Texas Instruments SN54ALS03BJ, SN74ALS03BD, SN74ALS03BDR, SN74ALS03BN, SNJ54ALS03BFK Datasheet

...
SN54ALS03B, SN74ALS03B
QUADRUPLE 2-INPUT POSITIVE-NAND BUFFERS
WITH OPEN-COLLECTOR OUTPUTS
SDAS013B – MARCH 1984 – REVISED DECEMBER 1994
Copyright 1994, Texas Instruments Incorporated
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Package Options Include Plastic
description
These devices contain four independent 2-input positive-NAND buffers. They perform the Boolean functions Y = A
B or Y = A + B in positive logic. The open-collector outputs require pullup resistors to perform correctly . These outputs may be connected to other open-collector outputs to implement active-low wired-OR or active-high wired-AND functions. Open-collector devices are often used to generate high V
OH
levels.
The SN54ALS03B is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74ALS03B is characterized for operation from 0°C to 70°C.
FUNCTION TABLE (each gate)
INPUTS
OUTPUT
A B
Y
H H L L XH XLH
logic symbol
logic diagram (positive logic)
1
1A
2
1B
4
2A
5
2B
9
3A
10
3B
12
4A
13
4B
&
1Y
3
2Y
6
3Y
8
4Y
11
1Y
3
1
1A
2
1B
2Y
6
4
2A
5
2B
3Y
8
9
3A
10
3B
4Y
11
12
4A
13
4B
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
SN54ALS03B ...J PACKAGE
SN74ALS03B ...D OR N PACKAGE
(TOP VIEW)
1 2 3 4 5 6 7
14 13 12 11 10
9 8
1A 1B 1Y 2A 2B 2Y
GND
V
CC
4B 4A 4Y 3B 3A 3Y
SN54ALS03B . . . FK PACKAGE
(TOP VIEW)
3 2 1 20 19
9 10 11 12 13
4 5 6 7 8
18 17 16 15 14
4A NC 4Y NC 3B
1Y
NC
2A
NC
2B
1B1ANC
3Y
3A
V
4B
2Y
NC
CC
NC – No internal connection
GND
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN54ALS03B, SN74ALS03B QUADRUPLE 2-INPUT POSITIVE-NAND BUFFERS WITH OPEN-COLLECTOR OUTPUTS
SDAS013B – MARCH 1984 – REVISED DECEMBER 1994
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Off-state output voltage 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54ALS03B –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS03B 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS03B SN74ALS03B
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.7 0.8 V
V
OH
High-level output voltage 5.5 5.5 V
I
OL
Low-level output current 4 8 mA
T
A
Operating free-air temperature –55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN54ALS03B SN74ALS03B
PARAMETER
TEST CONDITIONS
MIN TYP‡MAX MIN TYP‡MAX
UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.5 –1.5 V
IOL = 4 mA 0.25 0.4 0.25 0.4
V
OL
V
CC
= 4.5
V
IOL = 8 mA 0.35 0.5
V
I
I
VCC = 5.5 V, VI = 7 V 0.1 0.1 mA
I
IH
VCC = 5.5 V, VI = 2.7 V 20 20 µA
I
IL
VCC = 5.5 V, VI = 0.4 V –0.1 –0.1 mA
I
OH
VCC = 4.5 V, VOH = 5.5 V 0.1 0.1 mA
I
CCH
VCC = 5.5 V, VI = 0 0.43 0.85 0.43 0.85 mA
I
CCL
VCC = 5.5 V, VI = 4.5 V 1.62 3 1.62 4 mA
All typical values are at VCC = 5 V, TA = 25°C.
switching characteristics (see Figure 1)
PARAMETER
FROM
(
INPUT
)
TO
(
OUTPUT
)
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 2 k, TA = MIN to MAX
§
UNIT
(INPUT)
(OUTPUT)
SN54ALS03B SN74ALS03B
MIN MAX MIN MAX
t
PLH
20 59 20 50
t
PHL
A or B
Y
3 23 3 13
ns
§
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
Loading...