Thermador HNW36, HNW42, HNW48 Installation Instructions Manual

Page 1
®
READ AND SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
HNW W ALL HOOD
FOR RESIDENTIAL USE ONL Y
NOT TO BE INSTALLED OVER GAS GRILLS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTINST
INSTINST
INST
ALLAALLA
ALLAALLA
ALLA
TION MUST COMPLTION MUST COMPL
TION MUST COMPLTION MUST COMPL
TION MUST COMPL
Y Y
Y Y
Y
WITH WITH
WITH WITH
WITH
ALL LOCALL LOC
ALL LOCALL LOC
ALL LOC
AL CODES.AL CODES.
AL CODES.AL CODES.
AL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s
use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
INSTALLATION:
• Requires remote blower model VTR1000Q or VTR1400Q.
• Requires Transition from 8” duct at hood to 10” duct at remote blower
• Requires 5-wire installation from remote blower to hood.
• Power supply required: 120V, 60Hz, 15A min
FILE # E21958
Page 2
Page 2
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARD­OUS OR EXPLOSIVE MATERI­ALS OR VAPORS.
A. Use this unit only in the
manner intended by the manufacturer. If you have questions, contact the manu­facturer.
B. Before servicing or cleaning
the unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on acciden­tally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Installation work and
electrical wiring must be done by qualified person(s) In accordance with all applicable codes & standards, including fire-rated construction.
D. Sufficient air is needed for
proper combustion and ex­hausting of gases through the flue (chimney) of fuel burning
equipment to prevent back­drafting. Follow the heating equipment manufacturers guideline and safety stan­dards such as those published by the National Fire Protection Association (NFPA), the American Society for Heat- ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
E. Due to size and weight of this
unit two installers are recommended.
F. When cutting or drilling into
wall or ceiling, do not damage electrical wiring and other hidden utilities.
G. CAUTION - To reduce risk of
fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.
H. WARNING - TO REDUCE THE
RISK OF FIRE, USE ONLY METAL DUCT WORK.
I. Install this hood in accor-
dance with all requirements specified by the manufacturer of your cooktop/range.
IMPORTANT SAFETY INSTRUCTIONS
Page 3
Page 3
LES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
AVERTISSEMENT - POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE, OU DE LA BLESSURE AUX PERSONNES, OBSERVER LE SUIVANT:
ATTENTION: SEULEMENT POUR L’UTILISATION D’AÉRATION. NE PAS L’UTILISER POUR ÉPUISER LA VAPEUR OU LES MATIÈRES EXPLOSIVES OU DANGEREUSES.
A. Utiliser cet appareil
seulement dans la manière destinée par le fabricant. Si vous avez des questions, contacter le fabricant.
B. Avant l’entretien ou le
nettoyage de l’appareil, couper le courant au tableau de service, et fermer à clef la moyenne de débrayage de service pour empêcher l’alimentation d’être allumée par hasard. Quand la moyenne de débrayage de service ne peut pas être fermée à clef, attacher une étiquette au tableau de service pour indiquer que l'alimentation a été coupée pour l'entretien.
C. Le Travail d’Installation et de
Câblage Électrique Doit Être Fait Par les Personne(s) Qualifiées Conformément à Tous les Codes & Normes Applicables, y Compris la Construction Calculée à Feu.
D. L’écoulement comburant pour
le fonctionnement sûr du
matériel de la combustion du combustible peut être affecté par le fonctionnement de cet appareil. Suivre la directive des fabricants du matériel chauffant et les normes de sécurité tel que ceux publiées par l’Association du Protec­tion de Feu National (NFPA), et la Société Américaine pour les Ingénieurs de Chauffage, de Réfrigération et de Climatisa- tion (ASHRAE), et les autorités des codes locales.
E. Par suite de la dimension et
le poids de cet appareil, deux installateurs sont recommandés.
F. En coupant ou en forant dans
un mur ou dans un plafond, ne pas endommager le câblage électrique et des autres utilités cachées.
G. Les ventilateurs canalisés
doivent être toujours déchargés à l’extérieur et vers le haut. Ne pas décharger au grenier ou au vide sanitaire.
H. Pour réduire le risque
d’incendie, utiliser seulement le travail du conduit métallique.
I. Installer ce capot conformé-
ment aux toutes exigences spécifiées par le fabricant de votre cooktop/cuisinière.
Page 4
Page 4
D
W
T
H
HNW
Table 1
HEIGHT
H
* Min. Max.
28 1/2" 33" 49 1/4" 28 1/2" 33" 49 1/4" 28 1/2" 33" 49 1/4"
WIDTH
W
36” 42” 48”
DEPTH
D
23 1/4" 23 1/4" 23 1/4"
DUCT
SIZE
8” 8” 8”
CFM
770 770 770
LIGHTS
# O F Total
Watts
2 40W 4 80W 4 80W
TRANSITION
T A**
15 7/8" 4 7/8" 15 7/8" 4 7/8" 15 7/8" 4 7/8"
MODEL #
HNW36 HNW42 HNW48
CARTON
WEIGHT
Pounds
44,9 62,5 70,2
* Height if Upper Telescope Piece is Left Off ** Distance from wall to centerline of transition
Page 5
Page 5
Parts Included with your Hood
Hood Canopy Assembly with
Ventilator and Light Bulbs Installed
Care & Use /Installation Instructions
Registration Card
Filters number depends on model and size
Plastic Transition with Back draft dampers installed
Screws and Drywall An­chors
2 Mounting Hooks
Mounting Templet
2 Piece Duct Cover
8" Starting Collar
Contents Sheet
cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house.
