MODELS SHOWN: HPIN48HS ISLAND HOOD, PRD486GDHU PRO HARMONY® RANGE
AND T24IW800SP FREEDOM®WINE PRESERVATION COLUMN
Page 2
VENTILATION
PROFESSIONAL
& MASTERPIECE
VENTILATION
®
SERIES
No need to worry about lingering odors or smoke with our elegant, powerful ventilation systems, featuring design
accents that complement our Professional Series or our Masterpiece Collection. These sophisticated ventilation systems
remove smoke, grease and unhealthy airborne contaminants. From standard wall to specialty hoods, downdrafts, island
and custom inserts, each model has one thing in common: legendary Thermador performance. These powerful, quiet
systems tackle unwanted smoke, grease, heat and odors — quietly and ef ciently — with ventilation power ranging from
600 to 1,300 CFM.
2010
Masterpiece
Series Hood
1.800.735.4328 | THERMADOR.COM
131
Page 3
RANGE, RANGETOP AND VENTILATION MATRIX
PROFESSIONAL SERIES
= PERFECT FIT = VIABLE OPTION
27-INCH DEPTH, 18-INCH TALL
WALL HOODS
24-INCH DEPTH, 18-INCH TALL
WALL HOODS
24-INCH DEPTH, 11-INCH TALL
WALL HOODS
36" PH36GS
42" PH42GS
48" PH48GS
54" PH54GS
30" PH30HS
36" PH36HS
48" PH48HS
30" HPWB30FS
36" HPWB36FS
48" HPWB48FS
36-INCH
PRO GRAND
48-INCH
PRO GRAND
27-INCH DEPTH
48-INCH
PRO GRAND STEAM
42" HPIN42HS
ISLAND HOODS
CUSTOM INSERTS
For optimal performance, the width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador Blowers.
48" HPIN48HS
36" VCIN36JP / 36" VCIB36JP
48" VCIN48JP / 48" VCIB48JP
54" VCIN54JP / 54" VCIB54JP
132
Page 4
VENTILATION
30-INCH
PRO HARMONY
36-INCH
PRO HARMONY
24-INCH DEPTH24-INCH DEPTH
48-INCH
PRO HARMONY
30-INCH
RANGETOP
36-INCH
RANGETOP
48-INCH
RANGETOP
1.800.735.4328 | THERMADOR.COM
133
Page 5
COOKTOP AND VENTILATION MATRIX
MASTERPIECE® SERIES
36-INCH
INDUCTION/
= PERFECT FIT = VIABLE OPTION
30" HMWN30FS
30-INCH
INDUCTION
FREEDOM
INDUCTION
30-INCH
GAS COOKTOP
36-INCH
GAS COOKTOP
WALL HOODS
WALL HOODS
WITH BLOWER
CHIMNEY WALL HOODS
CHIMNEY WALL HOODS
WITH BLOWER
DRAWER HOOD
WITH BLOWER
36" HMWN36FS
48" HMWN48FS
30" HMWB30FS
36" HMWB36FS
36" HMCN36FS
42" HMCN42FS
36" HMCB36FS
42" HMCB42FS
36" HDDW36FS
40" HMIB40HS
134
42" HPIB42HS
ISLAND HOODS
WITH BLOWER
CUSTOM INSERTS
DOWNDRAFTS
For optimal performance, the width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador Blowers.
*Compatible with cooktops of widths up to 42" †Also compatible with Pro Grand Ranges, Pro Harmony Ranges and Professional Rangetops.
48" HPIB48HS*
30" VCI230DS
36" VCI236DS
48" VCI248DS
30" UCVM30FS
36" UCVM36FS
†
†
†
Page 6
VENTILATION
30-INCH
ELECTRIC COOKTOP
30-INCH SENSOR
ELECTRIC COOKTOP
36-INCH
ELECTRIC COOKTOP
36-INCH SENSOR
ELECTRIC COOKTOP
1.800.735.4328 | THERMADOR.COM
135
Page 7
BLOWER SELECTION
AND DUCT GUIDE
PROFESSIONAL SERIES
Type
TypeModel No.
WALL
HOODS
ISLAND
HOODS
CUSTOM INSERTS
Available
Sizes (Widths)
PH_GS36" / 42" / 48" / 54"
HPWB_FS
PH_HS30" / 36" / 48"
HPIN_HS42" / 48"
VCIB_JP36" / 48" / 54"1000
VCIN_JP36" / 48" / 54"
30"600
36" / 48"1000
Blower Information
600
1000
600
1000
1300
600
1000
600
1000
1300
600
1000
600
1000
600
1000
1300
600
1000
600
1000
1300
600
1000
600
1000
CFM
Remote
•
•
•
•
•
•
•
•
•
•
•
•
Inline
•
•
•
•
•
•
•
•
Integrated
•
•
•
•
•
•
•
•
•
Model No.
VTN630C10.3
VTN1030C13.6
VTR630D12.1
VTR1030D14.0
VTR1330E17.5
VTI610D12.1
VTI1010D14.0
Included3.4
Included10.2
VTR630D6.9
VTR1030D8.8
VTR1330E12.3
VTI610D6.9
VTI1010D8.8
VTN630C5.0
VTN1030C8.4
VTR630D
VTR1030D
VTR1330E
VTI610D
VTI1010D
Included12.7
VTR630D6.9
VTR1030D8.8
VTR1330E12.3
VTI610D6.9
VTI1010D8.8
VTN630C10.3
VTN1030C13.6
Total Amps @
Max 10
Amps
120 Volts, 60 Hz
136
MASTERPIECE® SERIES
30"
WALL
HOODS
CHIMNEY
WALL HOODS
ISLAND HOODS
CUSTOM INSERTSVCI2_DS30" / 36" / 48"
DOWNDRAFTUCVM_FS30" / 36"
*Purchase separately at most hardware stores, unless otherwise indicated with a Thermador model number.
INLINE (MOUNTED BETWEEN KITCHEN AND EXTERNAL WALL)
VTI610D – 600 CFMVTI1010D – 1000 CFM
NOTE: All measurements are
made with 3 ft. straight duct,
90° bend followed by 1 ft.
straight duct. These are NOT
free blowing measurements.
1.800.735.4328 | THERMADOR.COM
139
Page 11
EQUIVALENT DUCT LENGTHS FOR COMMONLY
USED TRANSITIONS
DUCT PIECE
Smooth
Straight
3 1/4" x 10"
Straight
3 1/4" x 14"
Straight
90° Elbow
Round
45° Elbow
Round
3 1/4" x 10"
90° Elbow
Round
3 1/4" x 10"
45° Elbow
Round
3 1/4" x 10"
Flat Elbow
Round to
3 1/4" x 10"
3 1/4" x 10"
to Round
Round to
1
/4" x 10"
3
90° Elbow
SIZE OF DUCT
PIECE (IN.)
61.2
70.95
80.7
100.6
N/A1
N/A0.7
612
78
86
65
74
83
N/A5
N/A15
N/A20
61
71
65
73
610
78
EQUIVALENT
LENGTH (FT.)
SIZE OF DUCT
DUCT PIECE
3 1/4" x 10"
to Round
90° Elbow
3 1/4" x 10"
Center Reverse
Elbow Left
3 1/4" x 10"
Center Reverse
Elbow Right
3 1/4" x 10" Left
Reverse Elbow
3 1/4" x 10"
Right Reverse
Elbow
Round
Wall Cap
Round
Roof Cap
2' Long
3 1/4" x 10"
Flex
3 1/4" x 10"
to Round
7" Inline
Backdraft
Damper
3 1/4" x 10"
Roof Jack
and Shutter
NOTE: These commonly used installation parts can be purchased
at a local hardware store. Thermador does not manufacture all
these parts.
PIECE (IN.)
610
75
N/A15
N/A25
N/A15
N/A25
62
72
82
102
62
72
82
N/A20
101
7
N/A
EQUIVALENT
LENGTH (FT.)
140
Page 12
VENTILATION
HOODS THAT FIT WITH YOUR KITCHEN
When selecting a ventilation system, choose from one of our two sophisticated appliance collections. Select Professional Series for the ultimate
in cooking and venting power or the Masterpiece® Series for its sleek styling and numerous convenience functions.
WALL HOODS
Wall hoods offer exceptional, quiet performance and distinctive design options.
• Ef cient, high quality, all stainless steel lters
Our chimney style wall hoods impart a more traditional feel to the kitchen space.
• Adjustable chimney heights suit a range of ceilings
• All stainless steel or stainless steel with glass designs available
• Halogen lighting
VENTILATION
• Dishwasher-safe, stainless steel frame lters
• Automatic Clean Filter Reminder light
ISLAND HOODS
Thermador Island Hoods offer excellent overall ef ciency in drawing away smoke, moisture and heat.
• An option for when a wall surface is not available
• Dishwasher-safe, stainless steel lters
• Slim and sleek design that does not obstruct the views beyond your kitchen
• Halogen lighting
• All stainless steel or stainless steel with elegant glass canopy design
CUSTOM INSERTS
To create a seamless design with wall or island applications, use custom hood inserts.
• Available options for all types of cooking surfaces
• User-friendly ventilation controls or remote control options
• Wall or island applications
• Halogen lighting
DOWNDRAFTS
Downdraft ventilation offers space ef ciency and a sleek look for non-professional cooktops.
• Over 13-inch intake
• Full-face lter combines a lter with splatter shield in one easy-to-remove, dishwasher-safe element
• Ideal in island applications
• 600 CFM recirculation kit option with integrated blower is available for dif cult-to-duct situations
1.800.735.4328 | THERMADOR.COM141
Page 13
142
MODELS SHOWN: PH48HS WALL HOOD AND PRG486GDH PRO HARMONY® RANGE AND PA12CVRJ GRIDDLE
COVER ACCESSORY
Page 14
VENTILATION
WALL
HOODS
VENTILATION — WALL HOODS
Thermador Wall Hoods put the nishing touch on your cooking system, with deep capture areas for
the best overall ef ciency in drawing away smoke, moisture and heat. These elegant hoods combine
style with vigorous performance, generating ventilation power from 600 to 1,300 CFM. Available
in a variety of heights, widths and depths, they accommodate your individual venting needs. All
models include brilliant halogen lighting for enhanced visibility and convenient speed controls. For
ultra-simple cleanup, the removable lters and grease collection trays t easily in your dishwasher.
