Texas Instruments BQ2018TS-E1TR, BQ2018TS-E1, BQ2018SN-E1TR, BQ2018SN-E1 Datasheet

1
Features
Multifunction charge/discharge counter
Resolves signals less than 12.5µV
Internal offset calibration im
-
1024 bits of NVRAM configured as 128x8
Internal temperature sensor for self-discharge estimation
Single-wire serial interface
Dual operating modes:
-
Operating: <80µA
- Sleep: <10µA
REG output for low-cost mi-
croregulation
Internal timebase eliminates ex-
ternal components
8-pin TSSOP or SOIC allows bat-
tery pack integration
General Description
The bq2018 is a low-cost charge/dis
­charge counter peripheral packaged in an 8-pin TSSOP or SOIC. It works with an intelligent host controller, pro
­viding state-of-charge information for rechargeable batteries.
The bq2018 measures the voltage drop across a low-value series sense resistor between the negative termi
­nal of the battery and the battery pack ground contact. By using the ac
­cumulated counts in the charge, discharge, and self-discharge regis­ters, an intelligent host controller can determine battery state-of-charge in­formation. To improve accuracy, an offset count register is available. The system host controller is responsible for the register maintenance by reset­ting the charge in/out and self­discharge registers as needed.
The bq2018 also features 128 bytes of NVRAM registers. The upper 13 bytes of NVRAM contain the capac
-
ity monitoring and status informa
­tion. The RBI input operates from an external power storage source such as a capacitor or a series cell in the battery pack, providing register nonvolatility for periods when the battery is shorted to ground or when the battery charge state is not suffi
­cient to operate the bq2018. During this mode, the register backup cur
­rent is less than 100nA.
Packaged in an 8-pin TSSOP or SOIC, the bq2018 is small enough to fit in the crevice between two A­size cells or within the width of a prismatic cell.
REG Regulator output
V
CC
Supply voltage input
V
SS
Ground
HDQ Data input/output
1
PN-201801.eps
8-Pin TSSOP or Narrow SOIC
2
3
4
8
7
6
5
REG
V
CC
V
SS
HDQ
WAKE
SR1
SR2 RBI
WAKE Wake-up output
SR1 Current sense input 1
SR2 Current sense input 2
RBI Register backup input
Pin Connections Pin Names
bq2018
Power Minder™ IC
SLUS003–JUNE 1999 C
Pin Descriptions
REG
Regulator output
REG is the output of the operational trans
­conductance amplifier (OTA) that drives an external pass n-channel JFET to provide an optional regulated supply. The supply is regulated at 3.7V nominal.
V
CC
Supply voltage input
When regulated by the REG output, VCCis
3.7V ±200mV. When the REG output is not used, the valid operating range is 2.8V to
5.5V.
V
SS
Ground
SR1– SR2
Current sense inputs
The bq2018 interprets charge and discharge activity by monitoring and integrating the voltage drop (V
SR
) across pins SR1 and SR2. The SR1 input connects to the sense resistor and the negative terminal of the battery. The SR2 input connects to the sense resistor and the negative terminal of the pack. V
SR1
<V
SR2
indicates discharge, and V
SR1>VSR2
indicates charge. The effective voltage drop, V
SRO
, as seen by the bq2018, is VSR+VOS.
Valid input range is±200mV.
HDQ
Data input/output
This bi-directional input/output communi­cates the register information to the host system. HDQ is open drain and requires a pullup/down resistor in the battery pack to disable/enable sleep mode if the pack is re
-
moved from the system.
RBI
Register backup input
This input maintains the internal register states during periods when V
CC
is below the
minimum operating voltage.
WAKE
Wake-up output
When asserted, this output is used to indi
­cate that the charge or discharge activity is above a programmed minimal level.
Functional Description
General Operation
A host can use the bq2018 internal counters and timers to measure battery state-of-charge, estimate self­discharge, and calculate the average charge and dis
­charge current into and out of a rechargeable battery. The bq2018 needs an external host system to perform all register maintenance. Using information from the bq2018, the system host can determine the battery state-of-charge, estimate self-discharge, and calculate the average charge and discharge currents. During pack storage periods, the use of an internal temperature sen
­sor doubles the self-discharge count rate every 10° above 25°C.
