Thermador UCVM36FS User Manual 2

Page 1
MODELS SHOWN: UCVM36FS 36-INCH DOWNDRAFT WITH CIT365KM INDUCTION COOKTOP184
Page 2
VENTILATION
DOWNDRAFT
If you prefer a concealed look, choose a Thermador Downdraft Ventilation Unit, which offers space efciency when a hood is not preferred. The full-face lter combines a lter with a splatter shield in one easy-to-remove, dishwasher-safe element. Thermador invented the rst retractable downdraft, and was also the rst to introduce a recirculation option for downdrafts— making ventilation possible in any kitchen.
VENTILATION — DOWNDRAFT
1.800.735.4328 | THERMADOR.COM
185
Page 3
DOWNDRAFT
FEATURES & BENEFITS
FULL 13-INCH RISE
With an over 13-inch intake, the UCVM rises well above even the tallest pans. This protects against splatters when cooking and provides better performance in capturing steam and smoke — even from the front burners.
DOWNDRAFT RECIRCULATION OPTION
Downdraft recirculation is now available for island or wall applications. Combine the performance of the UCVM Downdraft with the odor- and grease-capturing lters in the Recirculation Module for the perfect ventilation combination for anywhere in your kitchen.
FULL-FACE FILTERS
Full-face lters combine a lter with a splatter shield in one easy­to-remove, dishwasher-safe element. These lters maximize grease capture without affecting airow.
PLANNING INFORMATION
MODEL OPTIONS
Thermador Downdraft Hoods are available in 30 and 36-inch widths to t your kitchen plans and are meticulously crafted for both function and design. Be sure to reference the correct model information in this design guide.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Downdraft Hood is properly installed and grounded by a qualied technician. Installation, electrical connections and grounding must comply with all applicable local codes.
REQUIRED CIRCUIT
MODEL
UCVM30FS, UCVM36FS 15 Amp
BREAKER
120V AC, 60 Hz
INSTALLATION CONSIDERATIONS
The information in this design guide provides key features, product dimensions, cutouts and installation specications. Before installing a Thermador Downdraft Hood, be sure to verify the cutout dimensions and electrical connections. Also, always consult with the installation manual packed with the product for complete details before installing.
Thermador Downdraft Hoods may be installed in a wall or island behind a Thermador non-professional gas, electric or induction cooktop to create a convenient cooking center. Refer to the appropriate section for additional specications.
HOOD WIDTH
Downdraft ventilation units should be the same width as the cooking surfaces they are ventilating.
CHOOSING THE CORRECT BLOWER
A variety of interior and exterior blower options (Remote, Inline or Integrated) are available for Thermador’s Downdraft Hoods. If the unit you have selected does not have a blower, one can be purchased separately. Blower selection will vary based on the volume of air that needs to be moved and the length and location of the duct run. For long duct runs with multiple turns and bends, consider using a more powerful blower. For the most efcient air ow exhaust, use a straight run or as few elbows as possible.
186
Remote Blowers (VTR Series) Depending on your preference and ducting situation, these blowers can be mounted on the roof or exterior wall of your home. An exterior installation may be more appealing to reduce noise in the kitchen.
Inline Blowers (VTI series) To minimize noise in the kitchen, these blowers are mounted along the duct line anywhere between the kitchen and the exterior wall. If you have easy access to your duct line (in an attic, for example), this may be an appealing option.
Integrated Blowers (VTN series) These blowers are purchased separately and integrated into the hood or onto the downdraft unit at the time of installation. This option allows you to select your ideal hood with the exact power you require.
Page 4
DOWNDRAFT
FEATURES & BENEFITS
VENTILATION — DOWNDRAFT
CHOOSING THE RIGHT CFM
The power of the cooktop, measured in BTU, is perhaps the most important factor in determining CFM needs for a hood. Professional Gas Rangetops generally should have 1 CFM for every 100 BTU.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust
capacity to handle moisture generated by boiling large pots of water or the grease and smoke resulting from grilling or frying. This cooking style could require a hood or downdraft system with airow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a
relatively small kitchen, a hood with 600 CFM may be adequate ventilation for the cooking space.
• If the cooking surface is in a peninsula or island, a larger
capacity hood can provide better capture when there are cross currents and when the hood needs to be mounted higher. Downdraft ventilation systems are also a good alternative.
• High heat cooking or aromatic foods may require
additional CFM. Increasing capture area by 3" on each side is also a recommended way to address this issue.
LENGTH AND SIzE OF DUCTWORK
Do not use exible duct; it creates back pressure/air turbulence and reduces performance.