1.800.735.4328 | THERMADOR.COM
143
Page 15
WALL HOODS
FEATURES & BENEFITS
HALOGEN LIGHTS
Bright halogen lighting spotlights your best recipes.
DELAYED SHUT-OFF
For the greatest ef ciency, our Professional ventilation
models include delayed shut-off to tackle lingering odors.
(Except HMWB30FS, HMWB36FS)
POWERFUL VENTILATION
Breathe deeply with the air-freshening power of up to 1,300
CFM. Our new HPWB Series Professional Hood now has blower
included for ease of installation.
TIME-TO-CLEAN-FILTER LIGHT
Easy cleanup: all Thermador ventilation lters are dishwasher-safe,
and many hoods feature a built-in Time-to-Clean-Filter reminder
light. (Except HMWB30FS, HMWB36FS)
BAFFLE FILTERS
Unique low-pro le, commercial-style
baf e lters maximize grease capture
without affecting ow, and they’re
dishwasher-safe for easy cleanup.
EXTERIOR CONTROLS
Easy-to-clean, easy-to-use pushbutton controls put accuracy at
your ngertips.
KEEP-HOT SHELF
Hold dishes at serving temperature
on our optional Keep-Hot Shelf.
(Perfect for PH36GS, PH42GS,
PH48GS and PH54GS)
PLANNING INFORMATION
MODEL OPTIONS
When selecting a ventilation system, choose from one of our two
sophisticated appliance collections. Select Professional Series for
the ultimate in cooking and venting power or the Masterpiece®
Series for its sleek styling and numerous convenience functions.
Thermador Wall Hoods are available in various depths and
heights to t your kitchen plans and are meticulously crafted for
both function and design. Be sure to reference the correct model
information in this design guide.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Wall Hood is properly installed and
grounded by a quali ed technician. Installation, electrical
connections and grounding must comply with all applicable
local codes.
Install a suitable conduit box (not furnished). An appropriatelysized, UL-listed conduit connector must be used to correctly
attach the conduit to the junction box. Remote blowers require
a 5-wire installation.
REQUIRED
MODEL
PH36GS, PH42GS, PH48GS,
PH54GS15 or 20 Amp
PH30HS, PH36HS, PH48HS15 or 20 Amp
CIRCUIT BREAKER
120V AC, 60 Hz
144
HPWB30FS, HPWB36FS,
HPWB48FS15 or 20 Amp
HMWN30FS, HMWN36FS,
HMWN48FS15 or 20 Amp
HMWB30FS, HMWB36FS15 or 20 Amp
Page 16
WALL HOODS
PLANNING INFORMATION
VENTILATION — WALL HOODS
INSTALLATION CONSIDERATIONS
The information in this design guide provides key
features, product dimensions, cutouts and installation
speci cations. Before installing a Thermador Wall
Hood, be sure to verify the cutout dimensions and
electrical connections. Also, always consult with
the installation manual packed with the product for
complete details before installing.
Thermador Wall Hoods may be installed above a
Thermador Cooktop or Range to create a convenient
cooking center. Refer to the appropriate section for
additional speci cations.
HOOD WIDTH
The hood width should be no less than the width of
the cooking surface. Where space is not restricted, a
wider hood can be used to increase your capture area.
DISTANCE FROM COOKING SURFACE
Proper mounting height is very important. If a hood
is mounted too low, it may be dif cult to cook and be
unsafe. If a hood is mounted too high, performance
may be compromised. For optimal performance, the
distance from the cooking surface to the bottom of the
hood should be a minimum of 30", unless otherwise
noted. Please refer to the installation manual for each
hood and cooktop/range model for proper hood
mounting heights.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation, these blowers can be
mounted on the roof or exterior wall of your home. An exterior installation
may be more appealing to reduce noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are mounted along the
duct line anywhere between the kitchen and the exterior wall. If you have
easy access to your duct line (in an attic, for example), this may be an
appealing option.
Integrated Blowers (VTN series)
These blowers are purchased separately and integrated into the hood or
onto the downdraft unit at the time of installation. This option allows you to
select your ideal hood with the exact power you require.
CHOOSING THE RIGHT CFM
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional gas
cooktops generally should have 1 CFM for every 100 BTU.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with air ow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a relatively small
kitchen, a hood with 600 CFM may be adequate ventilation for the
cooking space.
AVAILABLE CEILING HEIGHT
The standard ceiling height can vary from region to
region and in homes built in different eras. Ceiling
heights, even in the same room, can sometimes vary
by as much as several inches. Kitchen ceiling heights
can vary between 7'6" (or 90") to over 10' (or 120").
Before selecting a Thermador Hood, check the
available installation space and any extra space that
may remain after proper installation of a hood and
cooktop or range. This extra space can be lled using
Thermador’s stainless steel duct cover accessories or
integrated with kitchen cabinetry. The space can also
be adjusted by raising or lowering your hood within
the recommended range (typically 30" to 36" above
the cooking surface).
CHOOSING THE CORRECT BLOWER
A variety of interior and exterior blower options
(Remote, Inline or Integrated) are available for
Thermador’s Professional and Masterpiece® Series
Hoods. If the unit you have selected does not have
a blower, one can be purchased separately. Blower
selection will vary based on the volume of air that
needs to be moved and the length and location of the
duct run. For long duct runs with multiple turns and
bends, consider using a more powerful blower. For the
most ef cient air ow exhaust, use a straight run or as
few elbows as possible.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a good
alternative.
• High heat cooking or aromatic foods may require additional CFM.
Increasing capture area by 3" on each side is also a recommended way to
address this issue.
LENGTH AND SIZE OF DUCTWORK
Do not use exible duct; it creates back pressure/air turbulence and reduces
performance.
Straight runs and gradual turns are best. Use the shortest route with the
fewest turns possible.
Proper performance is dependent upon proper ducting. Use a quali ed and
trained installer. Local building codes may require the use of make-up air
systems when using ducted ventilation systems greater than speci ed CFM of
air movement. The speci ed CFM varies from locale to locale. Consult your
HVAC professional for speci c requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent duct run.
WARRANTY
Limited warranty parts and labor (2 year)
See page 302 for additional warranty details.
1.800.735.4328 | THERMADOR.COM
145
Page 17
VENTILATION
27-INCH DEPTH WALL HOOD (36"/42"/48"/54")
PH36GS / PH42GS / PH48GS / PH54GS
PH36GS / PH42GS / PH48GS / PH54GS
PERFORMANCE
- Three fan speeds
PROFESSIONAL
PH36GS – 36-Inch
PH42GS – 42-Inch
PH48GS – 48-Inch
PH54GS – 54-Inch
SPECIFICATIONS
Available Hood Widths36" / 42" / 48" / 54"
UL Approved for Damp
Environments
BlowerSold Separately – See
Duct Size at Discharge10" Round
Ducting DirectionVertical or Horizontal
Dishwasher-safe FiltersCommercial-Style Baf e
Halogen Lighting
12 Volt, 20 Watt Max.,
G-4 Base, Included
Infrared Keep-Hot Lights
PAR-38 175W or PAR-40
250W, Included
Electrical120V AC, 60Hz
Ye s
Blower Options Table
36"– 2 Bulbs
42" / 48" / 54"– 4 Bulbs
2
- Auto function senses heat from the cooking surface and adjusts fan speeds
- Powerfully Quiet
- Extended capture area ensures removal of smoke and odor
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dimmer lighting –for a soft lighting effect
- Two Infrared Keep-Hot Lamps hold food warm until serving time
- Dishwasher-safe stainless steel baf e lters
- Dishwasher-safe grease collection trays are easily removed
- Filter systems are highly ef cient at capturing grease
- Vertical or horizontal ducting direction
- Seven different blowers to choose from the lineup according to
cooking needs
- Choose from Inline, Remote or Integrated Blowers
- Blowers sold separately
- Hood includes lters, backdraft damper and transition
- Approved by CSA/UL for damp environments
DESIGN
- 27" depth hood is a perfect companion to the Pro Grand Professional Range
- Chiseled design for a seamless integration into any kitchen
- Brushed stainless steel nish
- Halogen lighting spotlights your best recipes
- Easy-to-view recessed control panel with stainless steel buttons
Thermador Wall Hoods may be installed above a
Thermador Cooktop or Range to create a convenient
cooking center. Refer to the appropriate section for
additional speci cations.
Hood installation height above a cooktop or range can
vary. To obtain the necessary installation height above
a Thermador Professional Cooktop or Range, consult
the appliance‘s installation manual. Accessory 6"
and/or 12" tall duct covers are used to ll the space
between the hood and ceiling.
Both vertical and horizontal discharge is possible with
either mounting method. The hood is shipped ready
for vertical discharge.
BLOWER OPTIONS
REMOTE
VTR630D – 600 CFM Use RFPLT600 in
roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in
roof-mount applications
VTR1330E – 1300 CFM Use RFPLT1000 in
roof-mount applications
INLINE
VTI610D – 600 CFM Use WC10 Wall Cap
VTI1010D – 1000 CFM Use WC10 Wall Cap
INTEGRATED
VTN630C – 600 CFM Use WC10 Wall Cap
VTN1030C – 1000 CFM Use WC10 Wall Cap
REMOTE BLOWER ACCESSORIES
RFPLT600
For use with Remote
Blower VTR630D
RFPLT1000
For use with Remote Blowers
VTR1030D and VTR1330E
Thermador Wall Hoods may be installed above a
Thermador Cooktop or Range to create a convenient
cooking center. Refer to the appropriate section for
additional speci cations.
Hood installation height above a cooktop or range can
vary. To obtain the necessary installation height above
a Thermador Professional Cooktop or Range, consult
the appliance‘s installation manual. Accessory 6" and/or
12" duct covers are used to ll the space between the
hood and ceiling.
Both vertical and horizontal discharge is possible with
either mounting method. The hood is shipped ready for
vertical discharge.
