
with installation of inline or
remote blower applications
with CVTSIDE6, CVTSIDE8,
and CVTSIDE10.
Page 6 of 12
CVTFRONT10
10" front rough-in plate
allows for front venting.
Use with inline and remote
blowers, and ducting with
10" round duct connections.
CVTRECT2
Transition required to connect CVDUCT2 rectangular
duct to downdraft housing
at left, right, or rear
03 / 18
Page 7
UCVP36RS
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
REMOTE OR INLINE BLOWER INSTALLATION CONTINUED
OPTIONAL ACCESSORIES
RECIRCULATION KIT
UCVRECIRC
Includes 1 charcoal lter
and 1 metal grill vent plate
(blower sold separately).
Use with induction/electric
cooktops only
DOWNDRAFT GAS
COOKTOP SEAL TRIM
KIT UCV36ST
Includes trim, seal, metal
grill, and fasteners.
Required for installations
with 36" gas cooktops.
REPLACEMENT CHARCOAL FILTER
UCVFILTER
Includes 1 replacement charcoal lter for
UCVRECIRC recirculation kit
EXTNCE5
Extends electrical panel cable 5-ft. to connect
remotely located electrical panel to downdraft.
Ability to connect two cables together to make a
10-foot cable.
Page 7 of 12
03 / 18
Page 8
UCVP36RS
103/8"
(264 mm)
123/4"
(324 mm)
123/4"
(324 mm)
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
51/8"
(130 mm)
115/8"
(295 mm)
5"
(127 mm)
3/8
"
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
115/8"
(295 mm)
measurements in inches (mm)
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
FLEXIBLE BLOWER INSTALLATION – FRONT EXHAUST EXAMPLE
REQUIRED BLOWER
OPTIONAL ACCESSORIES
VTD600P – 600 CFM
600 CFM exible blower
can be installed as an
integrated or inline blower
APPLICATION
- Front downward application with space under oor line for ductwork*
- Integral blower with front downward application can be used with
optional recirculation kit*
- Integral blower can rotate for left or right exhaust
- Elbow and ductwork are not included
RECIRCULATION KIT
UCVRECIRC
Includes 1 charcoal lter
and 1 metal grill vent plate
(blower sold separately).
Use with induction/electric
cooktops only
DOWNDRAFT GAS
COOKTOP SEAL TRIM
KIT UCV36ST
Includes trim, seal, metal
grill, and fasteners.
Required for installations
with 36" gas cooktops.
REPLACEMENT CHARCOAL FILTER
UCVFILTER
Includes 1 replacement charcoal lter for
UCVRECIRC recirculation kit
* For only front downward ducting applica tions, elec tric al panel must be remote ly moun ted. Op tional 5' exten sion cable EXTNCE 5 accessor y is available to conne ct remotely placed elect rical
panel to downd raf t. Refer to installation manual.
Page 8 of 12
EXTNCE5
Extends electrical panel cable 5-ft. to connect
remotely located electrical panel to downdraft.
Ability to connect two cables together to make a
10-foot cable.
03 / 18
Page 9
UCVP36RS
BLOWER
SUPPORT LEGS
(4) BOLTS
5.
this time.
B -Installation using inline or remote
blowers - with ducting through front panel opening
CAUTION
alone for support. It may be necessary to add extra support for
6", 8", OR 10” (152MM, 203MM,
103/8"
(264 mm)
123/4"
(324 mm)
123/4"
(324 mm)
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
51/8"
(130 mm)
115/8"
(295 mm)
5"
(127 mm)
3/8
"
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
115/8"
(295 mm)
measurements in inches (mm)
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
FLEXIBLE BLOWER INSTALLATION – FRONT EXHAUST WITH FLEXIBLE BLOWER BELOW FLOOR LINE EXAMPLE
REQUIRED BLOWER
REQUIRED ACCESSORIES
VTD600P – 600 CFM
600 CFM exible blower
can be installed as an
integrated or inline blower
APPLICATION
- Front downward application with space under oor line for ductwork*
- Elbow and ductwork are not included
FRONT
PANEL
OR 254MM) ROUND
REMOTE ROUGH-IN
PLATE (Purchase Separately)
If blower
discharge is
down,
electrical
panel must be
relocated.
CVTFRONT8
8" round front plate allows
for front downward venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
OPTIONAL ACCESSORIES
DOWNDRAFT GAS
COOKTOP SEAL TRIM
KIT UCV36ST
Includes trim, seal, metal
grill, and fasteners.