Straight runs and gradual turns are best. Use the shortest route with the fewest turns possible.
Proper performance is dependent upon proper ducting. Use a qualied and trained installer. Local building codes may require the use of make-up air systems when using ducted ventilation systems greater than specied CFM of air movement. The specied CFM varies from locale to locale. Consult your HVAC professional for specic requirements in your area.
BLOWER OPTIONS
REMOTE
VTR630D – 600 CFM Use RFPLT600 in roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in roof-mount applications
Requires CV2T6 or CV2T10 Transition
INLINE Requires CV2T6 or CV2T10 Transition
VTI610D – 600 CFM
VTI1010D – 1000 CFM
INTEGRATED
VTN600CV2C – 600 CFM
REMOTE (Mounted to roof or external wall)
VTR630D – 600 CFM VTR1030D – 1000 CFM
INLINE (Mounted between kitchen and external wall)
VTI610D – 600 CFM VTI1010D – 1000 CFM
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct. Transitions, elbows and wall or roof caps are all factors that will add more static pressure, therefore increasing your equivalent duct run.
WARRANTY
Limited warranty parts and labor (2 year)
See page 308 for additional warranty details.
REMOTE BLOWER ACCESSORIES
RFPLT600 For use with Remote Blower VTR630D
1.800.735.4328 | THERMADOR.COM
INTEGRATED (Mounted on hood)
VTN600CV2C – 600 CFM
RFPLT1000 For use with Remote Blower VTR1030D
187
Page 5
VENTILATION
DOWNDRAFT (30"/36")
UCVM30FS / UCVM36FS
MASTERPIECE
UCVM30FS – 30-Inch
UCVM36FS – 36-Inch
UCVM30FS / UCVM36FS
PERFORMANCE
- Suitable for wall or island applications
- Downdraft rises over 13" to capture steam from the tallest pots
- Downdraft recirculation possible with module RECIRC36DF
- Three fan speeds
- Dishwasher-safe full-face lters also act as a splatter shield
- Filter systems are highly efcient at capturing grease
- Powerfully Quiet
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
- Replacement charcoal lters available (CHFILT3036)
DESIGN
- Brushed stainless steel nish
- Easy-to-operate control buttons
®
ventilation systems
SPECIFICATIONS
Available Hood Widths 30" / 36"
Blower Sold Separately —
See Blower Options Table
Duct Size at Discharge 6" Round
Ducting Direction Down, Left or Right
Dishwasher-safe Filters Full-Face Mesh Electrical 120V AC, 60Hz
ACCESSORIES
Recirculation Kit
RECIRC36DF
- Comes complete with 2 charcoal lters, 2 venting grids, and ducting to transition to integrated blower (blower sold separately)
- For toekick heights of 4" or taller
- Wall or island applications
- Easily mounts to integrated blower (VTN600CV2C) under cooktop
- Toekick/socket can be vented in any direction
- Mounts to base of cabinet; recesses into toekick
- To be used only with Thermador Downdraft and Integrated Blower
- Replacement lters are ordered as a service item
- Filters should be replaced twice a year
TRANSITIONS
Transition piece required for installation of inline and remote blowers — downdraft applications only
CV2T6
Transition piece required for installation of 600 CFM Inline and Remote Blowers with 6" duct connections — downdraft applications only
CV2T10
Improves overall performance when installing with Thermador’s 1,000 CFM Inline or Remote Blowers with 10" duct connections — downdraft applications only
6 3/4"
15 1/8"
7
14
Replacement Charcoal Filters
Sold separately as a service item (For use with recirculation module)
/16"
14 3/8"
14 3/8"
Ø 10"
11"
Ø 6"
188
Page 6
VENTILATION
DOWNDRAFT (30"/36")
UCVM30FS / UCVM36FS
VENTILATION — DOWNDRAFT
INSTALLATION OPTIONS
The Thermador Downdraft Hood System is available in 30-inch or 36-inch widths. It is intended for installation with Thermador non-professional gas, electric or induction cooktops only.
A Recirculation Kit (RECIRC36DF) can be purchased separately and used in conjunction with the Integral Blower if ducting to the outside is not a viable option. Refer to the appropriate section for additional specications.
These hoods are designed to be used for side or downward discharge.
36 7/8"
(936 mm)
30 7/8"
(784 mm)
CUTOUT DIMENSIONS (TOP VIEW)
36 7/8"
7
30
/8"
36 7/8"
7
/8"
30
36 7/8"
7
30
/8"
1.800.735.4328 | THERMADOR.COM 189