Ventilation Planning Guide
For THERMADOR PROFESSIONAL Ranges,
Rangetops, and Hoods
Models/
Modèles/
Guide de Planification de
Ventilation
Pour les cuisinières, surface de cuisson, et hottes
PROFESSIONAL de THERMADOR
Guía de Planificación de
Ventilación
Para las estufas, placas de cocción, y campanas
PROFESSIONAL de THERMADOR
Modelos:
PRO GRAND DUAL
FUEL RANGES
PRO GRAND GAS
RANGES
PRO HARMONY DUAL
FUEL RANGES
PRO HARMONY GAS
RANGES
PRO RANGETOPS
PRO WALL HOODS
PRO CHIMNEY
HOODS
PRO CUSTOM
INSERT HOODS
Ventilation Planning Guide
It is recommended that a THERMADOR PROFESSIONAL hood is used with a THERMADOR PROFESSIONAL range
or rangetop.
IMPORTANT NOTES:
• See related Thermador Manuals for additional information.
• Thermador recommends not exceeding 50 equivalent length (ft) (15.24 m) of duct.
• Keep duct runs as short and straight as possible. Elbows and transitions fittings reduce air flow efficiency. Back to back
elbows and “S” turns give very poor delivery and are not recommended. A short straight length of duct at the inlet of a remote
blower gives the best delivery.
• For Thermador Pro Ranges applications with a non-approved Thermador hood, the hood and/or blower must be rated for 1
CFM for every 100 BTU on the Range/Rangetop. If the range has a Griddle, add an additional 200 CFM to the estimated
blower capacity. If the range has a Grill, add an additional 400 CFM.
• For island applications, it is recommended to use a hood width that exceeds the width of the range by 6'' (152 mm),
overlapping the range or rangetop by a minimum of 3'' (76 mm) on each end.
• All Blower models referenced may not be compatible with all hoods referenced. Refer to www.thermador.com for a complete
selection of ventilation options, blowers, and accessories.
• A 25 foot extension cable (EXTNCB25) is available for purchase to connect the hood to in-line or remote blowers, if required.
The following range and rangetop ventilation combinations are approved installations.
Range or Rangetop
Model
NOTE – All Range/Hood/Blower combinations below must use minimum 6" diameter duct.
30'' PH30HS, HPWB30FS VTN630*,
NOTE – All Range/Hood/Blower combinations below must use minimum 8" diameter duct.
30'' PH30HS, HPCB36NS, HPCN36NS,
HPWB36FS, PH36GS, PH36HS,
VCIB36JP, VCIN36JP,
36'' without Grill or
Griddle
36'' with Griddle
48'' with Griddle only HPCB48NS, HPCN48NS, HPWB48FS,
NOTE – All Range/Hood/Blower Combinations below must use minimum 10" diameter duct.
36'' With Grill HPCB36NS, HPCN36NS, HPWB36FS,
48'' with Grill
48" with Grill and
Griddle
* Indicates a letter designating the release year.
HPCB36NS, HPCN36NS, HPWB36FS,
PH36GS, PH36HS, VCIB36JP,
VCIN36JP, PH42GS, HPCB48NS,
HPCN48NS, HPWB48FS, PH48GS,
PH48HS, VCIB48JP, VCIN48JP
PH48GS, PH48HS, VCIB48JP,
VCIN48JP, PH54GS, VCIB54JP,
VCIN54JP
PH36GS, PH36HS, VCIB36JP,
VCIN36JP, PH42GS, HPCB48NS,
HPCN48NS, HPWB48FS, PH48GS,
PH48HS, VCIB48JP, VCIN48JP
HPCB48NS, HPCN48NS, HPWB48FS,
PH48GS, PH48HS, VCIB48JP,
VCIN48JP, PH54GS, VCIB54JP,
VCIN54JP
Recommended
Hood Models
Min. Integral
Blower
VTN600*
VTN1000* VTI1010*,
VTN1030*,
VTN1080*,
VTN1000*
VTN1030*,
VTN1080*,
VTN1000*
VTN1030*,
VTN1080*
VTN1030*,
VTN1080*
Min. In-Line or
Remote Blower
VTI610*,
VTR630*
VTR1030*
VTI1010*,
VTR1030*
VTI1010*,
VTR1030*
VTI1010*,
VTR1030*
VTI1010*,
VTR1030*
Other Available
Blowers
N/A
VTN1030*, VTN1080*,
VTI1010*, VTR1030*,
VTR1330*
VTR1330*
VTR1330*
VTR1330*
VTR1330*
9001007032 • Rev. A • 5U063E • © BSH Home Appliances Corporation, 08/14