– Stainless steel nish
– Perfect for hard to duct installations
– Use with 600 CFM blowers only
Replacement Charcoal Filters
CHFILT3036
For use with Recirculation Kit RECIRC_FS
Page 22
VENTILATION
24-INCH DEPTH WALL HOOD WITH BLOWER (30"/36"/48")
HPWB30FS / HPWB36FS / HPWB48FS
VENTILATION — WALL HOODS
INSTALLATION OPTIONS
Thermador Wall Hoods may be installed above a Thermador Cooktop or Range
to create a convenient cooking center. Refer to the appropriate section for
additional speci cations.
Hood installation height above a cooktop or range can vary. To obtain the
necessary installation height above a Thermador Professional Cooktop or
Range, consult the appliance‘s installation manual. Accessory 6" and/or 12"
duct covers are used to ll the space between the hood and ceiling.
This Thermador Wall Hood can be mounted on a wall or suspended from a
cabinet. The cabinet must be structurally joined to the wall studs to support the
weight of this hood.
These hoods are designed to be used for vertical discharge. A ductless,
recirculation installation is possible with kit RECIRC__FS.
BLOWER PRESSURE CURVES
HPWB30FSHPWB36FS
HOOD DIMENSIONS
HPWB48FS
NOTE: All measurements are made with 3 ft. straight duct, 90° bend and 1 ft.
straight duct at exhaust. These are NOT free blowing measurements.
1.800.735.4328 | THERMADOR.COM
151
Page 23
VENTILATION
WALL HOOD (30"/36"/48")
HMWN30FS / HMWN36FS / HMWN48FS
MASTERPIECE
HMWN30FS – 30-Inch
HMWN36FS – 36-Inch
HMWN48FS – 48-Inch
SPECIFICATIONS
Available Hood Widths30" / 36" / 48"
Blower Sold separately –
Duct Size at Discharge10" Round
Ducting DirectionVertical
Dishwasher-safe FiltersLow-Pro le Baf e
Halogen Lighting
120 Volt, 50 Watt Max.,
GU10 Base, Not Included
Electrical120V AC, 60Hz
See Blower Options table
30" / 36"– 2 Bulbs
48"– 3 Bulbs
HMWN30FS / HMWN36FS / HMWN48FS
PERFORMANCE
- Recirculation possible with kit RECIRC_ _FS (max 600 CFM)
- Three fan speeds plus 10 minute high-power operation mode
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dishwasher-safe low-pro le baf e lters
- Grease collection trays are easily removed and dishwasher-safe
- Filter systems are highly ef cient at capturing grease
- Powerfully Quiet
- 10" Round duct size
- Vertical ducting direction
- Hood includes lters, lights, backdraft damper and transition
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
- Accessories include: Stainless steel duct covers in 6" or 12" heights
- Replacement charcoal lters available (CHFILT3036)
DESIGN
- Brushed stainless steel nish
- Welded, polished seams for a awless design
- Premium electronic touch controls
- Halogen lighting spotlights your best recipes
®
ventilation systems
152
ACCESSORIES
Duct Cover
Stainless steel duct cover
for wall hood applications
– Stainless steel nish
– Perfect for hard to duct installations
– Use with 600 CFM blowers only
Replacement Charcoal Filters
CHFILT3036
For use with Recirculation Kit RECIRC_FS
Page 24
VENTILATION
WALL HOOD (30"/36"/48")
HMWN30FS / HMWN36FS / HMWN48FS
VENTILATION — WALL HOODS
INSTALLATION OPTIONS
Thermador Wall Hoods may be installed above a Thermador Cooktop or
Range to create a convenient cooking center. Refer to the appropriate section
for additional speci cations.
Hood installation height above a cooktop or range can vary. To obtain the
necessary installation height above a Thermador Professional Cooktop or
Range, consult the appliance‘s installation manual. Accessory 6" and/or 12"
duct covers are used to ll the space between the hood and ceiling.
This Thermador Wall Hood can be mounted on a wall or suspended from a
cabinet. The cabinet must be structurally joined to the wall studs to support
the weight of this hood.
These hoods are designed to be used for vertical discharge. A ductless,
recirculation installation is possible with kit RECIRC__FS.
These hoods are not recommended to be used over indoor grills.
– Stainless steel nish
– Perfect for hard to duct installations
– Use with 600 CFM blowers only
Replacement Charcoal Filters
CHFILT3036
For use with Recirculation Kit RECIRC_FS
Page 26
VENTILATION
WALL HOOD WITH BLOWER (30"/36")
HMWB30FS / HMWB36FS
VENTILATION — WALL HOODS
INSTALLATION OPTIONS
Thermador Wall Hoods may be installed above a Thermador
Cooktop or Range to create a convenient cooking center.
Refer to the appropriate section for additional speci cations.
Hood installation height above a cooktop or range can vary.
To obtain the necessary installation height above a Thermador
Professional Cooktop or Range, consult the appliance‘s
installation manual. Accessory 6" and/or 12" duct covers are
used to ll the space between the hood and ceiling.
This Thermador Wall Hood can be mounted on a wall or
suspended from a cabinet. The cabinet must be structurally
joined to the wall studs to support the weight of this hood.
These hoods are designed to be used for vertical discharge.
A ductless, recirculation installation is possible with kit
RECIRC__FS.
These hoods are not recommended to be used over indoor grills.
BLOWER PRESSURE CURVES
HMWB30FS
HOOD DIMENSIONS
HMWB36FS
NOTE: All measurements are made with 3 ft. straight duct,
90° bend and 1 ft. straight duct at exhaust. These are NOT
free blowing measurements.
1.800.735.4328 | THERMADOR.COM155
Page 27
156
MODELS SHOWN: HDDW36FS CHIMNEY WALL DRAWER HOOD, SGSX365FS GAS COOKTOP
AND MED301JS BUILT-IN OVEN
Page 28
VENTILATION
CHIMNEY
WALL
VENTILATION — CHIMNEY WALL HOODS
HOODS
Our Masterpiece® Series chimney style wall hoods impart a more traditional feel to the
kitchen space and create a dramatic gathering point. Each model is adjustable to suit a range
of ceiling heights and includes conveniences such as dishwasher-safe, anodized lters and
electronic 4-speed controls. Halogen lighting brilliantly illuminates your cooking space for
excellent visibility.
1.800.735.4328 | THERMADOR.COM157
Page 29
CHIMNEY WALL HOODS
FEATURES & BENEFITS
HALOGEN LIGHTS
Bright halogen lighting spotlights your best recipes.
MESH FILTERS
Aluminum mesh lters with stainless
steel frame maximize grease capture
without affecting ow and feature a
quick release latch for easy cleanup.
PLANNING INFORMATION
MODEL OPTIONS
Thermador Masterpiece Series Chimney Wall Hoods feature
sleek styling and numerous convenience functions. Chimney
Wall Hoods are available in 36-inch and 42-inch widths and are
adjustable to suit a range of ceiling heights. All stainless steel
or stainless steel with glass designs are available. Be sure to
reference the correct model information in this design guide.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Chimney Wall Hood is properly installed
and grounded by a quali ed technician. Installation, electrical
connections and grounding must comply with all applicable
local codes.
If possible, site the earthed socket directly behind the chimney
paneling. The grounded socket should be connected via its own
circuit. If the grounded socket is no longer accessible following
installation of the hood, ensure that there is a permanently
installed disconnector.
The information in this design guide provides key features,
product dimensions, cutouts and installation speci cations.
Before installing a Thermador Chimney Wall Hood, be sure to
verify the cutout dimensions and electrical connections. Also,
always consult with the installation manual packed with the
product for complete details before installing.
158
ELECTRONIC TOUCH CONTROL
The sleek electronic touch control panel
is easy-to-use and easy-to-clean.
TIME-TO-CLEAN-FILTER LIGHT
Easy cleanup: All Thermador ventilation lters are dishwasher-safe,
and many hoods feature a built-in Time-to-Clean-Filter reminder
light. (Except HMCB36FS, HMCB42FS)
DELAYED SHUT-OFF
For the greatest ef ciency, our Masterpiece
models include delayed shut-off to tackle lingering odors.
(Except HMCB36FS, HMCB42FS)
®
ventilation
Thermador Chimney Wall Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop
to create a convenient cooking center. Refer to the appropriate
section for additional speci cations.
DISTANCE FROM COOKING SURFACE
Proper mounting height is very important. If a hood is mounted
too low, it may be dif cult to cook and be unsafe. If a hood is
mounted too high, performance may be compromised.
For optimal performance, the distance from the cooking surface
to the bottom of the hood should be a minimum of 30", unless
otherwise noted. Please refer to the installation manual for each
hood and cooktop/range model for proper hood mounting
heights.
HOOD WIDTH
The hood width should be no less than the width of the cooking
surface. Where space is not restricted, a wider hood can be used
to increase your capture area.
Page 30
CHIMNEY WALL HOODS
PLANNING INFORMATION
VENTILATION — CHIMNEY WALL HOODS
AVAILABLE CEILING HEIGHT
The standard ceiling height can vary from region to
region and in homes built in different eras. Ceiling
heights, even in the same room, can sometimes vary
by as much as several inches. Kitchen ceiling heights
can vary between 7'6" (or 90") to over 10' (or 120").
Before selecting your hood, check your available
installation space and any extra space that may remain
after proper installation of your hood and cooktop or
range. This extra space can be lled using Thermador‘s
Stainless Steel Duct Cover or Chimney Extension
Accessories. The space can also be adjusted by raising
or lowering your hood within the recommended range
(typically 30" to 36" above the cooking surface).
CHOOSING THE CORRECT BLOWER
A variety of interior and exterior blower options
(Remote, Inline or Integrated) are available for
Thermador’s Professional and Masterpiece® Series
Hoods. If the unit you have selected does not have
a blower included, one can be purchased separately.
Blower selection will vary based on the volume of air
that needs to be moved and the length and location
of the duct run. For long duct runs with multiple turns
and bends, consider using a more powerful blower. For
the most ef cient air ow exhaust, use a straight run or
as few elbows as possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation,
these blowers can be mounted on the roof or exterior
wall of your home. An exterior installation may be
more appealing to reduce noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are
mounted along the duct line anywhere between the
kitchen and the exterior wall. If you have easy access
to your duct line (in an attic, for example), this may be
an appealing option.
Integrated Blowers (VTN series)
These blowers are purchased separately and
integrated into the hood or onto the downdraft unit at
the time of installation. This option allows you to select
your ideal hood with the exact power you require.
