Figure 12: Turn Off HF Transmitter .............. ............................. .........................10
Figure 13: Turn Off LF Transmitter.. .............................. .............................. ......11
Figure 14: Com Port Closure............... .............................. .............................. ......12
Figure 15: Successful Com Port Closure............................................. ..................13
Figure 16: FCC Label for S4110R MFR Evaluation Kit......................................13
Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit...........14
Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit .........14
User Guide Test Control Software
Page 2 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
1. Purpose
The purpose of this document is to demonstrate the Test Control software for
the S4110 MFR Evaluation Kit..
2. Hardware Set up
2.1 S4110 MFR Evaluation Kit Hardware supplied
1) S4110 MFR Evaluation Kit Black Box Reader
2) S4110 MFR Evaluation Kit Software Development Kit (SDK) Reader
3) Power Supply, 9.0 Vdc 1.0 A, Globtek Part Number:
DC Power connector
+9 Vdc is center pin
Revision:
S P E C I F I C A T I O N
TR9CD1700LCP-Y
Globtek Model Number: GT-21089-1509-T3
RS485 ConnectorRS232 Connector
00
Figure 1: Back Panel MFR Evaluation Kit Black Box Reader
Figure 2: Software Development Kit (SDK)
User Guide Test Control Software
Page 3 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
Revision:
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3
Globtek Part Number: TR9CD1700CP-Y
00
2.2 Hardware Set Up
PC Com 1
Serial RS232
PC with
MFR Eva l
Kit
Test
Software
Power Supply
9V DC 1.0 Amp
Globtek PN: TR9CD1700CP-Y
Model Number: GT-21089-1509-
T3
Port
Connector, DB9M
No Connection
Connector
Circular
DIN
Figure 4: Hardware Set Up MFR Evaluation Kit
Communications
board Connector
J232
RS232
J485
RS485
J12
Power
RS232
RS485
+9 Volts
DC
Power
D = Distance form Tag to Reader
S4100 MFR Lite
HF/LF Antenna
Board
MFR Evaluation Kit
TAG
"D
"
User Guide Test Control Software
Page 4 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
3. Test Software
3.1 Initial Start Screen
1) After double clicking the MFR Demo software icon the software screen
below will appear.
2) Double click desired application folder tab to select application.
Revision:
00
Selects desired
‘Com’ port
Press to Open
“Com” Port
Figure 5: Initial Start Screen
3.2 Connection to RS232 Communications (Com) Port
1) Click on ‘Connec t’ button to open the COM port. You’ll see the
red indicator box with ‘COM Closed ’ text change color to GREEN
and read ‘COM Opened
2) If red indicator box stays red and reads ‘Com Closed’, the COM
port did not open successfull y.
3.2.1 Communications Port Choices
1) If the default Com Port of Com1 is not the desired Com Port, use Com
Port selection arrow to select desired Com Port; from the following
choices 1) Com1, 2) Com2, 3) Com3, 4) Com4.
’ for successful connection.
When Status Box
is Green ‘Com’
port is open
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Page 5 of 15 XX-XX-XX-XXX
TI PROPRIETARY T E X A S I N S T R U M E N T S
t
INFORMATION -
Revision:
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
2) Click on ‘Connec t’ button to open the COM port. You’ll see the
red indicator box with ‘COM Closed ’ text change color to GREEN
and read ‘COM Opened
’ for successful connection.
3) If red indicator box stays red and reads ‘Com Closed’, the COM
port did not open successfull y.
Use Com Port Selec
Arrow to select
desired Com Port
00
Figure 6: Com Port Choices supported
3.3 Turn On HF Transmitter
To Turn on the HF Transmitter:
1) Select 14443A Library folder Tab
2) Under 14443A Library folder Tab select Transmitter On
3) Click on ‘Execute’ button to issue a HF- Transmitter ON Command.
4) If successful, you would see the Green indicator with ‘TRANSMITTER
ON – 14443A’ text.
