RC4136, RM4136, RV4136
QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
D
Continuous-Short-Circuit Protection
D
Wide Common-Mode and Differential
Voltage Ranges
D
No Frequency Compensation Required
D
Low Power Consumption
D
No Latch-Up
D
Unity Gain Bandwidth...3 MHz Typ
D
Gain and Phase Match Between Amplifiers
D
Designed To Be Interchangeable With
Raytheon RC4136, RM4136, and RV4136
D
Low Noise...8 nV√Hz Typ at 1 kHz
description
The RC4136, RM4136, and RV4136 are quad
general-purpose operational amplifiers with each
amplifier electrically similar to the µA741 except
that offset null capability is not provided.
The high common-mode input voltage range and
the absence of latch-up make these amplifiers
ideal for voltage-follower applications. The
devices are short circuit protected and the internal
frequency compensation ensures stability without
external components.
The RC4136 is characterized for operation from
0°C to 70°C, the RM4136 is characterized for
operation over the full military temperature range
of –55°C to 125°C, and the RV4136 is
characterized for operation from –40°C to 85°C.
AVAILABLE OPTIONS
SMALL OUTLINE CHIP CARRIER CERAMIC DIP PLASTIC DIP FLAT
(D) (FK) (J) (N) (W)
0°C to 70°C 6 mV RC4136D — — RC4136N —
–40°C to 85°C 6 mV RV4136D — — RV4136N —
–55°C to 125°C 4 mV — RM4136FK RM4136J — RM4136W
The D packages are available taped and reeled. Add the suffix R to the device type (e.g., RC4136DR).
Copyright 1990, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
1
2
3
4
5
6
7
14
13
12
11
10
9
8
1IN–
1IN+
1OUT
2OUT
2IN+
2IN–
V
CC–
4IN–
4IN+
4OUT
V
CC+
3OUT
3IN+
3IN–
RM4136 ...J OR W PACKAGE
ALL OTHERS ...D OR N PACKAGE
(TOP VIEW)
3212019
910111213
4
5
6
7
8
18
17
16
15
14
4OUT
NC
V
CC+
NC
3OUT
1OUT
NC
2OUT
NC
2IN+
RM4136 .. . FK PACKAGE
(TOP VIEW)
NC
3IN –
3IN +
2IN –
NC
1IN +
1IN –
4IN –
4IN +
V
CC–
NC – No internal connection
symbol (each amplifier)
+
–
OUT
IN+
IN–
On products compliant to MIL-PRF-38535, all parameters are tested
unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
RC4136, RM4136, RV4136
QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
schematic (each amplifier)
OUT
IN+
IN–
V
CC–
V
CC+
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
RC4136 RM4136 RV4136 UNIT
Supply voltage V
CC+
(see Note 1) 18 22 18 V
Supply voltage V
CC–
(see Note 1) –18 –22 –18 V
Differential input voltage (see Note 2) ±30 ±30 ±30 V
Input voltage (any input, see Notes 1 and 3) ±15 ±15 ±15 V
Duration of output short circuit to ground, one amplifier at a time (see Note 4) unlimited unlimited unlimited
Continuous total dissipation See Dissipation Rating Table
Operating free-air temperature range 0 to 70 –55 to 125 –40 to 85 °C
Storage temperature range –65 to 150 –65 to 150 –65 to 150 °C
Case temperature for 60 seconds FK package — 260 — °C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds J or W package — 300 — °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or N package 260 — 260 °C
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC–
.
2. Differential voltages are at IN+ with respect to IN–.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
DISSIPATION RATING TABLE
PACKAGE
TA ≤ 25°C
POWER RATING
DERATING
FACTOR
DERATE
ABOVE T
A
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
TA = 125°C
POWER RATING
D 800 mW 7.6 mW/°C 45°C 608 mW 494 mW —
FK 800 mW 11.0 mW/°C77°C 800 mW 715 mW 275 mW
J 800 mW 11.0 mW/°C77°C 800 mW 715 mW 275 mW
N 800 mW 9.2 mW/°C63°C 736 mW 598 mW —
W 800 mW 8.0 mW/°C 50°C 640 mW 520 mW 200 mW