Required for installations
with 36" gas cooktops.
EXTNCE5
Extends electrical panel cable 5-ft. to connect
remotely located electrical panel to downdraft.
Ability to connect two cables together to make a
10-foot cable.
* For front downw ard duc ting applications, electrical panel mus t be remotely mo unted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed elec trical panel
to down draf t. Refer to installat ion manual.
Page 9 of 12
03 / 18
Page 10
UCVP36RS
103/8"
(264 mm)
123/4"
(324 mm)
123/4"
(324 mm)
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
51/8"
(130 mm)
115/8"
(295 mm)
5"
(127 mm)
103/8"
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
115/8"
(295 mm)
measurements in inches (mm)
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
FLEXIBLE BLOWER INSTALLATION – REAR, LEFT OR RIGHT SIDE EXHAUST EXAMPLE
APPLICATION
- Rear, left or right side exhaust options to preserve precious kitchen storage space or if
ducting is more convenient for these congurations*
- Requires at least 18" of clearance to t the blower and transition
- Blower must be accessible for maintenance
- Elbow and ductwork are not included
Rear Exhaust
REQUIRED ACCESSORYREQUIRED BLOWER
Left Side Exhaust
Right Side Exhaust
* For only front downward ducting applica tions, elec tric al panel must
be remotely mounted. Elect rical panel c an still be remotely mounted
in other exhau st configur ation s if desired. Optiona l 5' extension c able
EXT NCE5 access ory is available to connec t remote ly plac ed elec trical
panel to downd raf t. Refer to installation manual.
NOTE: Some applic ation s may req uire deeper c abine ts. Sid e and
rear exhaust requir e at leas t 18" of clear ance to fit the blower and/or
ductwor k. Refe r to inst allation manual.
VTD600P – 600 CFM
600 CFM exible blower can
be installed as an integrated
or inline blower
OPTIONAL ACCESSORIES
REPLACEMENT CHARCOAL FILTER UCVFILTER
Includes 1 replacement charcoal lter for UCVRECIRC recirculation kit
DOWNDRAFT GAS COOKTOP SEAL TRIM KIT UCV36ST
Includes trim, seal, metal grill, and fasteners. Required for installations
with 36" gas cooktops.
EXTNCE5
Extends electrical panel cable 5-ft. to connect remotely located
electrical panel to downdraft. Ability to connect two cables together
to make a 10-foot cable.
CVTSIDE8
8" round transition allows for left, right, or
rear venting. Use with VTD600P blower as
an inline installation, and ducting with 8"
round duct connections.
RECIRCULATION KIT
UCVRECIRC
Includes 1 charcoal lter and 1 metal grill
vent plate (blower sold separately). Use
with induction/electric cooktops only
Page 10 of 12
03 / 18
Page 11
UCVP36RS
103/8"
(264 mm)
123/4"
(324 mm)
123/4"
(324 mm)
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
51/8"
(130 mm)
115/8"
(295 mm)
5"
(127 mm)
3
/8"
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
115/8"
(295 mm)
measurements in inches (mm)
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
FLEXIBLE BLOWER INSTALLATION – SIDE EXHAUST WITH SLIM 2' RECTANGULAR DUCT EXAMPLE
APPLICATION
- Side exhaust option to preserve precious kitchen storage space
or if ducting is more convenient for this conguration*
- A slim 2' rectangular duct is available to place exible blower in
areas such as unused corner in island or peninsula applications
- Blower must be accessible for maintenance
- Elbow and ductwork are not included
REQUIRED BLOWER
REQUIRED ACCESSORIES
VTD600P –
600 CFM
600 CFM exible
blower can be
installed as an
integrated or
inline blower
*For onl y front downw ard duc ting a pplic ations, electrical panel mus t be remotely mo unted. Electrical panel
can st ill be remotely m ounted in other exhau st configur ation s if desired. Optional 5' extension cable E XTNCE5
accessor y is available to connect rem otely placed el ect rical panel to d owndraft. Refer to installation manual.
NOTE: Some applic ation s may req uire deeper c abine ts. Refer to ins tallation manual.
CVTSIDE8
8" round transition to connect
CVDUCT2 to VTD600P. Use with
VTD600P blower as an inline installation, and ducting with 8" round
duct connections.
