Thermador Glass Ceramic Cooktops
Models: CEM304, CEM365, CEM456
Installation Instructions Models: CEM304, CEM365, CEM456
TABLE OF CONTENTS *
*NOTE: The blocked letters, such as A, sho wn below , r efer to illustrations on
Pages 2 & 4. Match these to the related text pages.
Overall Dimensions A ................................................................................................2
Power Supply B ............................................................................................................2
Cabinet Preparation and Clearances C ..............................................................2 , 3
Junction Box Location D ............................................................................................2
Countertop Cutout Dimensions E .........................................................................2
Installing the Cooktop F ............................................................................................4
Secure Cooktop to Countertop G .........................................................................4
Solid Surface Countertop Installs H ........................................................................4
Installation above a Single Oven I, J, K, and L.................................................4
Electrical Connection..................................................................................................5
IMPORTANT: Save these instructions for Local Electrical Inspector’s use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
OVERALL DIMENSIONS A
See Illustration A, Page 2. These dimensions are ov erall.
POWER SUPPLY B
ELECTRICAL POWER CONNECTION FOR COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts, 3 wire, 60 Hz, with the following circuit breaker requirements: Model CEM304 at 30 Amps; Model CEM365 at 40 Amps or Model CEM456 at 50 Amps
JUNCTION BOX LOCATION D
Plan the installation of the unit so that the location of the junction box is within 3 feet of the right rear of the cooktop bottom. It must be accessible from the front of the cabinet. (An exception to this location would be for a cooktop installation over a single electric oven In that situation, refer to Pages 4 and 5 and Figures I, J, K and L.
Install a junction box (not supplied), below the counter top within 3 feet of flexible conduit (supplied) located at the right rear corner of the cooktop rough-in bo x.
PAGE 1
Installation Instructions
Models: CEM304, CEM365, CEM456
CEM304 B 19-7/8" / (505 mm) 20" / (508 mm)
C28
-3
/4" / (731 mm) 28-7/8" / (734 mm)
CEM365 B 19-7/8" / (505 mm) 20" / (508 mm)
C34
-3
/4" / (883 mm) 34-7/8" / (886 mm)
CEM456 B 19-7/8" / (505 mm) 20" / (508 mm)
C43
-3
/4" / (1111 mm) 43-7/8" / (1114 mm)
PAGE 2