Texas Instruments SN64BCT245DW, SN64BCT245DWR, SN64BCT245N Datasheet

SN64BCT245
OCTAL BUS TRANSCEIVER
WITH 3-STATE OUTPUTS
SCBS040A – JANUARY 1990 – REVISED JANUAR Y 1994
Copyright 1994, Texas Instruments Incorporated
3–1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
BiCMOS Design Significantly Reduces I
3-State True Outputs Drive Bus Lines
Directly
High-Impedance State During Power Up
and Power Down
ESD Protection Exceeds 2000 V
Per MIL-STD-883C, Method 3015
Package Options Include Plastic
Small-Outline (DW) Packages and Standard Plastic 300-mil DIPs (N)
description
This octal bus transceiver is designed for asynchronous communication between data buses. The devices transmit data from the A bus to the B bus or from the B bus to the A bus depending upon the logic level at the direction-control (DIR) input. The output-enable (OE
) input can be used to disable the device
so the buses are effectively isolated. The outputs are in a high-impedance state during power up and power down while the supply voltage is less
than approximately 3 V. The SN64BCT245 is characterized for operation from –40°C to 85°C and 0°C to 70°C.
FUNCTION TABLE
INPUTS
OE DIR
OPERATION
L L B data to A bus L H A data to B bus H X Isolation
logic symbol
logic diagram (positive logic)
A5
6
A6
7
A7
8
A8
9
A2
3
A3
4
A4
5
OE
A1
2
G3
19
3EN2[AB]
B5
14
B6
13
B7
12
B8
11
B1
18
B2
17
B3
16
B4
15
3EN1[BA]
1
DIR
DIR
OE
A1
B1
1
2
18
19
To Seven Other Channels
1
2
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
1 2 3 4 5 6 7 8 9 10
20 19 18 17 16 15 14 13 12 11
DIR
A1 A2 A3 A4 A5 A6 A7 A8
GND
V
CC
OE B1 B2 B3 B4 B5 B6 B7 B8
DW OR N PACKAGE
(TOP VIEW)
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN64BCT245 OCTAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
SCBS040A – JANUARY 1990 – REVISED JANUAR Y 1994
3–2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
– 0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, VI (see Note 1) – 0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the disabled or power-off state, V
O
– 0.5 V to 5.5 V. . . . . . . . . . . . . . .
Voltage range applied to any output in the high state, V
O
– 0.5 V to V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current into any output in the low state 128 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range – 40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range – 65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
recommended operating conditions
MIN NOM MAX UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
IK
Input clamp current –18 mA
p
A1–A8 –3
IOHHigh-level output current
B1–B8 –15
mA
p
A1–A8 24
IOLLow-level output current
B1–B8 64
mA
T
A
Operating free-air temperature –40 85 °C
Loading...