To reduce cost, power to the bq2018 may be derived using a low-cost external FET in conjunction with the REG pin. The bq2018 operating current is less than 80µA. When the HDQ line remains low for greater than ten seconds and V
SRO(VSR+VOS
where VSRis the voltage drop be­tween SR1 and SR2 and VOSis the offset voltage) is below the programmed minimal level (WAKE is in High Z), the bq2018 enters a sleep mode of <10µA where all opera­tions are suspended. HDQ transitioning high reinitiates the bq2018.
A register is available to store the calculated offset, allow­ing current calibration. The offset cancellation register is written by the bq2018 during pack assembly and is avail­able to the host system to adjust the current measure­ments. By adding or subtracting the offset value stored in the OFR, the true charge and discharge counts can be calculated to a high degree of certainty.
Figure 1 shows a block diagram of the bq2018, and Table 1 outlines the bq2018 operational states.
REG Output
The bq2018 can operate directly from three or four nickel-chemistry cells or a single Li-Ion cell as long as VCCis limited to 2.8 to 5.5V. To facilitate the power sup
­ply requirements of the bq2018, a REG output is present to regulate an external low-threshold n-JFET. A micro
­power VCCsource for the bq2018 can inexpensively be built using this FET.
2
bq2018
Note: V
SRO
is the voltage difference between SR1 and SR2 plus the offset voltage VOS.
3
BD201801.eps
Differential
Dynamically
Balanced VFC
System
I/O
and
Control
RAM
and
Counters
128 x 8
Counter
Control
Temperature-
Compensated
Precision Oscillator
Bandgap
Voltage
Reference
Temperature
Sensor
SR1 SR2
HDQ
RBI
VDD (Internal)
Optional
(External)
ds
g
REG
V
CC
V
SS
Timer
Calibration and Power
Control
WAKE
V
ref
Figure 1. bq2018 Block Diagram
bq2018
HDQ Pin DCR/CCR/SCR WOE WAKE Operating State
HDQ High yes |V
SRO
| > V
WOE
Low Normal
HDQ High yes |V
SRO
| < V
WOE
High Z Normal
HDQ Low no |V
SRO
| < V
WOE
High Z Sleep
Table 1. Operational States
4
RBI Input
The RBI input pin is used with a storage capacitor or ex­ternal supply to provide back-up potential to the internal RAM when VCCdrops below 2.4V. The maximum dis­charge current is 100nA in this mode. The bq2018 out­puts VCCon RBI when the supply is above 2.4V, so a di­ode is required to isolate an external supply.
Charge/Discharge Count Operation
Table 2 shows the main counters and registers of the bq2018. The bq2018 accumulates charge and discharge counts into two main count registers, the Discharge Count Register (DCR) and the Charge Count Register (CCR). The bq2018 produces charge and discharge
counts by sensing the voltage difference across a low­value resistor between the negative terminal of the bat­tery pack and the negative terminal of the battery. The DCR or CCR counts depending on the signal between SR1 and SR2.
During discharge, the DCR and the Discharge Time Counter (DTC) are active. If V
SR1
is less than V
SR2
, indi-
cating a discharge, the DCR counts at a rate equivalent to
12.5µV every hour, and the DTC counts at a rate of 1 count/0.8789 seconds (4096 counts per 1 hour). For exam
-
ple, a -100mV signal produces 8000 DCR counts and 4096 DTC counts each hour. The amount of charge removed from the battery can easily be calculated.
bq2018
Table 2. bq2018 Counters
Name Description Range RAM Size
DCR Discharge count register
V
SR1
< V
SR2
(Max. =-200mV) 12.5µVh increments
16-bit
CCR Charge count register
V
SR1>VSR2
(Max. = +200mV) 12.5µVh increments
16-bit
SCR Self-discharge count register 1 count/hour @ 25°C 16-bit
DTC Discharge time counter
1 count/0.8789s default
1 count/225s if STD is set
16-bit
CTC Charge time counter
1 count/0.8789s default
1 count/225s if STC is set
16-bit
MODE/ WOE
MODE/ Wake output enable
8-bit
RBI
SR2
SR1
WAKE
HDQ
VSS
VCC
REG
BQ2018
U1
1 2 3 45
6
7
8
C1
VCC
SST113
Q1
BAT+
BZX84C5V6
D1
2
HDQ
BZX84C5V6
D2
2
100
R5
C4
C2
C3
BAV99
D3
1M
d
s
R4
RBI
PACK-
BAT-
1W
0.05
R1
100K
R3
100K
R2
WAKE
1K
R6
VCC
0.01µF
0.1µF
0.1µF
0.1µF
0.1µF
C5
2018typAp.eps
Figure 2. Typical Application
5
During charge, the CCR and the Charge Time Counter (CTC) are active. If V
SR1
is greater than V
SR2
, indicating a charge, the CCR counts at a rate equivalent to 12.5µV every hour, and the CTC counts at a rate of 1 count/0.8789 seconds. For example, a +100mV signal pro­duces 8000 CCR counts and 4096 CTC counts each hour. The amount of charge added to the battery can easily be calculated.
