Thermador HNW Installation Instructions

®
INSTALLA TION INSTRUCTIONS
HNW W ALL HOOD
FOR RESIDENTIAL USE ONL Y
NOT TO BE INSTALLED OVER GAS GRILLS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTINST
ALLAALLA
INST
INSTINST
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
INSTALLATION:
• Requires remote blower model VTR1000Q or VTR1400Q.
• Requires Transition from 8” duct at hood to 10” duct at remote blower
• Requires 5-wire installation from remote blower to hood.
• Power supply required: 120V, 60Hz, 15A min
TION MUST COMPLTION MUST COMPL
ALLA
TION MUST COMPL
ALLAALLA
TION MUST COMPLTION MUST COMPL
use.
Y Y
WITH WITH
Y
WITH
Y Y
WITH WITH
ALL LOCALL LOC
ALL LOC
ALL LOCALL LOC
AL CODES.AL CODES.
AL CODES.
AL CODES.AL CODES.
FILE # E21958
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARD­OUS OR EXPLOSIVE MATERI­ALS OR VAPORS.
A. Use this unit only in the
manner intended by the manufacturer. If you have questions, contact the manu­facturer.
B. Before servicing or cleaning
the unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on acciden­tally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Installation work and
electrical wiring must be done by qualified person(s) In accordance with all applicable codes & standards, including fire-rated construction.
equipment to prevent back­drafting. Follow the heating equipment manufacturers guideline and safety stan­dards such as those published by the National Fire Protection Association (NFPA), the American Society for Heat- ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
E. Due to size and weight of this
unit two installers are recommended.
F. When cutting or drilling into
wall or ceiling, do not damage electrical wiring and other hidden utilities.
G. CAUTION - To reduce risk of
fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.
H. WARNING - TO REDUCE THE
RISK OF FIRE, USE ONLY METAL DUCT WORK.
I. Install this hood in accor-
dance with all requirements specified by the manufacturer of your cooktop/range.
D. Sufficient air is needed for
proper combustion and ex­hausting of gases through the flue (chimney) of fuel burning
Page 2
LES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
AVERTISSEMENT - POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE, OU DE LA BLESSURE AUX PERSONNES, OBSERVER LE SUIVANT:
ATTENTION: SEULEMENT POUR L’UTILISATION D’AÉRATION. NE PAS L’UTILISER POUR ÉPUISER LA VAPEUR OU LES MATIÈRES EXPLOSIVES OU DANGEREUSES.
A. Utiliser cet appareil
seulement dans la manière destinée par le fabricant. Si vous avez des questions, contacter le fabricant.
B. Avant l’entretien ou le
nettoyage de l’appareil, couper le courant au tableau de service, et fermer à clef la moyenne de débrayage de service pour empêcher l’alimentation d’être allumée par hasard. Quand la moyenne de débrayage de service ne peut pas être fermée à clef, attacher une étiquette au tableau de service pour indiquer que l'alimentation a été coupée pour l'entretien.
C. Le Travail d’Installation et de
Câblage Électrique Doit Être Fait Par les Personne(s) Qualifiées Conformément à Tous les Codes & Normes Applicables, y Compris la Construction Calculée à Feu.
D. L’écoulement comburant pour
le fonctionnement sûr du
matériel de la combustion du combustible peut être affecté par le fonctionnement de cet appareil. Suivre la directive des fabricants du matériel chauffant et les normes de sécurité tel que ceux publiées par l’Association du Protec­tion de Feu National (NFPA), et la Société Américaine pour les Ingénieurs de Chauffage, de Réfrigération et de Climatisa- tion (ASHRAE), et les autorités des codes locales.
E. Par suite de la dimension et
le poids de cet appareil, deux installateurs sont recommandés.
F. En coupant ou en forant dans
un mur ou dans un plafond, ne pas endommager le câblage électrique et des autres utilités cachées.
G. Les ventilateurs canalisés
doivent être toujours déchargés à l’extérieur et vers le haut. Ne pas décharger au grenier ou au vide sanitaire.
H. Pour réduire le risque
d’incendie, utiliser seulement le travail du conduit métallique.
I. Installer ce capot conformé-
ment aux toutes exigences spécifiées par le fabricant de votre cooktop/cuisinière.