CVDUCT2
Rectangular 2 ft. long x 1 7/8 in
deep x 19 in wide duct. CVDUCT2
transition required to directly
connect CVDUCT2 to sides or rear
of downdraft housing. Can be
used as an extension to exhaust
through a cabinet or wall, and can
be cut to modify length. For use
with installation of inline or remote
blower applications with CVTSIDE6,
CVTSIDE8, and CVTSIDE10.
CVTRECT2
Transition required to connect
CVDUCT2 rectangular duct
to downdraft housing at left,
right, or rear
Page 11 of 12
OPTIONAL ACCESSORIES
RECIRCULATION
KIT UCVRECIRC
Includes 1 charcoal
lter and 1 metal
grill vent plate
(blower sold
separately). Use with
induction/electric
cooktops only
REPLACEMENT CHARCOAL FILTER
UCVFILTER
Includes 1 replacement charcoal lter for
UCVRECIRC recirculation kit
DOWNDRAFT GAS COOKTOP SEAL
TRIM KIT UCV36ST
Includes trim, seal, metal grill, and fasteners.
Required for installations with 36" gas
cooktops.
EXTNCE5
Extends electrical panel cable 5-ft. to
connect remotely located electrical panel
to downdraft. Ability to connect two cables
together to make a 10-foot cable.
03 / 18
Page 12
UCVP36RS
EXHAUSTTHROUGHCABINET SIDE
15”
(380)
14 1/2”(368)
3 1/2" (89) x 14 1/4" (362)
EXHAUST OPENING
DECORATIVE
GRILLE
GRILLE
103/8"
(264 mm)
123/4"
(324 mm)
123/4"
(324 mm)
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
51/8"
(130 mm)
115/8"
(295 mm)
5"
(127 mm)
3/8
"
73/8"
(187 mm)
115/8"
(295 mm)
51/4"
(133 mm)
115/8"
(295 mm)
measurements in inches (mm)
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
FLEXIBLE BLOWER INSTALLATION – RECIRCULATION EXAMPLE
REQUIRED BLOWER
REQUIRED ACCESSORIES
VTD600P – 600 CFM
600 CFM exible blower
can be installed as an
integrated or inline blower
APPLICATION
- Allows for non-ducted downdraft installation by eliminating the need
to exhaust to the exterior of the home*
- Recirculation module and metal grill vent plate placement can be
rotated for exible exhaust placement
- Elbow and ductwork are not included
- Use with induction/electric cooktops only
EXHAUST
THROUGH
CABINET
14 1/2”
(368)
SIDE
OPTIONAL ACCESSORIES
REPLACEMENT CHARCOAL FILTER
RECIRCULATION KIT
UCVRECIRC
Includes 1 charcoal lter
and 1 metal grill vent plate
(blower sold separately).
Use with induction/electric
cooktops only
UCVFILTER
Includes 1 replacement charcoal lter for
15”
3 1/2" (89) x 14 1/4" (362)
(380)
EXHAUST OPENING
DECORATIVE
GRILLE
UCVRECIRC recirculation kit
DOWNDRAFT GAS COOKTOP SEAL TRIM
KIT UCV36ST
Includes trim, seal, metal grill, and fasteners.
Required for installations with 36" gas cooktops.
EXTNCE5
Extends electrical panel cable 5-ft. to connect
Measurements
in inches (mm).
EXHAUST
THROUGH
CABINET
BACK
14 1/2"
(368)
remotely located electrical panel to downdraft.
15"
These warranties give you specific legal rights and you may have other rights that vary fro m state to state. Full warrant y and li mited w arranty from date of installation. For co mplete warranty
details, refer to your Use & Care m anual, o r ask you r deale r.
Specifications are for planning p urpo ses only. Refer to in stallation instruct ions an d consult your c ounte rtop supplier prior to making counter opening. C onsul t with a heating a nd vent ilatio n
engineer for your spe cific ventilation re quire ment s. For the most detailed infor mation, refer to installation instruc tions accom panying product or w rite to T hermador in dicating the model
number. Specifications are correct at t ime of pr inting. Ther mador reser ves the right to chang e product sp ecifications or design w ithout notic e. Some models a re cer tified for use in Cana da.
Thermador i s not res ponsible for p roduc ts that are transported from t he U.S. for u se in Canada.
*For front dow nward d ucting applications, elect rical panel must be remotel y mounted.
Optio nal 5' extensio n cable EXTNCE5 accessory is available to con nect remote ly placed
elec tric al pane l to down draf t. Refer to installat ion man ual.
Ability to connect two cables together to make a
10-foot cable.
Page 12 of 12
03 / 18