TEXAS INSTRUMENTS 20413, 20600, 20650 Technical data

I NDUSTRIAL SENSORS &CONTROLS
20413, 20600, 20650 SERIES
Snap-Action Automatic and Manual reset
Fixed Temperature Thermostats
Key Features
• Klixon snap-action bimetal disc assures positive make/break action.
• Temperature setting factory calibrated to your specifications
• High capacity – up to 30 amps at 120, 240, and 277 VAC resistive.
• Extra high capacity – up to 40 amps at 120 and 240 VAC resistive
Automatic reset Standard Constructions
Manual Reset Standard Constructions
Single-Pole, Double-Throw
20600D
Small Oval Top Flange
Double-Pole, Single-Throw
20650
Small Oval Top Flange
Single-Pole, Single-Throw
20601 / 04 / 06 F or L
Small Oval Top Flange
Single-Pole, Single-Throw
20603 / 05 F or L
Small Oval Top Flange
Manual Override
20611 / 12 / 16L
Special Oval Bottom Flange
Manual Override
20650
Integral Surface Flange
Trip Free
20413
Small Oval Top Flange
Trip Free
20615 / 19L
Small Oval Top Flange
查询20413供应商
Description
Klixon® thermostats have been in production for over 50 years. The 20413, 20600, and 20650 series thermostats are especially designed ed for applications where space, capacity and ease of assembly are important production factors. They are fixed-setting, snap-acting, auto­matic or manual reset temperature controls that are ideal for such applications as: air conditioners, heating and ventilating equipment, vending machines, dryers, unit heaters, tabletop appliances, etc.
All automatic series are available as limit switches (open on tempera­ture rise) or fdan switches (close on temperature rise). Switch action is SPST, SPDT, or DPST with auto­matice reset types. Manual reset is available as a limit switch in SPST construction only.
The switch mechanism is actuated by the Klixon snap-action, bimetal disc which may be enclosed or exposed. Enclosed disc devices are particularly recommended for appli­cations in which dust and lint are prevalent in the environment. Exposed disc types are used in applications where a faster thermal response to radiant heat is needed. Contact parts are enclosed for both disc types for protection against contamination.
Mountings and Terminals
A variety of terminals and mounting flanges are available to meet instal­lation requirements of most applications.
Flanges can be used for surface or thru-wall mountings; or, thermostats can be supplied without flanges for well or cavity-type mountings. Flange rotations are specified by looking down on the terminals and rotating the flange 30o, 45o, or 90oCW or CCW.
Flanges Available
• Small oval bottom flange
• Integral surface flange
• No flange cup
• 3/4” deep cup
• Special oval bottom flange Electrical connections to the ther-
mostat must be tight; otherwise, resistance in a loose connection may cause sufficient temperature rise to affect the performance of the ther­mostat or damage the terminals or the lead wire insulation.
Terminals Available
Quick connects are available in siver flash or plain brass.
• 1/4”Quick connects 0o, 30o, 45o, 90oterminals are male spade type .250” x .032” thick.
• Strap terminals for electric heat­ing
• Brass screw terminals 0o, 45
o
When screw terminals are specified, washer head screws are supplied unassembled. Assembled washer head screws are available at extra cost. Standard screw terminals have 8-32 NC-2 threads.
Temperaturre Settings, Tolerances and Nominal Differentials
Standard Tolerances
The ranges of temperature settings, tolerances, and nominal differen­tials shown below are available. Differential is the difference between opening and closing tem­perature in oF. For example, a thermostat which opens at 180oF and closes at 140oF has a 40
o
differential. (Lowest unit prices are achieved by selecting differentials in the 30oF to 59oF range). For temperature settings and differen­tials other than those shown, please consult Marketing.
Manual Reset Construction
There are two basic manual reset constructions:
1) Manual Override – contracts can be closed at any time after device has actuated by depress­ing reset button.
2) Trip-Free – contacts will remain open after device has actuated until bimetal disc resets, even if reset button is depressed.
Agency Recognition
Klixon 206 Series Thermostats are recognized by UL and CSA. Please consult Marketing for international approvals.
UL Electrical Group
File No. E9977 U.S. Guide No. XAPX2 Canada Guide NO. XAPX8 HC&R Group File NO. MP986 U.S. Guide No. MBPR2 Canada Guide No. MBRR8
For further information write or call: Texas Instruments Incorporated
Commercial Sensors & Controls Thermal Controls Marketing
34 Forest Street, MS 23-10 Attleboro, MA 02703-0964 Phone: (508) 236-3192
(508) 236-1894 Fax; (508) 236-2349 or visit our website @: www.tisensors.com
Highest
Temperature
Setting
o
F
Nominal
Differential
o
F
Standard
Tolerances
Open Close
o
F
10 to 14* 15 to 29 30 to 59 60 to 150
10 to 29* 30 to 39 40 to 59 60 to 150
20 to 29 30 to 39 40 to 59 60 to 150
30 to 39 40 to 59 60 to 150
30 to 39 40 to 59 60 to 150
-10 to 80
81 to 200
201 to 250
251 to 300
301 to 350
**
±5 ±6 ±6 ±7
±5 ±5 ±5 ±6
±5 ±5 ±6 ±7
±6 ±7 ±8
±7 ±8 ±9
±5 ±6 ±7 ±8
±5 ±6 ±7 ±8
±6 ±7 ±8 ±9
±8 ±10 ±11
±10 ±12 ±13
• Available in SPST construction only. SPDT thermostats must have 15ominimum differentials.
**20413 series – up to 300
o
20600 series – up to 350
o
20650 / 54 series – up to 300o; minimum differential 30o.
Ambient Temperature
-40oF to +350oF
-40oC to +177oC
Loading...