SPECIAL NOTE: Always allow access to the blower for
serviceability, should it be needed.
CHOOSING THE RIGHT CFM
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional gas
cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU,
choose a blower with a minimum of 100 CFM per 12" of cooktop width.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with air ow of 600 to 1,300 CFM.
• High heat cooking or aromatic foods may require additional CFM.
Increasing capture area by 3" on each side is also a recommended way to
address this issue.
• For those who are used to preparing quick meals in a relatively small
kitchen, a hood with 400 to 600 CFM may be adequate ventilation for the
cooking space.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a
good alternative.
LENGTH AND SIZE OF DUCTWORK
Proper performance is dependent upon proper ducting. Use a quali ed and
trained installer.
Do not use exible duct; it creates back pressure/air turbulence and reduces
performance.
Straight runs and gradual turns are best. Use the shortest route with the
fewest turns possible.
Local building codes may require the use of makeup air systems when using
ducted ventilation systems greater than speci ed CFM of air movement. The
speci ed CFM varies from locale to locale. Consult your HVAC professional
for speci c requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent duct run.
WARRANTY
Limited warranty parts and labor (2 year)
See page 302 for additional warranty details.
1.800.735.4328 | THERMADOR.COM159
Page 31
VENTILATION
CHIMNEY WALL HOOD (36"/42")
HMCN36FS / HMCN42FS
HMCN36FS / HMCN42FS
PERFORMANCE
- Three fan speeds plus 10 minute high-power operation mode
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
- Dimmer lighting – for those hours after a late meal
- Dishwasher-safe stainless-frame mesh lters
- Filter systems are highly ef cient at capturing grease
- Powerfully Quiet
- Vertical ducting direction
- 8" Round duct size
- Telescopic chimney –adjustable at installation
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
®
ventilation systems
MASTERPIECE
HMCN36FS – 36-Inch
HMCN42FS – 42-Inch
SPECIFICATIONS
Available Hood Widths36" / 42"
BlowerSold Separately —
Duct Size at Discharge8" Round
Ducting DirectionVertical
Ceiling Heights 8' 2" ft. to 9 ft.
Dishwasher-safe Filters 3 Mesh with
Halogen Lighting
12 Volt, 20 Watt Max.,
G-4 Base, Included
Electrical
See Blower Options Table
Stainless-Frame
3 Bulbs
120V AC, 60Hz
DESIGN
- Brushed stainless steel nish
- Welded, polished seams for a awless design
- Premium electronic touch controls
- Halogen lighting spotlights your best recipes
160
ACCESSORIES
Chimney Extension
CHIMXHMC
Stainless steel chimney hood extension for up to 11-foot
ceiling applications. Extension replaces upper section
of standard chimney extension.
Page 32
VENTILATION
CHIMNEY WALL HOOD (36"/42")
HMCN36FS / HMCN42FS
VENTILATION — CHIMNEY WALL HOODS
INSTALLATION OPTIONS
Thermador Chimney Wall Hoods may be installed above
a Thermador non-professional gas, electric, or induction
cooktop to create a convenient cooking center. Refer to
the appropriate section for additional speci cations.
Hood installation height above a cooktop can vary.
To obtain the necessary installation height above a
Thermador non-professional gas, electric, or induction
cooktop, consult the appliance’s installation manual.
Thermador Chimney Wall Hoods must be mounted on
a wall.
These hoods are designed to be used for vertical
discharge. The HMCN_FS hood offers the exibility to
choose a blower from our lineup to t your installation
needs. All other chimney wall hoods have the
convenience of integrated blowers.
RFPLT1000
For use with Remote
Blowers VTR1030D
and VTR1330E
1.800.735.4328 | THERMADOR.COM
INLINE (Mounted between kitchen and external wall)
VTI610D – 600 CFMVTI1010D – 1000 CFM
INTEGRATED (Mounted on hood)
VTN1080F – 1000 CFM
161
Page 33
VENTILATION
CHIMNEY WALL HOOD WITH BLOWER (36"/42")
HMCB36FS / HMCB42FS
HMCB36FS / HMCB42FS
PERFORMANCE
- 600 CFM Integrated Blower included
- Three fan speeds plus 10 minute high-power operation mode
- Dishwasher-safe stainless-frame mesh lters
MASTERPIECE
HMCB36FS – 36-Inch
HMCB42FS – 42-Inch
- Filter systems are highly ef cient at capturing grease
- Powerfully Quiet
- 6" Round duct size
- Vertical ducting direction
- Telescopic chimney –adjustable at installation
- Hood includes lters, lights, backdraft damper and transition
DESIGN
- Brushed stainless steel nish
- Welded, polished seams for a awless design
- Easy-to-operate control buttons
- Halogen lighting spotlights your best recipes
®
ventilation systems
SPECIFICATIONS
Available Hood Widths36" / 42"
Blower600 CFM Blower Included
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights 8' 2" ft. to 9 ft.
Dishwasher-safe Filters 3 Mesh with
Halogen Lighting
12 Volt, 20 Watt Max.,
G-4 Base, Included
Electrical120V AC, 60Hz
Stainless-Frame
3 Bulbs
ACCESSORIES
Chimney Extension
CHIMXHMC
Stainless steel chimney hood extension for up to 11-foot
ceiling applications. Extension replaces upper section
of standard chimney extension.
162
Page 34
VENTILATION
CHIMNEY WALL HOOD WITH BLOWER (36"/42")
HMCB36FS / HMCB42FS
VENTILATION — CHIMNEY WALL HOODS
INSTALLATION OPTIONS
Thermador Chimney Wall Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop
to create a convenient cooking center. Refer to the appropriate
section for additional speci cations.
Hood installation height above a cooktop can vary. To obtain
the necessary installation height above a Thermador nonprofessional gas, electric, or induction cooktop, consult the
appliance’s installation manual.
Thermador Chimney Wall Hoods must be mounted on a wall.
These hoods are designed to be used for vertical discharge.
A 600 CFM integrated blower is included.
BLOWER PRESSURE CURVES
HMCB36FS
HOOD DIMENSIONS
HMCB42FS
NOTE: All measurements are made with 3 ft. straight duct,
90° bend and 1 ft. straight duct at exhaust. These are NOT
free blowing measurements.
1.800.735.4328 | THERMADOR.COM
163
Page 35
VENTILATION
CHIMNEY WALL DRAWER HOOD (36")
HDDW36FS
HDDW36FS
INNOVATION
- Unique sliding stainless canopy can be pushed back against
the wall for increased head room
- 45% increase in capture area when hood is extended
PERFORMANCE
- 600 CFM Integrated Blower included
- Three fan speeds plus 10 minute high-power operation mode
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
MASTERPIECE
HDDW36FS – 36-Inch
of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dimmer lighting – for those hours after a late meal
- Dishwasher-safe stainless-frame mesh lters
- Filter systems are highly ef cient at capturing grease
- Powerfully Quiet
- Sound insulation mats make this hood barely audible
- 6" Round duct size
- Vertical ducting direction
- Telescopic chimney –adjustable at installation
- Hood includes lters, backdraft damper and transition
®
ventilation systems
SPECIFICATIONS
Available Hood Widths36"
Blower600 CFM Blower Included
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights 7
Dishwasher-safe Filters 4 Mesh with
Halogen Lighting
12 Volt, 20 Watt Max.,
G-4 Base, Included
Electrical
3
/4 ft. to 9 1/2 ft.
Stainless-Frame
4 Bulbs
120V AC, 60Hz
ACCESSORIES
Chimney Extension
DESIGN
- Brushed stainless steel nish
- Welded, polished seams for a awless design
- Premium electronic touch controls
- Halogen lighting spotlights your best recipes
THERMADOR EXCLUSIVE
164
CHIMXHDD
Stainless steel chimney hood extension for up to 11-foot
ceiling applications. Extension replaces upper section
of standard chimney extension.
Page 36
CHIMNEY WALL DRAWER HOOD (36")
INSTALLATION OPTIONS
Thermador Chimney Wall Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop
to create a convenient cooking center. Refer to the appropriate
section for additional speci cations.
Hood installation height above a cooktop can vary. To obtain
the necessary installation height above a Thermador nonprofessional gas, electric, or induction cooktop, consult the
appliance’s installation manual.
Thermador Chimney Wall Hoods must be mounted on a wall.
These hoods are designed to be used for vertical discharge.
A 600 CFM integrated blower is included.
BLOWER PRESSURE CURVES
HDDW36FS
VENTILATION
HDDW36FS
INSTALLATION NOTE: This product ships with two
transport brackets to hold the moveable canopy in place
during shipping and installation. After installation, be sure to
remove the brackets to operate the sliding drawer canopy.
VENTILATION — CHIMNEY WALL HOODS
VENTILATION — CHIMNEY WALL HOODS
NOTE: All measurements are made with 3 ft. straight duct,
90° bend and 1 ft. straight duct at exhaust. These are NOT
free blowing measurements.
1.800.735.4328 | THERMADOR.COM
165
Page 37
MODELS SHOWN: HMIB40HS ISLAND HOOD AND CIT365KB INDUCTION COOKTOP166
Page 38
VENTILATION
ISLAND
HOODS
VENTILATION — ISLAND HOODS
Thermador Island Hoods put the nishing touches on your cooking system, with excellent
overall ef ciency in drawing away smoke, moisture and heat. The adjustable chimney height is
perfect over island cooktop or range installations. Dishwasher-safe lters make cleanup easy.
1.800.735.4328 | THERMADOR.COM
167
Page 39
ISLAND HOODS
FEATURES & BENEFITS
PLANNING INFORMATION
MODEL OPTIONS
Thermador Professional Series Island Hoods are available in
42-inch and 48-inch widths and feature a stainless steel design.
Masterpiece® Series Island Hoods are available in a 40-inch,
42-inch and 48-inch widths and feature a stainless steel design
and the 40-inch has an elegant glass canopy. All of our island
hoods are adjustable to suit ceiling heights of up to 9 feet.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Wall Hood is properly installed and
grounded by a quali ed technician. Installation, electrical
connections and grounding must comply with all applicable
local codes.
