Texas Instruments SN54ALS253J, SN74ALS253D, SN74ALS253DR, SN74ALS253N, SNJ54ALS253FK Datasheet

...
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
Copyright 1994, Texas Instruments Incorporated
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3-State Versions of the ′ALS153 and
Permits Multiplexing From n Lines to
One Line
Performs Parallel-to-Serial Conversion
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs
description
These data selectors/multiplexers contain inverters and drivers to supply full binary decoding data selection to the AND-OR gates. Separate output control inputs are provided for each of the two 4-line sections.
The 3-state outputs can interface with and drive data lines of bus-organized systems. With all but one of the common outputs disabled (at a high-impedance state), the low impedance of the single enabled output drives the bus line to a high or low logic level. Each output has its own output-enable (OE
) input. The output is disabled
when OE
is high.
The SN54ALS253 is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74ALS253 and SN74AS253A are characterized for operation from 0°C to 70°C.
FUNCTION TABLE
INPUTS
SELECT
DATA
OUTPUT
B A C0 C1 C2 C3
OE
Y
X X X X X X H Z
L LLXXXL L LLHXXXL H LHXLXXL L
LHXHXXL H HLXXLXL L HLXXHXL H HHXXXLL L HHXXXHL H
Select inputs A and B are common to both sections.
SN54ALS253 ...J PACKAGE
SN74ALS253, SN74AS253A ...D OR N PACKAGE
(TOP VIEW)
3212019
910111213
4 5 6 7 8
18 17 16 15 14
A 2C3 NC 2C2 2C1
1C3 1C2
NC 1C1 1C0
SN54ALS253 . . . FK PACKAGE
(TOP VIEW)
B
1OE
NC
2Y
2C0
2OE
1Y
GND
NC
NC – No internal connection
V
CC
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10
9
1OE
B 1C3 1C2 1C1 1C0
1Y
GND
V
CC
2OE A 2C3 2C2 2C1 2C0 2Y
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN54ALS253, SN74ALS253, SN74AS253A DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic symbol
G
MUX
0 3
0
14
A
1
2
B
EN
1
15
1Y
7
0
6
1C0
1
5
1C1
2
4
1C2
3
3
1C3
10
2C0
11
2C1
12
2C2
13
2C3
2Y
9
1OE
2OE
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
logic diagram (positive logic)
Data 2
Select
Data 1
2OE
2C3
2C2
2C1
2C0
A
B
1C3
1C2
1C1
1C0
1OE
1Y
1
6
5
4
3
2
14
10
11
12
13
15
7
2Y
9
Pin numbers shown are for the D, J, and N packages.
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage applied to a disabled 3-state output 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54ALS253 –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS253 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS253 SN74ALS253
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.7 0.8 V
I
OH
High-level output current –1 –2.6 mA
I
OL
Low-level output current 12 24 mA
T
A
Operating free-air temperature –55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN54ALS253 SN74ALS253
PARAMETER
TEST CONDITIONS
MIN TYP‡MAX MIN TYP‡MAX
UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.5 –1.5 V VCC = 4.5 V to 5.5 V, IOH = –0.4 mA VCC –2 VCC –2
V
OH
IOH = –1 mA 2.4 3.3
V
V
CC
= 4.5
V
IOH = –2.6 mA 2.4 3.2 IOL = 12 mA 0.25 0.4 0.25 0.4
V
OL
V
CC
= 4.5
V
IOL = 24 mA 0.35 0.5
V
I
OZH
VCC = 5.5 V, VO = 2.7 V 20 20 µA
I
OZL
VCC = 5.5 V, VO = 0.4 V –20 –20 µA
I
I
VCC = 5.5 V, VI = 7 V 0.1 0.1 mA
I
IH
VCC = 5.5 V, VI = 2.7 V 20 20 µA
I
IL
VCC = 5.5 V, VI = 0.4 V –0.1 –0.1 mA
I
O
§
VCC = 5.5 V, VO = 2.25 V –20 –112 –30 –112 mA
Outputs high 6.5 12 6.5 12
I
CC
V
CC
= 5.5
V
Outputs disabled 7.5 14 7.5 14
mA
All typical values are at VCC = 5 V, TA = 25°C.
