Testo 330i Specifications

Flue gas analyzer
testo 330i
We measure it.
Measurement location-independent operation and Bluetooth measurement value display via Smartphone/tablet and testo330i App
Non-paper documentation and report creation directly on site with the testo 330i App
Reliable flue gas probe attachment with the testoFix probe mount
Robust, completely sealed plastic housing for use in tough conditions
The testo 330i is the combination of proven technology and revolutionary handling. The basis of the flue gas analyzer is the measurement technology of the proven predecessor testo 330 LL, with these outstanding features:
- Longlife sensors with up to 6 years' lifetime, exchangeable by the user
- TÜV-tested according to 1. BImSchV (VDI 4206) and EN50379, Parts1-3
- Integrated gas and draught zeroing without probe removal
- Measuring range extension up to 30,000 ppm CO through automatic fresh air dilution
°C
CO/H
2
hPa
O
NO
ΔP
2
The operation of the measuring instrument and the display of the measurement values take place by Bluetooth via the testo 330i App on your Smartphone/tablet. This means you always have all relevant values at your fingertips right where you need them. After finishing the measurement, you can insert comments or photos of the plant into your report, and send it to your customer or your office by e-mail. Today's way to measure flue gas.
www.testo.com
testo 330i We measure it.
Technical data
Order suggestion testo 330i
testo 330i flue gas analyzer with Longlife gas sensors and integrated draught and gas zeroing, Bluetooth, rechargeable battery and calibration protocol
testo 330i 0632 3000 Option: H
General technical data
Compatability requires iOS 7.1 or newer /
Storage temperature -20 to +50 °C Operating temperature -5 to +45 °C Power supply Rech. batt. block 3.7 V / 2.6Ah
Memory 500000 readings Weight 720 g (excluding battery) Dimensions 270 x 160 x 57 mm Warranty Instrument/probe/gas sensors O
-compensated CO sensor 4
2
Android 4.3 or newer requires mobile end device with Bluetooth4.0
Mains unit 6 V / 1.2 A (optional)
48 months Gas sensor NO: 24 months Thermocouple and rech. battery: 12 months
, CO:
2
Order suggestion basic set testo 330i
testo 330i 0632 3000 Option: H Modular flue gas probe with hose (650 mm) 0600 9780 Combustion air temperature probe (190 mm) 0600 9787 International mains unit 0554 1096 testoFix probe mount 0554 3006 Instrument case for testo 330i, probes and accessories 0516 3302
-compensated CO sensor 4
2
Order suggestion professional set testo 330i
testo 330i 0632 3000 Option: H Modular flue gas probe with hose (650 mm) 0600 9780 Combustion air temperature probe (190 mm) 0600 9787 International mains unit 0554 1096 testoFix probe mount 0554 3006 testo 330i BLUETOOTH Instrument case for testo 330i, probes and accessories 0516 3302
-compensated CO sensor 4
2
®
/IRDA printer 0554 0621
Measurement parameter
Temperature (dependent on the thermocouple in the flue gas probe)
Draught measurement -9.99 to +40hPa ±0.02hPa or ± 5 % of m.v. (-0.50 to +0.60 hPa)
Pressure measurement 0 to 300hPa ±0.5 hPa (0.0 to +50.0 hPa)
measurement 0 to 21 vol.% ±0.2 vol.% 0.1 vol.%
O
2
CO measurement
-compensated)
(not H
2
CO measurement
-compensated)
(not H
2
with activated measuring range extension
CO measurement
-compensated)
(H
2
CO measurement (H with activated measuring range extension
Eciency testing (Eta)
Flue gas loss 0 to 99.9 % 0.1 %
determination
CO
2
(Calculation from O Option: NO measurement: 0 to 3000 ppm ±5 ppm (0 to 100 ppm)
-compensated)
2
)
2
Measuring
Accuracy (± 1 digit) Resolution
range
-40 to +1200 °C ±0.5 °C (0.0 - +100.0 °C)
0 to 4000 ppm ±20ppm or ±10 % of m.v. (0 to 400 ppm)
0 to 15000 ppm ±200ppm or ±20 % of m.v. (0 to 15000 ppm) 1ppm
0 to 8000 ppm ±10ppm or ±10 % of m.v. (0 to 200 ppm)
0 to 30000 ppm ±200ppm or ±20 % of m.v. (0 to 30000 ppm) 1ppm
0 to 120 % 0.1 %
Display area 0 to CO2 max
±0.5 % of m.v. (remaining meas. range)
±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % of m.v. (+3.01 to +40.00 hPa) (the greater value applies)
±1 % of m.v. (+50.1 to +100.0 hPa) ±1.5 % of m.v. (remaining meas. range)
±5 % of m.v. (401 to 2000 ppm) ±10 % of m.v. (2001 to 4000 ppm)
±20ppm or ±5 % of m.v. (201 to 2000 ppm) ±10 % of m.v. (2001 to 8000 ppm)
±0.2 vol.% 0.1 vol.%
±5 % of m.v. (101 to 2000 ppm) ±10 % of m.v. (2001 to 3000 ppm)
±0.1 °C (-40 - +999.9 °C) ±1°C (remaining meas. range)
0.01hPa
0.1hPa
1ppm
1ppm
1ppm
Loading...