REQUIRED
MODEL
HPIN42HS, HPIN48HS
HPIB42HS, HPIB48HS
HMIB40HS
CIRCUIT BREAKER
120V AC, 60 Hz
Max 10 Amp
EXTERIOR CONTROLS
Easy-to-clean, easy-to-use push-button controls put accuracy at
your ngertips.
POWERFULLY QUIET® OPERATION
Steam, smoke and odors are no problem for Thermador‘s ducted
ventilation systems.
TIME-TO-CLEAN-FILTER LIGHT
Easy cleanup: All Thermador ventilation lters are dishwasher-safe, and
many hoods feature a built-in Time-to-Clean-Filter reminder light.
DISHWASHER-SAFE FILTERS
Dishwasher-safe aluminum lters for easy-clean maintenance.
DELAYED SHUT-OFF
For the greatest ef ciency, our Professional and Masterpiece®
ventilation models include delayed shut-off to tackle lingering odors.
HALOGEN LIGHTS
Bright halogen lighting spotlights your
best recipes.
INSTALLATION CONSIDERATIONS
The information in this design guide provides key features,
product dimensions and installation speci cations. Before
installing a Thermador Island Hood, be sure to verify the
dimensions and electrical connections. Also, always consult with
the installation manual packed with the product for complete
details before installing.
Thermador Island Hoods may be installed above a Thermador
Cooktop or Range to create a convenient cooking center. Refer
to the appropriate section for additional speci cations.
HOOD WIDTH
The hood width should be no less than the width of the cooking
surface. Where space is not restricted, a wider hood can be
used to increase your capture area. Island installations require a
greater capture area; therefore the hoods used should overlap
your cooking surface by a minimum of 3" to 6" on either side.
DISTANCE FROM COOKING SURFACE
Proper mounting height is very important. If a hood is mounted
too low, it may be dif cult to cook and be unsafe. If a hood
is mounted too high, performance may be compromised. For
optimal performance, the distance from the cooking surface to
the bottom of the hood should be a minimum of 30", unless
otherwise noted. Please refer to the installation manual for
each hood and cooktop/range model for proper hood
mounting heights.
168
Page 40
ISLAND HOODS
PLANNING INFORMATION
VENTILATION — ISLAND HOODS
AVAILABLE CEILING HEIGHT
The standard ceiling height can vary from region to
region and in homes built in different eras. Ceiling
heights, even in the same room, can sometimes vary
by as much as several inches. Kitchen ceiling heights
can vary between 7'6" (or 90") to over 10' (or 120").
Before selecting a Thermador Hood, check the
available installation space and any extra space that
may remain after proper installation of a hood and
cooktop or range. This extra space can be lled using
Thermador’s stainless steel duct cover accessories. The
space can also be adjusted by raising or lowering your
hood within the recommended range (typically 30" to
36" above the cooking surface).
CHOOSING THE CORRECT BLOWER
A variety of interior and exterior blower options
(Remote or Inline) are available for Thermador’s
Professional Series Island Hoods. If the unit you
have selected does not have a blower, one can be
purchased separately. Blower selection will vary based
on the volume of air that needs to be moved and the
length and location of the duct run. For long duct
runs with multiple turns and bends, consider using
a more powerful blower. For the most ef cient air
ow exhaust, use a straight run or as few elbows
as possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation,
these blowers can be mounted on the roof or exterior
wall of your home. An exterior installation may be
more appealing to reduce noise in the kitchen.
Inline Blowers (VTI Series)
To minimize noise in the kitchen, these blowers are
mounted along the duct line anywhere between the
kitchen and the exterior wall. If you have easy access
to your duct line (in an attic, for example), this may be
an appealing option.
CHOOSING THE RIGHT CFM
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional Gas
Cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece®
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU,
choose a blower with a minimum of 100 CFM per 12" of cooktop width.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with air ow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a relatively small
kitchen, a hood with 400 to 600 CFM may be adequate ventilation for the
cooking space.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a
good alternative.
• High heat cooking or aromatic foods may require additional CFM.
Increasing capture area by 3" on each side is also a recommended way to
address this issue.
LENGTH AND SIZE OF DUCTWORK
Do not use exible duct; it creates back pressure/air turbulence and
reduces performance.
Straight runs and gradual turns are best. Use the shortest route with the
fewest turns possible.
Proper performance is dependent upon proper ducting. Use a quali ed and
trained installer. Local building codes may require the use of make-up air
systems when using ducted ventilation systems greater than speci ed CFM of
air movement. The speci ed CFM varies from locale to locale. Consult your
HVAC professional for speci c requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent duct run.
1.800.735.4328 | THERMADOR.COM
WARRANTY
Limited warranty parts and labor (2 year)
See page 302 for additional warranty details.
169
Page 41
VENTILATION
LOW PROFILE ISLAND HOOD (42"/48")
HPIN42HS / HPIN48HS
HPIN42HS / HPIN48HS
PERFORMANCE
- Three fan speeds
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dishwasher-safe frameless lters with stainless steel covers
- Filter systems are highly ef cient at capturing grease
PROFESSIONAL
HPIN42HS – 42-Inch
HPIN48HS – 48-Inch
SPECIFICATIONS
Available Hood Widths42" / 48"
BlowerSold Separately —
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights8' 2" ft. to 9 ft.
Dishwasher-safe Filters Stainless Steel Filter
Halogen Lighting
12 Volt, 20 Watt Max.,
G-4 Base, Included
Electrical120V AC, 60 Hz
See Blower Options Table
4 Bulbs
- Powerfully Quiet
- Vertical ducting direction
- 6" round duct size
- Blowers sold separately
DESIGN
- Sleek appearance does not obstruct views beyond the kitchen
- Chiseled design for a seamless integration into any kitchen
- Halogen lighting spotlights your best recipes
- Brushed stainless steel nish
- Stainless steel control buttons
®
ventilation systems
170
Page 42
VENTILATION
LOW PROFILE ISLAND HOOD (42"/48")
HPIN42HS / HPIN48HS
VENTILATION — ISLAND HOODS
INSTALLATION OPTIONS
Thermador Professional Series Island Hoods may be
installed above a Thermador Professional Cooktop or
Range to create a convenient cooking center. Refer to
the appropriate section for additional speci cations.
Hood installation height above a cooktop can vary.
To obtain the necessary installation height above a
Thermador Cooktop or Range, consult the appliance‘s
installation manual.
Thermador Island Hoods are suspended from the
ceiling. These hoods are designed to be used for
vertical discharge. A blower must be purchased
separately.
BLOWER OPTIONS
REMOTE
VTR630D – 600 CFM Use RFPLT600 in
roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in
roof-mount applications
VTR1330E – 1300 CFM Use RFPLT1000 in
roof-mount applications
INLINE
VTI610D – 600 CFM
VTI1010D – 1000 CFM
See page 167 for further details.
HOOD DIMENSIONS
31 3/16"
7
/16"
41
792
1052
31 3/16"
7
/16"
41
792
1052
REMOTE BLOWER ACCESSORIES
RFPLT600
For use with Remote
Blower VTR630D
RFPLT1000
For use with Remote
Blowers VTR1030D
and VTR1330E
INLINE (Mounted between kitchen and external wall)
VTI610D – 600 CFMVTI1010D – 1000 CFM
171
Page 43
VENTILATION
LOW PROFILE ISLAND HOOD WITH BLOWER (42"/48")
HPIB42HS / HPIB48HS
HPIB42HS / HPIB48HS
PERFORMANCE
- 600 CFM Integrated Blower included
- Recirculation possible with kit RECIRISL
- Three fan speeds
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dishwasher-safe frameless lters with stainless steel covers
MASTERPIECE
HPIB42HS – 42-Inch
HPIB48HS – 48-Inch
SPECIFICATIONS
Available Hood Widths42" / 48"
Blower600 CFM Blower Included
Duct Size at Discharge6" Round
Ducting DirectionVertical
Ceiling Heights 8' 2" ft. to 9 ft.
Dishwasher-safe Filters Stainless Steel Filter
Halogen Lighting
12 Volt, 20 Watt Max.,
G-4 Base, Included
Electrical120V AC, 60 Hz
4 Bulbs
- Filter systems are highly ef cient at capturing grease
- Powerfully Quiet
- 6" Round duct size
- Vertical ducting direction
- All-in-one solution with an integrated blower included
- Hood includes lters, backdraft damper and transition
- Replacement charcoal lters available (CHFILISL)
DESIGN
- Sleek appearance does not obstruct views beyond
the kitchen
- Brushed stainless steel nish
- Chiseled design for a seamless integration into any kitchen
- Halogen lighting spotlights your best recipes
- Stainless steel control buttons
®
ventilation systems
172
ACCESSORIES
Island Hood Recirculation Kit
RECIRISL
- Stainless steel nish
- Perfect for hard to duct installations
- Use with 600 CFM blowers only
Replacement Charcoal Filters
CHFILISL
For use with Recirculation Kit RECIRISL
Page 44
VENTILATION
LOW PROFILE ISLAND HOOD WITH BLOWER (42"/48")
HPIB42HS / HPIB48HS
VENTILATION — ISLAND HOODS
INSTALLATION OPTIONS
Thermador Masterpiece® Series Island Hoods may be installed above a
Thermador non-professional gas, electric, or induction cooktop to create a
convenient cooking center. Refer to the appropriate section for additional
speci cations.
Hood installation height above a cooktop can vary. To obtain the necessary
installation height above a Thermador Cooktop or Range, consult the
appliance‘s installation manual.
Thermador Island Hoods are suspended from the ceiling. These hoods are
designed to be used for vertical discharge. A 600 CFM blower is included.
Thermador duct covers are designed for universal application.
In recirculation mode the louvers should be towards the ceiling for exhaust
air to escape in the kitchen.
In ducted mode, the same duct cover can be turned upside down to hide
away the louvers behind the lower duct cover piece.
BLOWER PRESSURE CURVES
HPIB42HS
EXTERNAL EXHAUST
31 3/16"
7
41
/16"
792
1052
31 3/16"
7
/16"
41
792
1052
HPIB48HS
NOTE: All measurements are made with 3 ft. straight duct,
90° bend and 1 ft. straight duct at exhaust. These are NOT
free blowing measurements.