§
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
SN54ALS253, SN74ALS253, SN74AS253A DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500
,
R2 = 500 Ω, TA = MIN to MAX
UNIT
SN54ALS253 SN74ALS253
MIN MAX MIN MAX
t
PLH
5 30 5 21
t
PHL
A or B
Any Y
5 27 5 21
ns
t
PLH
Data
2 15 2 10
t
PHL
(any C)
Any Y
3 18 3 14
ns
t
PZH
3 20 3 14
t
PZL
OE
Any Y
2 19 4 16
ns
t
PHZ
2 12 2 10
t
PLZ
OE
Any Y
2 18 2 14
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN74AS253A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74AS253A
MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
OH
High-level output current –15 mA
I
OL
Low-level output current 48 mA
T
A
Operating free-air temperature 0 70 °C
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN74AS253A
PARAMETER
TEST CONDITIONS
MIN TYP†MAX
UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.2 V VCC = 4.5 V to 5.5 V, IOH = –2 mA VCC –2
V
OH
VCC = 4.5 V, IOH = –15 mA 2.4 3.2
V
V
OL
VCC = 4.5 V, IOL = 48 mA 0.35 0.5 V
I
OZH
VCC = 5.5 V, VO = 2.7 V 50 µA
I
OZL
VCC = 5.5 V, VO = 0.4 V –50 µA
A, B
0.2
I
I
All others
V
CC
= 5.5 V,
V
I
= 7
V
0.1
mA
A, B
40
I
IH
All others
V
CC
=
5.5 V
,
V
I
=
2.7 V
20
µ
A
A, B
–1
I
IL
All others
V
CC
= 5.5 V,
V
I
= 0.4
V
–0.5
mA
I
O
VCC = 5.5 V, VO = 2.25 V –30 –112 mA
Outputs high 18 29
I
CC
VCC = 5.5 V
Outputs low 20 32
mA
Outputs disabled 21 33
All typical values are at VCC = 5 V, TA = 25°C.
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500
,
R2 = 500 Ω, TA = MIN to MAX
§
UNIT
SN74AS253A
MIN MAX
t
PLH
3 13.5
t
PHL
A or B
Y
3 11.5
ns
t
PLH
Data
2.5 7.5
t
PHL
(any C)
Y
2.5 8
ns
t
PZH
2 12.5
t
PZL
OE
Any Y
2.5 11.5
ns
t
PHZ
1 6
t
PLZ
OE
Any Y
1 7
ns
§
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
SN54ALS253, SN74ALS253, SN74AS253A DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
t
PHZ
t
PLZ
t
PHL
t
PLH
0.3 V
t
PZL
t
PZH
t
PLH
t
PHL
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
From Output
Under Test
Test Point
R1
S1
C
L
(see Note A)
7 V
1.3 V
1.3 V1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
t
h
t
su
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
Timing
Input
Data
Input
1.3 V 1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
High-Level
Pulse
Low-Level
Pulse
t
w
VOLTAGE WAVEFORMS
PULSE DURATIONS
Input
Out-of-Phase
Output
(see Note C)
1.3 V 1.3 V
1.3 V1.3 V
1.3 V 1.3 V
1.3 V1.3 V
1.3 V
1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
V
OL
V
OH
V
OH
V
OL
Output
Control
(low-level
enabling)
Waveform 1
S1 Closed
(see Note B)
Waveform 2
S1 Open
(see Note B)
[
0 V
V
OH
V
OL
[
3.5 V
In-Phase
Output
0.3 V
1.3 V 1.3 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
R2
V
CC
R
L
Test Point
From Output
Under Test
C
L
(see Note A)
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
From Output
Under Test
Test Point
C
L
(see Note A)
R
L
RL = R1 = R2
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. When measuring propagation delay items of 3-state outputs, switch S1 is open. D. All input pulses have the following characteristics: PRR 1 MHz, tr = tf = 2 ns, duty cycle = 50%. E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICA TIONS IS UNDERST OOD TO BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated
Loading...