4. Hood installation height above cooktop is the users preference. The closer the hood is to the cooktop the more efficient it will be in capturing of cooking odors, grease and smoke. Thermador recommends the hood be in­stalled 30-36" above the countertop. The lower height may be inconvenient for tall people and large cooking vessels. Check your ceiling height and the hood height maximum before you select your hood.
1. For the most efficient air flow exhaust, use a straight run or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
2. Use flex ducting only to connect rigid duct directly to transitions.
3. COLD WEATHER installa­tions should have an addi­tional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the
CONSIDERATIONS BEFORE INSTALLING HOOD
Parts Not Included with your Hood
HDTR8 Metal Transition if
required.
Duct Tape
1/2" Conduit
Wire Nuts
Plywood Wall Mounting Block
Page 6
Page 6
16
16
Preparation of mounting surface (Drywall)
1. Select a mounting height comfortable for the user and mark on wall behind cooking surface.
2. Mark centerline of cooking surface and draw vertical line from bottom of hood to the ceiling.
3. Tape template, matching center-line and hood bottom as shown in Fig. A.
4. Mark centers of the 6 fastener locations through template on wall then remove template.
5. Mark wall with horizontal line 1" above highest and 1" below lowest fastener location.
6. Find studs behind drywall by tapping wall or using a stud finder. Mark the center of the studs with a vertical line to the right and left of the marked fastener location. Note: 2 x 6's must span at least 2 studs side to side.
7. Cutout drywall along marked lines. Install 2 x 6's between studs firmly flush with stud front. Make sure all mounting screws will anchor to added lumber. Replace drywall and refinish.
8. Attach template to wall using cooking surface centerline and hood installation height as shown in Fig. A
C
L
Fig. A
Fig. B
9. Attach 2 mounting hooks with wood screws to locations marked on template. Remove template.
10. Install duct cover bracket on wall, flush to ceiling, using drywall anchors supplied. See Fig. B.
bottom of hood
Page 7
Page 7
4. Secure hood with 2 screws on top and 2 screws on bottom. See Fig. D.
5. REMOTE VENTILATOR AND DUCT INSTALLATION. Refer to instructions shipped with remote ventilator model VTR1000Q or VTR1400Q for installation of remote blower and ducting. The remote ventilator inlet fits 10" round duct. Transition to 8" round prior to passing through ceiling or wall for duct cover clearance and connecting to the hood transition. Do not use ducting smaller than 8" round.
6. Connect ducting to transition using starter collar provided with hood (See Fig. C). Locate collar screws so they fit into corner of the duct cover. Secure collar to transition and duct with three sheet metal screws each. Seal with duct
tape.
7. Install wiring for remote ventilator and power supply. See electrical installation on page 7.
8. Install duct covers on top of hood as shown in Fig. B. Raise inside cover and attach to duct cover bracket using two sheet metal screws provided.
Appliance Installation:
1. Install transition on top of hood if removed for shipping. Fig. C
2. Hang hood on 2 mounting hooks through the rectangular cutouts on back of hood. Fig. D
3. Level the appliance shown in Fig. D.
13
Starting
Collar
Fig. D
Fig. C
1"
Page 8
Page 8
9. Check all light bulbs to make sure they are secure in their sockets. Turn power on in the service panel. Install filters. Check light and blower operation. Leave this manual for the home owner.
Alternate Installations
Reduced Ceiling Height Installation for HNW model:
The hood may be installed with only the lower part of the duct cover to reduce the overall height. This hood height is signified by * in Table 1.
1. For the duct cover to slide down and engage the top of the hood position the duct cover bracket 1" below the ceiling.
2. Fill in the gap between the ceiling and top of the chimney with a 1" thick piece of wood cut to the inside cross section of the chimney cover.
3. Finish the wood to match the ceiling.
4. Copy the two mounting holes on the sides of the upper
cover to the lower cover.
5. Install lower cover on hood and secure to mounting bracket with two sheet metal screws.
Rear discharge
For rear discharge a 90 degree elbow may be installed immedi­ately above the hood. The distance from the bottom of the hood to top of the transition is
provided by dimension "T" in Table 1.
Page 9
Page 9
ELECTRICAL INSTALLATION
Warning: Switch power off at service panel and lock the service disconnecting means before wiring this unit.
Wiring Remote Ventilator VTR1000Q or VTR1400Q:
1. Run five wires #14 AWG
(black, white, blue, red, and green) in 1/2” conduit from the remote ventilator to the hood.
2. Install conduit connector
at the end of the conduit. Remove the knockout on top of the junction box. Attach conduit connector to the junction box.
3. Use the four wire bundle
and ground wire in the junction box for connecting to the remote ventilator wires. Connect black wire from the remote ventilator to the black wire in the junction box, red to red, blue to blue, white to white, and green to green. Do not
connect to the power supply wire bundle containing a black and white wire. See Figure E.
Wiring To Power Supply:
1. Installation requires a 15A circuit. Run three
wires: black, white, and green using #14 AWG from the service panel to the junction box.
2. Remove junction box cover
HNW
as shown in Figure E.
3. Remove the knockout and
install
1
/2” conduit
connector.
4. Connect black wire from
service panel to black in junction box, white to white, and green to green. See Figure E.
5. Close junction box cover.
Fig. E