Outputs LED
1–2
have three display modes that are
selected at initialization by the input pins DSEL
1
and
DSEL
2
. The DSEL1and DSEL2input pins, when pulled
down to V
SS
, are intended for implementation of a
simple two-LED system. LED
2
indicates the precharge
status (i.e., charge pending and discharge) and LED
1
indi
cates the charge status (i.e., charging and completion).
DSEL
1
pulled up to VCCand DSEL2pulled down to V
SS
mode is for implementation of a single tri-color LED such
that discharge, charging, and completion each have a unique
color. DSEL
1
pulled down to VSSand DSEL2pulled up to
V
CC
allows for fault status information to be displayed.
Audio Output Alarm
The bq2007 audio alarm output generates an audio tone
to indicate a charge completion or fault condition. The
audio alarm output is a symmetrical duty-cycle AC sig
nal that is compatible with standard piezoelectric alarm
elements. A valid battery insertion is indicated by a sin
gle high-tone beep of
1
2
-second typical duration. The
charge completion and fault conditions are indicated by
a 9.5- to 15-second high-tone sequence of
1
2
-second typi-
cal duration at a 2-second typical repetition rate.
Charge Status Monitoring
The bq2007 charge status monitor may display the bat
tery voltage or charge safety timer as a percentage of
the full-charged condition. These options are selected
with the MULT soft-programmed input pin.
When MULT is pulled down to V
SS
, the battery charge
status is displayed as a percentage of the battery
voltage, and the single-cell battery voltage at the BAT
pin is compared with internal charge voltage reference
thresholds. When V
BAT
is greater than the internal
thresholds of V
20,V40,V60
,orV80, the respective 20%,
40%, 60%, or 80% display outputs are activated. The
battery voltage directly indicates 20% charge
increments, while the 10% charge increments use a
timer that is a function of the charge safety timer.
When MULT is pulled down to V
SS
and when V
BAT
exceeds V20during charging, the 20% charge indication
is activated and the timer begins counting for a period
equal to
1
64
to
1
32
of the charge safety time-out period.
When the timer count is completed, the 30% charge
indication is activated. Should V
BAT
exceed V40prior to
the timer count completion, the charge status monitor
activates the 30% and 40% indications. This technique
5
bq2007
Charge Action
State Conditions MOD Output DIS Output
Battery absent V
CC
applied and V
CELL
≥
V
MCV
Trickle charge per Table 4 Low
Charge initiation
V
CC
applied or V
CELL
drops
from≥V
MCV
to < V
MCV
- Low
Discharge-beforecharge
DCMD
high-to-low transition or to VSSon charge
initiation and V
EDV
< V
CELL
< V
MCV
Low High
Charge pending
Charge initiation occurred and V
TEMP
≥
V
LTF
or
V
TEMP
≤
V
TCO
or V
CELL
< V
EDV
Trickle charge per Table 4 Low
Fast charging
Charge pending complete and FAST = V
CC
Low if V
SNS
> 250mV;
high if V
SNS
< 200mV
Low
Standard charging
Charge pending complete and FAST = V
SS
Low if V
SNS
> 250mV;
high if V
SNS
< 200mV
Low
Charge complete
-∆V termination or V
TEMP
< V
TCO
or PVD≥0 to
-3mV/cell or maximum time-out or V
CELL
> V
MCV
--
Top-off pending
VSEL = V
CC
, charge complete and V
TEMP
≥
V
LTF
or V
TEMP
≤
V
TCO
or V
CELL
< V
EDV
Trickle charge per Table 4 Low
Top-off charging
VSEL = V
CC
and charge complete and
time-out not exceeded and V
TEMP
> V
TCO
and
V
CELL
< V
MCV
Activated per V
SNS
for
73ms of every 585ms Low
Trickle charging
Charge complete and top-off disabled or
top-off complete or pending
Trickle charge per Table 4 Low
Fault
Charge pending state and charge pending
time-out (t
PEND
) complete
Trickle charge per Table 4 Low
Definitions: V
CELL
= V
BAT
- V
SNS;VMCV
= 0.8*VCC;V
EDV
= 0.262*VCCor 0.4*VCC;V
TEMP
= VTS- V
SNS
;
V
LTF
= 0.5*VCC.
Table 1. bq2007 Operational Summary