INTERNAL RECIRCULATION
31 3/16"
7
/16"
41
792
1052
31 3/16"
7
/16"
41
792
1052
1.800.735.4328 | THERMADOR.COM
173
Page 45
VENTILATION
GLASS ISLAND HOOD WITH BLOWER (40")
HMIB40HS
HMIB40HS
PERFORMANCE
- 600 CFM Integrated Blower included
- An ideal solution for island cooktop installations
- Four fan speeds including one intensive level
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dimmer lighting – for a soft lighting effect completely
adjustable by user
- Dishwasher-safe stainless steel mesh lters
MASTERPIECE
HMIB40HS – 40-Inch
SPECIFICATIONS
Available Hood Width40"
Blower600 CFM Blower Included
Halogen Lighting
12 Volt, 20 Watt Max.,
G-4 Base, Included
Electrical120V AC, 60 Hz
4 Bulbs
- Filter systems are highly ef cient at capturing grease
- Easy-to-operate control buttons
- Powerfully Quiet
- Perfect t for 30" & 36" cooktops
- 6" Round duct size
- Vertical ducting direction
DESIGN
- Stunning combination of glass and stainless steel with
Masterpiece® design elements
- Chiseled design for a seamless integration into any kitchen
- Halogen lighting spotlights your best recipes
- Brushed stainless steel nish
- Premium electronic touch controls
®
ventilation systems
174
ACCESSORIES
Island Hood Recirculation Kit
RECIRISL
- Stainless steel nish
- Perfect for hard to duct installations
- Use with 600 CFM blowers only
Replacement Charcoal Filters
CHFILISL
For use with Recirculation Kit RECIRISL
Page 46
VENTILATION
GLASS ISLAND HOOD WITH BLOWER (40")
HMIB40HS
VENTILATION — ISLAND HOODS
VENTILATION — ISLAND HOODS
INSTALLATION OPTIONS
Thermador Masterpiece® Series Island Hoods may be installed
above a Thermador non-professional gas, electric, or induction
cooktop to create a convenient cooking center. Refer to the
appropriate section for additional speci cations.
Hood installation height above a cooktop can vary. To obtain
the necessary installation height above a Thermador Cooktop or
Range, consult the appliance‘s installation manual.
Thermador Island Hoods are suspended from the ceiling. These
hoods are designed to be used for vertical discharge. A 600
CFM blower is included.
BLOWER PRESSURE CURVES
HMIB40HS
EXTERNAL EXHAUST
31 3/16"
7
41
/16"
792
1052
INTERNAL RECIRCULATION
31 3/16"
7
/16"
41
792
1052
NOTE: All measurements are made with 3 ft. straight duct,
90° bend and 1 ft. straight duct at exhaust. These are NOT
free blowing measurements.
1.800.735.4328 | THERMADOR.COM
175
Page 47
MODELS SHOWN: VCI248DS PROFESSIONAL SERIES CUSTOM INSERT176
Page 48
VENTILATION
CUSTOM
INSERTS
VENTILATION — CUSTOM INSERTS
Use Thermador Custom Hood Inserts within custom hood applications to create a seamless
design with wall or island applications. These inserts ef ciently and quietly remove odor
and steam with easy-to-access controls. Inserts are available for both professional and nonprofessional applications.
1.800.735.4328 | THERMADOR.COM
177
Page 49
CUSTOM INSERTS
FEATURES & BENEFITS
REMOTE VENTILATION CONTROL
Remote controls for customized ventilation applications
are easy to use and have a sophisticated and professional
style. (photo represents VCI2REMFS)
MESH FILTERS
Aluminum mesh lters with
stainless steel frame maximize
grease capture without affecting
ow. (VCI230DS, VCI236DS,
VCI248DS only)
BAFFLE FILTERS
Stainless steel commercial-style
baf e lters maximize grease
capture and they're dishwasher
safe for easy clean-up. (VCIN and
VCIB Series)
HALOGEN LIGHTS
Bright halogen lighting spotlights your best recipes.
CUSTOM HOOD INSERT
Specially designed for professional custom hood applications to create
a concealed ventilation system.
TIME-TO-CLEAN-FILTER LIGHT
Easy cleanup: All Thermador ventilation lters are dishwasher-safe, and
feature a built-in Time-to-Clean-Filter reminder light.
DELAYED SHUT-OFF
For the greatest ef ciency, our Professional ventilation models include
delayed shut-off to tackle lingering odors.
PUSH BUTTON CONTROLS
Concealed three-speed, push-button controls are easy to use.
BAFFLE FILTERS
The commercial style baf e lters make high-grease cooking easy.
The dishwasher-safe lters are stainless steel.
PLANNING INFORMATION
MODEL OPTIONS
Thermador Custom Hood Inserts are available for both
professional and non-professional applications. The Professional
Series Custom Hood Inserts are available in 30-inch, 36-inch,
48-inch, and 54-inch widths. The Masterpiece® Series Custom
Hood Inserts are available in 21-inch (for 30-inch wide
installations) and 29-inch (for 36-inch wide installations), 30-inch,
36-inch, and 48-inch widths.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Custom Insert is properly installed
and grounded by a quali ed technician. Installation, electrical
connections and grounding must comply with all applicable
local codes.
The information in this design guide provides
key features, product dimensions and installation
speci cations. Before installing a Thermador Custom
Hood Insert, be sure to verify the dimensions and
electrical connections. Also, always consult with
the installation manual packed with the product for
complete details before installing.
Professional Custom Series Hood Inserts are designed
for installation with all professional-style cooktops
and ranges. Masterpiece Custom Series Hood Inserts
are designed for installation with non-professional
gas, electric or induction cooktops. Refer to the
appropriate section for additional speci cations.
HOOD WIDTH
The hood width should be no less than the width of
the cooking surface. Where space is not restricted, a
wider hood can be used to increase your capture area.
DISTANCE FROM COOKING SURFACE
Proper mounting height is very important. If a hood
is mounted too low, it may be dif cult to cook and be
unsafe. If a hood is mounted too high, performance
may be compromised. For optimal performance, the
distance from the cooking surface to the bottom of the
hood should be a minimum of 30", unless otherwise
noted. Please refer to the installation manual for each
hood and cooktop/range model for proper hood
mounting heights.
CHOOSING THE RIGHT CFM
The power of the cooktop or range, measured in BTU, is perhaps the most
important factor in determining CFM needs for a hood. Professional Gas
Cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU,
choose a blower with a minimum of 100 CFM per 12" of cooktop width.
You should also consider the cooking space and cooking style of your client.
• More demanding cooks usually require more exhaust capacity to handle
moisture generated by boiling large pots of water or the grease and smoke
resulting from grilling or frying. This cooking style could require a hood or
downdraft system with air ow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a relatively small
kitchen, a hood with 400 to 600 CFM may be adequate ventilation for the
cooking space.
• If the cooking surface is in a peninsula or island, a larger capacity hood can
provide better capture when there are cross currents and when the hood
needs to be mounted higher. Downdraft ventilation systems are also a
good alternative.
• High heat cooking or aromatic foods may require additional CFM.
Increasing capture area by 3" on each side is also a recommended way to
address this issue.
LENGTH AND SIZE OF DUCTWORK
Do not use exible duct; it creates back pressure/air turbulence and reduces
performance.
Straight runs and gradual turns are best. Use the shortest route with the
fewest turns possible.
CHOOSING THE CORRECT BLOWER
A variety of interior and exterior blower options
Remote, Inline or Integrated) are available for
Thermador’s Professional and Masterpiece Series
Hoods. If the unit you have selected does not have
a blower included, one can be purchased separately.
Blower selection will vary based on the volume of air
that needs to be moved and the length and location
of the duct run. For long duct runs with multiple turns
and bends, consider using a more powerful blower. For
the most ef cient air ow exhaust, use a straight run or
as few elbows as possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation,
these blowers can be mounted on the roof or exterior
wall of your home. An exterior installation may be
more appealing to reduce noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are
mounted along the duct line anywhere between the
kitchen and the exterior wall. If you have easy access
to your duct line (in an attic, for example), this may be
an appealing option.
Integrated Blowers (VTI series)
These blowers are purchased separately and
integrated into the hood or onto the downdraft unit at
the time of installation. This option allows you to select
your ideal hood with the exact power you require.
Proper performance is dependent upon proper ducting. Use a quali ed and
trained installer. Local building codes may require the use of make-up air
systems when using ducted ventilation systems greater than speci ed CFM of
air movement. The speci ed CFM varies from locale to locale. Consult your
HVAC professional for speci c requirements in your area.
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.
Transitions, elbows and wall or roof caps are all factors that will add more
static pressure, therefore increasing your equivalent duct run.
INSTALLATION NOTE: Professional Rangetops and Ranges require that
minimum distances be maintained from the cooking surface to combustible
materials (i.e. a wood covering around the insert). These minimum distances
range from 30" to 36" and can vary from product to product and by
manufacturer. Refer to the installation manual of the rangetop or range
prior to the design and installation of the custom hood insert.
WARRANTY
Limited warranty parts and labor (2 year).
See page 302 for additional warranty details.
1.800.735.4328 | THERMADOR.COM
179
Page 51
VENTILATION
CUSTOM INSERT (36"/48"/54")
VCIN36JP / VCIN48JP / VCIN54JP
PROFESSIONAL
VCIN36JP – 36-Inch
VCIN48JP – 48-Inch
VCIN54JP – 54-Inch
Custom hood insert for use within wall
or island custom hood applications
SPECIFICATIONS
Available Hood Widths 36" / 48" / 54"
BlowerSold Separately
Duct Size at Discharge10" Round
Ducting DirectionVertical
Dishwasher-safe Filters Stainless Steel Baf es
Halogen Lighting
12 V, 20 Watt Max.,
G-4 Base, Included
Electrical120V AC, 60Hz
See Blower Options Table
36"– 2 Bulbs
48" / 54"– 4 Bulbs
VCIN36JP / VCIN48JP / VCIN54JP
PERFORMANCE
- Suitable for wall or island applications
- Three fan speeds
- Auto function senses heat from the cooking surface and adjusts
fan speeds
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dishwasher-safe stainless steel baf e lters
- Filter systems are highly ef cient at capturing grease
- Deep capture area allows for ef cient capture of smoke and steam
- Powerfully Quiet
- 10" duct outlet
DESIGN
- Stainless steel button controls
- Halogen lighting spotlights your best recipes
- Remote control accessory
®
ventilation systems
ROOF JACK, WALL CAP & TRANSITION
Roof Jack – RJ3108-Inch Wall Cap–WC8Wall Cap – WC31010-Inch Wall Cap–WC10Transition
ACCESSORIES
Custom Hood Liners
LINER236 For 36" Insert VCIN36JP
LINER248 For 48" Insert VCIN48JP
LINER254 For 54" Insert VCIN54JP
32
7
/16
44
” (1129mm)
7
1
/2
1
(38mm)
”
23
5
/16
” (592mm)
50
/16
” (1281mm)
- Stainless steel custom
hood liners to protect
the exterior base of
custom insert
7
/16
” (824mm)
” (995mm)
3
/16
39
” (1300mm)
/16
3
” (1453mm)
51
/16
3
57
5
/8
”
20
(524mm)
Cabinet Trim
11
/16
” (17mm)
Remote Control Panel
VCI2REMKS
- Stainless steel nish
- Cable-connected to
blower and hood controls
- Cable length 30 ft.