User Guide Test Control Software
Page 6 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
s
er
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
Revision:
00
Select Folder for
14443-A Library to
start HF transmitter
turn on procedure
When Status Box
is Green ‘Com’
port is open
Figure 7: Successful “Com” Port Connection
HF Transmitter
On Folder Tab
Press to turn on
HF (13.56 MHz)
Tran
mitt
Figure 8: Turn On HF Transmitter
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Page 7 of 15 XX-XX-XX-XXX
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
Revision:
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
00
Select Folder for
LF-DST Library to
start LF transmitter
turn on procedure
HF (13.56 MHz)
Transmitter On
Figure 9: Successful "Turn On " of HF Transmitter
3.4 Turn On LF Transmitter
To Turn on the LF Transmitter:
1) Select LF-DST Library folder Tab
2) Under LF-DST Library folder Tab select Transmitter On
3) Click on ‘Execute’ button to issue a LF- Transmitter ON Command.
4) If successful, you would see the Green indicator with ‘TRANSMITTER
ON – LF-DST’ text.
User Guide Test Control Software
Page 8 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
s
er
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
Revision:
00
Select Folder for
LF-DST Library to
start LF transmitter
turn on procedure
LF Transmitter
On Folder Tab
Press to turn on
LF (134 kHz)
Tran
mitt
Figure 10: Turn On LF Transmitter
LF (134 kHz)
Transmitter On
Figure 11: Successful “Turn On” of LF Transmitter
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Page 9 of 15 XX-XX-XX-XXX
TI PROPRIETARY T E X A S I N S T R U M E N T S
r
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
3.5 Turn Off HF Transmitter
To Turn Off the HF Transmitter:
1) Select 14443A Library folder Tab
2) Under 14443A Library folder Tab select Transmitter Off
3) Click on ‘Execute’ button to issue a HF- Transmitter Off Command.
4) If successful, you would see the Green indicator with ‘TRANSMITTER
OFF – 14443A’ text.
HF Transmitter
Off Folder Tab
Revision:
00
Select Folder for
14443-A Library
to start HF
transmitter turn
off procedure
Figure 12: Turn Off HF Transmitter
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Page 10 of 15 XX-XX-XX-XXX
Press to turn
off HF
(13.56 MHz)
Transmitte
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
3.6 Turn Off LF Transmitter
To Turn off the LF Transmitter:
1) Select LF-DST Library folder Tab
2) Under LF-DST Library folder Tab select Transmitter OFF
3) Click on ‘Execute’ button to issue a LF- Transmitter OFF Command.
4) If successful, you would see the Green indicator with ‘TRANSMITTER
OFF – LF-DST’ text.
Revision:
LF Transmitter
Off Folder Tab
00
Select Folder for
LF-DST Library to
start LF transmitter
turn off procedure
Figure 13: Turn Off LF Transmitter
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Page 11 of 15 XX-XX-XX-XXX
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
3.7 Close Com Port
1) Close the COM port by clicking on ‘Disconnect’ button.
You will see the Green Status Indicator with ‘COM Open’ text,
2)
change color to RED with a text change to ‘Com Closed to indicate
successful clo sure of the COM port .
Press “Disconnect”
Button to Close
‘Com Port’
Revision:
00
Figure 14: Com Port Closure
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Page 12 of 15 XX-XX-XX-XXX
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
Revision:
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
00
Figure 15: Successful Com Port Closure
3.8 Close Application
1) Click EXIT button to close the applicat ion.
4. Installation Guide S4110R MFR Evaluation Kits as shipped from factory
The Box unit and SDK unit configurations of the S4110 MFR Evaluation Kit
as shipped from the factory are compliant with FCC Part 15 Rules.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
FCC ID: A92S4110R Made in USA
Figure 16: FCC Label for S4110R MFR Evaluation Kit
User Guide Test Control Software
Page 13 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
4.1 Box Unit S4110 MFR Evaluation Kit as shipped from factory
4.1.1 Placement of FCC Label on Box Unit
Revision:
00
Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit
4.2 SDK Unit S4110 MFR Evaluation Kit as shipped from factory
4.2.1 Placement of FCC Label on Box Unit
Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Page 14 of 15 XX-XX-XX-XXX
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
Revision:
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for
help.
00
5. Revision History
Rev.
SCN Description of Change
0
New Issue
Date submitted By
04/20/2004
C.Bohren
User Guide Test Control Software
Page 15 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
Loading...