Texas Instruments RC4136D, RC4136DR, RC4136N, RC4136NS Datasheet

RC4136, RM4136, RV4136
QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
Continuous-Short-Circuit Protection
D
D
No Frequency Compensation Required
D
Low Power Consumption
D
No Latch-Up
D
Unity Gain Bandwidth...3 MHz Typ
D
Gain and Phase Match Between Amplifiers
D
Designed To Be Interchangeable With Raytheon RC4136, RM4136, and RV4136
D
Low Noise...8 nV√Hz Typ at 1 kHz
description
The RC4136, RM4136, and RV4136 are quad general-purpose operational amplifiers with each amplifier electrically similar to the µA741 except that offset null capability is not provided.
The high common-mode input voltage range and the absence of latch-up make these amplifiers ideal for voltage-follower applications. The devices are short circuit protected and the internal frequency compensation ensures stability without external components.
The RC4136 is characterized for operation from 0°C to 70°C, the RM4136 is characterized for operation over the full military temperature range of –55°C to 125°C, and the RV4136 is characterized for operation from –40°C to 85°C.
AVAILABLE OPTIONS
PACKAGE
T
A
V
IO
max
°
SMALL OUTLINE CHIP CARRIER CERAMIC DIP PLASTIC DIP FLAT
AT 25 C
(D) (FK) (J) (N) (W)
0°C to 70°C 6 mV RC4136D RC4136N
–40°C to 85°C 6 mV RV4136D RV4136N
–55°C to 125°C 4 mV RM4136FK RM4136J RM4136W
The D packages are available taped and reeled. Add the suffix R to the device type (e.g., RC4136DR).
Copyright 1990, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
1 2 3 4 5 6 7
14 13 12 11 10
9 8
1IN–
1IN+ 1OUT 2OUT
2IN+
2IN–
V
CC–
4IN– 4IN+ 4OUT V
CC+
3OUT 3IN+ 3IN–
RM4136 ...J OR W PACKAGE
ALL OTHERS ...D OR N PACKAGE
(TOP VIEW)
3212019
910111213
4 5 6 7 8
18 17 16 15 14
4OUT NC V
CC+
NC 3OUT
1OUT
NC
2OUT
NC
2IN+
RM4136 .. . FK PACKAGE
(TOP VIEW)
NC
3IN –
3IN +
2IN –
NC
1IN +
1IN –
4IN –
4IN +
V
CC–
NC – No internal connection
symbol (each amplifier)
+
OUT
IN+
IN–
On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.
RC4136, RM4136, RV4136 QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
schematic (each amplifier)
OUT
IN+
IN–
V
CC–
V
CC+
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
RC4136 RM4136 RV4136 UNIT
Supply voltage V
CC+
(see Note 1) 18 22 18 V
Supply voltage V
CC–
(see Note 1) –18 –22 –18 V Differential input voltage (see Note 2) ±30 ±30 ±30 V Input voltage (any input, see Notes 1 and 3) ±15 ±15 ±15 V Duration of output short circuit to ground, one amplifier at a time (see Note 4) unlimited unlimited unlimited Continuous total dissipation See Dissipation Rating Table Operating free-air temperature range 0 to 70 –55 to 125 –40 to 85 °C Storage temperature range –65 to 150 –65 to 150 –65 to 150 °C Case temperature for 60 seconds FK package 260 °C Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds J or W package 300 °C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or N package 260 260 °C
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC–
.
2. Differential voltages are at IN+ with respect to IN–.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
DISSIPATION RATING TABLE
PACKAGE
TA 25°C
POWER RATING
DERATING
FACTOR
DERATE
ABOVE T
A
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
TA = 125°C
POWER RATING
D 800 mW 7.6 mW/°C 45°C 608 mW 494 mW
FK 800 mW 11.0 mW/°C77°C 800 mW 715 mW 275 mW
J 800 mW 11.0 mW/°C77°C 800 mW 715 mW 275 mW
N 800 mW 9.2 mW/°C63°C 736 mW 598 mW
W 800 mW 8.0 mW/°C 50°C 640 mW 520 mW 200 mW