UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
GENERAL PROPERTIES
Operating Mode Convertible: Ducted /
Maximum CFM Blower Sold Separately
Number of Speed Settings 3-Stage
Motor Location External
Damper Included No
Grease Filter Material Washable Synthetic
Grease Filter Type Multilayer Cassette
FEATURES & BENEFITS
- Suitable for wall or island applications
- Downdraft rises over 13" to capture steam from the tallest pots
- Downdraft recirculation possible with module RECIRC36DF
- Three fan speeds
- Dishwasher-safe full-face lters also act as a splatter shield
ACCESSORIES (OPTIONAL)
25 ft. Blower Connector Cable
EXTNCB25 - For use with the following Inline and Remote
Blowers: VTR630P, VTR1030P, VTR1330P, VTI610P, VTI1010P
Recirculation Kit
RECIRC36DF - Includes 2 charcoal lters, 2 venting grids,
and ducting to transition to Integrated Blower (blower sold
separately)
Roofplates
RFPLT600P - For use with Remote Blower VTR630P
RFPLT1000P - For use with 1000 CFM Remote Blower
VTR1030P and 1300 CFM Blower VTR1330P
Replacement Charcoal Filters
Service Item #291108
TECHNICAL DETAILS
Current (A) 10 A
Volts (V)
Frequency (Hz)
Plug Type
Power Cord Length (in)
DIMENSIONS & WEIGHT
Overall Appliance Dimensions
(Width of Canopy Included) (HxWxD) (in)
Height of the Rise (in.) 13"
Diameter of Air Duct (in.) Back 10"
Net Weight (lbs) 37 lbs
ACCESSORIES (REQUIRED)
Blower (Sold Separately)
BLOWERS AND TRANSITIONS
Remote Blowers
VTR630P - 600 CFM (Requires Transition CV2T6)
VTR1030P - 1000 CFM (Requires Transition CV2T10)
Inline Blowers
VTI610P - 600 CFM (Requires Transition CV2T6)
VTI1010P - 1000 CFM (Requires Transition CV2T10)
Integrated Blower
VTN600CV2C - 600 CFM
Remote and Inline Blower Downdraft Transitions
CV2T6 - Required for installation of 600 CFM Inline and Remote Blowers
with 6" duct connections
CV2T10 - Required for installation of 1000 CFM Inline and Remote
Blowers with 10" duct connections
WARRANTY
Limited Warranty Parts and Labor 2 Year
Recirculating
120 V
60 Hz
120V-3 prong
57"
34 1/2" x 30 7/8" x
3 3/4"
Page 1 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
HOOD DIMENSIONS
30 7/8"
(784 mm)
Page 2 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
HOOD DIMENSIONS
Page 3 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
CUTOUT DIMENSIONS (TOP VIEW)
36 7/8"
7
30
/8"
Page 4 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
CUTOUT DIMENSIONS (TOP VIEW)
36 7/8"
7
/8"
30
Page 5 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
CUTOUT DIMENSIONS (TOP VIEW)
36 7/8"
7
30
/8"
Page 6 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
REMOTE BLOWERS
VTR630P–600 CFM
VTR1030P–1000 CFM
INLINE BLOWERS
VTI610P–600 CFM VTI1010P–1000 CFM
Page 7 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
INTEGRATED BLOWERS
VTN600CV2C–600 CFM
OPTIONAL ACCESSORIES
RECIRCULATION KIT
RECIRC36DF
- Comes complete with 2 charcoal lters, 2 venting grids, and ducting
to transition to integrated blower (blower sold separately)
- For toekick heights of 4" or taller
- Wall or island applications
- Easily mounts to integrated blower (VTN600CV2C) under cooktop
- Toekick / socket can be vented in any direction
- Mounts to base of cabinet; recesses into toekick
- To be used only with Thermador Downdraft and Integrated Blower
- Replacement lters are ordered as a service item
- Filters should be replaced twice a year
REPLACEMENT CHARCOAL FILTERS
Sold separately as service item #291108
(For use with recirculation module)
Page 8 of 9
10 / 15

UCVM30FS
30-INCH DOWNDRAFT VENTILATION
MASTERPIECE® SERIES
REMOTE BLOWER ACCESSORIES
ROOFPLATE RFPLT600P
ROOFPLATE RFPLT1000P EXTNCB25
25 ft. Blower Connector
Cable for use with the
following Inline and
Remote blowers: VTR630P,
VTR1030P, VTR1330P,
VTI610P, VTI1010P
TRANSITIONS
CV2T6
Transition piece required for installation of 600 CFM Inline
and Remote Blowers with 6" duct connections— downdraft
applications only
14 3/8"
CV2T10
Transition piece required for installation of 1000 CFM Inline
and Remote Blowers with 10" duct connections - downdraft
applications only
14 3/8"
Ø 6"
6 3/4"
14 7/16"
Ø 10"
15 1/8"
11"
These warranties give you specific legal ri ghts and you may have other rights th at var y from state to state. Full warranty an d limited warrant y from d ate of in stallation. For co mplete warr anty
details, ref er to you r Use & Ca re manu al, or as k your dealer.
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation
engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write to Thermador indicating the model
numbe r. Specifica tions are correct a t time of printing. Th ermador res erves the ri ght to change p roduct specif ications or d esign without not ice. Some mode ls are certi fied f or use in Canada.
Thermador i s not res pons ible for product s that a re transported f rom the U.S. for u se in Ca nada.
1 800 735 4 328 | USA TH ERMAD OR.COM | CANADA THERMADOR.CA | ©2015 BSH HOME APPLIAN CES CORP ORATION. ALL RIGHTS RE SERVED.
Page 9 of 9
10 / 15