5
1
/16
7
/16
8
332
Stainless Steel
Backsplash
PA36JBS 36" wide
PA48JBS 48" wide
5
3
/16
84
1
13
/16
180
Page 52
VENTILATION
CUSTOM INSERT (36"/48"/54")
VCIN36JP / VCIN48JP / VCIN54JP
VENTILATION — CUSTOM INSERTS
INSTALLATION OPTIONS
Thermador Custom Hood Inserts within custom hood
applications create a seamless design with wall or island
applications.
Thermador Professional Series Custom Hood Inserts may
be installed above a Thermador Professional Cooktop or
Range to create a convenient cooking center. Refer to
the appropriate section for additional speci cations.
Hood installation height above a cooktop can vary.
Professional Rangetops and Ranges require that
minimum distances be maintained from the cooking
surface to combustible materials (i.e. a wood covering
around the insert). These minimum distances range from
30" to 36" and can vary from product to product and
by manufacturer. Refer to the installation manual of the
rangetop or range prior to the design and installation of
the custom hood insert.
These hoods are designed to be used for vertical
discharge. A blower must be purchased separately.
BLOWER OPTIONS (for VCIN__JP)
REMOTE
VTR630D – 600 CFM Use RFPLT600 in
roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in
roof-mount applications
VTR1330E – 1300 CFM Use RFPLT1000 in
roof-mount applications
INLINE
VTI610D – 600 CFM
VTI1010D – 1000 CFM
INTEGRATED
VTN630C – 600 CFM
VTN1030C– 1000 CFM
See page 177 for further details.
HOOD DIMENSIONS
(See installation manual
for complete planning
instructions)
RFPLT1000
For use with Remote
Blowers VTR1030D
and VTR1330E
1.800.735.4328 | THERMADOR.COM
INLINE (Mounted between kitchen and external wall)
VTI610D – 600 CFMVTI1010D – 1000 CFM
INTEGRATED (Mounted on hood)
VTN630C – 600 CFM
VTN1030C – 1000 CFM
181
Page 53
VENTILATION
CUSTOM INSERT WITH BLOWER (36"/48"/54")
VCIB36JP / VCIB48JP / VCIB54JP
VCIB36JP / VCIB48JP / VCIB54JP
PERFORMANCE
- Suitable for wall or island applications
- Three fan speeds
- Auto function senses heat from the cooking surface and adjusts
fan speeds
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
PROFESSIONAL
VCIB36JP – 36-Inch
VCIB48JP – 48-Inch
VCIB54JP – 54-Inch
Custom hood insert for use within wall
or island custom hood applications
SPECIFICATIONS
Available Hood Widths 36" / 48" / 54"
BlowerIntegrated 1000 CFM
Duct Size at Discharge10" Round
Ducting DirectionVertical
Dishwasher-safe Filters Stainless Steel Baf es
Halogen Lighting
12 V, 20 Watt Max.,
G-4 Base, Included
Electrical120V AC, 60Hz
Blower Included
36"– 2 Bulbs
48" / 54"– 4 Bulbs
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dishwasher-safe stainless steel baf e lters
- Filter systems are highly ef cient at capturing grease
- Deep capture area allows for ef cient capture of smoke and steam
- Powerfully Quiet
- 10" duct outlet
DESIGN
- A unique all in one box solution that includes the hood, a 1,000 CFM
blower, liner, baf e lters, lights, transition and a back-draft damper
- Stainless steel button controls
- Halogen lighting spotlights your best recipes
- Remote control accessory
®
ventilation systems
ROOF JACK, WALL CAP & TRANSITION
Roof Jack – RJ3108-Inch Wall Cap–WC8Wall Cap – WC31010-Inch Wall Cap–WC10Transition
ACCESSORIES
Remote Control Panel
VCI2REMKS
- Stainless steel nish
- Cable-connected to
blower and hood controls
- Cable length 30 ft.
5
3
/16
Stainless Steel
Backsplash
PA36JBS 36" wide
PA48JBS 48" wide
84
1
13
5
1
/16
7
/16
8
/16
332
182
Page 54
VENTILATION
CUSTOM INSERT WITH BLOWER (36"/48"/54")
VCIB36JP / VCIB48JP / VCIB54JP
VENTILATION — CUSTOM INSERTS
INSTALLATION OPTIONS
Thermador Custom Hood Inserts within custom hood
applications create a seamless design with wall or island
applications.
Thermador Professional Series Custom Hood Inserts may
be installed above a Thermador Professional Cooktop or
Range to create a convenient cooking center. Refer to
the appropriate section for additional speci cations.
Hood installation height above a cooktop can vary.
Professional Rangetops and Ranges require that
minimum distances be maintained from the cooking
surface to combustible materials (i.e. a wood covering
around the insert). These minimum distances range from
30" to 36" and can vary from product to product and
by manufacturer. Refer to the installation manual of the
rangetop or range prior to the design and installation of
the custom hood insert.
These hoods are designed to be used for vertical
discharge.
BLOWER PRESSURE CURVES
VCIB__JP
HOOD DIMENSIONS
(See installation manual
for complete planning
instructions)
11
13
1
/16
12
”
/8
5
23
(592mm)
” (283mm)
16
5
/8
” (422mm)
20
5
/8
” (524mm)
/16
”
50
1
/2
1
(38mm)
”
23
5
/16
1
/2
1
(38mm)
” (592mm)
(325mm)
”
3
/4
21
(553mm)
44
7
/16
” (1281mm)
”
32
7
/16
” (1129mm)
7
/16
” (824mm)
39
51
57
39
” (995mm)
3
/16
” (1300mm)
3
/16
” (1453mm)
3
/16
” (995mm)
3
/16
/16
3
51
57
1
/2
4
(114mm)
Cabinet Trim
” (17mm)
11
/16
” (1300mm)
” (1453mm)
/16
3
”
3
” (995mm)
/16
39
3
” (1300mm)
6
1
/
51
3
” (1453mm)
/16
57
5
/8
”
20
(524mm)
Cabinet Trim
11
/16
” (17mm)
NOTE: All measurements are made with 3 ft. straight
duct, 90° bend and 1 ft. straight duct at exhaust. These
are NOT free blowing measurements.
CUTOUT DIMENSIONS WHEN USING A LINER
3
/4
39
” (1010mm)
3
/4
” (1315mm)
51
3
/4
”” (1467mm)
57
5
/8
” (16mm)
7
/8
23
” (606mm)
CUTOUT DIMENSIONS WHEN NOT USING A LINER
15
/16
32
” (836mm)
15
/16
” (1141mm)
44
15
/16
” (1294mm)
50
5
/8
” (16mm)
1
/4
” (540mm)
21
1.800.735.4328 | THERMADOR.COM
183
Page 55
VENTILATION
CUSTOM INSERT (30"/36"/48")
VCI230DS / VCI236DS / VCI248DS
MASTERPIECE
VCI230DS – 30-Inch
VCI236DS – 36-Inch
VCI248DS – 48-Inch
Custom hood insert for use within wall
or island custom hood applications
VCI230DS / VCI236DS / VCI248DS
PERFORMANCE
- Suitable for wall or island applications
- Three fan speeds
- Built-in ‘Clean Filter‘ reminder light illuminates after 40 hours
of operation
- Delayed shut-off tackles lingering odors for up to 10 minutes
- Dishwasher-safe aluminum mesh lters
- Filter systems are highly ef cient at capturing grease
- Deep capture area allows for ef cient capture of smoke and steam
- Powerfully Quiet
- 10" Round duct size
- Vertical ducting direction
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
- Accessories include: Liner, Remote Control and Stainless Steel
Baf e Filters
DESIGN
- Stainless steel button controls
- Halogen lighting spotlights your best recipes
®
ventilation systems
SPECIFICATIONS
Available Hood Widths 30" / 36" / 48"
BlowerSold Separately —
Duct Size at Discharge10" Round
Ducting DirectionVertical
Dishwasher-safe Filters Mesh (Baf e lters sold
Halogen Lighting
120 Volt, 20 Watt Max.,
G-4 Base, Included
Electrical120V AC, 60Hz
See Blower Options Table
as an accessory)
30" / 36" – 2 Bulbs
48"– 4 Bulbs
ACCESSORIES
Custom Hood Liners
LINER30 for 30" Insert
LINER36 for 36" Insert
LINER48 for 48" Insert
- Stainless steel custom
hood liners to protect the
exterior base of custom insert
- Unique low pro le design maximizes
grease capture
- Dishwasher-safe for easy cleanup
184
Page 56
VENTILATION
CUSTOM INSERT (30"/36"/48")
VCI230DS / VCI236DS / VCI248DS
VENTILATION — CUSTOM INSERTS
VENTILATION — CUSTOM INSERTS
INSTALLATION OPTIONS
Thermador Custom Hood Inserts within custom hood
applications create a seamless design with wall or island
applications.
Thermador Professional Series Custom Hood Inserts may
be installed above a Thermador Professional Cooktop or
Range to create a convenient cooking center. Refer to
the appropriate section for additional speci cations.
Hood installation height above a cooktop can vary.
