> Please read this documentation through carefully and
familiarize yourself with the product before putting it to use. Pay
particular attention to the safety instructions and warning advice
in order to prevent injuries and damage to the products.
> Keep this document to hand so that you can refer to it when
necessary.
> Hand this documentation on to any subsequent users of the
product.
Symbols and writing standards
Warning advice, risk level according to the
signal word:
Warning! Serious physical injury may occur.
Caution! Slight physical injury or damage to
the equipment may occur.
> Implement the specified precautionary
measures.
Note: Basic or further information.
1. ...
2. ...
Action: more steps, the sequence must be
followed.
> ... Action: a step or an optional step.
- ... Result of an action.
Menu
Elements of the instrument, the instrument
display or the program interface.
[OK]
Control keys of the instrument or buttons of
the program interface.
... | ... Functions/paths within a menu.
“...” Example entries
5
2 Safety and the environment
2.2. Ensure safety
> Do not operate the instrument if there are signs of damage at
the housing, mains unit or feed lines.
> Do not perform contact measurements on non-insulated, live
parts.
> Do not store the product together with solvents. Do not use any
desiccants.
> Carry out only the maintenance and repair work on this
instrument that is described in the documentation. Follow the
prescribed steps exactly. Use only original spare parts
from Testo.
> Dangers may also arise from the systems being measured or
the measuring environment: Note the safety regulations valid in
your area when performing the measurements.
2.2.1. Safety and the testo 510i
• Magnetic field
• May be harmful to those with pacemakers.
> Keep a minimum distance of 10 cm between pacemaker and
instrument.
2.2.2. Safety and the testo 549i
• Risk of injury due to pressurized, hot, cold or toxic
refrigerants/media!
> Only to be used by qualified staff.
> Wear protective goggles and safety gloves.
> Before applying pressure to the measuring instrument: always
fix the instrument tightly onto the pressure connection
> Comply with the permissible measuring range (0 to 60 bar). Pay
particular attention to this in systems with R744 refrigerant,
since these are frequently operated at higher pressures!
2.2.3. Safety and the testo 805i
• Laser radiation! Class 2 laser
> Do not look into the laser beam!
6
2.3. Protecting the environment
> Dispose of faulty rechargeable batteries/spent batteries in
accordance with the valid legal specifications.
> At the end of its useful life, send the product to the separate
collection for electric and electronic devices (observe local
3 Specifications
regulations) or return the product to Testo for disposal.
Testo Smart Probes are different hand-held measuring instruments
for various applications that communicate with your mobile terminal
devices by means of an app. The respective Smart Probe performs
the measurement and is operated by your mobile terminal device.
The various Smart Probes allow you to measure the temperature,
humidity, flow, and volume flow at the outlet, or perform pressure,
differential pressure, and non-contact temperature measurements
in the duct.
3 Specifications
7
4 Product description
4 Product description
4.1. Overview of Smart Probes
1 Measuring unit
2 LED
3 Key
4 Battery compartment (at the back)
5 Direction of flow testo 405i / testo 410i (not shown)
(An arrow on the top of the housing displays the direction of
flow in which the measuring instrument has been calibrated and
which achieves the best measurement results. Please note the
direction of flow during usage.)
4.2.LED status
LED status Meaning
Flashing red Low battery status
Flashing yellow
Flashing green
8
• Smart Probe is switched on.
• Smart Probe is searching for a BT connection, but is
not connected.
• Smart Probe is switched on.
• Bluetooth is connected.
5 First steps
5.1. Switching on/off
5 First steps
testo 549i
5.1.1. Switching on
1. Pull the film out of the battery compartment.
2. Press the button on your Smart Probe.
- The Smart Probe switches on.
5.1.2. Switching off
1. Press and hold the button on your Smart Probe.
- The Smart Probe switches off.
5.2. Establishing Bluetooth® connection
You need a tablet or smartphone with the testo Smart Probes App
already installed on it to be able to establish a Bluetooth connection.
You can get the App for iOS instruments in the App Store or for
Android instruments in the Play Store.
Compatibility:
• requires iOS 8.3 or later/Android 4.3 or later
• requires Bluetooth 4.0
• Tested with the following smartphones/tablets:
www.testo-international.com/de/smartprobesmanuals/
✓ The testo App Smart Probe is installed on your terminal device
and ready for use.
1. Press the button on the Smart Probe.
- The Smart Probe switches on.
- The LED flashes yellow while connecting via Bluetooth and
then flashes green once the connection is established.
9
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.