TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMAT ION - C. Bohren
INTERNAL DA T A R F I D SYSTEMS
S P E C I F I C A T I O N
Originator
Subco/Mfg Spec.
:
User Guide Test Control Software
S4110 MFR Evaluation Ki t
PRINTED COPIES OF THIS SPECIFICATION
ARE NOT CONTROLLED DOCUMENTS.
VERIFY THEIR CORRECT REVISION BEFORE USE.
Revision: 00
User Guide Test Control Software
S4110 MFR Evaluation Kit
Page 1 of 15 XX-XX-XX-XXX
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
Revision:
00
S P E C I F I C A T I O N
TABLE OF CONTENTS PAGE
1. Purpose............... ................ ................ .............................. ............................. ....3
2. Hardware Set up............ ............... .............................. ................ ......................3
2.1 S4110 MFR Evaluation Kit Hardware supplied.......... ......................... ........ 3
2.2 Hardware Set Up............... .. .... ... .... ... .... .. ..... .. ..... .. ..... .. .... ... .... ... .... .. ..... .. ....4
3. Test Software. .... ... .... .. ..... .. ..... .. .... ..... .. ..... .. ..... .. .... ... .... ... .... .. ..... .... ... .... ... .... .. ..5
3.1 Initial Start Screen ............................ ........................................... ...............5
3.2 Connection to RS232 Communications (Com) Port................. .. ... .. ..... .. .. .. ..5
3.2.1 Communications Port Choices.............................................................5
3.3 Turn On HF Transmitter.............. .. ..... .. ..... .. .... ... .... ... .... .. ..... .. ..... .. ..... .. .... ..6
3.4 Turn On LF Transmitter. .. . .. .. . .. .. . . .. . .. .. . . .. .. . .. .. . . ... . . .. .. . .. . . .. .. . .. .. . . ... . . .. .. . .. .. . . ..8
3.5 Turn Off HF Transmitter.. . .. . . ... . . .. . . ... . . .. . . ... . . .. . . ... . . .. . .. .. . . .. . .. .. . . .. . .. .. . . ... . . .. . .10
3.6 Turn Off LF Transmitter.............. ..... .. .... ... .... .. ..... .. ..... .. ..... .. .... ... .... ... .... ..11
3.7 Close Com Port........ .. .... ... .. .... ... .... ... .... .. ..... .. ..... .. ..... .. .... ... .... ... .... .. ..... .. ..12
3.8 Close Application .....................................................................................13
4. Installation Guide S4110R MFR Evaluation Kits as shipped from factory.13
4.1 Box Unit S4110 MFR Evaluation Kit as shipped from factory .. ................ 14
4.1.1 Placement of FCC Label on Box Unit ........................... ....................14
4.2 SDK Unit S4110 MFR Evaluation Kit as shipped from factory.................14
4.2.1 Placement of FCC Label on Box Unit ........................... ....................14
5. Revision History...................... .... .. ..... .. ..... .. .. ..... .. ..... .. ..... .. .... ... .... .. ..... .. ..... .. ..15
LIST O F FI G U R E S
Figure 1: Back Panel MFR Evaluation Kit Black Box Reader.............................. 3
Figure 2: Software Development Kit (SDK)............................... ................ ............ 3
Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3..... ............ 4
Figure 4: Hardware Set Up MFR Evaluation Kit .. .. ............................. ................ . 4
Figure 5: Initial Start Screen............... ................ .............................. ................ ..... 5
Figure 6: Com Port Choices supported.................. ................ ............... ................. 6
Figure 7: Successful “Com” Port Connection................................. ....................... 7
Figure 8: Turn On HF Transmitter........ ............................. ................ ................... 7
Figure 9: Successful "Turn On " of HF Transmitter .................. ................ .......... 8
Figure 10: Turn On LF Transmitter.......... .............................. ................ .............. 9
Figure 11: Successful “Turn On” of LF Transmitter ..... ................ ................ ....... 9
Figure 12: Turn Off HF Transmitter .............. ............................. .........................10
Figure 13: Turn Off LF Transmitter.. .............................. .............................. ......11
Figure 14: Com Port Closure............... .............................. .............................. ......12
Figure 15: Successful Com Port Closure............................................. ..................13
Figure 16: FCC Label for S4110R MFR Evaluation Kit......................................13
Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit...........14
Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit .........14
User Guide Test Control Software
Page 2 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
1. Purpose
The purpose of this document is to demonstrate the Test Control software for
the S4110 MFR Evaluation Kit..
2. Hardware Set up
2.1 S4110 MFR Evaluation Kit Hardware supplied
1) S4110 MFR Evaluation Kit Black Box Reader
2) S4110 MFR Evaluation Kit Software Development Kit (SDK) Reader
3) Power Supply, 9.0 Vdc 1.0 A, Globtek Part Number:
DC Power connector
+9 Vdc is center pin
Revision:
S P E C I F I C A T I O N
TR9CD1700LCP-Y
Globtek Model Number: GT-21089-1509-T3
RS485 Connector RS232 Connector
00
Figure 1: Back Panel MFR Evaluation Kit Black Box Reader
Figure 2: Software Development Kit (SDK)
User Guide Test Control Software
Page 3 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
Revision:
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3
Globtek Part Number: TR9CD1700CP-Y
00
2.2 Hardware Set Up
PC Com 1
Serial RS232
PC with
MFR Eva l
Kit
Test
Software
Power Supply
9V DC 1.0 Amp
Globtek PN: TR9CD1700CP-Y
Model Number: GT-21089-1509-
T3
Port
Connector, DB9M
No Connection
Connector
Circular
DIN
Figure 4: Hardware Set Up MFR Evaluation Kit
Communications
board Connector
J232
RS232
J485
RS485
J12
Power
RS232
RS485
+9 Volts
DC
Power
D = Distance form Tag to Reader
S4100 MFR Lite
HF/LF Antenna
Board
MFR Evaluation Kit
TAG
"D
"
User Guide Test Control Software
Page 4 of 15 XX-XX-XX-XXX
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.
TI PROPRIETARY T E X A S I N S T R U M E N T S
INFORMATION -
INTERNAL DATA R F I D SYSTEMS
S P E C I F I C A T I O N
3. Test Software
3.1 Initial Start Screen
1) After double clicking the MFR Demo software icon the software screen
below will appear.
2) Double click desired application folder tab to select application.
Revision:
00
Selects desired
‘Com’ port
Press to Open
“Com” Port
Figure 5: Initial Start Screen
3.2 Connection to RS232 Communications (Com) Port
1) Click on ‘Connec t’ button to open the COM port. You’ll see the
red indicator box with ‘COM Closed ’ text change color to GREEN
and read ‘COM Opened
2) If red indicator box stays red and reads ‘Com Closed’, the COM
port did not open successfull y.
3.2.1 Communications Port Choices
1) If the default Com Port of Com1 is not the desired Com Port, use Com
Port selection arrow to select desired Com Port; from the following
choices 1) Com1, 2) Com2, 3) Com3, 4) Com4.
’ for successful connection.
When Status Box
is Green ‘Com’
port is open
User Guide Test Control Software
S4110 MFR Evaluation Kit
Printed copies are not controlled documents - verify the correct revision before use.