Professional Rangetops and Ranges require that
minimum distances be maintained from the cooking
surface to combustible materials (i.e. a wood covering
around the insert). These minimum distances range from
30" to 36" and can vary from product to product and
by manufacturer. Refer to the installation manual of the
rangetop or range prior to the design and installation of
the custom hood insert.
These hoods are designed to be used for vertical
discharge. A blower must be purchased separately.
BLOWER OPTIONS
REMOTE
VTR630D – 600 CFM Use RFPLT600 in
roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in
roof-mount applications
VTR1330E – 1300 CFM Use RFPLT1000 in
roof-mount applications
INLINE
VTI610D – 600 CFM
VTI1010D* – 1000 CFM
INTEGRATED
VTI610D – 600 CFM Inline blower can be used
VTI1010D* – 1000 CFM Inline blower can be used
See pages 134-135 for further details.
* Please visit thermador.com for tips & hints on installation of VTI1010D as
INLINE (Mounted between kitchen and external wall)
& INTEGRATED (Mounted on hood)
VTI610D – 600 CFMVTI1010D – 1000 CFM
REMOTE BLOWER ACCESSORIES
RFPLT600
For use with Remote
Blower VTR630D
1.800.735.4328 | THERMADOR.COM
* Please refer to thermador.com for tips and hints on installation of VTI1010D as an integrated solution
RFPLT1000
For use with Remote
Blowers VTR1030D
and VTR1330E
185
Page 57
MODELS SHOWN: UCVM36FS 36-INCH DOWNDRAFT WITH CIT365KM INDUCTION COOKTOP186
Page 58
VENTILATION
DOWNDRAFT
If you prefer a concealed look, choose a Thermador Downdraft Ventilation Unit, which offers
space ef ciency when a hood is not preferred. The full-face lter combines a lter with a splatter
shield in one easy-to-remove, dishwasher-safe element. Thermador invented the rst retractable
downdraft, and was also the rst to introduce a recirculation option for downdrafts—making
ventilation possible in any kitchen.
VENTILATION — DOWNDRAFT
1.800.735.4328 | THERMADOR.COM
187
Page 59
DOWNDRAFT
FEATURES & BENEFITS
FULL 13-INCH RISE
With an over 13-inch intake, the UCVM rises well above even the
tallest pans. This protects against splatters when cooking and provides
better performance in capturing steam and smoke — even from the
front burners.
DOWNDRAFT RECIRCULATION OPTION
Downdraft recirculation is now available for island or wall applications.
Combine the performance of the UCVM Downdraft with the odor- and
grease-capturing lters in the Recirculation Module for the perfect
ventilation combination for anywhere in your kitchen.
FULL-FACE FILTERS
Full-face lters combine a lter with a splatter shield in one easyto-remove, dishwasher-safe element. These lters maximize grease
capture without affecting air ow.
PLANNING INFORMATION
MODEL OPTIONS
Thermador Downdraft Hoods are available in 30 and 36-inch
widths to t your kitchen plans and are meticulously crafted for
both function and design. Be sure to reference the correct model
information in this design guide.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Downdraft Hood is properly installed
and grounded by a quali ed technician. Installation, electrical
connections and grounding must comply with all applicable
local codes.
REQUIRED CIRCUIT
MODEL
UCVM30FS, UCVM36FS15 Amp
BREAKER
120V AC, 60 Hz
INSTALLATION CONSIDERATIONS
The information in this design guide provides key features,
product dimensions, cutouts and installation speci cations.
Before installing a Thermador Downdraft Hood, be sure to verify
the cutout dimensions and electrical connections. Also, always
consult with the installation manual packed with the product for
complete details before installing.
Thermador Downdraft Hoods may be installed in a wall or island
behind a Thermador non-professional gas, electric or induction
cooktop to create a convenient cooking center. Refer to the
appropriate section for additional speci cations.
HOOD WIDTH
Downdraft ventilation units should be the same width as the
cooking surfaces they are ventilating.
CHOOSING THE CORRECT BLOWER
A variety of interior and exterior blower options (Remote, Inline
or Integrated) are available for Thermador’s Downdraft Hoods.
If the unit you have selected does not have a blower, one can
be purchased separately. Blower selection will vary based on
the volume of air that needs to be moved and the length and
location of the duct run. For long duct runs with multiple turns
and bends, consider using a more powerful blower. For the most
ef cient air ow exhaust, use a straight run or as few elbows
as possible.
188
Remote Blowers (VTR Series)
Depending on your preference and ducting situation, these
blowers can be mounted on the roof or exterior wall of your
home. An exterior installation may be more appealing to reduce
noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are mounted
along the duct line anywhere between the kitchen and the
exterior wall. If you have easy access to your duct line (in an attic,
for example), this may be an appealing option.
Integrated Blowers (VTN series)
These blowers are purchased separately and integrated into the
hood or onto the downdraft unit at the time of installation. This
option allows you to select your ideal hood with the exact power
you require.
Page 60
DOWNDRAFT
FEATURES & BENEFITS
VENTILATION — DOWNDRAFT
CHOOSING THE RIGHT CFM
The power of the cooktop, measured in BTU, is perhaps
the most important factor in determining CFM needs for
a hood. Professional Gas Rangetops generally should
have 1 CFM for every 100 BTU.
You should also consider the cooking space and cooking
style of your client.
• More demanding cooks usually require more exhaust
capacity to handle moisture generated by boiling large
pots of water or the grease and smoke resulting from
grilling or frying. This cooking style could require a hood
or downdraft system with air ow of 600 to 1,300 CFM.
• For those who are used to preparing quick meals in a
relatively small kitchen, a hood with 600 CFM may be
adequate ventilation for the cooking space.
• If the cooking surface is in a peninsula or island, a larger
capacity hood can provide better capture when there
are cross currents and when the hood needs to be
mounted higher. Downdraft ventilation systems are also
a good alternative.
• High heat cooking or aromatic foods may require
additional CFM. Increasing capture area by 3" on each
side is also a recommended way to address this issue.
LENGTH AND SIZE OF DUCTWORK
Do not use exible duct; it creates back pressure/air
turbulence and reduces performance.
Straight runs and gradual turns are best. Use the shortest
route with the fewest turns possible.
Proper performance is dependent upon proper ducting.
Use a quali ed and trained installer. Local building codes
may require the use of make-up air systems when using
ducted ventilation systems greater than speci ed CFM
of air movement. The speci ed CFM varies from locale
to locale. Consult your HVAC professional for speci c
requirements in your area.
BLOWER OPTIONS
REMOTE Requires CV2T6 or CV2T10 Transition
VTR630D – 600 CFM Use RFPLT600 in roof-mount applications
VTR1030D – 1000 CFM Use RFPLT1000 in roof-mount applications
INLINE Requires CV2T6 or CV2T10 Transition
VTI610D – 600 CFM
VTI1010D – 1000 CFM
INTEGRATED
VTN600CV2C – 600 CFM
REMOTE (Mounted to roof or external wall)
VTR630D – 600 CFMVTR1030D–1000 CFM
INLINE (Mounted between kitchen and external wall)
VTI610D – 600 CFMVTI1010D – 1000 CFM
If using a 10" duct, Thermador recommends not
exceeding 150 feet of duct. Transitions, elbows and
wall or roof caps are all factors that will add more static
pressure, therefore increasing your equivalent duct run.
WARRANTY
Limited warranty parts and labor (2 year)
See page 302 for additional warranty details.
REMOTE BLOWER ACCESSORIES
RFPLT600
For use with Remote
Blower VTR630D
1.800.735.4328 | THERMADOR.COM
INTEGRATED (Mounted on hood)
VTN600CV2C – 600 CFM
RFPLT1000
For use with Remote
Blower VTR1030D
189
Page 61
VENTILATION
DOWNDRAFT (30"/36")
UCVM30FS / UCVM36FS
MASTERPIECE
UCVM30FS – 30-Inch
UCVM36FS – 36-Inch
UCVM30FS / UCVM36FS
PERFORMANCE
- Suitable for wall or island applications
- Downdraft rises over 13" to capture steam from the tallest pots
- Downdraft recirculation possible with module RECIRC36DF
- Three fan speeds
- Dishwasher-safe full-face lters also act as a splatter shield
- Filter systems are highly ef cient at capturing grease
- Powerfully Quiet
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
- Comes complete with 2 charcoal lters, 2 venting
grids, and ducting to transition to integrated
blower (blower sold separately)
- For toekick heights of 4" or taller
- Wall or island applications
- Easily mounts to integrated blower (VTN600CV2C)
under cooktop
- Toekick/socket can be vented in any direction
- Mounts to base of cabinet; recesses into toekick
- To be used only with Thermador Downdraft and
Integrated Blower
- Replacement lters are ordered as a service item
- Filters should be replaced twice a year
TRANSITIONS
Transition piece required for installation of inline and remote
blowers — downdraft applications only
CV2T6
Transition piece required
for installation of 600 CFM
Inline and Remote Blowers
with 6" duct connections —
downdraft applications only
CV2T10
Improves overall
performance when installing
with Thermador’s 1,000 CFM
Inline or Remote Blowers
with 10" duct connections —
downdraft applications only
6 3/4"
15 1/8"
7
14
Replacement Charcoal Filters
Sold separately as service item #291108
(For use with recirculation module)
14 3/8"
14 3/8"
/
"
1616
Ø 10"
11"
Ø 6"
190
Page 62
VENTILATION
DOWNDRAFT (30"/36")
UCVM30FS / UCVM36FS
VENTILATION — DOWNDRAFT
VENTILATION — DOWNDRAFT
INSTALLATION OPTIONS
The Thermador Downdraft Hood System is
available in 30-inch or 36-inch widths. It is intended
for installation with Thermador non-professional
gas, electric or induction cooktops only.
A Recirculation Kit (RECIRC36DF) can be
purchased separately and used in conjunction with
the Integral Blower if ducting to the outside is not
a viable option. Refer to the appropriate section
for additional speci cations.
These hoods are designed to be used for side or
downward discharge.
36 7/8"
(936 mm)
30 7/8"
(784 mm)
CUTOUT DIMENSIONS (TOP VIEW)
36 7/8"
7
30
/8"
36 7/8"
7
30
/8"
1.800.735.4328 | THERMADOR.COM
36 7/8"
30
7
/8"
191
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.