4.4 Carrying out a firmware update ........................................................... 44
5 Technical data ................................................................................... 45
6 Tips and assistance ........................................................................... 47
6.1 Questions and answers ....................................................................... 47
6.1.1 LED status Bluetooth® probe ................................................ 47
6.1.2 Hot wire measurement not possible ..................................... 47
6.2 Accessories and spare parts ............................................................... 47
7 Authorisations and certification .......................................................... 49
1 Safety and disposal
1 Safety and disposal
1.1 About this document
The instruction manual is an integral part of the instrument.
Pay particular attention to the safety instructions and warning advice in
order to prevent injury and damage to the product.
Keep this documentation on hand so that you can refer to it when
necessary.
Hand this instruction manual on to any subsequent users of the product.
1.2 Security
General safety instructions
Only operate the product properly, for its intended purpose, and within the
parameters specified in the technical data.
Do not apply any force.
Do not operate the instrument if there are signs of damage on the housing,
power supply or connected cables.
Dangers may also arise from objects to be measured or the measuring
environment. Always comply with the locally valid safety regulations when
carrying out measurements.
Do not store the product together with solvents.
Do not use any desiccants.
Only perform maintenance and repair work on this instrument that is
described in this documentation. Follow the prescribed steps exactly when
doing the work.
Use only original spare parts from Testo.
Maintenance work that is not described in this documentation must only be
carried out by trained service engineers.
Temperature information given on probes/sensors relates only to the
measuring range of the sensor technology. Do not expose handles and feed
lines to temperatures in excess of 70 °C (158 °F), unless they are expressly
authorized for use at higher temperatures.
3
1 Safety and disposal
Do not carry out any contact measurements on uninsulated, live parts.
Transport and store the instrument only in the associated packaging, in
order to prevent any damage to the sensor.
Batteries
Improper use of batteries may cause the batteries to be destroyed, or lead
to injury due to current surges, fire or escaping chemicals.
Only use the batteries supplied in accordance with the instructions in the
instruction manual.
Do not short-circuit the batteries.
Do not take the batteries apart and do not modify them.
Do not expose the batteries to heavy impacts, water, fire or temperatures in
excess of 60 °C.
Do not store the batteries in the proximity of metal objects.
Do not use any leaky or damaged batteries.
Take the rechargeable battery out of the instrument immediately if it is not
functioning properly or if it shows signs of superheating. Rechargeable
battery may be hot!
In the event of contact with battery acid: rinse affected areas thoroughly
with water, and if necessary consult a doctor.
When not in use for a long period of time, take the rechargeable battery out
of the instrument to prevent exhaustive discharge.
1.3 Warning notices
Always pay attention to any information marked with the following warning
notices along with warning pictograms. Implement the specified precautionary
measures!
DANGER
Risk of death!
WARNING
Indicates possible serious injury.
CAUTION
Indicates possible minor injury.
4
1 Safety and disposal
CAUTION
Indicates possible damage to equipment.
1.4 Disposal
Dispose of faulty rechargeable batteries and spent batteries in accordance
with the valid legal specifications.
At the end of its useful life, deliver the product to the separate collection
point for electric and electronic devices (observe local regulations) or return
the product to Testo for disposal.
5
2 Description of the instrument
2 Description of the instrument
2.1 Use
The testo 440 is used for measuring climate-related parameters. The testo 440
is particularly suitable for comfort level measurements for remove the
workplace evaluation and disturbance measurements in and at air conditioning
systems.
The instrument is only to be used by qualified personnel and must not be used
in potentially explosive atmospheres!
The testo 440 is supplied with inserted batteries. The batteries are
secured by a battery safety strip.
1 Open the battery compartment cover.
2 Remove the battery safety strip.
3 Close the battery compartment cover.
The testo 440 is ready for use.
12
3.2 Switching the testo 440 on/off
Initial activation
For initial commissioning or after a factory reset, the Initial Operation
menu is opened automatically. In normal mode, the last menu used is
displayed after switching it on.
3 Operation
1
Press .
The Initial Operation menu is displayed.
2 Make the following settings in sequence:
- Language [Language]
Date (year/month/day) and time (format, time) [Date/Time]
- Unit system (ISO/US) [Units]
The basic settings have been set. They can be adjusted any time in
Settings.
Switching on
1
Press .
The last active menu when the instrument was switched off is
displayed.
Switching off
13
3 Operation
1
Press and hold for at least 3 seconds.
The testo 440 switches itself off.
3.3 Making basic settings
Use the menu key to go to the testo 440 Settings menu. The following settings
are available in this menu:
Menu item Function/Settings
Basic View Show current measuring values
Select Application Select required application for the
measurement
Memory Show and manage saved measurements
Settings Making basic settings:
- Bluetooth
- Power Management Ambient Conditions
- Units
- Date/time
- Languages
- General (instrument and probe status,
3.3.1 Establishing a Bluetooth
testo 440 is switched on.
or
1
Press
Bluetooth® is activated or deactivated and either appears or
disappears from the display.
You need to go to menu screen first and then select Settings.
1
Use to select Bluetooth.
and at the same time for at least 3 seconds.
reset)
®
connection
14
3 Operation
2
Use to enable Bluetooth.
Bluetooth® is activated or deactivated and either appears or
disappears from the display.
3
Press
or to exit the menu.
3.3.2 Setting power options
You can manage the energy consumption for your testo 440. The following
functions are available for this purpose:
Auto Off: testo 440 switches off automatically after 5 minutes of inactivity
Power Saving: the screen brightness is reduced to 10% after a minute; the
set brightness is restored by pressing any button
Brightness: setting the screen brightness from 10% to 100%
You need to go to menu screen first and then select Settings.
1
Use to select Power Management.
2
Press
3
Use to select the required setting and make changes.
If the Auto Off function is enabled, the testo 440 automatically switches
itself off after 5 minutes of inactivity.
If the testo 440 is in logger mode, the Auto Off function is automatically
deactivated during an active measurement.
4
Press
Setting Auto Off
or on the navigation key.
or to exit the menu.
You are in the Power Management menu.
1
Use to select Auto Off.
15