The DTC and the CTC are 16-bit registers, and roll over beyond ffffh. If a rollover occurs, the corresponding bit in the MODE/WOE register is set, and the counter will sub­sequently increment at 1/256 of the normal rate (16 counts/hr.).
Whenever the signal between SR1 and SR2 is above the Wakeup Output Enable (WOE) threshold and the HDQ pin is high, the bq2018 is in its full operating state. In this state, the DCR, CCR, DTC, CTC, and SCR are fully operational, and the WAKE output is low. During this mode, the internal RAM registers of the bq2018 may be accessed over the HDQ pin, as described in the section “Communicating With the 2018.”
If the signal between SR1 and SR2 is below the WOE threshold (refer to the WAKE section for details) and HDQ remains low for greater than 10 seconds, the bq2018 enters a sleep mode where all register counting is suspended. The bq2018 remains in this mode until HDQ returns high.
For self-discharge calculation, the self-discharge count register (SCR) counts at a rate equivalent to 1 count every hour at a nominal 25°C and doubles approximately every 10°C up to 60°C. The SCR count rate is halved every 10 °C below 25°C down to 0°C. The value in SCR is
useful in determining an estimation of the battery self­discharge based on capacity and storage temperature conditions.
The bq2018 may be programmed to measure the voltage offset between SR1 and SR2 during pack assembly or at any time by invoking the Calibration mode. The Offset Register (OFR) is used to store the bq2018 offset. The 8­bit 2’s complement value stored in the OFR is scaled to the same units as the DCR and CCR, representing the amount of positive or negative offset in the bq2018. The maximum offset for the bq2018 is specified as±500µV. Care should be taken to ensure proper PCB layout. Us­ing OFR, the system host can cancel most of the effects of bq2018 offset for greater resolution and accuracy.
Figure 3 shows the bq2018 register address map. The bq2018 uses the upper 13 locations. The remaining memory can store user-specific information such as chemistry, serial number, and manufacturing date.
WAKEOutput
This output is used to inform the system that the voltage difference between SR1 and SR2 is above or below the Wake Output Enable (WOE) threshold programmed in the MODE/WOE register. When the voltage difference between SR1 and SR2 is below V
WOE
, the WAKE output
goes into High Z and remains in this state until the dis
­charge or charge current increases above the specified value. The MODE/WOE resets to 0eh after a power-on reset. V
WOE
is set by dividing 3.84mV by a value be
­tween 1 and 7 (1–7h) according to Table 3.
bq2018
7f 7e 7d 7c 7b 7a 79 78 77 76 75 74 73
User RAM
Discharge count high byte Discharge count low byte Charge count high byte Charge count low byte Self-discharge high byte Self-discharge low byte Discharge time high byte Discharge time low byte Charge time high byte Charge time low byte Mode/wake output enable Temperature/clear Offset register
FG201801.eps
00
73 72
7f
Figure 3. Address Map
T ab le 3. WOE Thresholds
WOE
3–1
(hex) V
WOE
(mV)
0h n/a
1h 3.840
2h 1.920
3h 1.280
4h 0.960
5h 0.768
6h 0.640
7h* 0.549
* Default value after POR.
Temperature
The bq2018 has an internal temperature sensor which is used to set the value in the temperature register (TMP/CLR) and set the self-discharge count rate value. The register reports the temperature in 8 steps of 10°C from <0°C to >60°C as Table 4 specifies. The bq2018 tem­perature sensor has typical accuracy of
±
2°Cat 25°C.
See the TMP/CLR register description for more details.
Clear Register
The host system is responsible for register maintenance. To facilitate this maintenance, the bq2018 has a Clear Register (TMP/CLR) designed to reset the specific coun­ter or register pair to zero. The host system clears a reg­ister by writing the corresponding register bit to 1. When the bq2018 completes the reset, the corresponding bit in the TMP/CLR register is automatically reset to 0, which saves the host an extra write/read cycle. Clearing the DTC register clears the STD bit and sets the DTC count rate to the default value of 1 count per 0.8789s. Clearing
the CTC register clears the STC bit and sets the CTC count rate to the default value of 1 count per 0.8789s.
Calibration Mode
The system can enable bq2018 VOScalibration by setting the calibration bit in the MODE/WOE register (Bit 6) to
1. The bq2018 then enters calibration mode when the HDQ line is low for greater than 10 seconds and when the signal between SR1 and SR2 is below V
WOE
. Cau-
tion: Take care to ensure that no low-level exter­nal signal is present between SR1 and SR2 because this affects the calibration value that the bq2018 calculates.
If HDQ remains low for one hour and |V
SR
|<V
WOE
for the entire time, the measured VOSis latched into the OFR register, and the calibration bit is reset to zero, indi
-
cating to the system that the calibration cycle is com
-
plete. Once calibration is complete, the bq2018 enters a
6
bq2018
TD201801.eps
Break
Written by Host to bq2018
LSB
0 1 2 3 4 5 6 7
MSB
110
01110
CMDR = 73h
73h = 0 1 1 1 0 0 1 1
MSB
LSB
Received by Host from bq2018
LSB
0
1 2 3 4 5 6
7
Data (OFR) = 65h
MSB
1
010011
0
65h = 0 1 1 0 0 1 0 1
MSB LSB
Figure 4. Typical Communication with the bq2018
Temp Value (hex) SDR Count Rate
<0° 0h
×
1/8
0–10° 1h
×
1/4
10–20° 2h
×
1/2
20–30° 3h 1 count/hr.
30–40° 4h
×
2
40–50° 5h
×
4
50–60° 6h
×
8
>60° 7h
×
16
Table 4. Temperature Steps
7
Symbol
Register
Name
Loc.
(hex)
Read/
Write
Control Field
7(MSB) 6543210(LSB)
CMDR
Command register
- Write W/R
AD6 AD5 AD4 AD3 AD2 AD1 AD0
DCRH
Discharge count register high byte
7f Read DCRH7 DCRH6 DCRH5 DCRH4 DCRH3 DCRH2 DCRH1 DCRH0
DCRL
Discharge count register low byte
7e Read DCRL7 DCRL6 DCRL5 DCRL4 DCRL3 DCRL2 DCRL1 DCRL0
CCRH
Charge count register high byte
7d Read CCRH7 CCRH6 CCRH5 CCRH4 CCRH3 CCRH2 CCRH1 CCRH0
CCRL
Charge count register low byte
7c Read CCRL7 CCRL6 CCRL5 CCRL4 CCRL3 CCRL2 CCRL1 CCRL0
SCRH
Self-discharge count register high byte
7b Read SCRH7 SCRH6 SCRH5 SCRH4 SCRH3 SCRH2 SCRH1 SCRH0
SCRL
Self-discharge count register low byte
7a Read SCRL7 SCRL6 SCRL5 SCRL4 SCRL3 SCRL2 SCRL1 SCRL0
DTCH
Discharge time count high byte
79 Read DTCH7 DTCH6 DTCH5 DTCH4 DTCH3 DTCH2 DTCH1 DTCH0
DTCL
Discharge time count low byte
78 Read DTCL7 DTCL6 DTCL5 DTCL4 DTCL3 DTCL2 DTCL1 DTCL0
CTCH
Charge time count high byte
77 Read CTCH7 CTCH6 CTCH5 CTCH4 CTCH3 CTCH2 CTCH1 CTCH0
CTCL
Charge time count low byte
76 Read CTCL7 CTCL6 CTCL5 CTCL4 CTCL3 CTCL2 CTCL1 CTCL0
MODE/ WOE
MODE/ wake­up output enable
75
Read/ write
OVRDQ CAL STC STD WOE3 WOE2 WOE1 0
TMP/CLR
Tempera
­ture/Clear register
74
Read/ write
TMP2 TMP1 TMP0 CTC DTC SCR CCR DCR
OFR
Offset register
73
Read/ write
OFR7 OFR6 OFR5 OFR4 OFR3 OFR2 OFR1 OFR0
RAM
User memory
72-00
Read/ write
--------
Notes: 1. MODE/WOE register bit 0 is set to zero at startup and should not be
written to 1 for proper bq2018 operation.
2. OFR value is in two’s complement.
Table 5. bq2018 Command and Status Registers
bq2018
Loading...
+ 14 hidden pages